MODEL : EDF-102 SERIES 1. APPLICATION The EDF-102 thermostat is designed to provide temperature control of heating or cooling systems in villas, hotels.

Slides:



Advertisements
Similar presentations
Operating Functions.
Advertisements

Star kW NEW. Star kW Star kW Instantaneous wall-hung gas boilers Conventional flue Sealed room fan assisted NIKE Star 23 kW EOLO Star 23 kW.
Customer Service – International dept. STAR 24 3 E.
RWD CONTROLLERS TECHNICAL
Fan Coil Unit Product Line-up. FCU Home Application Show.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Thermostats. I would recommend that as you proceed through this power point presentation that you refer to your textbook, Unit 14, for some great visuals.
WebStat™ Programming and Configuration of Thermostats.
1 Gas Heat THERMOSTATS. 2 Thermostat A thermostat is a control that is activated by changes in the surrounding air temp.
FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.
Total HVAC Control from anywhere Easy control that can save a fortune
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
STAND ALONE CONTROL FOR TERMINALS
AQ2511B0 Boiler Reset Panel – for Whole House Heating Control – Immediate Retrofit Opportunity !
By: Alex Sowa Electrical Projects April 10 th, 2013.
LogTag Training January 2015
= ( es ) 2 energy savings. 53% SAVINGS* THAN OTHER LEADING INVERTERS! Best Energy Savings! High 11+ EER CASSETTE INVERTER FLOOR STANDING INVERTER HIGH.
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
- Product Overview – The LMD DEFLECTOMETER ® Series Inductive Loop Detector Why guess when you can know! © Copyright EDI 2013.
Presentation of product. Production capacity New heater For 15 years VTS Clima Group has been a leader in industrial heating engineering. Volcano VR.
KLINGE’S NMR 262 Two Independent Systems Integrated into one Unit This Requires Special Features:  Total Redundancy of Refrigeration Components  Total.
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
Siemens Building TechnologiesRWD heatpump controllers Xavier Zabalegui/David Jefferson 1 January 2003 RWD Heat Pump controllers RWD Heat Pump Controllers.
Commercial VisionPRO™ 8000
PYROCON12 De-Ice controller User Operation Presentation 2013.
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Homeowner Support Hotline:
ST9120U1003 Universal Electronic Fan Timer Training Module
AccuMax Multi-Point Injection Mechanics
Daikin Australia Pty. Limited Ducted Split Systems 2011.
Student Handout Packet Go to page A4. Please answer the following questions using page A4.
Homeowner Support Hotline:
1 Starting & Stopping Motors Pico Pico LAB#4. 2 Program a series of three basic ladder logic rungs. These basic rungs are the most common rungs found.
Fan Switch and Limit Switch Information. FAN Switch.
Paver System Five Control Box Overview Aug 2009 Control Box Overview Paver System Five.
MDS Smart Commander.
Wind Energy Station Directions. Simple Wind Generator 1.Connect the LED to the motor in the pvc stand (using the red and black wires). 2.Place the motor.
Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, Smile Controller Family.
I Pag 1 Microchiller 2. I Pag 2 I Pag 3 Information on the display.
Settings & Adjustments. Settings & Adjustments.
2010.
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
Home Guard Security System. Introduction & Basic Ideas Home Guard Security System.
How to use Touch Screen SeneS Technology. Co, Ltd.
Applied Systems News FWEC*A Rudolf BARET HEISSIG.
Training Session August 11, Nitro Express Features Probe or probeless operation from the same unit Compact splash resistant ABS enclosure Pre-wired.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
UTH-300 INSTALLATION AND MANUAL. Method of Wiring Adhesion Construction and Wiring Method #1.
Fan Coils Units Control
Service Section Technical Training December 2005.
Main contacts closed – RED Colour with ON
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
New features of Chamber Monitor Panel E. Furfaro 9 april 2012.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
Central Processing Unit 0500 with ECO
E3 HVACR Controls and Devices
shift to the Test Mode (Forced Operation).
User Operation Presentation
Fan Coil Controller FC/S 1.1
ABB i-bus® KNX Valve Drive Actuator VAA/A
Universal Interface, 4-fold, FM, US/U 4.2
E3 HVACR Controls and Devices
Chilled Beam Performance:
Architect’s Scale 1/4” = 1’-0”
Technician Operation Presentation
Overview of HVAC control panel
Total HVAC Control from anywhere Easy control that can save a fortune
ST9120U1003 Universal Electronic Fan Timer Training Module
Presentation transcript:

MODEL : EDF-102 SERIES 1. APPLICATION The EDF-102 thermostat is designed to provide temperature control of heating or cooling systems in villas, hotels and building. It can be used as part of a system in conjunction with boilers, thermal actuators, and zone valves. The unit with key pads and large LCD display is ideal for customers who want reliable precise temperature control from a modern looking, simple to program and easy to use products..Users can control 3-fan speed,, by sliding the key pad H.M.L manually. 2. FEATURES ■ The current temperature and heat/cool are to be displayed on LCD window. ■ The set temperature is displayed when setting and it will be changed to the current temperature in 3 seconds. ■ Manual 3-fan speed control ■ Heat/Cool changeover switch ■ It can control an actuator and a fan motor. ■ Wall mounted type 3. SPECIFICATION ■ Rated Voltage : AC110V/220V/50~60 Hz ■ Temperature Range : 5 ℃ ~ 70 ℃ ■ Temperature Accuracy : 1.5 ℃ Max ■ ON-OFF differential : 1 ℃ Max. ■ Temperature display and setting unit: 0.5 ℃ /STEP ■ Fan speed: 3 stage High, Medium, Low ■ Load Current : 1A/220V ■ Case material : ABS ROOM THERMOSTAT FOR FANCOIL UNIT

4. HOW TO USE ■ POWER The electric power is OFF when the slide switch is positioned on the left side. The green power lamp is ON when the slide switch is pushed to the 2 nd stage and the initial fan speed is High. ■ TO SET THE DESIRED TEMPERATURE 1) The previously set temperature is displayed once on LCD window when pressing ▲ (+) or ▼ (-) button. 2) Press ▲ (+) or ▼ (-) button to set the temperature as desired. 3) The set temperature is saved in 5 seconds and the current temperature is displayed on LCD window again. ■ FAN SPEED The bottom slide switch can control the fan speed H →M→ L. ■ HEAT/COOL CHANGEOVER Users should change the heat/cool switch on the right side to et the heat/cool mode. (H : Heating C: Cooling) Heating Operation 1) Set the heating mode (H). 2) When the set temperature becomes higher than the current temperature the red LED is ON and a symbol is displayed on LCD window. 3) When the current temperature becomes lower than the set temperature the red LED is OFF and the symbol is disappeared. Cooling Operation 1) Set the cooling mode (C). 2) When the set temperature becomes lower than the current temperature the red LED is ON and a symbol is displayed on LCD window. 3) When the current temperature becomes lower than the set temperature the red LED is OFF and the symbol is disappeared. ☞ Users should set the changeover switch to the heating mode in winter and cooling mode in summer.

6. AUXILIARY FUNCTION 1 st stage : Power OFF Fan OFF 2nd stage : Power ON High speed 3 rd stage : Mid speed 4 th stage : Low speed 5. POWER & FAN SPEED SWITCH Through this procedure users can set the maximum / minimum temperatures or compensate the temperature difference. Adjustable functions : OP1 - is to adjust the maximum temperature( 27~70 ℃. 81~158F) : OP2 - is to adjust the minimum temperature(5~26 ℃. 41~79F) : OP3 - is to compensate the current temperature.( -2 ~+2 ℃ ) 1) Turn off the power switch. 2) Press ▲ (+) and ▼ (-) buttons simultaneously for 1.5 seconds. Then, OP1 is displayed. 3) Press ▲ (+) button. Then OP1~OP3 is displayed in sequence. 4) Press ▼ (-) button to choose the desired functions 7. ERROR SIGN 1) Er1 : Sensor disconnection 2) Er2 : Sensor short

MOTORIZED VALVE AC220V H M L Black Red Blue Green Yellow Common EDF102 Brown Common FAN MOTOR 8. WIRING 9. INSTALLATION 10. MODEL SELECTION It is a wall mounted type. A bracket is provided. for the installation C : Celsius F : Fahrenheit EDF-102- □□ Power : A : AC220V B : AC110V