3M™ Novec 1230™ Fire Protection Fluid

Slides:



Advertisements
Similar presentations
SCS East Region Safety & Health
Advertisements

Halon Replacement for Airplane Cargo Compartments What it Takes Fourth Triennial International Fire and Cabin Safety Research Conference Lisbon, Portugal.
Carbon Dioxide Systems 1.Carbon dioxide properties 2.Storage 3.Uses 4.Limitations 5.Types of systems 6.Local Application 7.Total Flood.
A new opportunity from 3M 3M™ Novec™ 1230 Fire Protection Fluid Sustainable technology for special hazards A new opportunity from 3M Today, I.
Fire Safety & Fire Extinguisher Use
COMPRESSED GASES. Compressed Gases Chemicals include oxygen, argon, nitrogen, helium, acetylene, hydrogen, nitrous oxide, carbon dioxide, ammonia, chlorine,
EXTINGUISHER BASICS D INTRODUCE YOURSELF. REMIND STUDENTS ABOUT:
Fire Prevention & Protection Gordon Cooper Technology Center
Halon Systems Ch. 5, pages HALogenated hydrocarbON not the same as halogen F, Cl, Br, I 1940’s ’s extremely effective.
© Siemens Industry, Inc Confidential / Drive Your Business Forward Ignite the Power of New Products and Partnerships Siemens Fire Partner Summit.
Viking TotalPac2 FireFlex Dual / 1230
Local Application Total Flooding System: (NFPA 12) A system consisting of a supply of carbon dioxide arranged to discharge into, and fill to the proper.
PORTABLE& OTHER FIRE EXTINGUISHING SYSTEM Fire extinguisher= Is a device within its chemical, fluids,& gases for extinguishing and used for small area.
Stages of Fire Detections and Extinguishants From Ginge-Kerr Danmark A/s & BMTT Corporation S/B (www. ginge-kerr.com)
FIRE SAFETY TRAINING THE LOSS PREVENTION UNIT OF THE OFFICE OF RISK MANAGEMENT.
Total Flooding Systems
Sustainability of Special Hazards Fire Suppression Systems
In today’s global business environment, the need for clean agent fire suppression has never been greater. Pem All.
Fire Safety & Fire Extinguisher Use. OBJECTIVES Understand the combustion process and different fire classes Understand fire extinguisher types, operating.
Portable Fire Extinguishers Selection and Placement University Safety Council April 19, 2006 Steven G. Triebold Fire Prevention and Protection Program.
Clean Agent Fire Suppression Alternatives
Fire Suppression Systems Association PRESENTS:
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
WELCOME The Fixed Fire Suppression Systems. We carry out the supply installation & Annual required maintenance in regard to the fixed.
Control Rooms  Serve as operations centers for the control and monitoring of a service or process  Flight control rooms  Power generation control rooms.
Laboratory Safety-Flammable Liquids Flammable Liquids and Fire Codes for Laboratories.
 OSHA - (Occupational Safety & Health Administration) This is a governmental regulatory body to ensure safe working and learning environments for Americans.
NFPA-12 Edition 2005 What “IMPACT” will the changes to NFPA-12 have on the design and installation of a CO 2 system?
Inert Gas Fire Extinguishants
Kidde Engineered Fire Suppression System 25 bar Equipment Hardware Engineered for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Patrick Thornton, SNS/FPE June 9, 2008
CXS490 Chemical Extinguishing System Halocarbon Extinguishing System
Petroleum Production Fire Suppression
SINORIXTM CDT Product Presentation.
NEXT GENERATION Kidde Engineered Fire Suppression System Designed for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Novec 1230™ SYSTEM DESIGN 3M™ Novec 1230™ Fire Protection Fluid.
Argonite Fire Extinguishing System
CXS490 Carbon Dioxide Systems
ALTERNATIVE AGENT UPDATE Louise C. Speitel Fire Safety Branch AAR-440 FAA W.J. Hughes Technical Center Atlantic City International Airport, NJ
Federal Aviation Administration Status of Research & Testing to Replace Halon Extinguishing Agents in Civil Aviation Fire Safety Team FAA Wm. J. Hughes.
1 CXS490 - Characteristic of Fire. 2 Other Resources NFPA Standards (available through Seneca Libraries Link NFPA Handbook Manufacturer’s Technical Information.
Fire Suppression. Your role in fire safety Put out small fires Put out small fires Prevent additional fires Prevent additional fires Shutoff utilities.
5.1.6 Student Book © 2005 Propane Education & Research CouncilPage 1 Selection of proper dispenser transfer hoses, end valves and adapters relies on a.
The work of CEN/TC 305 Potentially explosive atmospheres-
FIRE SERVICES AT DATA CENTRE
1 CXS490 - Pre-Engineered Fire Protection Systems Off-Road Vehicle Systems.
Kidde FM-200® Product Review
NOVEC Fire Suppression System
ADS / PHX SERIES SYSTEMS DESIGN
2012 Lik Kai Pacific Sense March PACIFIC SENSE Company Intro.
California Lutheran university Fire Extinguisher Training.
Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration WJ Hughes Technical Center Fire Safety Branch, AJP6320 Bldg.
Federal Aviation Administration Status of Research & Testing to Replace Halon Extinguishing Agents in Civil Aviation Douglas Ingerson Louise Speitel Constantine.
ERT 312 SAFETY & LOSS PREVENTION IN BIOPROCESS HAZARDS IDENTIFICATION
FIRE EXTINGUISHER D TRAINING. Objectives Understand the combustion process and different fire classes. Understand the combustion process and different.
Fire Extinguisher Primer 10-4 training 10 Slides, 4 minutes.
RETROFIT OPPORTUNITY FOR HFC-125 IN AIRCRAFT ENGINE SYSTEMS Presented 19 November 1998 to: The International Aircraft Fire and Cabin Safety Research Conference.
Hot Work Permit Osan AB Fire Emergency Services.
Medium- and High-expansion Foam System Design
Federal Service for Environmental, Industrial and Nuclear Supervision LEGAL REQUIREMENTS ON EXPLOSION PROTECTED EQUIPMENT FOR THE GAS AND PETROLEUM ACTIVITIES.
Abacus is the leader in design and manufacture of Heat Transfer Equipments and Industrial Chilling Equipments. We have the services for Thermal Designing,
Carbon Dioxide System Design
Portable Fire Extinguishers MFRI Drill of the Month August 2016 Instructor Danny Braitsch.
ODS & SGG Considerations for Changing a System
Pre-Engineered Novec 1230 & FM-200 March 1, 2012
Component Availability Effects
“ Highlighting the risks and challenges presented by modern data-center cooling systems in fire detection and suppression applications. “ Dave Boyack Sales.
Reducing Risk with Competency and Compliance
Presentation transcript:

