COMPARISON OF DIFFERENT ANALYTICAL TECHNIQUES FOR ENVIRONMENTAL MONITORING OF CONTAMINATED SOILS Metodi Mladenov, Daria Ilieva University of Chemical Technology.

Slides:



Advertisements
Similar presentations
LIMITS OF DETECTION OF AN TOTAL REFLECTION SYSTEM WITH DOUBLE REFLECTION MODULE V. F. Nascimento Filho 1,2, V. H. Poblete 3 P., P. S. Parreira 1,4, E.
Advertisements

BACKGROUND: An American Chrome Plating Company (name withheld by request) performs chrome plating on work rolls which are used in the steel and aluminum.
SIMS-EDX system for a standard-free analysis Yu. Kudriavtsev, R.Asomoza Sección Electrónica del Estado Solido, Departamento Ingeniería Eléctrica, CINVESTAV-IPN,
An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
Analysis of steel and alloys has been a routine affair since hundreds of years. Although most of the methods are documented by ISO, ASTM and BIS, it is.
Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
PROVIDED BY EMAD BEHDAD SPECIALIZED PROTECTION AND CORROSION OF MATERIALS LECTURERS H.MONAJATI,PHD JAFARI,PHD ISLAMIC AZAD UNIVERSITY OF NAJAFABAD BARANCH.
Base metals recovery from zinc hydrometallurgical plant residues by digestion method R. B. Ngenda (1), P. K. Kongolo (1) and L. Segers (2) (1) University.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
CHEMISTRY ANALYTICAL CHEMISTRY Fall Lecture 1.
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Wolff, John A. and Conrey, Richard M. GeoAnalytical Laboratory School of Earth and Environmental Sciences Washington State University Pullman, WA
Instrumental Chemistry Chapter 11 Atomic Mass Spectrometry.
X Ray Flouresence Analysis (XRF). XRF X-Ray Fluorescence is used to identify and measure the concentration of elements in a sample X-Ray Fluorescence.
Trace Metal Analysis of Sediments in the Park River Watershed, Hartford, CT Jonathan Gourley and Victoria Doñé Environmental Science Program Trinity College,
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
NON DESTRUCTIVE CHEMICAL ANALYSIS
Field Methods XRF Copyright © 2013 by DBS. Atomic Spectroscopy for Metal Analysis Introduction to the Principles of Atomic Spectroscopy Atomic spectroscopy:
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Introduction to X-Ray Fluorescence Analysis.
X-Ray Fluorescence Analysis by Gergana Hristozova Project supervisor: s. eng. M. Gustova FLNR.
Seminar Author: Bojan Hiti Mentor: doc. dr. Matjaž Kavčič Determination of trace impurities on Si wafers with x-ray fluorescence.
Total X-ray Fluorescence Spectroscopy (TXRF) Contact: World Agroforestry Centre (ICRAF), P.O. Box Nairobi, Kenya. Tel:
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
CH915: Elemental Analysis
Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) Figure 1. The Varian Vista-PRO CCD Simultaneous ICP-OES in the Physical Geography laboratories.
in tin pest and pest free Monika Leodolter-Dvorak and Ilse Steffan
Analysis of Wear Metals in Lubricating Oil ICP-OES & ASTM Methodology Advanced Research Center 106 Access Rd, Suite 3 Norwood, MA Slide.
Distributions of 3,3 ’,4,4 ’,5-PeXB in FeCl 3 tetra-, penta-, hexa-, and hepta-XB. in FeCl 3 Etching liquid Etching waste Steel plant converter dust iron.
Atomic Absorption Spectroscopy
Chapter 12 Atomic X-Ray Spectroscopy
Atomic Absorption Spectrometry
Significance Caffeine and ibuprofen may negatively affect plant growth.  Caffeine and ibuprofen generally exist at concentrations below 1 ppm in surface.
Lecture 7: Digestion of Samples Digestion of water samples with Kjeldhl method for determination of N Destruction and extraction of soil and sludge for.
Elemental Analysis of Colorectal Cancerous Samples using XRF Techniques A Biophysics Project for SESAME JSPS ’ 02 Al Balqa Applied University Salt Jordan.
EXTRACTION OF COPPER, ZINC AND IRON FROM HYDROCHLORIC ACID SOLUTIONS BY MEANS OF BIFUNCTIONAL EXTRACTANT KELEX 100 Svetlana Zhivkova and George Kyuchoukov.
