International Conference on Circuits, Systems, Communication & Information Technology Applications, Mumbai, India April 4-5, 2014 (CSCITA-2014) A V ERSATILE.

Slides:



Advertisements
Similar presentations
Georgia Tech Digital Back-end µHRG interface Curtis Mayberry School of Electrical and Computer Engineering Georgia Institute of Technology January 13 th,
Advertisements

Copyright 2001, Agrawal & BushnellVLSI Test: Lecture 181 Lecture 18 DSP-Based Analog Circuit Testing  Definitions  Unit Test Period (UTP)  Correlation.
RF Circuit Design Chris Fuller /7/2012.
ELECTROCARDIOGRAM (ECG)
EE93 – Medical Mobile Devices and Apps
ABSTRACT Annually, heart disease causes over 17 million deaths worldwide. One of the best ways of getting preventive prognoses is to use electrocardiograms.
Data Acquisition Risanuri Hidayat.
Oscilloscope Watch Teardown. Agenda History and General overview Hardware design: – Block diagram and general overview – Choice of the microcontroller.
A Pocket PC Based ECG Monitor Instructor: Professor Chen Sao-Jie Presented by: James Lin 林青頤, R Chiang Yen-an 姜彥安, R Date:June 15, 2004.
A THORACIC IMPEDANCE SIMULATOR FOR IMPEDANCE CARDIOGRAPHY Vinod K Pandey (PhD) Manigandan NS (MTech) Guide: Prof PC Pandey BME Group & EE Dept, IIT Bombay.
The transmission line circuit block used in Cadence Major Blocks and Peak Detector Sections of Channel Equalization Techniques for Ethernet Communication.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
Lecture 31 Electrical Instrumentation. Lecture 32 Electrical Instrumentation Electrical instrumentation is the process of acquiring data about one or.
Lecture161 Instrumentation Prof. Phillips March 14, 2003.
Guitar Effects Processor Critical Design Review October, 07, 2003 Groups Members: Adam Bernstein Hosam Ghaith Jasenko Alagic Matthew Iyer Yousef Alyousef.
EEG Machine By The All-American Boys Featuring Slo- Mo Motaz Alturayef Shawn Arni Adam Bierman Jon Ohman.
© 2012 Pearson Education. Upper Saddle River, NJ, All rights reserved. Electronic Devices, 9th edition Thomas L. Floyd Electronic Devices Ninth.
Introduction to Op Amps
BLDC MOTOR SPEED CONTROL USING EMBEDDED PROCESSOR
Engineering 1040: Mechanisms & Electric Circuits Fall 2011 Introduction to Embedded Systems.
SPI By Alexander Maroudis. Outline What is SPI? SPI Configuration SPI Operation Master Slave Setup SPI Transactions SPI Digital Potentiometer Example.
EKT314/4 Electronic Instrumentation
Vibhuti Bagga1, Tanvi Kalra2, Abhinav 3, Sneh Anand 3
Engineering 1040: Mechanisms & Electric Circuits Winter 2015 Analog & Digital Signals Analog to Digital Conversion (ADC)
09/16/2010© 2010 NTUST Today Course overview and information.
1 Warsaw University of Technology Faculty of Electronics and Information Technology Institute of Electronic Systems HARDWARE SIMULATOR of the high-resolution.
Phase-Locked Loop Design S emiconducto r S imulation L aboratory Phase-locked loops: Building blocks in receivers and other communication electronics Main.
An Embedded Design Example: A Thorax Simulator for Testing and Calibration of Impedance Cardiographs by P. C. Pandey EE Dept., IIT Bombay December 2008.
Team 2 Yimin Xiao Jintao Zhang Bo Yuan Yang.  The project we propose is a digital oscilloscope with playback function that provides almost any function.
Software Defined Radio