Kidde Fire Suppression Systems Engineered with 3M™ Novec 1230™ Fire Protection Fluid

3M™ Novec 1230™ Fire Protection Fluid Manufactured by 3M Introduced by 3M in 2003, at NFPA Fluorinated Ketone CF3CF2C(O)CF(CF3)2

3M™ Novec 1230™ Fire Protection Fluid Used in Total Flooding Applications Class A - (Ordinary combustible materials) Class B - (Flammable Liquids) Class C - (Energized electrical equipment) Design Concentrations range from 4.2% to 10%

3M™ Novec 1230™ Fire Protection Fluid People Safety NOAEL = 10.0% LOAEL = >10.0% EPA listed as approved for use in occupied spaces Class A use concentration = 4.2%

3M™ Novec 1230™ Fire Protection Fluid - Environmental Factors 0 Ozone Depletion Potential 5 day Atmospheric Lifetime Novec 1230 has distinct environmental benefits

3M™ Novec 1230™ Fire Protection Fluid - Major Application Markets Data Processing Centers Telecommunications Cell Sites, Switching Centers Industrial Oil and Gas Industry Environmentally sensitive markets/end users

3M™ Novec 1230™ Fire Protection Fluid Environmentally more friendly than other clean agents Minimal Storage Space Less Hardware over Inerts Lower Pressure during discharge than Inerts Pressure relief venting Puts out fire by cooling rather than Oxygen depletion

3M™ Novec 1230™ Fire Protection Fluid - Kidde Offering 25 Bar system Engineered System Offering Software Optimal Design Ambient Temp Range 0 C to 55 C

3M™ Novec 1230™ Fire Protection Fluid - Kidde Offering Cylinder Sizes to be offered 10-lb. to 900-lb. Offering All the necessary accessories for Installation Brackets, Nozzles, 10 Second Discharge Per NFPA 2001 UL, ULC and FM approved at Market Launch

3M™ Novec 1230™ Fire Protection Fluid - Kidde Offering Class A Design Concentration - 4.2% Class B Design Concentration - 5.6% Nozzles - Both 360 and 180 deg Options Minimum Nozzle Pressure - 91 psig (6 bar) Area Coverage - 10.9m x 10.9m (35.6 ft. x 35.6 ft) Area height coverage - 4.87 m (16 ft.)

3M™ Novec 1230™ Fire Protection Fluid - Kidde Offering Status - To Date Fire testing is complete Hardware testing is complete Software Development/Limit testing and Agency Witnessed Testing complete What's Left? Agency review of documentation

3M™ Novec 1230™ Fire Protection Fluid - Kidde Offering Targeted Market Launch - Q4 2004 3M Asia Marketing Launch October 6 Kidde technical certification school October 7