Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.

Slides:



Advertisements
Similar presentations
User Guide KI 734x Series Two way Loss & ORL Tester
Advertisements

The EZ-SAT.
DP-IR Detecto-Pak Infrared
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Components: Sansa Clip Mp3, earbuds, USB cable, Quick Start Guide.
Acculab „Exceleron“ Acculab “Exceleron “ Series Multi-functional Industrial Scale Line Multi-function Industrial Scale.
PRESS C7000/C7000P/C6000 Color Density Control Color Balance
Microsoft Office XP Microsoft Excel
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
 Use the Left and Right arrow keys or the Page Up and Page Down keys to move between the pages. You can also click on the pages to move forward.  To.
LogTag Training January 2015
Training for Radiation Pagers Training for Radiation Pagers Berkeley Nucleonics Corporation 2955 Kerner Blvd. San Rafael, CA
University of Maryland Center for Environmental Science Chesapeake Biological Laboratory IP Phone Training.
M100 M100 Overview Preparation & Testing. M100 Overview  The M100 is a computerized tabulator that optically reads then counts and totals specially designed.
Project 2000 University Product Training
Memmert Oven (in yellow room) The door is opened by pulling the door knob, and is closed by pushing in the door knob. Control module /display Control module.
Unit Test Calibration Training
`SET-UP MANUAL SRM D248 PURPOSE:
CREATING A MULTIPLE PAGE REPORT Presented by: Dr. Ennis-Cole.
Familiarization and Operation
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
EDSM II Training. EDSM II EDSM II (Enhanced Digital Select Module) is a hand held program module used to program Atlas laundry dispensers –Recommended.
The UTE Speed-O-Calibration Unit (SOC) is used to calibrate the locomotive speedometer. This presentation is an operations outline for Ultra-Tech model.
DataLogger Operation - 1 DataLogger ® Operation Procedures.
Exceed Series Decorative Stitch Patterns The Exceed series also has a Decorative Pattern menu where intricate patterns can be selected. The Exceed Quilt.
AccuMax Multi-Point Injection Mechanics
Heart Rate The Heart Rate program allows the user to set a target heart rate. The system will alter it’s intensity (RPM’s) to maintain the targeted rate.
1 Training Manual: KI7400 & 7800 Series Sources Level 1, V2.0 August 2008.
Valor 1000 single-dual display models CP1-0 / September, 2009.
How To Activate Your New iPod Mini Print Ready Documentation.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
The New Adventurer Pro Is Here!. What’s New? Bright alphanumeric dual line display Better weighing cell and weighing performance 7 application modes Better.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
Working with GPS Stephen M. Kiama (MSc) [Geo-information Specialist]
H2 Zoom Recorder Operational Procedure. In the box All H2 Zoom kits contain –1 GB SD Card –Mic Clip Adaptor –Wind Screen –Earbuds –USB Cable –AC Adaptor.
NAVIGATOR™ Portable Balances
AutoMARK Overview Preparation & Testing. AutoMARK: An Overview Q: What is it? A: A great big printer Q: When is it used? A: Onestop and Election Day Q:
FROST I Site Initiation Visit version 1.4. IVTM System.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
GCS 300 System Operation Application – Level 1.
Introducing The IP550 IP Telephone. What to expect from your new IPitomy IP telephone system The IPitomy system has many of the same features of traditional.
Intuitive Programming System For The Mill
1. Enter service mode and scroll to the Calibrate menu option What is Rider Calibration? This feature enables a rider to calibrate the Watt sensor before.
ResponseCard XR User Data. Press the MENU button ResponseCard XR.
ResponseCard XR User Data Version 1.0 ®. Press the MENU button. ResponseCard XR.
Overview of MSWS Control of 212-LC July 15, 2006.
ACCU-CHEK Inform II Operator Training
WS50(Stratacache) Software updating guide (By Using USB)
JDS5 Training Guide. On Start Up you will see this screen click the OK button Click OK.
Manual Overview The Manual program is the most simplistic program the Intelli-Fit system offers. With just a touch of a few buttons, you are ready to.
InnoSys Park Brake Tool Master Control Panel Screens Revision A, 12Dec /12/20071.
Random The Random profile allows the user infinite number of profiles. No two profiles will be the same. The profiles look like similar to the hills profiles.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
Forge Echo Introduction. Base Package Getting to know the device G – Sensor Calibration F4 Key Assignment Application F4 Distance Application F4 Height.
IOPtiMate™ OT-135P2 Technical Training – Part I System Description, Installation & Operation IOP (07)
WELCOME. Skills and Techniques - Session 2 Skills and Techniques Booting from Windows 8.1 and Windows 10 devices.
PRO OX ® -100 Kit PROGRAMMABLE DIGITAL OXYGEN MONITOR US & FOREIGN PATENTS ISSUED & PENDING STATE-OF-THE-ART TECHNOLOGY FOR PRECISE OXYGEN MONITORING MADE.
AKIMBO [Dual Trigger Rapid Fire] With akimbo activated you will have rapid fire on both the left and right triggers (independently), this is great for.
CI-202 Leaf Area Meter Instrument Training Conducted by: Brienne Meyer
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
MONROI PCM TRAINING 26/09/2017.
MPU-16A / FPU-16 TEST UNIT TUTORIAL
Call to Fix Canon Pixma MX340 printer Error 5200
Intelli-Fit™ Systems Tutorial Constant Work
PHASE IDENTIFICATION UNIT (PIU)
Digital Chart Recorder Operation
2. ATP INITIALIZATION PLACE ATP SWITCH TO “1” OR “NORMAL” POSITION A
Presentation transcript:

Scout Pro Training

Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface Accessory w/cable Density/Specific Gravity Determination with Below Balance Hook Battery or AC Power (Power Pack Included) Integral Security Bracket Programmable Energy Saving Auto Shut-off The Ohaus Scout Pro

Unpack & Setup Shipping lock Secures load cell Battery Installation 4 AA batteries provide 40 hours of operation

Unpack & Setup AC plug Security bracket

Unpack & Setup USB Accessory RS232 Accessory

Unpack & Setup Rotate square pans counter clockwise Insert round pans

Operation Turn balance on Scout Pro is shipped ready to operate in all available weighing units, parts counting and percent weighing PRINT Unit 0.00g ON/ZERO Off Short press to print. Long press to switch weighing unit. 0.00g ON/ZERO Off PRINT Unit

Operation Hold Off until “OFF” is displayed, then release to turn off. ON/ZERO Off PRINT Unit OFF Weigh in any unit

Menus and Calibration With balance off, hold ON/ZERO until MENU is displayed MENU ON/ZERO Off PRINT Unit Release ON/ZERO to enter the menu C.A.L. ON/ZERO Off PRINT Unit C.A.L.S.E.t.U.P.U.n.I.t.E.n.d.

Menu System C.A.L. Calibration gkgozlbPC - Count - Cnt. Enh - Off %End PRINT Unit PRINT Unit PRINT Unit Auto-Off Linearity cal Mode - Display Hold - Totalize - Off End S.E.t.U.P. U.n.I.t. E.n.d. PRINT Unit

Calibration Access calibration C.A.L. ON/ZERO Off - C - C g Add cal weight ON/ZERO Off - C - d o n E

Parts Counting & Parts Counting Setup Mode: Parts Counting This mode allows the user to count based on the average weight of an original reference sample This mode is enabled by setting “PC” to “Count” in the “.U.n.i.t.” part of the menu To set-up mode: Enter Menu Mode, press PRINT/Unit to go to “.U.n.i.t.” and then press ON/ZERO/Off Press PRINT/Unit to go to “UnitS PC” and then press ON/ZERO/Off Press PRINT/Unit to go to “Count” and then press ON/ZERO/Off Press PRINT/Unit to go to “End” and then press ON/ZERO/Off Press PRINT/Unit to go to “.E.n.d.” and then press ON/ZERO/Off Sample Sizes -- The Scout Pro allows the user to change the sample size with a press of the Print/Unit key

Mode: Enhanced Parts Counting APW Enhancement -- The Scout Pro allows the user to turn-on automatic recalculation of the average piece weight (APW Optimization) -- this is the same function as found in Trooper Count and Ranger Count Without Optimization, the APW is the average of the weight of the sample, divided by the number of pieces in the sample -- if the user needs a sample of 100, they have to count by hand 100 pieces! With Optimization, the APW is the average of the weight of the initial sample as well as any subsequent samples -- the user can reach a sample of 100 by adding parts on the pan 10 at a time, increasing accuracy! Enhanced Parts Counting

Mode: Enhanced Parts Counting This mode is enabled by setting “PC” to “Cnt.Enh” in the “.U.n.i.t.” part of the menu To set-up mode: Enter Menu Mode, press PRINT/Unit to go to “.U.n.i.t.” and then press ON/ZERO/Off Press PRINT/Unit to go to “UnitS PC” and then press ON/ZERO/Off Press PRINT/Unit to go to “Cnt.Enh” and then press ON/ZERO/Off Press PRINT/Unit to go to “End” and then press ON/ZERO/Off Press PRINT/Unit to go to “.E.n.d.” and then press ON/ZERO/Off Sample Sizes -- The Scout Pro allows the user to change the sample size with a press of the Print/Unit key Enhanced Parts Counting Setup

Parts Counting Operation CLr.APu ON/ZERO Off Put 5 PC PRINT Unit PRINT Unit 5 PC Place a container Press and hold PRINT/Unit key until “PC” is indicated Display will then show “Clr.APu” Press Print/Units to use the average piece (APW) stored in memory (if there is one) To re-establish a new APW, press On/Zero/Off once Scout Pro will display “Put 10”. To select a different sample size, press Print/Unit Place displayed number of pieces in container and press ON/ZERO/Off Scout Pro will calculate APW and display total count To reset APW, press Print/Unit until “PC” is displayed again g ON/ZERO Off