National Conference on Virtual and Intelligent Instrumentation (NCVII -09), BITS Pilani, Nov ______________________________________________________________.
Melvin Rivera Suárez Project Manager Alexis Ortiz Pérez Rafael Vega Díaz Wilfredo Bermúdez Soto.
1 Biomedical Embedded Systems Technology Presentation for ENSC 440/305 Instructors: Dr. Andrew Rawicz, Steve Whitmore Department of Engineering Science.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
iitb.ac.in, ee.iitb.ac.in 1/25 Indicon2013, Mumbai, December 2013, Paper ID 1084 Track 4.1 Signal Processing & VLSI (Biomedical.
VLSI and Embedded Systems Conference, 5-9 Jan 2014, IIT Bombay, India (VLSIDES14) Session: B-2 Embedded Platform, Venue: VMCC-21, Session Time: 4:30 pm.
SIGMA-DELTA ADC SD16_A Sigma-Delta ADC Shruthi Sujendra.
Digital Multimeter Introduction 2) DIGITAL MULTIMETER Digital multimeters offer higher accuracy and input impedance, unambiguous readings at greater viewing.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
School of Biomedical Engineering, Science & Health Systems V 2.0 SD [020204] Impedance Cardiography for Non-invasive.
IIT Bombay ● Introduction ● Method ● Results ● ConclusionIntroductionMethodResultsConclusion The International Symposium on Emerging.
IEEE JOURNAL OF SOLID-STATE CIRCUITS, VOL. 50, NO. 3, MARCH 2015 Woojae Lee, Member, IEEE, and SeongHwan Cho, Senior Member, IEEE Chairman: Dr.Shih-Chung.
High-Intensity Focused Ultrasound Therapy Array May1005 Alex Apel Stephen Rashid Justin Robinson.
UCLA IEEE NATCAR 2004 SUMMER CLASS Magnetic Sensors & Power Regulation.
Non-invasive fetal electrocardiogram measurements Adviser :蔡亮宙 Student ;蔡政宏.
Guide Presented by Mr.M Cheenya V.Abhinav Kumar 11E31A0422 Asst.Professor K.Shiva Kumar 11E31A0423 K.Rajashekhar 11E31A0424 K.Chaithanya Sree 11E31A0428.
HOT CAR BABY DETECTOR Group #20 Luis Pabon, Jian Gao ECE 445 Dec. 8, 2014.
Sound Source Location Stand Group 72: Hiroshi Fujii Chase Zhou Bill Wang TA: Katherine O’Kane.
TRANSMISSION LINE MULTIPLE FAULT DETECTION AND INDICATION TO EB
1 Summary Lecture: Part 1 Sensor Readout Electronics and Data Conversion Discovering Sensor Networks: Applications in Structural Health Monitoring.
Arduino based Automatic Temperature Controlled Fan Speed Regulator.
Current Monitor Group (1606) Maya Dubrow Barath Parthasarathy Andrew Pikul Jason Stock.
Emotional Intelligence Vivian Tseng, Matt Palmer, Jonathan Fouk Group #41.
Biomedical Instruments Design Biopotential Amplifiers
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
MECH 373 Instrumentation and Measurements
Chapter 5. Signals and Noise
MECH 373 Instrumentation and Measurements
Analogue Electronics Circuit II EKT 214/4
Analogue Electronic 2 EMT 212
Lecture 1 Technological Principles of Medical Instrumentation
Analog/Digital Hybrid synthesizer
Technological Principles of Medical Instrumentation
Project guide B. SUBBULAKSHMI M. E Assistant Professor C. A. R
BESIII EMC electronics
Amplifiers: A Bio amplifier is an electrophysiological device, a variation of the instrumentation amplifier, used to gather and increase the signal integrity.
Biomedical Instruments Design Biopotential Amplifiers 1.
ECE 3336 Introduction to Circuits & Electronics
Eye Movement Tracking Device Senior Design Project: P09004
Current Monitor Group (1606)
Presentation transcript:

