Ventilator Graphics Chapter 10. Graphics Monitor the function of the ventilator Evaluate the patient’s response to the ventilator Help the clinician adjust.

Slides:



Advertisements
Similar presentations
Patient – Ventilator Asynchrony
Advertisements

REPRESENTACION GRAFICA DE CONDICIONES CLINICAS EN LAS CURVAS DE MONITOREO VENTILATORIO.
Ventilator Waveforms: Basic Interpretation and Analysis
The Map Between Lung Mechanics and Tissue Oxygenation The Map Between Lung Mechanics and Tissue Oxygenation.
Initial Assessment of the Mechanically Ventilated Patient
Respiratory Calculations
Improving Oxygenation
Mechanical Ventilaton Ramon Garza III, M.D.. Indications Airway instability Most surgical patients or trauma Primary Respirator Failure Mostly medical.
Mechanical Ventilation in the Neonate RC 290 CPAP Indications: Refractory Hypoxemia –PaO2 –Many hospitals use 50% as the upper limit before changing.
Introduction to Mechanical Ventilation
Trigger/Limit/Cycle/Baseline
Mechanics of Ventilation
Initiating Positive Pressure CMV A generic approach!
Troubleshooting and Problem Solving
Determining the appropriate level of PSV By Elizabeth Kelley Buzbee AAS, RRT-NPS, RCP.
Interpretation of Ventilator Graphics
Ventilator Graphics: Not Just Pretty Lines
Initiation of Mechanical Ventilation
Waveforms RC 270 Pressure Volume Curves  Graphic display of changes in compliance and resistance  Used for TREND analysis! – One set of waveforms must.
Initial Ventilator Settings
Department of Critical Care Medicine Kovai Medical Center and Hospital.
Objectives Discuss the principles of monitoring the respiratory system
Copyright 2008 Society of Critical Care Medicine Mechanical Ventilation 2.
SERVO-i VENTILATOR GRAPHICS
RC 210 Chapter 7 Lecture 1. Primary Goal Overall primary goal of mechanical ventilation is to meet the oxygen and carbon dioxide requirements for patients.
Ventilator Check It’s a thorough process that should take longer than 2 minutes!
How a Breath is Delivered
Ventilator Waveforms: Basic Interpretation and Analysis
MECHANICAL VENTILATION
Selecting the Ventilator and the Mode
Advanced Pulmonary Mechanics during Mechanical Ventilation
By: Susan P. Pilbeam, MS, RRT, FAARC John D. Hiser, MEd, RRT, FAARC
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 19 Mechanical Ventilation of the Neonate and Pediatric Patient.
Dr Chaitanya Vemuri Int.Med M.D Trainee.  The choice of ventilator settings – guided by clearly defined therapeutic end points.  In most of cases :
1 Mosby items and derived items © 2011, 2006 by Mosby, Inc., an affiliate of Elsevier Inc. Chapter 3 Pulmonary Function Study Assessments Pulmonary Function.
Final Considerations in Ventilator Setup Chapter 8.
Basic Pulmonary Mechanics during Mechanical Ventilation
Basic Concepts in Adult Mechanical Ventilation
1 Mosby items and derived items © 2010 by Mosby, Inc., an affiliate of Elsevier Inc. Chapter 14 Respiratory Monitoring in the Intensive Care Unit.
Basic respiratory mechanics relevant for mechanical vnetilation Peter C. Rimensberger Pediatric and Neonatal ICU Department of Pediatrics University Hospital.
Chapter 2 Basic Terms & Concepts of Mechanical Ventilation.
CLINICAL ALGORITHM FOR THE MANAGEMENT OF INTUBATED PATIENTS PRESENTING WITH CHANGES VISSIBLE ON CxR Next step in the algorithm.
BASICS OF WAVEFORM INTERPRETATION Michael Haines, MPH, RRT-NPS, AE-C
Ventilator Management James Eakins, MD FACS Director, Trauma and Surgical Critical Care Hahnemann University Hospital.
Ventilator Graphics Emeritus Professor Georgia State University
Mechanical Ventilation 1
ESSENTIALS OF VENTILATOR GRAPHICS
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
Abby Erickson, RRT Review of RT 110.  Performed by: Hand Machine  Available for: Short term Long term Acute care Extended home care.
Mechanical Ventilation Graphical Assessment
 Understand the dual control concept  Understand the pressure regulation mechanism in PRVC  Demonstration of PRVC  Settings and adjustment with Servo.
L U N G COMPLIANCE ? Physiology Unit.
Ventilatory Modes Graphnet Ventilator.
PRESSURE CONTROL VENTILATION
“Top Twenty” Session Review for Mechanical Ventilation Concepts What you should remember from the Fall… RET 2264C-12.
Ventilators for Interns
Mechanical Ventilation
CLINICAL UTILITY OF VENTILATOR GRAPHICS
VENTILATOR BASICS AND GRAPHICS
Introduction to Basic Waveforms
Ventilator waveform analysis: often ignored bedside assessment
What you should remember from the last week… RET 2264C-10
Basic Concepts in Adult Mechanical Ventilation
Airway pressure and flow waveforms during constant flow volume control ventilation, illustrating the effect of an end-inspiratory breath-hold. Airway pressure.
Adjusting comfort settings on Newport HT70 Series Ventilators
Practical assessment of respiratory mechanics
B. Pearce, G.B. Drummond  British Journal of Anaesthesia 
Pressure-controlled ventilation improves oxygenation during laparoscopic obesity surgery compared with volume-controlled ventilation  P. Cadi, T. Guenoun,
The peak flows (60 L/min) and flow patterns are the same for all the breaths. The peak flows (60 L/min) and flow patterns are the same for all the breaths.
Pumping up the Pressure
Presentation transcript:

