Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.

Slides:



Advertisements
Similar presentations
Add Doors to Open Multi-deck Cases: Provisional UES RTF Meeting August 30,
Advertisements

Energy Sub-Metering for Measurement and Verification
Partnership Gwinnett + Southeast Green Series- Debunking Energy Efficiency Myths: Why your bottom line depends on Energy Efficiency Property of VIS VIVA.
Emerging Technology Field Test 1 February 5, 2015 Brown Bag Mira Vowles, BPA Wesley Saway, BPA.
Smart Devices. Smart Buildings. Smart Business The Potential for DCx Technology Enabled HVAC Operation Scot Duncan, P.E.
BPA Guidelines for Measurement & Verification of Energy Efficiency Measures Presented at Brown Bag Session November 29, 2006.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
Advanced Rooftop-Unit Control – Retrofit Savings Analysis Overview 1 February 13, 2015 RTF Commercial Rooftop-Unit Working Group Mira Vowles, BPA.
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee September 28, 2011 Mira Vowles, P.E., CEM.
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
VRF for the Seventh Plan Preliminary Approach and Data for a Variable Refrigerant Flow Measure for the Seventh Plan Regional Technical Forum January 21,
Floating Head Pressure for Refrigeration Single Compressor Systems Michele Friedrich, PE – Sr. Engineer Dustin Bailey – Engineer PECI 11/2/2010.
CNN Center John Hester Turner Properties, Inc.. CNN Center Built in ,583,000 square feet on 18 floors Five structures joined by a common atrium.
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee April 25, 2012 Mira Vowles, P.E., CEM Emerging.
Premium Rooftop Unit (RTU) Retrofit Overview August 20, 2012 RTF RTU Working Group Mira Vowles, BPA 1.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Emerging Technology Update Presented To Conservation Resources Advisory Committee June 4, 2014.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee November 16, 2011 Mira Vowles, P.E., CEM.
Retrofit Doors to Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
EvergreenEcon.com Heat Pump Water Heater Model Validation, Market Progress Assessment, and Process Evaluation RTF HPWH Sub-Committee Meeting October 15,
Prioritization of VC HP Measures Variable Capacity Heat Pump Measure RTF Sub-Committee June 22, 2011 meeting.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee March 27, 2013 Mira Vowles, P.E., CEM Emerging.
Foothill College & Space Science Center Bill Kelly Viron Energy Services (510) ext 13,
EnergySmart Grocer Program Evaluation Findings Summary PWP, Inc.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Energy Efficient Block Heater Brown Bag BPA Energy Efficiency 4/15/14.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Smart Power Strips in Commercial Office Applications RTF October 4, 2011.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Forecasting and Verifying the Energy Savings for Web-Enabled Thermostats in Portable Classrooms: William E. Koran, P.E. Quantum Energy Services and Technologies.
April, 2002Energy Audits1 April, 2002 Ryan Stroupe, Pacific Energy Center DeAnza College: ES 76 Energy Reliability and Your Organization Energy Auditing.
July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements.
Name of Building(s) or Project Speaker(s) Organization(s)
Anti-Sweat Heater Control Small Saver UES Measure Regional Technical Forum September 17, 2013.
Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009.
BPA M&V Protocols Overview of BPA M&V Protocols and Relationship to RTF Guidelines for Savings and Standard Savings Estimation Protocols.
Forecasting and Verifying Energy Savings for Web-Enabled Thermostats in Portable Classrooms: William E. Koran, P.E. Quantum Energy Services and Technologies.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee June 12, 2014 Mira Vowles, P.E., CEM Emerging.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 27, 2013 Mira Vowles, P.E., CEM.
Evaluation of the RTF Standard Protocol Fan and Cooling Savings from Commercial-Sector Heat Pump Units Rooftop Unit Working Group (RTUG) August 20, 2012.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
Standard Protocol Development for Advanced RTU Control Retrofit August 15, 2013 Presentation to: Regional Technical Forum RTUG Subcommittee Sponsored by:
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump Sub-Committee Alternative Incentive Approaches BPA Energy.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee August 28, 2013 Mira Vowles, P.E., CEM.
Northwest Power and Conservation Council Small Office Savings Analysis Package w/ Lighting Measures Only RTF March 25, 2008.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee September 25, 2013 Mira Vowles, P.E., CEM.
CRAC March 4, Windows Update Regional Technical Forum March 4, 2003.
Energy Cost Budget Highlights Jason Glazer, PE GARD Analytics Arlington Heights, Illinois Energy Cost.
Grocery VSD Measure Deemed Savings Reid Hart, PE & Ken Anderson September 28, 2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee July 24, 2013 Mira Vowles, P.E., CEM Emerging.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Information-Technology RTF Sub-Committee July 2, 2013 Mira Vowles, P.E., CEM Emerging.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Information-Technology RTF Sub-Committee May 7, 2013 Mira Vowles, P.E., CEM Emerging.
Water is the Natural Choice Water: The Natural Choice For Efficiency – Unit efficiency versus Building System efficiency – Equipment Ratings EER and COP.
A Reliable but Simplified Method for Measuring the Savings from Advanced RTU Control Retrofits February 13, 2013 Presentation to: RTF Commercial Rooftop.
Regional Technical Forum Recommissioning commercial retail facilities: A whole building approach to energy savings April 7th, 2009 Presented by: Jeremy.
Kansas City International Airport Michael Glasker, P.E. George Butler Associates, Inc.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump Sub-Committee Road-Mapping Session BPA Energy Efficiency.
VRF Applications in PNW RTF RTUG Meeting October 26, 2011 Kevin Campbell Reid Hart, PE Technical Research Group.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Performance Tested HVAC Presentation to the RTF January 5, 2010.
Wurster Hall MBCx Project October 30th, Project Overview Project Goals Project Objectives Identify Low Cost/No Cost Measures Identify Retrofit.
ECAM M&V Examples For Packaged Equipment Bill Koran, P.E. Director of Energy Analytics, NorthWrite Inc.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Lack of dedicated building meter – Solution: Estimate square footage of Herberger in relation to total area serviced by meter – Estimate 12% of total.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
Product/Service Area : HEATING, VENTILATION, AND AIR CONDITIONING VCHP Energy Efficiency Measure Development Roadmap Barriers Action Items Resources TI.
New Refrigeration Measures -Status Report- & -Request for Input- September 13, 2010.
A Calculator for Reliably Measuring the Savings from Advanced RTU Control Retrofits August 27, 2015 Presentation to: RTF Commercial Rooftop Unit Working.
© 2007, Itron Inc. Statistically Adjusted End-Use Model Overview & Thoughts about Incorporating DSM into a Forecast May 4, 2009 Frank A. Monforte, Ph.D.
Inn at Otter Crest Progress Presentation by Osman Kucuk & Andrey Volodkin Team Members: Natalie Sherwood, Kevin Murray, Lee Han, Huy Tran, Aziz A.
Action Plan for Variable Capacity Heat Pump Technology
Presentation transcript:

Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM Emerging Technology Project Manager BPA Energy Efficiency

Slide 2 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Meeting Agenda 1.VC HP Sub-Committee Overview (Mira) 2.EPRI Lab Testing Results (Ron) 3.Request for PNW VRF project info (Mira) If we have time: –Discuss M&V best practice & standard protocol

Slide 3 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N VRF System Definition Variable refrigerant flow (VRF) systems, either heat-pump or heat-recovery styles, providing heating and air- conditioning, and typically consisting of: 1.Outdoor unit(s) with inverter driven compressor(s) and condenser fan providing improved part-load and low- ambient performance, 2.Multiple indoor units with multi-speed fans, electronic expansion devices, integrated zone temperature controllers and no electric resistance heating capacity, 3. Refrigerant piping between the outdoor and indoor units, 5. Ventilation provided by either natural ventilation or a dedicated outside air system (DOAS).

Slide 4 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Office Building Definition  A building used primarily for office functions, including desk-work, reading and light equipment (computer, copier, printer, telephone, etc.) use.  Office occupancies are further defined by  overall occupant densities between 50 and 300 square feet per person,  overall lighting power densities up to 1 watt per square foot, and  overall equipment plug loads up to 1.5 watts per square foot.

Slide 5 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Building Simulation Program Issues  Due to the complexity of VRF systems (both VRF HR and VRF HP), building simulation programs are needed to estimate site-specific savings;  How can the accuracy of the building simulation programs be verified?  What are the important metrics?  Monthly energy use and average monthly temperature  Other?  Can building simulation programs provide these important metrics for verification purposes?

Slide 6 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N VRF System M&V Best Practice? –Meter baseline and VRF system electricity use for representative period, project to annual savings –Use calibrated Building Simulation model to predict annual savings and monthly electricity use –Verify savings by comparing actual monthly electricity use to predicted monthly electricity use

Slide 7 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N VRF System M&V Standard Protocol? –Use whole building regression analysis spreadsheet with representative period pre- and post- monthly electricity billing data and hourly average OSA temperature, –if savings are temperature dependant, over 15% of whole building electricity use and there are no other significant changes to electricity use, the whole building regression analysis spreadsheet can provide an confidence interval for savings

Slide 8 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Based on Energy Solutions EnergyPro model

Slide 9 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Based on Energy Solutions EnergyPro model

Slide 10 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Use Whole Building Analysis for VRF ROB Electricity Savings M&V? –Energy Solutions EnergyPro model predicts monthly electricity savings ranging between 21 and 33% –For the Small Office (7,200 SF) the monthly electricity savings ranging between 1,900 and 2,200 kWh Next Step: use whole building regression analysis spreadsheet, using EnergyPro model predicted monthly electricity use and Seattle hourly average OSA temperature

Slide 11 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Send PNW VRF project info to Mira at –Project Name –Location –New or Retrofit? –Other changes affecting electricity use? –Building Type –Baseline HVAC –VRF Type (HP or HR) –VRF System Size (tons) –Baseline HVAC System Cost –VRF System Cost ($) –Date of VRF Cx?

Slide 12 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Next Meeting: 3/28/12 at 9 am Potential Topics: –Compile list of PNW VRF installations & brainstorm how to “mine” for useful information –Develop M&V best practice and standard protocol –Develop research plan to verify model accuracy –Compare actual RTU annual fan kWh/SF to models –Develop VRF savings estimates (IEER plus fan?) –NEEA RTU Replacement Discussion