Mode: Percent Weighing This mode allows the user to display the weight of a sample as a percentage of a reference weight The reference weight is placed on the pan first, and equals 100% Each reference weight will be a percentage from 0.1% to 99,999.9%, depending on the Capacity X Readability of the scale -- most users will use 1.0% to 200.0% at the most Applications: Formulation and compounding, weight checking Percent Weighing %

Percent Weighing % Setup Mode: Percent Weighing This mode is enabled by setting “%” to “On” in the “.U.n.i.t.” part of the menu To set-up mode: Enter Menu Mode, press PRINT/Unit to go to “.U.n.i.t.” and then press ON/ZERO/Off Press PRINT/Unit to go to “UnitS %” and then press ON/ZERO/Off Press PRINT/Unit to go to “On %” and then press ON/ZERO/Off Press PRINT/Unit to go to “End” and then press ON/ZERO/Off Press PRINT/Unit to go to “.E.n.d.” and then press ON/ZERO/Off

Percent Operation Press and hold Print/Unit key until “%” is indicated Display will then show “Clr.Ref” Press Print/Units to use target weight in memory (if there is one) To enter a new target weight, press On/Zero/Off once Scout Pro will display “Put.rEF” Place target weight on pan, press On/Zero/Off again -- Scout Pro will display target weight value Press On/Zero/Off again -- Scout Pro will display 100% To reset target weight, press Print/Unit until “%” is displayed again CLr.rEF ON/ZERO Off PutrEF % % PRINT Unit PRINT Unit ON/ZERO Off g ON/ZERO Off % 2 5 %

Mode: Display Hold This mode allows the user to hold the highest stable weight on the display until manually cleared Display Hold can work with any weighing unit or mode -- including % or parts counting -- except Totalization The Scout Pro will show the current measurement on the pan with a flashing stability indicator “*” Applications: Postal and shipping 0.00  Display Hold

Mode: Display Hold This mode is enabled by selecting “HoLd” in the “MOde” part of the “S.E.t.U.P” menu To set-up mode: Enter Menu Mode, press PRINT/Unit to go to “ S.E.t.U.P ” and then press ON/ZERO/Off Press PRINT/Unit to go to “MOdE” and then press ON/ZERO/Off Press PRINT/Unit to go to “HoLd” and then press ON/ZERO/Off Press PRINT/Unit to go to “End” and then press ON/ZERO/Off Press PRINT/Unit to go to “.E.n.d.” and then press ON/ZERO/Off 0.00  Display Hold Display Hold Setup

Display Hold Operation Hold PRINT Unit  g ON/ZERO Off HLd.OFF To Use Mode: Press PRINT/Unit once to start Display Hold “HoLd” will be displayed briefly indicating Display Hold is active Place weight on pan “ * ” will flash indicating highest stable weight value will be held Take weight of pan The display will change and then display the Hold value with the flashing “ * ” To Clear Display press On/Zero/Off To Exit Mode hold ON/ZERO/Off until “HLdOFF” is displayed  g 0.00  Display Hold

Mode: Totalization This mode allows the user to sum a series of weights -- up to the limit of the display (999,999) Totalization can work with any weighing unit or mode -- including % or parts counting -- except Display Hold Once you are in Totalization, you cannot change weighing units/modes without exiting Totalization The Scout Pro will show the current measurement on the pan with a solid “t”, and then the total as a flashing “t” Applications: Formulation and compounding, parts kitting Σ Totalization

Mode: Totalization This mode is enabled by selecting “totAL” in the “MOde” part of the “S.E.t.U.P” menu To set-up mode: Enter Menu Mode, press PRINT/Unit to go to “ S.E.t.U.P ” and then press ON/ZERO/Off Press PRINT/Unit to go to “MOdE” and then press ON/ZERO/Off Press PRINT/Unit to go to “totAL” and then press ON/ZERO/Off Press PRINT/Unit to go to “End” and then press ON/ZERO/Off Press PRINT/Unit to go to “.E.n.d.” and then press ON/ZERO/Off Σ Totalization Totalization Setup

Totalization Operation Press PRINT/Unit once to start Totalization “totAL” will be displayed briefly and “t” will be displayed indicating Totalization is active Place a sample on the pan and press PRINT/Unit to enter the weight into memory “t” will flash indicating total weight. Remove the sample. “t” will stop flashing and the balance will return to zero Repeat the procedure with another sample and read the totalized weight To exit Totalization, hold down ON/ZERO until “tot.OFF” is displayed t o t A L PRINT Unit 0.00 g t ON/ZERO Off tot.OFF g t PRINT Unit PREPARATION: 2 plastic cups, different colored water samples. Tare an empty cup Σ Totalization 0.00 g t

The Ohaus Scout Pro Scout Pro USP’s Mechanical overload and shock load protection Protects weighing cell 4 times better than Scout II Simple 2-button operation – 5 applications and 7 weighing units Optional USB or RS232 interfaces, simply insert the module; cable included