BIONAD 18 Month Meeting July 7th, 2015, Inescop Premises, Elda (E) LIFE12 ENV/IT/352 Determination of trace elements in traditional dyes, naturalized dyes.
1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.
The analytical techniques most widespread for certification in the iron and steel industry are X-ray Fluorescence Spectrometry (XRF), Arc/Spark Optical.
Gyengnam Public Health & Environmental Research Institute Gang-Ja Ha*, Hwan-Ju Choi, Ho-Hyek Chung, Hwang- Chan Bae, Young-Rok Kim, Jong-Hwa Chung Trace.
LIFE12 ENV/IT/352 Determination of trace elements in commercial dyes, crude chromophore, purified dyes and naturalized dyes Alessandro D’Ulivo BIONAD 24.
Chapter 1: The Nature of Analytical Chemistry
M O N T E N E G R O Negotiating Team for the Accession of Montenegro to the European Union Working Group for Chapter 27 – Environment Bilateral screening:
1 / 18 Organisation Internationale de Métrologie Légale International Organization of Legal Metrology OIML Measurements for environmental regulations J.F.
Томск, ТПУ, ИГНД, ГЭГХ1 Methods of radioactive ores and minerals investigation Volostnov Alexander Valerievich.
EBB 245. Materials Characterisation Lecture 3 X-ray Fluorescence Spectrometry (XRF) Dr Zainovia Lockman PPKBSM, USM (lecture presentations/notes.
Chapter 1 Introduction Tianjin Polytechnic University LIU WEI
M. Fernández, E. Conde, A.I. Barrado Department of Technology
The XRF determination of sulphur in iron oxide.
Lecture 1 contents The nature of analytical chemistry.
Flame Emission Spectrometry
Results Objective Assess the effects of metal interactions on trace metal uptake by plant Evaluate the effects of plant uptake process on the distribution.
COMPARISON OF EXCITATION CONDITIONS IN
Elemental analysis of glass by laser ablation inductively coupled plasma optical emission spectrometry (LA-ICP-OES)  Emily R. Schenk, José R. Almirall 
HEAVY METAL SOLUBILITY AND MOBILITY IN HUMUS LAYERS IMPACTED BY COPPER INDUSTRY IN SOUTH - WEST POLAND Agnieszka Medyńska-Juraszek, Cezary Kabała Institute.
Atomic emission spectrometry
Instrument Parameters in WDXRF
آزمایشگاه فارماکولوژی و سم شناسی
Instrumental Chemistry
T. Gusarova, B. Lange, H. Kipphardt, R. Matschat and U. Panne
Quantifying the Efficiency of Different Solid Sample Digestion Methods: A Comparison of Time, Cost, and Accuracy Connie Hayes.
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
X-RAY FLUORESCENCE TECHNIQUE EMMANUEL A. BAMIDELE.
Airborne Contaminants from Mining Operations In Arizona
ICP-OES ANALYSIS METHOD DEVELOPMENT FOR MINE WASTES
SEM and EDX study of Stainless Steels, Suggested as Biomaterials
Table 6. Bioaccumulation factors for heavy metals in rice crop
Presentation transcript:

COMPARISON OF DIFFERENT ANALYTICAL TECHNIQUES FOR ENVIRONMENTAL MONITORING OF CONTAMINATED SOILS Metodi Mladenov, Daria Ilieva University of Chemical Technology and Metallurgy – Sofia, Bulgaria, 1756, Sofia, 8 “St. Kliment Ohridski” blvd., Fig. 1. Scheme of principle work of ICP-OES spectrometer Experimental Nineteen samples from region of old metallurgical plant, which proven are contaminated with heavy metals and metalloids, are analyzed. The presence and concentrations of elements Cu, Fe, Mn, Pb, As, Zn, Ni and Cr, through “aqua regia” extraction and ICP-OES analysis and XRF analysis are investigated. Schemes of principal work of the two techniques are showed on figs. 1 and 2. Comparison of the performances of the two used method is showed in Table 1. The sampling and sample preparation for XRF analysis are detailed in [1]. The samples were analysed with a Carl Zeiss, Jena (Germany) “VRA 20” wavelength-dispersive XRF spectrometer. Working conditions: X-ray tube with Rh anode; current 50 mA; voltage 35 kV; crystalline analyzer LiF 200 ; detector SC and FC; collimator 0.70; measuring time of each step 30 s; measuring reiteration 3 times. For the quantitative analysis measurements were performed at the characteristic line for each analyte [2]. The extraction with “aqua regia” solution was done according to [3]. It was used Prodigy ICP_OES, Teledyne, Leeman Labs apparatus with next plasma operation conditions: coolant