Large area detectors Aida WP 9.2 RD51 WG6

Slides:



Advertisements
Similar presentations
Resistive bulks industrialization Status report 2 OCTOBER 2012 Fabien Jeanneau | PAGE 1 RD51 Collaboration meeting | Stony Brook University | October 2012.
Advertisements

GEM Detectors for AnDY Nilanga Liyanage University of Virginia 1 Outline GEM chamber concept Large area GEM chamber projects Proposed GEM configuration.
Recent achievements and projects in Large MPGDs Rui de Oliveira 21/01/2009 RD51 WG1 workshop.
Status of the ATLAS MM project
General needs at CERN for special PCB’s Philippe Farthouat CERN.
Operational prototype work at CERN Status report MM Gen. Meeting, 06/11/2013 J. Wotschack1.
Read-out boards Rui de Oliveira 16/02/2009 RD51 WG1 workshop Geneva.
TE/MPE/EM/PMT activity Rui de Oliveira on behalf of PCB workshop team 29/11/20121.
Industrial Production of MPGDs Rui de Oliveira Workshop on neutron detection with MPGD CERN October
Atsuhiko Ochi Kobe University / MAMMA collaboration 24/04/2013 RD51 mini week, WG6.
WP7&8 Progress Report ITS Plenary meeting, 23 April 2014 LG, PK, VM, JR Objectives 2014 and current status.
CERN PCB workshop activities
1 SBS Spectrometer / GEP5 Conf.. 2 Tracking Requirements Requirements Tracking Technology DriftMPGDSilicon High Rate: MHz/cm 2 (Front Tracker)
Fabrication techniques and industrialization of MPGDs.
F. Formenti - Annecy industry-academia meeting on MPGDs - April 27th Efforts for industrialization of GEMs and Micromegas at CERN Outline: 1)WG6.
TE/MPE/EM/PMT Collaborations Rui de Oliveira on behalf of PCB workshop team 29/11/20121.
PCB issues requirements & procurement MMM Würzburg, 30/01/2014J. Wotschack1.
-Stephan AUNE- RD51 Bari 2010 CEA DSM Irfu 08/10/20101 Saclay MPGD workshop.
WG1 summary P. Colas, S. Duarte Pinto RD51 Collaboration meeting in Bari October 7-10, 2010.
Atsuhiko Ochi Kobe University 25/06/2013 New Small Wheel MicroMegas Mechanics and layout Workshop.
CERN PCB workshop CPW Rui de Oliveira on behalf of PCB workshop team 29/11/20121.
20/04/2012Rui De Oliveira1 20/04/2012. Rui De Oliveira2 30 cm x 30 cm example.
Situation with industry Rui de Oliveira RD51 CERN October
09/06/2009Rui De Oliveira1 Large MPGD production status.
Situation with industry
CERN Rui de OliveiraTS-DEM Rui de Oliveira TS-DEM Large size detectors CERN TS-DEM-PMT Capabilities.
15/07/2010Rui De Oliveira1 Update on large size GEM manufacturing Rui de Oliveira.
CERN workshop upgrade Aida fund Transfer to industry Rui De Oliveira 4/13/20111Rui De Oliveira.
PCB procurement WG Status report PCB WG status, 25/03/2014Joerg Wotschack.
EST-DEM R. De Oliveira 20 Dec., ‘04 Production of Gaseous Detector Elements  History of Gas Detectors in Workshop  Fabrication of GEM Detectors  Fabrication.
CERN Workshop upgrade Rui De Oliveira KOBE WG6 WG6 9/1/20111Rui De Oliveira.
CERN workshop upgrade Aida WP 9.2 Rui De Oliveira.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
5 th RD51 meeting (WG1) 25 May 2009 Atsuhiko Ochi ( Kobe University )
RD 51 & CERN Workshop Upgrade RD 51 & CERN Workshop Upgrade Leszek Ropelewski (CERN), Maxim Titov (CEA Saclay) CERN, November 6, 2009.
