Presentation is loading. Please wait.

Presentation is loading. Please wait.

Full Immersion Filter Cleaning Systems

Similar presentations


Presentation on theme: "Full Immersion Filter Cleaning Systems"— Presentation transcript:

1 Full Immersion Filter Cleaning Systems
Mecair 514G & 564G Series Full Immersion Filter Cleaning Systems Mecair 564G Series

2 What is the 514G & 564G? Mecair 564G Series

3 514G and 564G Full Immersion The Mecair 514G and 564G systems are the replacement for the Mecair 514 and 564 series of Full Immersion filter cleaning systems. The 514G is mounted to an Ø8” tank and the 564G is mounted to a Ø6” tank. Recently, engineers at Pentair Environmental Systems updated the design of the Mecair Full Immersion range. The 514 and 564 were included in the update, and the 514 G and 564G are now in the process of release. The 514G and 564G are an updated full immersion design based on the Goyen 1.5” 45 Series double diaphragm pulse valves. The Goyen 45 series valves have been in production since 1992 with well over 1,000,000 valves installed worldwide. This upgrade results in greater durability and higher operating pressures. Mecair 564G Series

4 The 514G and 564G are dimensional replacements for the 514 and 564.
514G/564G Full Immersion The 514G and 564G have been configured to: Provide the same flow rates as the 514/564. Achieve greater durability when compared to the 514/564. Operate at higher pressure than the 514/564 (8.6bar instead of 7.5 bar) Be more responsive to the electrical signal than the 514/564. Use the same mounting dimensions and manifold designs as the 514/564. The 514G and 564G are dimensional replacements for the 514 and 564. Mecair 564G Series

5 Mecair 514G and 564G Diaphragm
Mecair 564G Series

6 514G/564G Diaphragm 514G/564G (New) Membrane material
Nitrile (standard) Viton (option) System Temperature range - 40 to 110°C (carbon steel tank) - 50 to 93°C (stainless steel tank) Operating pressure range 1.0 – 8.6 bar Tested durability at 8.6 bar >1,000,000 pulses A significant difference between the Mecair 514/564, and the Mecair 514/564G valves is the diaphragm design. The514/564G uses the diaphragm assembly and materials of the Goyen 1.5” 45 series pulse valves. This diaphragm construction has a 20 year history in general and gas turbine filter cleaning applications. The Goyen diaphragm design results in greater durability, higher operating pressures and improved performance. 514/564 (Previous) Membrane material Nitrile (standard) Viton (option System Temperature range - 40 to 110°C (carbon steel tank) - 50 to 93°C (stainless steel tank) Operating pressure range 0.5 – 7.5 bar Tested durability at 7.5 bar <1,000,000 pulses Mecair 564G Series

7 Mecair 514G and 564G Performance
Mecair 564G Series

8 514G and 564G Performance As tested, the 514G and 564G delivers the same flow rates as the 514 and 564, but is more responsive to the electrical signal, offering some reduction in the use of compressed air. Mecair 564G Series

9 Pressure measurements taken within the blowtube at first outlet.
514G/564G Performance 1. The peak pressure developed by the valve is the same for the 514G/564G and 514/564. 2. The 514G/564G closes approximately 15 ms sooner allowing better control of air consumption. NOTE: The 564G and the 514G are the same valves. The 514G is fitted to an 8” diameter manifold, and the 564G is fitted to a 6” diameter manifold. 1. 2. Pressure measurements taken within the blowtube at first outlet. The 514G/564G provides the same filter cleaning flowrates and filter cleaning performance as the 514/564 based systems. Mecair 564G Series

10 Mecair 514G and 564G Installation
Mecair 564G Series

11 514G/564G Installation Dimensions
The 514G/564G is interchangeable with the 514/564 on existing headers. The 514G/564G allows closer spacing than 514/564 on new header designs. Note: domed tank ends are no longer available for these systems. 514/564: Ø Tank Ø Valve P min K min R W Ø W DN6 1 ½” 160 mm 90 mm 50mm 15mm 1” DN8 115 mm 90mm 18mm Mecair 564G Series

12 514G/564G installation Dimensions
564G (DN6” tank) 514G (DN8” tank) 564 (DN6” tank) 514 (DN8” tank) Mecair 564G Serieso

13 514G/564G Assembly 514G 564G Mecair 564G Series

14 514G/564G Installation The 514G/564G System uses the same tank brackets as the 514/564. The 514G/564G uses the same pipe outlets as the 514/564. The 514G/564G uses the same pilot assemblies as the 514/564. Installation of the 514G and 564G cleaning systems is the same as for the 514 and 564 systems. Mecair 564G Series

15 Full Immersion Filter Cleaning System
Mecair 514G & 564G Series Full Immersion Filter Cleaning System Mecair 564G Series


Download ppt "Full Immersion Filter Cleaning Systems"

Similar presentations


Ads by Google