Chronic Hemodialysis Catheters  In site greater than 3 weeks  Tunneled under the skin  Attached felt cuff  Indicated for acute, chronic hemodialysis,

Slides:



Advertisements
Similar presentations
Dialysis Access.
Advertisements

Product Training - Raj Sarkar, PM OsteoFlap ® System Overview.
Mechanical Workshop Module 6: Drilling.
NUR 141: SKILL 28-4: CHANGING INFUSION TUBING
MUNCHY THE CATERPILLAR PRODUCT RELEASE DOCUMENT TM.
Bringing Solutions to Vascular Medicine ML2303 Rev A 10/10.
Introducing…. Zafety Lug Lock ® Wheel Nut Security System.
On the CUSP: STOP BSI Central Line Dressing Change
Expect More. World’s leader in pressure technology NA Sales Training Rev B – 10/10/13.
Urinary – Nephrostomy Catheter Care
Access n If you don’t have it you might as well go home. n This is the most important aspect of CRRT therapy. n Adequacy. n Filter life. n Increased blood.
Single Needle Hemodialysis
Infusion Therapy.
Innovative Minimally Invasive Circulatory Assist Device.
Peritoneal Dialysis PD Access. Peritoneal Dialysis Peritoneal Catheters  PD catheter is patients lifeline  Several advances have made access safer and.
“ Surgical Drains” Professor Magdy Amin RIAD Professor of Otolaryngology. Ain shames University Senior Lecturer in Otolaryngology University of Dundee.
 Introduced in early 1980s  Allow medications to be delivered directly into larger veins  Less likely to clot  Can be left in for longer periods of.
Advanced IV Access.
Stacey Sever, BSN RN CEN Clinical Nurse Educator Emergency Department Providence Alaska Medical Center With thanks to James Booth, MD, Kevin Ellis, RN,
Ergonomic Housing improvements to Personal Smoke Monitoring Device Team: Evan Wozniak Sarah Kostuk Christina Smith Aaron Prahst Multidisciplinary Senior.
Θεματική ενότητα: Stenting
Vascular Access for CRRT Timothy E Bunchman Professor & Director Helen DeVos Children’s Hospital Grand Rapids, MI (Thanks to Rick Hackbarth MD for his.
Nursing Instructions for the Tru-Close® Suction Drainage System
PRPEARED BY : SALWA MAGHRABI CLINICAL INSTRUCTOR
Die Cast – Nickel Die Cast – Black Metalized Plastic Black Plastic Grey Plastic Plastic - Assorted Colors –Available only on 972 Series.
2007 Michell Medal Oration F-111 Structural Integrity Support Francis Rose Chief Scientist, Platforms Sciences Lab, DSTO.
Quality Reliable Safe July 2007 Medical Devices Division Features and Benefits Easy Glide® Easy Glide® Premium Nasogastric Weighted Feeding Tubes.
Quality Reliable Safe July 2007 Medical Devices Division Features and Benefits Surgi-Press® Infuser.
Implementation in practice
Originally Created By: Sheila Elliott MN, RN Revised By: Tina Haayer, RN, BScN.
Abstract Many people, especially elderly individuals, have afflictions such as tremors, loss of dexterity, arthritis, and Multiple Sclerosis, which inhibit.
Access in Pediatric CRRT
Care of patient with CVC
Implanted Ports: Procedure for Access and Care
By Denise Dixon. Catheter related blood stream infections (CRBSI) is a problem in our healthcare. Many clinicians and patients struggle to over come this.
Quality Reliable Safe July 2007 Medical Devices Division Features and Benefits Combiguard II® High Pressure Irrigation Splash Guard Combiport® Wound Irrigation.
Infusion Therapy.
Product Training Europe July 2002
Quality Reliable Safe July 2007 Medical Devices Division Features and Benefits Surgi-Cuff® Surgi-Cuff® Adult and Infant Disposable Blood Pressure Cuffs.
Vascular Access Considerations and Options for Pediatric CRRT Stuart L. Goldstein, MD.
Quality Reliable Safe July 2007 Medical Devices Division Features and Benefits Surgi-Kit® Surgi-Kit® Lap-Kit® Lap-Kit® Surgi-Stuf® Surgi-Stuf®
GRAFT OF DIALYSIS The three most common types of access are:
Vascular Access in CRRT Timothy E Bunchman MD Professor & Director Pediatric Nephrology
Chapter 26. Dialysis PD vs HD 300,000 patients in the US on HD Destination therapy for most patients Increasing rates of DM and HTN in the US Upper extremity.
Intravenous cannulation
FUNCTIONUSERMANUFACTURINGMARKETINGENVIRONMENTALMATERIALS MUST Aid the stability of the kayak both when moving and when stationary. Prevent roll from movement.
Intraosseous Access with the Sternal EZ-IO ® Needle Set.
Concept Generation and Selection of CMT Eating Utensils Submitted to: Dr. Daudi Waryoba Team 5: Nanna Bush, Noah Gordon, Wes Russell Date: February 1,
“Superior Suturing” Suturing Basics Assignment #1
“Superior Suturing” Suturing Basics Assignment #1.
What does that mean? Martha Kliebenstein, MSN, RN Clinical Educator
Central Venous Access Venous Devices
Instrumentation, Equipment, and Supplies
Introducing…. Zafety Lug Lock® Wheel Nut Security System
Safer Sharps Our New Products
“Superior Suturing” Suturing Basics Assignment #1
Access for Pediatric CRRT
“ Surgical Drains”.
Vascular Access and Infused Fluids for Pediatric CRRT
Ariana Kevelier Paul King Building Technology III
PD Catheters Care Plan Kate Oh. The type of material of PD catheter Catheters are made either of polyurethane or silicone rubber Exit-site, antibiotic.
Things You Should Know About Cantilever Rack
Aircast Quick Fit Shoulder Immobilizer
Patient Interface.
SPARK-DUTY™ L – C L A M P S.
Heart Phantom Client: Orhan Unal Advisor: Willis Tompkins
SENIOR DESIGN PROJECT P08455
Access in Pediatric CRRT
SCITEQ End closure series
Θεματική ενότητα: Stenting
Presentation transcript:

Chronic Hemodialysis Catheters  In site greater than 3 weeks  Tunneled under the skin  Attached felt cuff  Indicated for acute, chronic hemodialysis, apheresis and infusion

 QUINTON PermCath  Silicone; Flow Rates 300ml/min - 380ml/min  MAHARKAR 13.5 Fr  Silicone; Flow Rates 300ml/min - 380ml/min  MAHARKAR MAXID Dual Lumen  Proprietary Polyurethane; Flow Rates up to 450ml/min  TANDEM-CATH Catheter System  Proprietary Polyurethane; Flow Rates up to 400ml/min Chronic Hemodialysis Catheters Tyco Healthcare Chronic Catheters

Tyco Healthcare Portfolio Tyco New:MAXID & TANDEM CATH New: TANDEM CATH Tyco MAHURKAR 13.5 PERMCATH MAHURKAR 13.5 PERMCATH New:MAXID

Chronic Hemodialysis Catheters QUINTON PERMCATH

Benefits  Biocompatibility  Will not breakdown over time  Maximizes flow at low pressure  Round lumens provide efficient flow dynamics  Minimizes recirculation Chronic Hemodialysis Catheters QUINTON PERMCARTH Clinical Performance Features  Silicone Material  “Shot Gun” Lumen Design  Staggered Tip Design

Features  Color Coded Ultem Adapters  Clear Silicone Extensions  Durable Inline Clamps Benefits  Damage resistant  Ease of Use  Do not crimp with repeated use  Ensures secure/ready available closure of extensions Chronic Hemodialysis Catheters QUINTON PERMCARTH Safety & Reliability

Features  Suture Wings:  Widely spaced  Low profile  Transparent  Thick Felt Cuff Benefits  Reduces risk of infection  Facilitates skin inspection  Easy to clean  Keeps catheter in place  Reduces infection  Promotes good tissue in growth Chronic Hemodialysis Catheters QUINTON PERMCARTH Safety & Reliability (cont.)