M. Bianco On behalf of the ATLAS Collaboration
Low Mass Rui de Oliveira (CERN) July
RD51 Collaboration: Development of Micro-Pattern Gaseous Detectors technologies Matteo Alfonsi (CERN) on behalf of RD51 Collaboration Current Trends in.
A New GEM Module for a Large Prototype TPC: Status and Plans By Stefano Caiazza On behalf of the FLC DESY.
Resistive protections Rui de Oliveira 09/12/15
Plans for MPGD Radiation hardness tests for full detectors and components Matteo Alfonsi,Gabriele Croci, Elena Rocco, Serge Duarte Pinto, Leszek Ropelewski.
30/09/2010Rui De Oliveira1.  GEM Single mask process  Micromegas  Bulk  Classical  resistive 30/09/2010Rui De Oliveira2.
CERN Rui de OliveiraTS-DEM Rui de Oliveira TS-DEM Large size detectors practical limits based on present knowledge.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
CERN Workshop upgrade status Rui De Oliveira RD51 22/11/2011 WG6 WG6 9/1/20111Rui De Oliveira.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
Construction and beam test analysis of GE1/1 prototype III gaseous electron multiplier (GEM) detector V. BHOPATKAR, E. HANSEN, M. HOHLMANN, M. PHIPPS,
Zaragoza, 5 Julyl Construction of and experience with a 2.4 x 1 m² micromegas chambers Givi Sekhniaidze On behalf of the Micromegas community.
R&D ON RESISTIVE TECHNOLOGY FOR MICROMEGAS BUKL STEPHAN AUNE 03/06/2015. S.Aune.
 Large GEM  CMS RE1-1  Kloe  Ns2 ( No stretch No stress)  Large Micromegas  Atlas MAMA project  Large THGEM  Double phase pure argon project 
1 Fulvio TESSAROTTO CERN, 13/11/ COMPASS THGEM meeting Construction of the large size Hybrid Prototype The bulk Micromegas technology Examples of.
Suggestions for a MPGD Workshop in Frascati Rui de Oliveira 1.
GEM, Resistive M-Bulk, ThGEM detector production. Rui De Oliveira, Cosimo Cantini, Antonio Teixeira, Olivier Pizzirusso, Julien Burnens Annecy 26/04/2012.
Large size MPGD production: -GEM update -read out board infos Rui De Oliveira CERN 28/04/2009.
MPGD TECHNOLOGIES AND PRODUCTION GEMMicromegas Resistive MSGC (NEW!) Rui De Oliveira 7/12/20111Rui De Oliveira.
GEM, Micromegas detector production. detector’s dynamic range detector’s dynamic range Rui De Oliveira Catania 24/11/ /11/20111Rui De Oliveira.
Large GEM prototype production NS2 technique. Reminder NS2 technic 10 to 15mm Readout connector O-ring Drift electrode Free to slide External screws to.
1 RD51 Kolimpari June 2009 Stéphan AUNE, BULK lab at Saclay.
A High Eta Forward Muon Trigger & Tracking detector for CMS A High Eta Forward Muon Trigger & Tracking detector for CMS Archana Sharma For CMS High Eta.
Rui De Oliveira Vienna March 2014 Industrialisation of Micromegas detector for ATLAS Muon spectrometer upgrade 1.
GEM Integrated PCB readout and cooling
Large volume GEM production Rui De Oliveira TE/MPE/EM
Rev:A ( check-->19 pages document)
New MPGDs at CERN PCB Workshop
GEM and MicroMegas R&D Xiaomei Li Science and Technology
GEM-VIEW: Direct Data Radiodetector based on GEM technology
Gaseous detectors Task Resistive anode Micromegas
Efforts for industrialization of GEMs and Micromegas at CERN
Saclay MPGD workshop.
MPGD Experience with Technology Transfer
Presentation transcript:

Large area detectors Aida WP 9.2 RD51 WG6 Rui De Oliveira

outline AIDA project Largest GEM NS2 description and projects Industry status Largest Micromegas industry status conclusion

CERN workshop upgrade for MPGD CERN have invested in 9 machines for large MPGD production. The 9 machines are at CERN 5 machines are installed and commissioned 4 are still not installed , the installation is postponed . The machines will be installed directly into the new building 107 (no space in existing premises) This decision does not affect the running R&Ds The processes involved in these 4 machines are standard only the size of the machine have been increased. No commissioning is needed Deliverables: redefine all the process parameter related to the new equipment's Build prototypes with these equipment Man power: 4 CERN staff during 4 years up to 15% of their time 1 technician during 2 years (AIDA contribution) Juliens Burnens 1/07/2011  31/12/2011 Michal Zientec 1/01/2012  31/12/2012 Kacper Kapusniak 1/04/2014  31/12/2014

Equipment status GEM installation Commissioning 1/ continuous polyimide etcher 06/2012 OK 2/ Cu electro-etch line 06/2012 OK Micromegas 3/ large laminator 06/2011 OK 4/ large Cu etcher postponed no need 5/ large UV exposure unit 06/2011 OK 6/ large resist developer postponed no need 7/ large resist stripper postponed no need 8/ large oven 06/2011 OK 9/ large dryer postponed no need Juliens Burnens 1/07/2011  31/12/2011 Machines: 3,8 Michal Zientec 1/01/2012  31/12/2012 Machines: 2,5 Kacper Kapusniak 1/04/2014  31/12/2014 Machine: 1

UV exposure unit limited to 2m x 0.6m  2.2m x 1.4m Resist developer limited to 0.6m width  1.2m Resist stripper “ Copper etcher “ Dryer “ GEM electro etch limited to 1m  2m GEM polyimide etch limited to 1m  2m Ovens limited to 1.5m x 0.6m  2.2m x 1.4m Laminator limited to 0.6m width  1.2m

R&D Projects made with these equipment SBS tracker GEM 600mm x 500mm ALICE TPC upgrade GEM 600mm x 400mm CMS muon GEM 1.2m x 450mm ATLAS NSW muon Micromegas 2m x 1m COMPASS pixel Micromegas GEM & Micromegas 500mm x 500mm BESIII GEM 600mm x 400mm KLOE GEM 700mm x 400mm SOLID GEM 1.1m x 400mm CLAS 12 Micromegas 500mm x 500mm LSBB (geoscience) Micromegas 1m x 500mm Prad GEM 1.5m x 55cm CBM GEM 1m x 450mm ASACUSA Micromegas Most of them are still at the R&D phase but some are already in production: ATLAS NSW 1300 m2 SBS Tracker 100 GEMs ALICE TPC upgrade 350 GEMs COMPASS pixel Micromegas 20 GEM + Micromegas BESIII 15 GEM CLAS 12 30 Micromegas CMS 450 GEM

Largest GEM ever produced for Prad prototype -Size 1.5m x 0.55m -140um pitch -70um hole Read-out -2D -Compass type -400um pitch

Single mask introduces cost reduction 10cm x 10cm GEM example 10cm x 10cm GEM low volume -300 CHF/piece 10cm x 10cm GEM high volume - 80 CHF/piece

NS2 assembly of 3 GEMs

NS2 3.0 External frame without holes inner frame Brass Fittings

NS2 projects CBM Under characterization 2 detectors built Dubna Prototype production CMS 2 long version in production 5 STD KITS to be delivered

Largest NS2 detector : CMS GE1/1 long First trial of PU-less detector 1.3m x 0.5m GEM 1.3m x 0.5m Double sided board 3.2mm thick 1.3m x 0.5m Double sided board 3.2mm thick

Brass fittings assembly

External frame

inner frame

stretching principle

CMS GE1/1 NS2 detector assembled

Measured Back Side (μm) Industry status GEMs Tech-etch (US)  single mask 1m x 0.5m OK Techtra (PL) single mask 30cm x 30cm OK Mecharonics (KR) single mask 1m x 0.5m in progress Micro Pack (India) single mask 10cm x 10cm in progress Foil # Current (A) Voltage (V) Etch Time (min) Measured Back Side (μm) 1 2 ~ 0.8 15 ~ 25 μm 4.5 ~0.9 12 ~ 30 μm 3 ~0.8 30 ~ 40 μm 4 5 ~ 1 34 ~ 70 μm (over etched corners) ~ 0.7 50 ~ 70 (slightly over etched corners) ALICE IROC Made in Tech-etch

For detector smaller than 1m x 0 For detector smaller than 1m x 0.5m 100% of the GEM detectors parts are available in industry

Problems

Largest Micromegas produced for NSW prototype ATLAS NSW upgrade detector 2m x 1m opened Detector closed

Open Mechanical support STD Micromegas structure Drift electrode Pillars (128 µm)

STD Micromegas structure Closed Mechanical support

50um Kapton + resistive strips + glue + hole PCB + readout strips 25um solid Glue High temp Gluing Resistor HV connection ESL 1901 SD by local screen Printing (manual) Pillars creation Crete june 2009 Rui De Oliveira

Screen printed resistive layer : Semi automatic machine Printing area 1.5m x 0.9m 50um Kapton 50um Kapton + resistive strips

Industry status Micromegas ELTOS , ELVIA , Triangle Labs: BULK ok up to 50cm x 50cm STD Micromegas up to 2.2m x 0.5m Other companies showing interest: Trackwise (UK) PCB electronics (Israel)

Conclusion Out of the Building 107 the project is on time We are ready for 2m x 0.5m GEM Micromegas are already available in 2m x 0.5m