Filter Sizing. Pressure drop determines filter size.

Slides:



Advertisements
Similar presentations
MAO Flow Meters Sales Deck | Presentation Title What is the MAO Flow Meter? The MAO flow meter is an instrument used for monitoring or measuring.
Advertisements

Accumulators.
Full Immersion Filter Cleaning Systems
KP 013 Pump Reservoir Calculations Oil Temperature- Although the pumps use cooling fins to help dissipate heat, we recommend that the continuous system.
Operation of One Speed Control valve. Transmission control valve N-range operation Transmission Control valve.
Water Hydraulic Valves
Low Pressure Motor Valves. Single Acting Motor Valve Single soft seat Tight shut-off Full line size opening Removable valve seat Optional opening assist.
Integrated bypass developed by Hydac SA. Time schedule What is an integrated bypass Why this development How do the IBP & IBT valves function Paolo 2.
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
BIRM For the reduction of rusty/brown/black staining and metallic taste resulting from Iron and/or Manganese in water.
1 Expansion Tanks. 2 3 Expansion Tanks WHY USE THEM TYPES LOCATION SIZING.
Mechanical AST5300 is a wet / wet differential pressure transmitter Compatible with liquids or gases on both the high pressure and low pressure process.

Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
Proportioning Systems. 69 Proportioning Systems Now you know the benefits and uses of water additives, especially Class A foam. So how do we get the concentrate.
20,000 Barrel Per Day Produced Water Treatment System
ECO ® Series Air Filtration Products Introducing the New ECO III Heavy Duty Air Filtration System.
Elements/Media t Types t Comparison t Which one do I use? t Construction t Testing.
Hydraulics.
Cheer up. It is not as difficult as you thought!
Proper Pump Installation Practices
Rotating Equipment PUMPS.
BLM National Training Center HYDRAULIC DESIGN PART 2.
Pressure Regulator Comparison What should your regulator do… REGULATE OR STRANGULATE?
Lubrication Systems Chapter 12 Page 143. Oil and It’s Route.
GARLOCK EXPANSION JOINT (MSDI-P13671) Systems Design Review January 11 th, 2013 Friday, January 11, 2013P Garlock Expansion Joint 1.
GARLOCK EXPANSION JOINT (MSDI-P1367) Systems Design Review January 11 th, 2013 Friday, January 11, 2013P Garlock Expansion Joint 1.
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
ENGINEERING YOUR SUCCESS. PDF Market and Sales Meeting Refrigerated Dryers.
Considerations for Selecting VFD’s Quentin Nesbitt, PE Agricultural Engineer Idaho Power Company.
Specifying and Sizing Control Valves A design equation used for sizing control valves relates valve lift to the actual flow rate q by means of the valve.
Asahi/America Swing Check Valves
Permanent Housing for a Ceramic Oil Filter MIM U702 Capstone Design reNU Design Team Dale Kochevar Kelly Seitz Marco Solia Barrett Straub Matt Whalen MIM.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
So Far: Mass and Volume Flow Rates Reynolds No., Laminar/Turbulent Pressure Drop in Pipes Flow Measurement, Valves Total Head, Pump Power, NPSH This Week:
Pump Selection Centrifugal - low P (
09/22/97 Product Overview. Product Index t Suction, Low Pressure (
The complete flow monitoring solution Measure – Display – Switch – Transmit.
Washington University ChE 433 Digital Process Control Laboratory Pressure and Level Control Lecture.
Flow Characteristics Viscosity determined through index matching, (550 SSU, 109 cP, Pa-s) – Much higher than water (1 cP) Flow tested by Army is.
High Pressure Motor Valve. High Pressure: 1” & 2” Screwed connection rated to 4000 psi standard. Can be rated up to 6000 psi. Motor: One that imparts.
Washington University ChE 433 Digital Process Control Laboratory Fluid Statics & Dynamics Lecture.
Booster Enclosure Corrector Prototype Installation Filter Installation Dissolved O2 Update 7/6/07 Maurice Ball Fluids Engineering AD/Mechanical Support.
Nitrous Oxide Properties Temperature (ºC) Vapor Pressure (Bar Abs.) Liquid Density (kg/m 3 )
HPU FILTERS LOW PRESSURE FILTER FROM APU UNIT. CLOSE APU HYDRAULIC FLUID VALVE. FILL FILTER WITH HYDRAULIC FLUID PRIO TO INSTALLATION. LUBRICATE GASKET.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Hydraulic Power. Hydraulics vs. Pneumatics Hydraulic Systems... Use a relatively incompressible liquid Have a slower, smoother motion Are generally more.
Hydraulic Flow Control MECH1300 Topics Flow Control Valve Types Flow Coefficient Circuits Cushioned Cylinders Flow Dividers Flow Control Valve Specifications.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 10 : CONTROL VALVES IN CLOSED LOOP SYSTEMS.
Chapter 41 Lubrication System Fundamentals.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
June 12, 2016 Portable Diesel Fuel Filtration. Product Overview Diesel requires filtration prior to use and long periods of storage. The Super Efficient.
Hydraulic Pressure Control
INNOVATION FILTER SYSTEMS (P) LTD Give the best Filtration Solutions Pune.
Theory of viscosity 1.Definition
Project Background The Army Medical Research Lab needs to validate their CFD models for healthy and diseased lungs RIT will perform particle image velocimetry.
Troubleshooting Hydraulic Pumps
SB Packing Automatic Downpuller Power Unit
Hydraulic Pressure Control
MINI 1A iAquaMax™ Kidney / water removal system
1A iAquaMax™ Kidney / water removal system
System One Pumps Selecting Centrifugal Pumps S1-201
Asahi/America Gate Valves
Quality Defines Success | Since 1976 |
System Curve Example Design Condition 20 ft.w.c. required each way to deliver design flow to and from the headers at the loads Distribution Pump Bell.
Engine Lubrication Systems
Solstice - Filtration System
P2 25 mm (1") Metal Pump.
Presentation transcript:

Filter Sizing

Pressure drop determines filter size

Filter Sizing t Pressure drop depends on:  Filter Housing  Media Grade  Fluid Viscosity –Temperature –Oil Type  Flow Rate

Filter Sizing Parker Rule-of-Thumb: Maximum Element Clean Pressure Loss: 1/3 bypass valve setting, or less

Filter Sizing 50 psid bypass valve 3 = 16.7 psid

Sizing Example t Fluid: Exxon Teresstic 32 t Flow: 40 gpm t Pressure: 800 psi t Filtration Specification: B 6 =200 t Operating Temperature: 70 o F to120 o F t Bypass Valve: 50 psid t Ports: 1 1/2” t Full filtration required at the most extreme conditions

Step 1 t Determine Viscosity Range

Exxon Teresstic 32 Specifications Data from Exxon handbook: o F o F Results from chart: 70 o F = 400 SUS 120 o F = 110 SUS

Step 2 t Determine viscosity range t Select housing series based on system pressure, mounting, options

Step 3 t Determine viscosity range t Select housing series based on system pressure, mounting, options t Select media grade to match B 6 = 200

Step 3

Step 4 t Determine viscosity range t Select housing series based on system pressure, mounting, options t Select media grade to match B 6 = 200 t Calculate pressure loss

40CN-1

Step 4 40CN-1 05Q (150 SUS) 40CN-1 05Q (400 SUS) Element = 12 psid Element = 32 psid 12(400/150) = 32 Housing = 3.5 psid Total = 15.5 psid Total = 35.5 psid

40CN-2

Step 4 40CN-2 05Q (150 SUS) Element = 6 psid Housing = 3.5 psid Total = 9.5 psid 40CN-2 05Q (400 SUS) Element = 16.0 psid 6(400/150) = 16.0 Housing = 3.5 psid Total = 19.3 psid

80CN-2

Step 4 80CN-2 05Q (150 SUS) Element = 3.0 psid Housing = 1.5 psid Total = 4.5 psid 80CN-2 05Q (400 SUS) Element = 8 psid 3.0(400/150) = 8 Housing = 1.5 psid Total = 9.5 psid

Filter Sizing