International Conference on Circuits, Systems, Communication & Information Technology Applications, Mumbai, India April 4-5, 2014 (CSCITA-2014) A V ERSATILE N ONINVASIVE B IOIMPEDANCE S ENSOR U SING D IGITAL S YNCHRONOUS D EMODULATION P. C. Pandey IIT Bombay 04/Apr/2014

International Conference on Circuits, Systems, Communication & Information Technology Applications, Mumbai, India April 4-5, 2014 (CSCITA-2014) P. C. Pandey: A versatile noninvasive bioimpedance sensor using digital synchronous demodulation (invited talk) Abstract A noninvasive monitoring of bioimpedance has the potential of serving as a low-cost diagnostic tool and monitoring device in several medical applications, e.g. impedance cardiography (sensing of variation in thoracic impedance to estimate cardiac output and some other hemodynamic parameters), pneumography (sensing of respiratory parameters), plethysmography (sensing of peripheral blood circulation), glottography (sensing of movement of vocal chords), etc. The instrument passes a high-frequency low-amplitude current through an appropriately placed electrode pair, an amplifier to sense the resulting amplitude-modulated voltage across the same or another appropriately placed electrode pair, a demodulator to detect the impedance signal, and signal processing for obtaining the desired parameters. In our work, an embedded system design approach has been used to develop a versatile noninvasive bioimpedance sensor for sensing the basal value of the impedance and the time-varying component of the impedance waveform. A microcontroller and an impedance converter chip are used for providing a stable sinusoidal source with programmable frequency and digital synchronous demodulation for very low noise and demodulation related distortions. A voltage-to-current converter with balanced outputs is designed using two operational trans-conductance amplifiers for current excitation. The sensed voltage is added with a sinusoidal voltage obtained from the excitation source and with digitally controlled amplitude and polarity to increase its modulation index before digital synchronous demodulation and for baseline correction of the sensed impedance signal. Two digital potentiometers are used to provide independent control over current excitation and baseline correction. Synchronous digital demodulation in the impedance converter chip gives real and imaginary part of the impedance. An isolated RS232 interface is provided to set the parameters and to acquire the sensed impedance signal. The design can be used for realizing a body-worn device for monitoring the clinically important hemodynamic parameters during critical care, for ambulatory recording for early diagnosis of cardiovascular disorders and for post-operative care, for monitoring of physiological parameters for use in sports medicine, and as a low-cost diagnostic aid. Dr. P. C. Pandey, Professor, Electrical Engineering, IIT Bombay EE Dept, IIT Bombay, Powai Mumbai , India.

P. C. Pandey, EE Dept., IIT Bombay 3/30 Outline 1.Introduction 2.Hardware & Software 3.Test Results 4.Summary Reference Hitendra Sahu: “Sensing of impedance cardiogram using synchronous demodulation”, M. Tech. dissertation, Biomedical Engineering, Indian Institute of Technology Bombay, June 2013.

P. C. Pandey, EE Dept., IIT Bombay 4/30 1. INTRODUCTION Noninvasive Bioimpedance Monitoring o Low-cost diagnostic tool o Monitoring device Applications o Impedance cardiography: Sensing of variation in thoracic impedance to estimate cardiac output & some other hemodynamic parameters o Pneumography: Sensing of respiratory parameters o Plethysmography: Sensing of peripheral blood circulation o Glottography: Sensing movement of vocal chords during speech production

P. C. Pandey, EE Dept., IIT Bombay 5/30 Instrumentation for Bioimpedance Sensing o Excitation current of high frequency and low amplitude through an appropriately placed pair of electrodes o Amplifier to sense the resulting amplitude modulated voltage across the same or another pair of appropriately placed electrodes o Demodulator to detect the impedance signal o Signal processing for obtaining the desired parameters

P. C. Pandey, EE Dept., IIT Bombay 6/30 ICG blocks AC excitation current Voltage sensing amp. Demodulator Baseline correction ECG extractor Example: Impedance Cardiograph Operation Excitation current: kHz, < 5 mA Amplitude demodulation of the sensed voltage: Z(t) with basal impedance (20 − 200 Ω) & time-varying component (< 0.2 Ω) ICG: − dZ/dt, processed with ECG as the reference.

