TESTING AND COMMISIONING

Slides:



Advertisements
Similar presentations
Chapter 12 Transformers. Chapter 12 Transformers.
Advertisements

Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
MOLDED CASE CIRCUIT BREAKER BASICS
GENERATOR PROTECTION.
PROTECTION scheme for bus bar / feeder
Elec467 Power Machines & Transformers
Static Relays Static relays are those in which the designed response is developed by electronic or magnetic means without mechanical motion. The designation.
Power System Analysis/ Power System 1 EEE 4113/ EEE 3131
Power System Protection
Technician License Course Chapter 3 Electricity, Components and Circuits Lesson Plan Module 6.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
INTRODUCTION TO SWITCHGEARS
Circuit Breakers.
How Coils Work A basic introduction into Coil technology.
Content Types of circuit breakers Operating principles of circuit breakers Inverse time/current characteristic of circuit breakers Circuit breakers.
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
Submitted By Ravi Raj Rajeev Kumar Vipul Batra. FUNCTIONS PERFORMED BY THE RELAY MADE 1.OVER VOLTAGE PROTECTION 2.OVERCURRENT PROTECTION.
Substations. Substations Chapter 4 Substations Major types of equipment found in most transmission and distribution substations with their purpose,
Chapter 7 SYSTEM PROTECTION
Introduction to Robotics Principles of Robotics. What is a robot? The word robot comes from the Czech word for forced labor, or serf. It was introduced.
Chapter 2 Transformers.
Numerical algorithms for power system protection Prof. dr. sc. Ante Marušić, doc. dr. sc. Juraj Havelka University of Zagreb Faculty of Electrical Engineering.
Industrial Machine Control
Lesson 9: Electrical Components
Vidhyadeep Institute Of Management & Technology, Anita, Kim Electronics & Communication Department Guided by Mr. Vicky Paperwala.
Automated Manufacturing Systems
THE RELAY. A Relay is an electromagnetic switch. A Relay is activated when a current is applied to it.
COMPONENTS REQUIRED STEP DOWN PRANSFORMER:
POWER SYSTEM PROTECTION. Power system Generators Transformers Transmission lines »Underground cables »Overhead lines Distribution systems.
POWER SYSTEM PROTECTION
OVER CURRENT RELAY The relay has two settings. These are the time setting and the plug setting. The time setting decides the operating time of the relay.
Analog to Digital conversion. Introduction  The process of converting an analog signal into an equivalent digital signal is known as Analog to Digital.
Need for protection Power system must be kept in operation continuously without major breakdowns This can be achieved in two ways: 1.Implement a system.
Chapter 4 Overload Relays.
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
CIRCUIT BREAKER Definition  Device designed to open the circuit automatically under abnormal conditions without damage to itself.
EE 445 Course Presentation Power System Protection
Control Theory Control System Objectives  Establish a final condition  Provide safe operation  Eliminate the human element  Assure economical operation.
Protection & Switchgear
Lecture 9: Modeling Electromechanical Systems 1.Finish purely electrical systems Modeling in the Laplace domain Loading of cascaded elements 2.Modeling.
Introduction to Power Supplies
Technician License Course Chapter 3 Lesson Plan Module 6 – Part 1 Electrical Components 21 March 2015.
Technician License Course Chapter 3 Lesson Plan Module 6 – Part 2 Electrical Components 28 March 2015 Practice Questions 2014 Technician License Course.
Announcements Read Chapters 10 and 11
Introduction to switchgears
General power system. objective Review general energy and power system Application of fundamental knowledge of principal machines, transformer and other.
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
FUNDAMENTALS OF ELECTRICAL ENGINEERING [ ENT 163 ] LECTURE #10 ELECTRICAL MACHINES HASIMAH ALI Programme of Mechatronics, School of Mechatronics Engineering,
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
Protection of Power Systems
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
EKT 451 CHAPTER 6 Sensor & Transducers.
  The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable.  An MCCB provides.
Power System Protective Relaying-Part One
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
Protection of Power Systems
Vinayan.S Roll no:22 EEE7  Introduction  Saturation in conventional current transformers  Saturated & Non-saturated CT outputs  Problem in Coventional.
Protection and Relay Schemes
Protection of Power Systems
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Chapter 7 System Protection
FAULT ANALYSIS - BALANCED FAULT
General Licensing Class
ELECTRICAL POWER-II Electrical engineering sixth semester
Agenda Introduction of Protective Relays
POWER SYSTEM COMMISSIONING AND MAINTENANCE PRACTICE
POWER SYSTEM COMMISSIONING AND MAINTENANCE PRACTICE
Presentation transcript:

TESTING AND COMMISIONING DET310 CHAPTER 6 PROTECTIVE RELAY

TESTING AND COMMISIONING DET310 6.1 INTRODUCTION -Power systems and their components need protection from natural hazards as well as human error. -Lightning, wind, ice, switching surges, resonance, trees, animals and humans are some of the causes of faults. -These faults produce overcurrents and/or overvoltages at various locations in a power system and must be cleared before they cause before they damage any machines, transformers, lines etc. -This is generally accomplished by isolating the faulted portion (as small a portion as possible) of the system so that the remainder of the system can serve without interruption.

TESTING AND COMMISIONING DET310 -continue: In low-voltage distribution systems, lightning (surge) arresters are used for overvoltage protection and fuses and slow-acting circuit breakers are employed for overcurrent protection. In high-voltage transmission systems reliable sensors, fast-acting relays and circuit breakers are needed to clear the fault quickly so that the stability of the remaining system is secured. - In short, the protection, stability and security of a power system are affected by the ability of the protection devices to detect and respond to system abnormalities like overvoltages and overcurrents

TESTING AND COMMISIONING DET310 6.1 Protection Components Protection systems have three basic components: -Sensors (transducers, detectors) to detect system abnormalities -Relays (activators) to provide signals to activate the protection devices. -Circuit breakers (interrupters) to open (disconnect) the circuits

TESTING AND COMMISIONING DET310 Figure 6.0

TESTING AND COMMISIONING DET310 Continue: In order to perform its functions properly, the protection system must have the following characteristic: Reliability: The reliability of the protection system is its ability to operate upon the occurrence of any fault for which it was designed to protect. In other words, the protection system should operate when it is supposed to and not operate when it is not required. Selectivity: Selectivity is the ability of the protection system to detect a fault, identify the point at which the fault occurred and isolate the faulted circuit element by tripping the minimum number of circuit breakers. Selectivity of the protection system is obtained by proper coordination of the operating currents and time delays of the protective relays.

TESTING AND COMMISIONING DET310 6.2 CLASSIFICATIONS OF RELAYS Relays may be classified according to the technology used: a. electromechanical b. static c. digital d. numerical

TESTING AND COMMISIONING DET310 Continue: c) Speed: The speed of the protection system refers to the operating times of the protective relay. The potential damage to the faulted element depends on the length of time the short-circuit currents are allowed to flow. The speed of clearing or isolating the faulted system component also affects the stability of the whole system. d) Sensitivity: Sensitivity refers to the characteristic of a protective relay that it operates reliably, when required, in response to a fault that produces the minimum short-circuit current flowing through the relay.

TESTING AND COMMISIONING DET310 6.2.1 ELECTROMECHANICAL RELAYS Electromechanical relays can be classified into several different types as follows: attracted armature – comprises of iron cored electromagnet which attracts an armature which is pivoted, hinged or supported. b. moving coil- light coil which can be energised moves in a strong permanent magnet field. c. Induction – operated on the same principle as the induction motor d. Thermal – operates based on the generated heats in a resistance winding and temperature sensitive component e. Timing relays- are used in conjunction with protection relays

TESTING AND COMMISIONING DET310 6.2.2 Static Relays -The term ‘static’ implies that the relay has no moving parts. -In a protection relay, the term ‘static’ refers to the absence of moving parts to create the relay characteristic. -Their design is based on the use of analogue electronic devices instead of coils and magnets to create the relay characteristic. -Early versions used discrete devices such as transistors and diodes in conjunction with resistors,capacitors, inductors, - Advance versions enabled the use of linear and digital integrated circuits in later versions for signal processing and implementation of logic functions.

