Automatic Control Systems

Slides:



Advertisements
Similar presentations
Chapter 10 Stability Analysis and Controller Tuning
Advertisements

Chapter 10: Frequency Response Techniques 1 ©2000, John Wiley & Sons, Inc. Nise/Control Systems Engineering, 3/e Chapter 10 Frequency Response Techniques.
Frequency Response Techniques
Chapter 8 Root Locus <<<4.1>>>
Chapter 8 Root Locus and Magnitude-phase Representation
Frequency Response Methods and Stability
Transient and steady state response (cont.)
Modern Control Systems (MCS) Dr. Imtiaz Hussain Assistant Professor URL :
سیستمهای کنترل خطی پاییز 1389 بسم ا... الرحمن الرحيم دکتر حسين بلندي - دکتر سید مجید اسما عیل زاده.
f(t) m x(t) fd(t) LINEAR CONTROL C (Ns/m) k (N/m)
Chapter 5 Frequency-Domain Analysis
Automatic Control Theory-
Automatic Control System
NUAA-Control System Engineering
Feedback Control System THE ROOT-LOCUS DESIGN METHOD Dr.-Ing. Erwin Sitompul Chapter 5
NUAA-Control System Engineering
Frequency Response OBJECTIVE - Bode and Nyquist plots for control analysis - Determination of transfer function - Gain and Phase margins - Stability in.
1.1 Introduction Comparison between ACS and CCS. ACS CCS Process Actuator Measure Controller (correcting network) Structure: Process Actuator Measure.
Ch6 The Root Locus Method. Main content §The Root Locus Concept §The Root Locus Procedure §Generalized root locus or Parameter RL §Parameter design by.
ME375 Handouts - Spring 2002 Root Locus Method.
INC 341PT & BP INC341 Frequency Response Method (continue) Lecture 12.
Fundamentals of PWM Dc-to-Dc Power Conversion Dynamic Performance of PWM Dc-to-Dc Converters.
Chapter 5: Root Locus Nov. 8, Key conditions for Plotting Root Locus Given open-loop transfer function G k (s) Characteristic equation Magnitude.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Frequency Response OBJECTIVE - Bode and Nyquist plots for control analysis - Determination of transfer function - Gain and Phase margins - Stability in.
F REQUENCY -D OMAIN A NALYSIS AND STABILITY DETERMINATION.
Modern Control Systems (MCS) Dr. Imtiaz Hussain Assistant Professor URL :
自动控制原理 西南交通大学电气工程学院 朱英华 (Catherine) The Principle of Automatic Control.
Biomedical Control Systems (BCS) Module Leader: Dr Muhammad Arif muhammadarif Batch: 10 BM Year: 3 rd Term: 2 nd Credit Hours (Theory):
Chapter 10 Frequency Response Techniques Frequency Response Techniques.
Lecture 7 Poles and Zeros Stability. Transfer Function Models General Representation wh where z i are the zeros p i are the poles n ≥ m to have a physically.
Modern Control System EKT 308 Steady-State and Stability.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Review. Feedback Terminology In Block diagrams, we use not the time domain variables, but their Laplace Transforms. Always denote Transforms by (s)!
Chapter 5: Root Locus Nov , Two Conditions for Plotting Root Locus Given open-loop transfer function G k (s) Characteristic equation Magnitude.
Root Locus Techniques (Sketching Method) Date: 25 th September 2008 Prepared by: Megat Syahirul Amin bin Megat Ali
Dr. Tamer Samy Gaafar Automatic Control Theory CSE 322 Lec. 11 Root Locus.
Modern Control System EKT 308 Root Locus Method (contd…)
1 Time Response. CHAPTER Poles and Zeros and System Response. Figure 3.1: (a) System showing input and output; (b) Pole-zero plot of the system;
Exercise 1 (Root Locus) Sketch the root locus for the system shown in Figure K 1 (
Modern Control System EKT 308
Prof. Wahied Gharieb Ali Abdelaal
OBJECTIVE  Determination of root from the characteristic equation by using graphical solution.  Rules on sketching the root locus.  Analysis of closed-loop.
Root Locus. Closed-loop control system with a variable parameter K.
7.1 Root Locus (RL) Principle We introduce the RL through an example. Consider servo motor system shown bellow The closed loop transfer function is motor.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Automatic Control Theory CSE 322
Lecture 16 Bode Analysis, stability, Gain and Phase Margins North China Electric Power University Sun Hairong.
Shroff S.R. Rotary Institute of Chemical Technology Chemical Engineering Instrumentation and process Control.
Control Systems Lect.3 Steady State Error Basil Hamed.
Signals and Systems, 2/E by Simon Haykin and Barry Van Veen Copyright © 2003 John Wiley & Sons. Inc. All rights reserved. Figure 9.1 (p. 664) Two different.
Lecture 11/12 Analysis and design in the time domain using root locus North China Electric Power University Sun Hairong.
1 Chapter 9 Mapping Contours in the s-plane The Nyquist Criterion Relative Stability Gain Margin and Phase Margin PID Controllers in the Frequency Domain.
Intelligent Robot Lab Pusan National University Intelligent Robot Lab Chapter 6. TRANSIENT RESPONSE -- STABILITY Pusan National University Intelligent.
3.0 Time Response OBJECTIVE
Stability Analysis for Control Systems Compiled By: Waqar Ahmed Assistant Professor Mechanical UET, Taxila Compiled By: Waqar Ahmed Assistant Professor.
Digital and Non-Linear Control
Digital and Non-Linear Control
Frequency-Domain Analysis and stability determination
Methods of Determining Stability
Frequency Response Techniques
Frequency Response Techniques
UNIVERSITI MALAYSIA PERLIS SCHOOL OF ELECTRICAL SYSTEM ENGINEERING
Root Locus Techniques CH 8: Islamic University of Gaza
Root-Locus Analysis (2)
Root Locus Techniques CH 8: Islamic University of Gaza
Chapter 2. Mathematical Foundation
Frequency Response Techniques
Methods of Determining Stability
Exercise 1 For the unit step response shown in the following figure, find the transfer function of the system. Also find rise time and settling time. Solution.
Presentation transcript:

Automatic Control Systems

P43 2-6 (a)(e) Find the inverse Laplace transforms of the following functions. Perform partial-fraction expansion on G(s) first ,then use the Laplace transform table. (a) (e)

P70 3-8(b) Find the transfer functions Y2/Y1 and Y1/Y2 of the SFGs shown in Fig.3P-8 Fig.3P-8

P311 7-13 For the control systems shown in Fig.7P-7, find the values of K and Kt so that the maximum overshoot of the output is approximately 4.3 percent and the rise time tr is approximately 0.2 sec. Simulate the systems with any time-response simulation program to check the accuracy of your solutions. Fig.7P-7

P229 6-9 The block diagram of a motor-control system with tachometer feedback is shown in Fig.6P-9.Find the range of the tachometer constant Kt so that the system is asymptotically stable. Fig.6P-9

P230 6-12(a) The conventional Routh-Hurwitz criterion gives information only on the location of the zeros of a polynomial F(s) with respect to the left half and right half of the s-place. Devise a linear transformation s=f (p,α) , where p is a complex variable, so that the Routh- Hurwitz criterion can be applied to determine whether F(s) has zeros to the right of the line s=-α,where αis a positive real number. Apply the transformation to the following characteristic equations to determine how many roots are to the right of the line s=-1 in the s-plane. (a)

P309 7-3(c) Determine the step, ramp, and parabolic error constants of the following unity-feedback control systems. The forward-path transfer functions are given. (c)

P309 7-5 (a) (d) The following transfer functions are given for a single-loop nonunity-feedback control system. Find the steady-state errors due to a unit-step input, a unit-ramp input, and a parabolic input, (a) (d)

Angle of arrival (K<0) and angle of departure (K>0)at s=j. For the loop transfer functions that follows, find the angle of departure or arrival of the root loci at the designated pole or zero. (a) Angle of arrival (K<0) and angle of departure (K>0)at s=j.

(h) Poles at 0, 0, -8, -8; no finite zeros. P347 8-5(h) Construct root-locus diagram for each of the following control systems for which the poles and zeros of G(s)H(s) are given. The characteristic equation is obtained by equating the numerator of 1+ G(s)H(s) to zero. (h) Poles at 0, 0, -8, -8; no finite zeros.

P424 9-9(a) (b) The loop transfer functions L(s) of single –feedback-loop systems are given below. Sketch the Nyquist plot of L(jω) for ω=0 to ω=∞. Determine the stability of the closed-loop system. If the system is unstable, find the number of poles of the closed-loop transfer function that are in the right-half s-plane. Solve for the intersect of L(jω)on the negative real axis of the L(jω)-plane analytically. You may construct the Nyquist plot of L(jω)using any computer program. (a) (b)

P428 9-26(c) The forward-path transfer functions of unity-feedback control systems are given in the following. Plot the Bode diagram of G(jω)/K and do the following: (1) Find the value of K so that the gain margin of the system is 20 dB. (2) Find the value of K so that the phase margin of the system is 45o.