P. C. Pandey, EE Dept., IIT Bombay 7/30 Objective To develop a body-worn bioimpedance sensing device for Monitoring the clinically important physiological parameters during critical care (multi-channel signal acquisition & processing) Ambulatory recording for early diagnosis of cardiovascular disorders and for post-operative care (recording in the presence of motion artifacts) Monitoring of physiological parameters for use in sports medicine (recording in the presence of external interference, strong respiratory and motion artifacts) Low-cost diagnosis (low distortion & high sensitivity)

P. C. Pandey, EE Dept., IIT Bombay 8/30 Design Approach Digital synchronous demodulation for noise and interference rejection Circuit for increasing the modulation index of the waveform to increase the sensitivity and dynamic range Basic Blocks Microcontroller “Microchip PIC24FJ64GB04” Impedance converter chip “Analog Devices AD5933” V/I convertor and amplitude control Voltage sensing amplifier and baseline correction PC-based GUI with isolated serial communication for setting parameters and data acquisition 2. HARDWARE & SOFTWARE

P. C. Pandey, EE Dept., IIT Bombay 9/30 Impedance Converter AD5933 Features Excitation voltage generator & digital synch. demodulator Programmable voltage with a settable frequency up to 100 kHz Impedance measurement range from 1 kΩ to 10 MΩ Internal system clock DC rejection, error averaging, phase measurement Accuracy: ± 0.5%. I2C interface with a data rate of 100 kHz Adaptations needed for bioimpedance sensing Measurement using current excitation Time-varying measurement Dynamic range extension and sensitivity selection

P. C. Pandey, EE Dept., IIT Bombay 10/30 Functional block diagram of AD5933

P. C. Pandey, EE Dept., IIT Bombay 11/30 Design using the impedance converter chip with on-chip sinusoidal source & DFT for synchronous digital demodulation

P. C. Pandey, EE Dept., IIT Bombay 12/30 Impedance Converter Circuit

P. C. Pandey, EE Dept., IIT Bombay 13/30 Digital pot. AD8400 (U3, U7) used for controlling the amplitudes of the excitation current & baseline correction voltage Resistance: 1 K, 8-bit resolution Wiper position control: SPI interface Supply: 2.6 – 5.5 V

P. C. Pandey, EE Dept., IIT Bombay 14/30 V/I Converter Voltage generated from AD5933 converted to a current using OTA-based V/I converter OTA “TI OPA861” g m : 90 mA/V (quiescent current = 4.7 mA) +5 V single supply operation Bandwidth: 80 MHz

P. C. Pandey, EE Dept., IIT Bombay 15/30 V/I Converter with Balanced Current Outputs Complimentary balanced current outputs, using two OTAs Quiescent current set by R1 and R3 Output current controlled by changing R2 or quiescent current

P. C. Pandey, EE Dept., IIT Bombay 16/30 Voltage Sensing Amplifier Instr. amp. INA155 for amplifying the sensed voltage Bandwidth: 5.5 MHz Gain: 10 – 50 Slew rate: 6.5 V/µs Supply: 2.6 – 5.5 V High-pass filter cut- off: 16 kHz

P. C. Pandey, EE Dept., IIT Bombay 17/30 Baseline Correction Subtracting a sinusoidal reference voltage from the sensed voltage Amplitude and polarity of the correction voltage digitally controlled by varying digital pot (U7) ratio between 0.25 to 0.75 Baseline correction output tracked by microcontroller using ADC. Potentiometer ratio controlled digitally via SPI interface