TESTING AND COMMISIONING DET310 6.2.3 Digital Relays -Digital protection relays introduced a step change in technology. Microprocessors and microcontrollers replaced analogue circuits used in static relays to implement relay functions. Compared to static relays, digital relays introduce A/D conversion of all measured analogue quantities and use a microprocessor to implement the protection algorithm. -The microprocessor may use some kind of counting technique, or use the Discrete Fourier Transform (DFT) to implement the algorithm.

TESTING AND COMMISIONING DET310 6.2.4 Numerical Relays Typically, they use a specialised digital signal processor (DSP) as the computational hardware, together with the associated software tools. - The input analogue signals are converted into a digital representation and processed according to the appropriate mathematical algorithm. - Processing is carried out using a specialised microprocessor that is optimised for signal processing applications, known as a digital signal processor

TESTING AND COMMISIONING DET310

TESTING AND COMMISIONING DET310

TESTING AND COMMISIONING DET310 6.3 Zone of Protection To limit the extent of the power system that is disconnected when a fault occurs, protection is arranged in zones.(Figure 6.1). Ideally, the zones of protection should overlap, so that no part of the power system is left unprotected. (Figure 6.2).

TESTING AND COMMISIONING DET310 Figure 6.1

TESTING AND COMMISIONING DET310 Figure 6.2

TESTING AND COMMISIONING DET310 6.4 Protection principles The best and common protection techniques can be classified into 2 categories a) Overcurrent/earth fault-distance protection b) Differential protection

TESTING AND COMMISIONING DET310 6.4.1 Overcurrent and Earth-fault Protection Protection against excess current was naturally the earliest protection system to evolve. The actuating quantity of an overcurrent relay is a current. The relay is designed to operate when the actuating quantity equals or exceeds its pickup value. An overcurrent relay can either be an instantaneous type or a time-delay type.

TESTING AND COMMISIONING DET310 6.4.1.1 IDMTL relay Most commonly used type of relay. Characteristics of relay is the higher the current, the shorter the operating time. The current/time tripping characteristics of IDMT relays may need to be varied according to the tripping time required and the characteristics of other protection devices used in the network. IEC 60255 defines a number of standard characteristics as follows: a) Standard Inverse (SI) b) Very Inverse (VI) c) Extremely Inverse (EI) d) Definite Time (DT)

TESTING AND COMMISIONING DET310

TESTING AND COMMISIONING DET310 The tripping characteristics for different TMS settings using the SI curve

TESTING AND COMMISIONING DET310 6.4.1.2 Setting of IDMTL relays In order to adjust the current setting, the relay coil is arranged to have a tapped winding which is connected to a plug bridge. (electromechanical relay) In modern relays, it is known as PLUG SETTING MULTIPLIER. Example: if Tap is set at 80% of 5A, then the current into the relay is 0.8 x 5A = 4A. TIME MULTIPLIER SETTING (TMS) the time the relay disc to move through 180 degrees or relay operates to trip - The setting is in term of percentage such as 10 %(0.1), 20%(0.2), 30% (0.3) etc.

TESTING AND COMMISIONING DET310 Continue: Tripping time of standard overcurrent relay: Where: TMS = time multiplier setting

TESTING AND COMMISIONING DET310 Example: Calculate tripping time of an overcurrent relay at 150% with the The PSM setting is at 80%. CT ratio connected to the CT is 1000/5A The TMS setting is 0.1 Solutions: Time, t = 1.72 s

TESTING AND COMMISIONING DET310 6.5 RELAY TESTING AND COMMISIONING

TESTING AND COMMISIONING DET310 Continue: Tripping time of standard overcurrent relay: Where: TMS = time multiplier setting

TESTING AND COMMISIONING DET310 Continue: Tripping time of standard overcurrent relay: Where: TMS = time multiplier setting