Features  Minimal Side Holes  Repair Kit Benefits  Minimizes clotting  Saves cost & reduces patient trauma Chronic Hemodialysis Catheters QUINTON PERMCARTH Safety & Reliability (cont.)

Features  Printed Priming Volumes  Radiopaque Benefits  Allows for easy visualization of priming volumes for user.  Facilitates quick visualization under X-Ray/fluoroscopy Chronic Hemodialysis Catheters QUINTON PERMCARTH Ease of Use

Chronic Hemodialysis Catheters Mahurkar 13.5

Features  Double “D” Lumen Design  Silicone material  Variety of lengths (4)  Staggered Tip Chronic Hemodialysis Catheters Mahurkar 13.5 Benefits  Maximum flow with low pressure  Biocompatibility  Will not breakdown over time  Fits all size patients  Minimize recirculation Clinical Performance

Features  Color Coded Ultem Adapters  Clear Silicone Extensions  Durable Inline Clamps Benefits  Damage resistant  Ease of Use  Do not crimp with repeated use  Ensures secure/ready available closure of extensions Chronic Hemodialysis Catheters Mahurkar 13.5 Safety & Reliability

Features  Suture Wings:  Widely spaced  Low profile  Transparent  Thick Felt Cuff Benefits  Reduces risk of infection  Facilitates skin inspection  Easy to clean  Keeps catheter in place  Reduces infection  Promotes good tissue in growth Chronic Hemodialysis Catheters Mahurkar 13.5 Safety & Reliability (cont.)

Features  Minimal Side Holes  Repair Kit Benefits  Minimizes clotting  Saves cost & reduces patient trauma Chronic Hemodialysis Catheters Mahurkar 13.5 Safety & Reliability (cont.)

Features  Printed Priming Volumes  Radiopaque Benefits  Allows for easy visualization of priming volumes for user.  Facilitates quick visualization under X-Ray/fluoroscopy Chronic Hemodialysis Catheters Mahurkar 13.5 Ease of Use

Chronic Hemodialysis Catheters Mahurkar MAXID

DESCRIPTION  Chronic-Cuffed (Long-term)  Double “D” Lumen  14.5 Fr. OD  Proprietary Polyurethane  Performance  High Flow (450ml/min)  Kink Resistance

Features  Proprietary Polyurethane Catheter Material  Double "D" Design Benefits  Facilitates percutaneous placement & resists collapse during treatment  Superior kink resistance  Stands up to standard cleansing with PVD – Iodine and Others  Most efficient flow to pressure ratios for polyurethane catheters Chronic Hemodialysis Catheters Mahurkar MAXID Clinical Performance

Features  14.5Fr Outer Diameter  Staggered Tip Benefits  Provides high flows (up to 450ml/min) at low venous and arterial pressures  Low recirculation rate Chronic Hemodialysis Catheters Mahurkar MAXID Clinical Performance (cont.)

Features  Two Side Hole Configurations:  with side holes  without side holes  Transparent Suture Wings  Straight or Curved Silicone Extensions Benefits  Provides choice of design  May enhance patency and minimize clothing  Facilitates skin inspection  Minimizes risk of exit site infection  Increases patient comfort  Allows for numerous insertion sites  Do not crimp with repeated clamping Chronic Hemodialysis Catheters Mahurkar MAXID Safety & Reliability

Features  Durable inline clamps  Thick Felt Cuff  Ultem Adapters Benefits  Ensures secure/readily available closure of extensions  Keeps catheter in place  Reduces infection  Promotes good tissue in growth  Lightweight, durable, and damage resistant Chronic Hemodialysis Catheters Mahurkar MAXID Safety & Reliability (cont.)

