OIL BURNERS RIELLO 2000 SERIES.

Slides:



Advertisements
Similar presentations
Customer Service – International dept. STAR 24 3 E.
Advertisements

GAS BURNERS R 40 GS 20.
BUrners TRAining CEntre GAS BURNERS N 900 H/L N 900 H/L series.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
TYPES OF MECHANICAL SYSTEMS
Left Side Discharge Pressure Regulator
Heating Control Devices
BUrners TRAining CEntre LOW Nox BURNERS B G K series B G K series.
GI/EMME series TRAining CEntre Burner setting. TRAining CEntre Setting sequence: OIL PRESSURE SETTING : Pump and pressure regulator AIR QUANTITY SETTING.
Terms and Definitions Base Metal: Metal to be welded Fusion Welding: process that joins metals by heating them to a melting point and allowing them to.
BUrners TRAining CEntre GULLIVER BLU HYDRAULIC SCHEME.
Unit 12 Oil Heat Components
Engineer Presentation
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
1 Fuel Pumps. 2 Pumps 1.All oil burners for residential heating have pumps A. They are connected to a motor through a coupling 2.Description A. An oil.
Troubleshooting Electric Control Devices
BFP 21 L3 Oil Pump.
RES G series TRAining CEntre Burner Settings. General overview Burner is built with our standard components RIELLO’s pump RIELLO’s motor RIELLO’s Control.
RESIDENTIAL AIR HANDLERS
HYDRONIC HEATING AQUASTATS
Settings & Adjustments. Settings & Adjustments.
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
OIIL BURNERS R D B series Riello Burners - TRAining CEntre.
MODULATING BURNERS RL/M Series burner operation. UNMB1NL W1W2 B4 B3 AL CH AL1 Q NN N LANDIS LAL 1.25 or LOK 16. III M FR M.
Engineer Training UV Electrical Cabinet (1-15) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 1-15)
CONTROL BOX RMG
BURNER TRAINING CENTRE GI/EMME series. BURNER TRAINING CENTRE L1L2L M N ST3 30°ST2 0° ST1 130° MIN STAND-BY MAX OIL FM 123.
TECHNICAL TRAINING INVERTER-Y
BUrners TRAining CEntre RES G BLU HYDRAULIC SCHEME.
Oil Heat Oil Burner Parts.
BUrners TRAining CEntre GAS BURNERS GS series GS series.
BUrners TRAining CEntre CONTROL BOX RMO BUrners TRAining CEntre PRESS SERIES ONE STAGE TWO STAGE THREE STAGE Dedicated to: RL SERIES ONE STAGE TWO.
LIGHT OIL BURNERS R 40 series.
World Leaders in Combustion Management Solutions End User Guide Lockout Codes Pressure Sensors Error Codes Flame Safeguard UV.
RL BLU BUrners TRAining CEntre. RL BLU BUrners TRAining CEntre CONTROL BOX LOA B27 FEATURES: #Electrical protection IP 40 #Electrical.
BUrners TRAining CEntre GAS BURNERS N 120, 200, 400 N 120, 200, 400 series.
NEW BAXI BRANDED WALL HUNG GAS BOILERS Easiness and flexibility for the maximum comfort.
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
BUrners TRAining CEntre RS 45/M-160/M BLU INTERMITTENT OPERATION MODE.
Tractor Safety, Operation, and Maintenance
CGS Ground School Technical The Vigilant Electrical System © Crown Copyright 2012 No Part of this presentation may be reproduced without the permission.
MACHINE OPERATION.
Tractor Safety, Operation, and Maintenance
Unit 13 Oil-Burning Equipment
Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine.
Properties and combustion of fuel oils
 RES G RESIDENTIAL PROJECT
OIL BURNERS CONTROL BOX SERIES 599 SE Riello Burners - TRAining CEntre.
OFA200 Tim Stockwell.
GAS BURNERS R 40 GS 20 H/L.
CONTROL BOX RMG
CONTROL BOX RMO
CONTROL BOX RMO
T.S SEIUN MARU AUXILIARY BOILER Third Engineer 2019/2/19 ボイラ.
HYDRAULIC SCHEME PRESS G SERIES.
Universal Interrupted Electronic Oil Primary R7184U Training Module
LIGHT OIL BURNERS PRESS G series.
BS 2-3-4/M INTERMITTENT OPERATION MODE.
Presentation transcript:

OIL BURNERS RIELLO 2000 SERIES

MODELS : G30BR G35B G3RK G55 G55KR G103 G214D* 1.3  2.5 kg/h G35B 1.6  3 kg/h G3RK G55 2.3  4.65 kg/h G55KR 1.3  4.65 kg/h G103 3.5  8.7 kg/h G214D* 6/7.9  18 kg/h * Two stage by two pressure levels

