HEAT LOAD ESTIMATING USING THE RULE OF THUMB METHOD © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.

Slides:



Advertisements
Similar presentations
COOLING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Advertisements

Truck-Trailer Refrigeration Equipment
Grimsby Secondary School
LEAK DETECTION METHODS © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
eQuest Quick Energy Simulation Tool
© Commonwealth of Australia | Licensed under AEShareNet S Licence Common hazards at events Stage area List hazards.
Five star hotel in Nablus
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Permanent Head Gasket & Block Repair w/Nanotechnology, 32 Fl Oz
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
IX. REDUCING GREENHOUSE TEMPERATURE A. temperature regimes –range deg, stress above 90 deg.
100% Outside Air and Dehumidification Management
GENERAL RULES FOR HANDLING REFRIGERANT GAS CYLINDERS © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
The Three Tiered Philosophy
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY. “Air conditioning is the control of the humidity of air by either increasing or decreasing its moisture content.
PSYCHROMETRIC CHART © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Condensation Piping and Installation Drain Pans
HEAT LOAD ESTIMATING USING THE SHORT COMPREHENSIVE METHOD © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
PRESSURE MEASUREMENT INSTRUMENTS © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
What does this picture have to do with…… Battery Charger Sizing?
Your School Energy Saving Plan Put in photos of people who did the audit on this slide Put your school logo here Date.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
10 Energy Saving Advices. 1- Lowering of the temperature at night Limit the lowering of the temperature at night. If the temperature is reduced too much,
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
DUCT EFFICIENCY AND HEAT PUMP PERFORMANCE Paul Francisco David Baylon Ecotope, Inc.
Steam System Operation and Distribution System Optimization Affordable Comfort National 2013 Denver, Colorado.
Introducing. The Comfort Zone (75° /50% RH) Every HVAC system is trying to hit this target. Hot, humid climates High latent load. The Challenge:
Important variables Water: Air: Conversion:
Air Conditioning Heating Refrigeration
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
TEMPERATURE AND RELATIVE HUMUDITY MEASUREMENT INSTRUMENTS © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
HEAT LOAD ESTIMATING USING THE QUICK SELECT METHOD © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
So… How does Smartcool achieve savings??.  Compressors use 70% of the energy in refrigeration and air conditioning systems.  The cooling cycle is dynamic.
Trade Skills Print Reading and Ductwork. 2 Drawings are a useful tool in manufacturing and construction because most people find it difficult to.
FUNDAMENTALS OF HEAT LOAD CALCULATIONS Part 1. What Causes Heat Loss Temperature difference Outside Inside.
Objectives Define psychrometric quantities Continuation from previous class Draw psychrometric processes Relate psychometric variables to human comfort.
Refrigeration Plant Design – Progress Report 1 Kevin W. Hunter MANE-6980 Engineering Projects.
Heat Migration in the Home 1 Energy Analysis and Comfort Solutions, Inc. Understanding Heat Migration in Your Home.
GAUGE AND MANIFOLD IDENTIFICATION © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
FILTERING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Dehumidification Justin Dunnahoo.
AIR HANDLING SYSTEM © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
CBE 150A – Transport Spring Semester 2014 Radiation.
EXAMPLE EXERCISE CALCULATING HEAT LOSS & HEAT GAIN  Several exhibits in the class packet are necessary to understand the entries into the Heat Loss /
© March 2008Environmental Stress Systems1 What you need to know when choosing a cascade condensing unit for your unique application Specifying Cascade.
HUMIDIFYING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Authors: William Tschudi, Lawrence Berkeley National Lab Stephen Fok, Pacific Gas and Electric Company Stephen Fok, Pacific Gas and Electric Company Presented.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Chapter 8: The Cooling Load Cooling load is the rate at which energy must be removed from a space to maintain the temperature and humidity at the design.
How To Prevent Condensation On The Windows Of Your Home.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Space Air Diffusion. Fundamentals  Objectives – thermal comfort and indoor air quality – even space air conditions – acceptable air cleanliness – acceptable.
Maria’s Restaurant Chapter 2 Section 9
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Part 4 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Distributing the Sun’s Heat - WIND
Did you know? In the U.S. alone, buildings account for: 72% of electricity consumption
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY
IS 1391: Air Conditioning Specification College of Engineering Pune (COEP) Forerunners in Technical Education 1.
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Adding Zones to Existing Systems
Mandatory Design Requirements
FBE03: Building Construction & Science
Lack of Energy Storage will be a Constraint to Increasing Renewables beyond “XX”% (Depending on who you ask!) Solar is pushing peak later Residential.
Distributing the Sun’s Heat - WIND
Objective Revie the Cooling Cycle Learn about air distribution systems
Maria’s Restaurant Chapter 2 Section 9
Presentation transcript:

HEAT LOAD ESTIMATING USING THE RULE OF THUMB METHOD © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence

 Hello, I would like to show you how I estimate heat loads using the rule of thumb or check figures method.  This method allows a set number of watts per m² of floor space. This method doesn’t make any allowances for insulated or uninsulated ceilings or west or non- west facing walls. Neither does it allow for variations in the number of people occupying the space or the type of activity. © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence

 This is the floor plan for a job I worked on recently.  The floor area is 5 m x 4 m = 20m². © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence

 The heat load is 2400 watts.  Therefore, this method of heat load estimation recommends a system with a cooling capacity of 2400 watts. © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence

 Once the heat load has been estimated, the next step is to select an appropriately sized air conditioner. To do this I need information from the air conditioner manufacturers. Most manufacturers will have a brochure that contains the specifications of a range of systems. © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence

 We have to be careful when recommending the right size air conditioning system.  When a heat load estimate is calculated it provides a guide to the required cooling capacity for a system which will create satisfactory conditions within the air conditioned space. This calculation is made for a given set of conditions, and usually assumes an ambient temperature of about 32 °C and a relative humidity of about 65%.  An over sized system will not always provide satisfactory performance. In some cases, a slightly smaller system may be more desirable. © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence

 An over sized system will rapidly cool the area without allowing sufficient time for de-humidification (moisture removal). Frequent cycling of the system on and off by the thermostat can also result in more wear and tear than if the system runs steadily for longer periods.  On the other hand an under sized system will be incapable of providing comfort during times of extreme heat. © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence