Standard Protocol Development for Advanced RTU Control Retrofit August 15, 2013 Presentation to: Regional Technical Forum RTUG Subcommittee Sponsored by:

Slides:



Advertisements
Similar presentations
4 basic approaches to determining energy efficiency benefits (savings) 1.Stipulated or deemed savings 2.Individual Building Metering – Measurement and.
Advertisements

Add Doors to Open Multi-deck Cases: Provisional UES RTF Meeting August 30,
UPDATE ON GROCERSMART 4.0 RESEARCH PLAN Regional Technical Forum May 3, 2011.
Emerging Technology Field Test 1 February 5, 2015 Brown Bag Mira Vowles, BPA Wesley Saway, BPA.
BPA Guidelines for Measurement & Verification of Energy Efficiency Measures Presented at Brown Bag Session November 29, 2006.
Non-Res Lighting Subcommittee Retrofit Lighting Standard Protocol Review 10/23/13.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
+ Impact Evaluations and Measurement and Verification First we will focus on ‘Gross Savings’ Determination - savings determined irrespective of why 1 Kentucky.
Advanced Rooftop-Unit Control – Retrofit Savings Analysis Overview 1 February 13, 2015 RTF Commercial Rooftop-Unit Working Group Mira Vowles, BPA.
1 Roof Top Units Saving Energy and Improving Occupant Comfort Presented by Ethan Bellavance and Mary Jane Poynter.
Residential Clothes Washers and Dryers Technical Subcommittee Ryan Firestone & Christian Douglass Regional Technical Forum March 10, PM.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Industrial Pump Motor VFDs: Provisional Standard Protocol Christian Douglass Regional Technical Forum 5/12/2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
Premium Rooftop Unit (RTU) Retrofit Overview August 20, 2012 RTF RTU Working Group Mira Vowles, BPA 1.
Heat Pump Water Heater (HPWH) Subcommittee Christian Douglass Regional Technical Forum June 18, 2015.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee November 16, 2011 Mira Vowles, P.E., CEM.
Retrofit Doors to Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Pump VFD Provisional Standard Protocol Regional Technical Forum June 18, 2013.
EvergreenEcon.com Heat Pump Water Heater Model Validation, Market Progress Assessment, and Process Evaluation RTF HPWH Sub-Committee Meeting October 15,
Guidelines for the Development and Maintenance of RTF- Approved Measure Savings Estimates December 7, 2010 Regional Technical Forum Presented by: Michael.
Overview of the Regional Technical Forum Guidelines January 22, 2013.
Non-Res Lighting Subcommittee Retrofit Lighting Standard Protocol Review 04/03/14.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Agricultural Irrigation Pump Variable Frequency Drive Provisional Standard Protocol Proposal Regional Technical Forum April 16, 2013.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum March 18, 2014.
MBCx Projects – Programs, Process, and Results Soda, Tan, Shields and Wurster David Jump, Ph.D., P.E., Matt Denny, P.E. Quantum Energy Services & Technologies,
Main Headquarters: 120 Water Street, Suite 350, North Andover, MA With offices in: NY, ME, TX, CA, OR Standard Protocol for Non-Residential.
BPA RTU Winter Operation Presented to: RTUG August 2010 Presented by: Kathryn Hile, The Cadmus Group Howard Reichmuth, New Buildings Institute.
RTF Pump VFD Provisional Standard Protocol Regional Technical Forum June 18, 2013.
July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
Energy Trust of Oregon Small Commercial HVAC Pilot Program Stellar Processes December 15, 2009.
Update: Grocery Refrigeration Provisional Standard Protocol for Site Specific Savings RTF Meeting June 28,
RTU Measure Preparation for Review as Standard Protocol Staff Request for Authorization of RFP Funding from the Regional Technical Forum 28 June 2011.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.
N ETWORK PC P OWER M ANAGEMENT June 28, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
BPA M&V Protocols Overview of BPA M&V Protocols and Relationship to RTF Guidelines for Savings and Standard Savings Estimation Protocols.
RTF Custom Protocols: Background, Issues and Critical Elements February 8, 2012 Regional Technical Forum Subcommittee on Impact Evaluation and Custom Protocol.
Linking the Wholesale and Retail Markets through Dynamic Retail Pricing Presented by: Henry Yoshimura Manager, Demand Response ISO New England September.
Evaluation of the RTF Standard Protocol Fan and Cooling Savings from Commercial-Sector Heat Pump Units Rooftop Unit Working Group (RTUG) August 20, 2012.
RTU Savings Research Project RTU Savings Research Project: Findings and Recommendations Regional Technical Forum February 3, 2009 Mark Cherniack Howard.
Scientific Irrigation Scheduling Provisional Standard Protocol Regional Technical Forum November 19, 2013.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Measurement and Verification of Refrigeration Measures in 4 Grocery Stores in Pacific County Presented to the Regional Technical Forum August 8 th, 2006.
Integration Issues for RTF Guidelines: Savings, Lifetimes and Cost/Benefit October 24, 2012 Regional Technical Forum Presented by: Michael Baker, SBW.
Regional Technical Forum Automated Conservation Voltage Reduction Protocol.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee August 28, 2013 Mira Vowles, P.E., CEM.
Proposed Rooftop HVAC Standardized Field Measurement Protocol and Annual Savings Calculator RTUG REVIEW January 31, 2012.
Grocery VSD Measure Deemed Savings Reid Hart, PE & Ken Anderson September 28, 2010.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
Utilities’ Update on Energy Savings Assistance Program Studies Ordered in D LIOB Meeting August 21, 2013 Sacramento, California.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
PNW RoofTop Unit Working Group - RTUG – RTU Savings Research Project Phase 3 December 15, 2009.
Scientific Irrigation Scheduling Subcommittee Thursday, August pm – 3pm, PDT.
A Reliable but Simplified Method for Measuring the Savings from Advanced RTU Control Retrofits February 13, 2013 Presentation to: RTF Commercial Rooftop.
Regional Technical Forum Recommissioning commercial retail facilities: A whole building approach to energy savings April 7th, 2009 Presented by: Jeremy.
VRF Applications in PNW RTF RTUG Meeting October 26, 2011 Kevin Campbell Reid Hart, PE Technical Research Group.
Proposed Edits to the Air Source Heat Pump Specifications Regional Technical Forum August 20, 2013.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Performance Tested HVAC Presentation to the RTF January 5, 2010.
G UIDELINE R EVISIONS – R ELEASE February 1, 2011 Regional Technical Forum Presented by: Michael Baker.
RTF RTUG Update Aug 12, 2010 “The Turn of the Screw” Premium Ventilation Extended Monitoring Reid Hart, PE Associate Director Technical Research Group.
ECAM M&V Examples For Packaged Equipment Bill Koran, P.E. Director of Energy Analytics, NorthWrite Inc.
Page 1 IceCold Pilot Study. Page 2 Pilot Candidate: Siemens 501 Fountain Parkway 32 RTUs provide cooling to 170,000 SF of Office and Production Spaces.
Prepared For: Prepared By: 100 Montgomery Street, Suite 600 San Francisco, CA Market Street San Francisco, CA The Benefits of Retrocommissioning.
Turning Energy Data into Operations Intelligence Presented to: FMA September 17, 2013.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
RTF Delivery Verification Guidance Batch 3 Jennifer Light Regional Technical Forum November 10, 2015.
A Calculator for Reliably Measuring the Savings from Advanced RTU Control Retrofits August 27, 2015 Presentation to: RTF Commercial Rooftop Unit Working.
Presentation transcript:

Standard Protocol Development for Advanced RTU Control Retrofit August 15, 2013 Presentation to: Regional Technical Forum RTUG Subcommittee Sponsored by: Bonneville Power Administration Presented by:Michael Baker, SBW Consulting, Inc. Bill Koran, NorthWrite, Inc.

Agenda Introductions Review Specification for Advanced RTU Control Retrofit Measure Developing an RTF Standard Protocol Subcommittee Guidance on How to Proceed 2 August 15, 20013

Key Terms Premise – a collection of utility meters that generally serve an entire building but can be a portion of a building as in the common areas of a mall. Premise interval metering – measurement of power at the utility meters for intervals of time. Used to derive daily premise energy use. Unit Power – in this context is the power draw of a retrofit RTU. Signal to Noise – the change in use due to the measure is the signal. Other unrelated use on the premise or unit meter is the noise. Cycling – refers to switching between standard and efficient mode for the advanced controls. Standard more tries to emulate baseline conditions, but has its limitations. Daily cycling has been used at PNNL sites. Other trends – refers to changes in premise energy use unrelated to the measure, such as modification to set points 3 August 15, 20013

RTF Standard Protocols – Development and Application Develop  Measure specification  Define best practice savings estimate  Identify candidate simplified methods  Data to prove simplest reliable method is … Not available or sufficient - approve a Provisional protocol and use in collecting needed data Available – approve protocol as Proven Apply  Two options Use in estimating savings for all projects Use in estimating savings for a sample in support of impact evaluation  Can be applied by a program operator, subject to “faithful application” review by an impact evaluator 4 August 15, 20013