P. C. Pandey, EE Dept., IIT Bombay 18/30 Demodulation

P. C. Pandey, EE Dept., IIT Bombay 19/30 Microcontroller 44-pin PIC24F64GB004 Supply : 3.0 –3.6 V 16 MHz clock 64 KB program memory 8 KB RAM Single channel 10-bit ADC UART module USB module SPI module I2C module

P. C. Pandey, EE Dept., IIT Bombay 20/30 Power Supply Separate analog & digital 3.3 V & 5 V Analog reference of 1.6 V generated by MCP6021 LDO MCP1802 used as voltage regulator IC Input to the LDO from a DC-DC converter LM2622 Input to the DC-DC converter: V Li-ion charge control IC MCP73833 used for battery charging. Total current consumption: ~60 mA Low battery indication Provision for powering through USB

P. C. Pandey, EE Dept., IIT Bombay 21/30 Power Supply Circuit

P. C. Pandey, EE Dept., IIT Bombay 22/30 Assembly Two-layer PCB (102 mm x 64 mm) with SMD components

P. C. Pandey, EE Dept., IIT Bombay 23/30 Signal Acquisition Interface PC based signal acquisition using RS232

P. C. Pandey, EE Dept., IIT Bombay 24/30 3. TEST RESULTS Exc.: 65.5 kHz, 0.9 mA Lin. range: up to 400 Ω A) Voltage sensing amplifier: output linearity B) Interference Significant only over a bandwidth of 3 kHz

P. C. Pandey, EE Dept., IIT Bombay 25/30 C) Automatic Sensitivity Adjustment Voltage sensing amplifier output vs test resistances for excitation current of 0.6 − 1.5 mA, set by varying β

P. C. Pandey, EE Dept., IIT Bombay 26/30 D) Validation using thoracic impedance simulator Excitation: 0.6 mA, kHz Simulator settings: R = 49 Ω, ∆R = 0.5Ω, f = 1 Hz Sampling freq.: 200 Hz Excitation: 0.6 mA, kHz Simulator settings: R = 20 Ω, ∆R = 0.8 Ω, f = 0.1 Hz Sampling freq.: 10 Hz

P. C. Pandey, EE Dept., IIT Bombay 27/30 Excitation: 0.6 mA, kHz Simulator settings: R = 30 Ω, ∆R = 0.8 Ω, f = 0.1 Hz Sampling freq. : 200 Hz Excitation: 0.6 mA, kHz Simulator settings : R = 19 Ω, ∆R = 0.5 Ω, f = 5 Hz Sampling freq.: 200 Hz

P. C. Pandey, EE Dept., IIT Bombay 28/30 4. SUMMARY Developed A bioimpedance sensor using an impedance converter chip using digital synchronous demodulation Further work Median filtering for further carrier ripple rejection without smearing transitions Adaptation for specific applications Integration with the signal processing software Field testing

P. C. Pandey, EE Dept., IIT Bombay 29/30 References [1]R. P. Patterson, "Fundamentals of impedance cardiography," IEEE Eng. Med. Biol. Mag., vol. 8, no. 1, pp , [2] L. E. Baker, "Applications of impedance technique to the respiratory system," IEEE Eng. Med. Biol. Mag., vol. 8, no. 1, pp. 50–52, [3]L. E. Baker, "Principles of impedance technique," IEEE Eng. Med. Biol. Mag., vol. 8, no. 1, pp. 11–15, [4]H. H. Woltjer, H. J. Bogaard, and P. M. J. M. de Vries, “The technique of impedance cardiography,” Euro. Heart J., vol. 18, no. 9, pp. 1396–1403, [5]M. D. Desai, “Development of an impedance cardiograph,” M. Tech. dissertation, Biomedical Engineering,, IIT Bombay, [6]H. Sahu: “Sensing of impedance cardiogram using synchronous demodulation,” M. Tech. dissertation, Biomedical Engineering, IIT Bombay, June 2013.

P. C. Pandey, EE Dept., IIT Bombay 30/30