WORKING FIELDS [mbar] [kg/h]

A B C D E F G OVERALL DIMENSIONS

HYDRAULIC CONNECTIONS

PUMP GROUP part N° 3008848

1 - Suction line 2 - Return line 3 - By-pass screw 4 - Gauge connection 5 - 2 nd stage pressure adjuster 6 - Suction gauge connection 7 - 1 st stage pressure adjuster 8 - Pressure reducer piston 9 - 2 nd stage valve 10 - 1 st stage valve 11 - Auxiliary pressure gauge Pump group part N° 3007343

It is important to equip the nozzle with a sintered filter SETTINGS & SUGGESTED NOZZLES Monarch R - NS Delavan W - A - E Steinen H - Q Danfoss H B G 30BR It is important to equip the nozzle with a sintered filter

SETTINGS & SUGGESTED NOZZLES Monarch R - NS Delavan W - A - E Steinen H - Q Danfoss H B G 35B

SETTINGS & SUGGESTED NOZZLES Monarch R - NS Delavan W - A - E Steinen H - Q Danfoss H B G 55

From GPH 0.85 Till GPH 0.75 SETTINGS & SUGGESTED NOZZLES Monarch R Delavan W - B Steinen Q Danfoss S Satronic S Fluidics SF G 55KR

SETTINGS & SUGGESTED NOZZLES Monarch R Delavan W - B Steinen S - Q Danfoss S - B G 103 For GPH 2.00 use, if possible, a full cone

SETTINGS & SUGGESTED NOZZLES Monarch R -PLP Delavan W - B Steinen S - SS Danfoss S Hago P G 214D

AIR DAMPER ADJUSTMENT(one stage): The air damper (A) opens due to the depression caused by the fan. In order to carry out the adjustment, operate on the screw (B) after loosing the nut (C). Once complete the adjust-ment, lock the nut. The settings refer to the burner with its cover fitted and combustion chamber with depression zero. These regulations are purely indicative. Each installation however, has its own unpredictable work-ing conditions: actual nozzle output; positive or negative pressure in the combustion-chamber, the need of excess air, etc. All these conditions may require a different air-damper setting. It is important to take account of the fact that the air out-put of the fan differs according to whether the burner has its cover fitted or not.

AIR DAMPER ADJUSTMENT (two stage): 2 nd STAGE ADJUSTMENT Adjustment of air shutter Unloosen the nut (6), turn the screw (7) until the air shutter (1) reaches the position desired. Then lock the nut (6). 1 st STAGE ADJUSTMENT Adjustment of air shutter Unloosen the nut (2), turn the screw (3) until the air shutter (1) reaches the position desired. Then lock the nut (2).

pre-heater thermostat WORKING MODE (one stage) control box 555SE electrical supply 230V +-10% 50Hz ignition transformer 8kV; 10mA safety thermostat) fuse 6 A F (fast) L boiler thermostat remote lock out signal (230V max 0.1A) L1 N N fotoresistence T1 T2 S3 B4 valve coil 30 =>3V DC 100 h pre-heater (230V); 55W) hour counter (230V max 0.1A) motor (90W) pre-heater thermostat (55°C)

WORKING MODE (one stage) control box 555SE h M

WORKING MODE (one stage) control box 555SE 0” h M

WORKING MODE (one stage) control box 555SE 0” h M

WORKING MODE (one stage) control box 555SE 0” h M

WORKING MODE (one stage) control box 555SE 0-120” pre-heating

WORKING MODE (one stage) control box 555SE h M

WORKING MODE (one stage) control box 555SE 12” -pre-purge h + 50VAC M

WORKING MODE (one stage) control box 555SE ignition (max 5”) h + M

WORKING MODE (one stage) control box 555SE ignition (max 5”) h + M

WORKING MODE (one stage) control box 555SE working h + M

WORKING MODE (one stage) control box 555SE lock out: no ignition h + M

WORKING MODE (one stage) control box 555SE lock out: no ignition h M

WORKING MODE (two stage) control box 554SE electrical supply 230V +-10% 50Hz ignition transformer 8kV; 10mA safety thermostat) fuse 6 A F (fast) L 1st stage thermostat remote lock out signal (230V max 0.1A) L1 N N fotoresistence T1 T2 S3 B4 h1 2nd stage thermostat hour counter 1st stage (230V max 0.1A) 1st stage valve coil 30 =>3V DC 100 motor (150W) 2nd stage valve coil 230 VAC (diodes provided) h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE 0” h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE 0” h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE 12” pre-purge h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE 12” pre-purge h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE 12” ignition h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE max 5” flame h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE working h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE 5” after: 2nd stage h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE 5” after: 2nd stage h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8

WORKING MODE (two stage) control box 554SE 1st stage h1 h2 B5 EL. DELAYING DEVICE T6 T7 M T8