Www.alfalaval.com. © Alfa Laval Pure Cooler R134a r-evolution New high efficiency R134a dedicate evaporator. Pure Cooler Passes (tube side)1 Tube arrangementStraight.

Slides:



Advertisements
Similar presentations
13 mm (1/2) PRO-FLO X ORIGINAL METAL UL 79 LISTED PUMP.
Advertisements

COOLING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Engine & Transport Integrated Cooling Systems. © Alfa LavalSlide 2 Alfa Laval Integrated Cooling Systems, ALICS Integrated marine cooling.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Trane Variable Water Flow System
How Refrigerators and Freezers Work
Moisture to water converter. Out Line : Abstract Introduction Heat Pump Heat Pump Components Conclusion.
HVAC System Design PES Institute of Technology. Objective Goal: To develop an automotive air-conditioning system that is smaller and lighter than with.
Components of HVAC System
Gas ammonia out to turbine poor mixture water/ ammonia rich mixture water/ ammonia Gas Assisted Solar Absorption Heat Engine GASAHE heat Diffusion absorption.
STEAM CONDENSERS.
Aqualean Product Presentation 1 By Laurent Domenget Product Manager, Rooftop & Packaged Air Units.
ISAT Module III: Building Energy Efficiency
Thermo-economic Optimization of STHE P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Minimizing capital and operating costs of shell.
RLC-CMS002-E4© American Standard Companies, inc All Rights Reserved Concentration of intelligence, High reliability. Series R TM.
…an innovative shell and tube heat exchanger with an exceptionally high heat transfer coefficient for industrial fluid cooling and air conditioning.
Supervised by : Dr. mohammad fahim Eng. Yousef ali Yaqoub bader ali.
CMS FPIX Cooling Prototype Phase One Estimate and Conceptual Design R. L. Schmitt 10/28/2009.
Refrigeration Terms Cooling Load, Cooling Capacity – Q in Compressor Load – W in Condenser Load – Q out Tons of Refrigeration – Rate of Heat Input Refrigerant.
Alfa Laval Group Presentation Alfa Laval is a leading global provider of specialized products and engineered solutions. The company.
Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling.
Air Conditioning in tropical climates Presented by Ranjeet Kumar Nayak.
Air Conditioning Circuit
ME 414 : Project 1 Heating System for NASA North Pole Project Team Members Alan Benedict Jeffrey Jones Laura O’Hair Aaron Randall May 5, 2006.
Alan Hinton March, 2006 Slide 1 NEW! ‘YEFB’ HIGH PRESSURE BLOWER UNITS.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
The Refrigeration Process
1 AxiCool Unit Cooler / Evaporator - „Plug & Play“ Fan series GLV955 - GTB/MM-November 2013.
Rod Dry Dec Training Module #6: Problem Statement Low pressure steam (1 barg) is condensed in a heat exchanger with cooling water. The exchanger.
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
Heat Exchangers Heat exchangers are used to transfer heat from one stream to another. They are used to heat streams and to cool streams. The streams can.
BCWC Water-cooled water chillers with centrifugal compressor/s
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
Equipment Design Designed by Eman A. Khajah. Outline Design of Heater. Design of Stripper.
President UniversityErwin SitompulThermal Physics 10/1 Lecture 10 Thermal Physics Dr.-Ing. Erwin Sitompul President University
Heat Transfer Equations For “thin walled” tubes, A i = A o.
BasicRefrigerationSystem 4 Component Flow Diagram.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
Evolution Daikin Chiller Range
Status of the Marco chiller and Marco capacity analyses Bart Verlaat, Lukas Zwalinski, Maciej Osterga, Jan Godlewski MPI Munich,1 March.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 11: STEAM PIPING SYSTEM (1)
B26 The AsyMatrix Condenser for Heat Pumps Powerful, just smaller.
FRENCH DOOR SIDE BY SIDE
2016 Chiller New Products Presentation.
1 Summer Training On Refrigeration and Air Conditioning From:-Amber Enterprises PVT.LTD.
Ullrich, DESY Dubna GDE XFEL The European X-Ray Laser Project X-Ray Free-Electron Laser 1 Water cooling XFEL Desingn of the XFEL water cooling.
ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI APPENDIX.
CHEMCAD Seminar Heat Transfer John Edwards, P&I Design Ltd
. Level 3 Air Conditioning Inspections for Buildings
Compact line ‘EW*D~J-’ water-cooled chiller range
Thermag VII, Turin, Italy
Book E3 Section 1.4 Air-conditioning
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Reheat Coil (Typical of 5)
UNIT IV AUXILIARY SYSTEM
How Refrigerators Work
51 mm (2") Center-Ported Plastic Pump
Date of download: 12/25/2017 Copyright © ASME. All rights reserved.
Process Equipment Design and Heuristics – Heat Exchangers
Refrigeration/AC/Heat Pumps
Refrigeration/AC/Heat Pumps
Steam / condensate system Heat recovery – cleaning circuit
Cooling and Ventilation
Objectives Control: Cooling towers Multizone vs. Single system
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Air-conditioner -IDU Air-conditioner 2D Simplified model for Analysis.
Reheat Coil (Typical of 5)
Objectives Finalize AHU processes
How Refrigerators and Freezers Work
Door Heat Exchanger: Specification
Presentation transcript:

© Alfa Laval Pure Cooler R134a r-evolution New high efficiency R134a dedicate evaporator. Pure Cooler Passes (tube side)1 Tube arrangementStraight Tube OD5/16” (7.94 mm) TubeFinned inside, high efficiency design exclusive for AL

© Alfa Laval Pure Cooler The new series will be added to the existing “U tube” 2-pass series (Dryplus-E) Dryplus-EPure Cooler Passes (tube side)21 Tube arrangementBent (“U tubes”)Straight Tube OD3/8” (9.52 mm)5/16” (7.94 mm) Tube bundleExtractableNon extractable R134a r-evolution

Pure Cooler The capacity range The new evaporator design is featuring from 1 to 4 independent refrigerant circuit! Minimum cooling capacity (kW) Maximum cooling capacity (kW) 1 refrigerant circuit refrigerant circuits refrigerant circuits refrigerant circuits The cooling capacity range of the new evaporator series is particularly wide, from 100 to 2200 kW (30 to 625 Rtons) at nominal conditions : water 12/7°C; SST=3°C; Tliq=42°C.

© Alfa Laval Pure Cooler Five versions Standard Version Low Temp. Version (BT) High Pressure Version (HP) High Pressure Version (HPR) High Pressure Version (HPW) Tube side PS (bar) Shell side PS (bar) Minimum/maximum TS (°C) -10/+50-40/+50-10/+90 Five different versions for standard air- conditioning/process cooling duties, low temperature and heat pump applications. Values referred to PED approval. ASME approval available.

© Alfa Laval Pure Cooler General features Flange-type refrigerant connections Flexible joint (Victaulic) water connections (flange- type available) Available versions: left and right-handed and top connections Plastic material baffles Optimized water flow Refrigerant distributor(s) (patent pending High efficiency finned tube

© Alfa Laval Pure Cooler VS DE series We have a averadge reducing of RCPL price of 30% Talking on work condition 12/7°C water side SST=3°C; Tliq=42°C; superheating 5k. Here some exaple: CapacityDEDPCDRCPL DERCPL PCDifference %Difference € 722DED745PCD % DED645PCD % DED860PCD % DED645PCD % DED715PCD % DED860PCD % DED955PCD % DED1100PCD % DED1100PCD %-18556