Features  Radiopaque  Printed Priming Volumes  StatLock Device Benefits  Facilitates quick visualization under X- Ray/fluoroscopy  Easy maintenance; easy visualization for user  Secures catheter without sutures, may reduce infection Chronic Hemodialysis Catheters Mahurkar MAXID Ease of Use

Features  Variety of Lengths & tip-to-cuff distances  New Tunneler Benefits  Aids in securing the proper catheter for diverse patient sizes  Formable for flexibility in technique  Atraumatic tip and back end minimizes trauma  Easy to grip for ease of insertion Chronic Hemodialysis Catheters Mahurkar MAXID Ease of Use (cont.)

 Two (2) 10Fr independent catheters  Attachable extensions Chronic Hemodialysis Catheters TANDEM-CATH

Features  Proprietary Polyurethane Catheter Material  10 Fr Circular Lumen Design  Individual Tip Placement Benefits  Facilitates percutaneous placement & resists collapse during treatment  Superior kink resistance  Stands up to standard cleansing with PVPI and others  Provides large ID for flows up to 400ml/min. at low arterial and venous pressures  Ability to technically place catheter tips as desired to minimize and optimize flow rates Chronic Hemodialysis Catheters TANDEM-CATH Clinical Performance

Features  Dual Catheters Benefits  Allows for flexible placement  Allows for reverse tunneling  Access flexibility for unique patients  Allows single or dual site insertion  Allows customization of catheter length Chronic Hemodialysis Catheters TANDEM-CATH Clinical Performance (cont.)

Chronic Hemodialysis Catheters TANDEM-CATH Safety & Reliability Features  Two Side Hole Configurations:  with side holes  without side holes Benefits  Provides choice of design  May enhance patency and minimize clotting

Chronic Hemodialysis Catheters TANDEM-CATH Safety & Reliability (cont.) Features  Suture Wing & STATLOCK  Ultem Adapters Benefits  part of the connector housing assembly  Suture holes are small and located on opposite sides of the connector  Statlock securement device locks the catheter in place & minimizes risk of exit site infection  Light weight, durable, and damage resistant

Chronic Hemodialysis Catheters TANDEM-CATH Safety & Reliability (cont.) Features  Radiopaque  Durable inline clamps  Silicone Extensions Benefits  Facilitates quick visualization under x-ray/fluoroscopy  Ensures secure/readily available closure of extensions  Will not crimp over time  Able to visualize fluids

Chronic Hemodialysis Catheters TANDEM-CATH Safety & Reliability (cont.) Features  Thick Felt Cuff  Repair Kit Benefits  Keeps catheter in place  Reduces infection  Promotes good tissue ingrowth  Extension repair kit avoids patient trauma and cost of another surgical procedure. Can typically be done at the bedside. Repair kit is improved over TESIO with silicone extensions vs. polyurethane

Features  StatLock Device  10 Fr Dilator/Sheath  Printed Priming Volumes Benefits  Secures catheter without sutures, may reduce infection  Minimizes overall insertion hole by 0.5Fr vs. the competition  Easy Maintenance Chronic Hemodialysis Catheters TANDEM-CATH Ease of Use

Features  Back-end Assembly Benefits  2-piece assembly vs. 3 pieces of competitor Chronic Hemodialysis Catheters TANDEM-CATH Ease of Use (cont.) TESIO IFU (3- Piece Assembly) TANDEM-CATH IFU (2-Piece Assembly)

Features  C-Clamps Benefits  4 C-clamps in the kit to allow a secure and REMOVABLE clamping and unclamping during each step of assembly Chronic Hemodialysis Catheters TANDEM-CATH Ease of Use (cont.) TESIO IFU (Assembly) TANDEM-CATH IFU (Assembly w/ C-Clamp) Hands- free “C- clamp”

Features  Variety of Lengths & tip-to-cuff distances  New Tunneler Benefits  Aids in securing the proper catheter for diverse patient sizes  Formable for flexibility in technique  Atraumatic tip and back end minimizes trauma  Easy to grip for ease of insertion Chronic Hemodialysis Catheters TANDEM-CATH Ease of Use (cont.)