Ventilator Graphics Chapter 10

Graphics Monitor the function of the ventilator Evaluate the patient’s response to the ventilator Help the clinician adjust the ventilator settings Both scalar and loops –Scalar: pressure volume and flow graphed against time –Loops: two variable plotted on the X and Y axis, pressure vs volume and flow vs volume

Clinical Rounds 10-1, p. 182 A patient is volume ventilated at the following settings: PIP 24cmH2O; Pplat 17cmH2O; Vt 400ml; PEEP 5 cmH2O 1. What is the Pta? 2. What is the Cstat? 3. Flow is about 35L/min, what is the Raw? 4. Is this Raw normal? 1. Pta=PIP-Pplat: =7cmH2O 2. Cstat=Vt/Pplat-PEEP: 400/17-5= 33.3ml/cmH2O 3. Raw=Pta/flow: 7/(35/60)=12cmH2O/L/s 4. The patient has increased Raw

Key Points for Volume Ventilation Graphics Observing PIP, Pplat, Pta, PEEP on the pressure-time scalar On flow-time scalars locating the beginning of inspiration, the set flow, the beginning of exhalation, PEFR, end-expiratory flow, and the end of exhalation Calculating compliance from pressure and flow curves Observing inspiratory flow of zero during inspiratory pause Checking for Raw using Pta and the expiratory flow curve Inadequate sensitivity and inadequate flow and resulting changes in the pressure-time curve Checking for auto-PEEP using the expiratory flow curve Measuring and observing auto-PEEP levels on the pressure-time curve Checking for leaks and for active exhaltion or transducer error in volume-time curves Different flow patterns during volume ventilation

Pressure Ventilation The pressure waveform is rectangular – constant The pressure waveform is not affected by changes in lung characteristics or patient flow demand The rate of flow delivery varies according to the lung characteristics, set pressure and inspiratory effort The flow waveform rises rapidly at the beginning of inspiration and decreases during inspiration (continuously variable decelerating pattern)

Clinical Rounds 10-2 p. 191 A patient with ARDS is on PCV with the following settings PEEP=10; FiO2=.8; IP=18; PIP=28; Vt=350 (down from 450ml) slope set at the slowest possible flow delivery. ABG’s on these settings are 7.28/49/53 (↓O2 ↑CO2 from previous). The RT notices that PIP reaches only 23cmH2O. No leaks are found in the system. What recommendations might be made to improve this patient’s ABG’s? Initially it was considered to increase IP to improve ventilation and the FiO2 to improve oxygenation; but better ventilation is actually accomplished by adjusting the slope to achieve a faster pressure delivery and increase the Vt, the PIP will return to 28 cmH2O and the patient's ABG values will improve without further adjustments Evidence in the waveform with a tapered inspiratory pressure waveform

Figure 4-5 Identification and correction of overdistention as seen in P-V loops Rapid Interpretation of Ventilator Waveforms by Waugh, Deshpande, Harwood

Figure Alveolar pressure plotted (manually) at various volumes to Determine the point of alveolar overdistention (upper inflection point) Clinical Application of Mechanical Ventilation by Chang © Delamar 2001

Clinical Applications of Mechanical Ventilation by Chang © Delamar 2001