gas – 18 L/min; auxiliary gas – 0.5 L/min; nebulizer gas – psi; power – 1,2 kW; sample uptake time – 30 sec. Results Obtained intervals for results from both methods are showed in table 2. Obtained results haven’t good accordance between themselves. The reason for that can be contain in a different sample preparation procedure for both method. Acknowledgements This poster has been produced with the financial assistance of the European Social Fund, project number BG051PO The author is responsible for the content of this material, and under no circumstances can be considered as an official position of the European Union and the Ministry of Education and Science of Bulgaria References 1.Mladenov M., Jordanov J., Pelovski Y., X-ray spectroscopy analysis of soils in the region of “Eliseina” metallurgical plant, Journal of Environmental Protection and Ecology (2010) 11 (4), Mladenov M., Jordanov J., Ivanova E., X-ray spectroscopy analysis of soils in the region of Eliseina metallurgical plant – Part 2, Journal of Environmental Protection and Ecology (2012) 13 (3A), ISO :1995. Soil quality – Extraction of trace elements soluble in aqua regia. *The new apparatus for WD-XRF have comparable instrumental performance with used in current analysis ICP-OES technique. ** time for five parallel measurements of one sample. On the basis of the obtained results, next conclusions may be drawn: -The obtained results from the two methods are with good accordance for elements As, Zn, Ni and Mn. -Sample preparation for ICP-OES analysis needs from special treatment, which not every time is appropriate for treatment of the analyzed soil samples. For example when the carbonate soils are treated often it is necessary double portion of aqua regia to be used. -Used ICP-OES analysis have very high accuracy, high sensitivity and scale of operation up to ppm, which is advantage to the used apparatus for WD- XRF. That advantage can be equalize if for WD-XRF analysis s use new generation of apparatus. -Even used old generation of apparatus for WD-XRF analysis, the advantages of this analysis is consist in lower time for sample preparation and elimination of error which can be permit form stage of extraction. Introduction Environmental monitoring of contaminated soils is a different task, because of the using of different analytical techniques for analysis depending on the type of the contaminants. There are many types of analysis which are used for preparation of the samples. Still the most used and standardized in many countries is method for extraction with “aqua regia”, and next analysis through inductively coupled plasma (ICP) technique. Some other analytical technique is the wave dispersive X-ray fluorescence (WD-XRF) analysis. That method has very high possibilities for determination of concentration of heavy metals and metalloids in different kinds of samples and has some advantages over the other analytical methods. In current work the done experiments for environmental monitoring of contaminated soil are described. The presence and concentrations of elements Cu, Fe, Mn, Pb, As, Zn, Ni and Cr, through “aqua regia” extraction and ICP-OES (optical emission spectrometry) analysis and WD-XRF analysis are investigated. Table 2. Obtained intervals of concentrations by the two methods. Fig. 2. Scheme of principle work of WD-XRF spectrometer PerformanceMethod Aqua reqia extraction with next ICP-OES analysis WD-XRF analysis* AccuracyUp to % for ICPUp to 0.01 % PrecisionVery good SensitivityUp to %Up to 0.01 % SelectivityVery highVery high for elements with atom number up to 15 Scale of operationFrom ppm to 100 %From 0.02 to 100 % Extraction of the sample in liquid YesNot necessary Time for sample preparation hours15-30 min Time for analysis**30 min Error possibilityHigh – mainly in the sample preparation stage Lower – it haven’t some extraction procedure Table 1. Comparison of performances of the used methods in analysis of current samples ElementICP-OES, %WD-XRF, % As0.001 – 0.21< 0.01 – 0.23 Cu0.005 – – 0.47 Cr0.002 – – 0.06 Ni0.001 – – 0.03 Pb0.005 – 0.05< 0.01 – 0.16 Zn0.01 – – 0.08 Mn0.03 – – 0.12 Fe-1.23 – 3.72