Protocol Measure Specification Eligible systems  Rooftop package and split systems providing heating, cooling and ventilation with constant or multi speed supply fans and constant or multi speed compressors. Either gas or electric (resistance or heat pump) heating. RTF Baseline  Pre-conditions Eligible controls retrofit  Supply fan control using variable speed drive, multi-speed or cycling; demand-controlled ventilation; and differential, integrated economizer control; control of heating and cooling coordination with fan speed optimization.  Can operate in standard (baseline simulation) and efficient modes and cycle between modes on a daily basis 5 August 15, 20013

Test sites and their characteristics Everett Service Center  Heat pump  Office and warehouse  6 of 6 RTU retrofit Staples  Gas pack  Retail  5 of 6 RTU retrofit Federal Way Commons  Heat pump  Mall common Area  11 out of 11 RTU retrofit 6 August 15, 20013

Best practice savings estimates Definition  Long-term cycling – approximately 1 year  Interval measurements of true power for each unit used to derive total daily kWh for all retrofit RTUs  Savings derived from comparison ECAM change point models of daily temperature vs. total unit kWh  Models for standard and for efficient mode days Limitation  Cannot model other improvements such as RCx  Standard mode may not equal baseline Broken economizer Fans set to Auto 7 August 15, 20013

Can we simplify best practice method? Simplification  Use utility interval meters to derive total daily premise-level electric use  Avoids costly unit-level power measurements Challenge  Signal to noise ratio  How much of the premise-level use is associated with the RTUs Test  Model same period of cycling  Compare savings and uncertainty 8 August 15, 20013

Premise vs. Unit Cycling models Same time periods for each model at a site 9 August 15, 20013

Everett Service Center Models 10 August 15, 20013

Everett Service Center Interval Models 11 August 15, 20013

Staples Models 12 August 15, 20013

Banner Bank Models 13 August 15, 20013

Federal Way Commons Models 14 August 15, 20013

Simplified method #1 – Premise level pre/post Method  Derive daily premise kWh from utility interval metering  ECAM change point models comparing pre and post years Advantages  Avoids need to cycle  Captures true baseline  Captures other efficiency improvements made at the same time Limitations  Requires interval metering (what is the status of AMR?)  Reliability depends on signal to noise  Cannot handle unrelated trends  Protocol would have rules about acceptable model residuals 15 August 15, 20013

Comparison of unit-cycling to premise pre/post models Different time periods for each model at a site. Placed on common time using TMY3. 16 August 15, What happened?

What Happened #1 Everett Service Center Changes over Time 17 August 15, 20013

What Happened #1 Everett Service Center Changes over Time RTU Power Model 18 August 15, 20013

What happened #2 Staples Ventilation Changes Pre-install interval meter baseline Post-install baseline emulation 19 August 15, 20013

More Challenges: Federal Way Commons Baseline RTU Power Scatter With Model 20 August 15, 20013

What happened? 21 August 15, Heating Setpoint Change

Omit Data After Setpoint Change Including Setpoint Change ExcludingSetpoint Change 22 August 15, 20013

When can this method be used? Signal to Noise  Screen using low-cost metrics Name plate RTU kW vs. peak daily premise kW Other trends  Screen using time-series trends in model residuals Does this bias standard protocol  Signal to Noise and other trends are independent of savings  Savings per ton derived from sample of measures that passed screen should be reliable and applicable to program savings estimate 23 August 15, 20013

A second simplified method? What if there is no premise interval meter? Use best practice measurements and models  Unit power metering  Cycling Can we cycle for less than one year?  Proposed to test 60 days starting with each of 12 months 2 30 day periods, 6 months apart, starting with each of 12 months  What periods are feasible in terms of project development When can this method be used  Working economizer  Fans not on auto 24 August 15, 20013

Is there a third Method? Premise interval data with cycling Same limitations as Method 2  Economizer working  Fans not on Auto Additional limitation  Signal to Noise Ratio Requires  Premise interval meter  Cycling like method 2 Advantage  Avoids unit power measurement 25 August 15, 20013

Can fan power be used instead of unit power Would models be biased by excluding measurements of heating and cooling? Can a relationship be derived to estimate unit power from fan power based on the PNNL data? 26 August 15, 20013

Comparison of fan and unit savings 27 August 15, 20013

Guidance on how to proceed Possible protocol strategies  Further analysis of PNNL data Investigate short-term cycling periods Estimating savings from fan power  What is a practical plan for provisional data collection Can we create more test sites from existing projects  Sites with premise interval metering before and after install  Where we could install temporary power metering and turn on cycling Posting PNNL data on RTUG website Would another year of PNNL post (non-cycling data) 28 August 15, 20013