Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Controllability of DG helps managing Distribution Grids J. A. Peças Lopes

Slides:



Advertisements
Similar presentations
RES-E Impact on Transmission Grid and Power System Reserves
Advertisements

Planning, optimization and regulatory issues
Development and Operation of Active Distribution Networks: Results of CIGRE C6.11 Working Group (Paper 0311) Dr Samuel Jupe (Parsons Brinckerhoff) UK Member.
Wind Turbine Session 4.
NETWORK ANALYSIS IN GIS ENVIRONMENT Uday Deshmukh North Delhi Power Limited.
Reliability Software1 Reliability Software Minimum requirements & Best practices Frank Macedo - FERC Technical Conference July 14, 2004.
ERCOT VRT Study, Phase I ERCOT ROS Meeting December 10, 2009.
Smart Grid Applications: Viewpoint of an Electrical Power Engineer Francisco de Leon October 2010.
Distribution System Analysis for Smart Grid Roger C. Dugan Sr. Technical Executive, EPRI Webcast Feb 8, 2011.
Challenge of Large Scale Wind Power Integration - Introduction to the Workshop Pradeep Perera Principal Energy Specialist Asian Development Bank.
Wind farms with HVDC delivery in Load Frequency Control Lingling Fan April 22, 2010.
Presented by: Hao Liang
1 Distributed Generation and Power Quality. 2 Distributed Generation Distributed generation (DG) or distributed generation resources (DR) –Backup generation.
Campus da FEUP Rua Dr. Roberto Frias, Porto Portugal T F © 2009 Decentralised Energy Systems.
Power Systems Consulting and Software 4 March 2004 BWEA Conference: UK Offshore Wind 2004 Integration of Offshore Wind Farms into the Local Distribution.
Integration of Large-Scale RES in Island Power Systems Prof. Nikos Hatziargyriou, National Technical University of Athens
Supervisory Systems.
Stability analysis on WECC Systems with Wind Penetration and Composite Load Model Hyungdon Joo and Melissa Yuan Mentor Yidan Lu Professor Kevin Tomsovic.
Costs of Ancillary Services & Congestion Management Fedor Opadchiy Deputy Chairman of the Board.
Luis Layo (SP) Session 4 – Block 3 – Selected Paper - Question 6 Barcelona May Analysis of the effects of wind farms dynamic behaviour on.
21 st May 2015 SMARTGREENS 2015 Lisbon, Portugal Lane Department of Computer Science and Electrical Engineering West Virginia University Analyzing Multi-Microgrid.
Applying the Distribution System in Grid Restoration/NERC CIP-014 Risk Assessment Srijib Mukherjee, Ph.D., P.E. UC Synergetic.
Frankfurt (Germany), 6-9 June 2011 Power System Impacts from Large Scale Deployment of EV -The MERGE project – João A. Peças Lopes
1 Impact of Distributed Generation on Voltage Profile in Deregulated Distribution Systems By: Walid El-Khattam University of Waterloo, Canada
University of Illinois Urbana-Champaign
Voltage Collapse M. H. Sadeghi Winter 2007 KNTU. Power System Stability IEEE: Power system stability is defined as the capability of a system to maintain.
Thomas DEGNER -DE- BETA SESSION 4b: Integration of RES+DG Barcelona May DISPOWER Distributed Generation with High Penetration of Renewable.
AFREPREN/FWD Cogen Centre Training Workshop on Cogeneration in Africa
Farid Katiraei Ph.D. Candidate
Frankfurt (Germany), 6-9 June 2011 GONZALEZ–CH–RIFS4–0182 OPERATIONAL STABILITY OF SHUNT CIRCUIT-BREAKER SYSTEMS IN UNGROUNDED MV NETWORKS WITH DISTRIBUTED.
Black Sea Regional Transmission Planning Project By Predrag Mikša EKC - Electricity Coordinating Center Istanbul, March 2011.
Agustoni IT Session 2 – Block 3 Barcelona May 2003 Proposal for a High Quality dc Network with Distributed Generation A. Agustoni, M. Brenna, E.
Electricity Research Centre, University College Dublin Wind turbine modelling for grid code analysis Alan Mullane & Mark O’Malley Electricity Research.
Frankfurt (Germany), 6-9 June 2011 MARTENSEN – DE – Session 4 – 1221 The Cell Controller Pilot Project (CCPP): From Surviving System Black-Out to Market.
Voltage grid support of DFIG wind turbines during grid faults
Overview What's is micro grid Over view of electric grid
Nikos HATZIARGYRIOU – Greece – BETA SESSION 4b: Integration of RES+DG Barcelona May 2003 BETA SESSION 4b: Integration of Renewable Energy Sources.
CLEMSON UNIVERSITY DG CONFERENCE UPDATE ON THE CURRENT STATUS OF DG INTERCONNECTION PROTECTION WHAT IEEE 1547 DOESN’T TELL YOU ABOUT INTERCONNECTION PROTECTION.
Energy Storage Applications at AEP Emeka Okafor American Electric Power Presentation to SouthWest Electric Distribution Exchange May 7, 2009.
Manjula Dewadasa Arindam Ghosh Gerard Ledwich
1 Distribution Networks For Large Cities: EPRI Research on Modelling and Analysis Roger DUGAN Sr. Technical Executive Electric Power Research Inst. US.
Clemson University Electric Power Research Association CHANDANA BOMMAREDDY CLEMSON UNIVERSITY DG VOLTAGE CONTROL IN AN ISLANDING MODE OF OPERATION.
Daudi Mushamalirwa Luanda June, 2014 Technical issues of the stability of small size electric systems composed of wind generators and conventional generating.
Situational Awareness UPDEA - Workshop. Awareness of the Situation 25,623 Alarms in 8 Hours 53 Alarms / min (average) 80% Are consequential Things to.
DISTRIBUTED GENERATION, RENEWABLE ENERGY AND SUSTAINABILITY. IMPACT ON POWER QUALITY AND NETWORK PLANNING “Inauguration of the 6th Framework Programme”
Queensland University of Technology CRICOS No J Protection of distributed generation connected networks with coordination of overcurrent relays.
Dale Osborn Midwest ISO October 13, 2008 EE 590 Transmission Planning with Significant Energy Resources.
Nelson Kagan BR Session 4 – Block 3 – Planning – Paper #66 Barcelona May Technical Assessment for the Installation of Dispersed Generation.
Power Plant Construction and QA/QC Section 4.3 – Electrical Interconnections Engineering Technology Division.
Steady State Analysis Of A Microgrid Connected To A Power System
Optimal Power Flow- Basic Requirements For Real Life.
Delivering for 2020 TSO Facilitation of Renewables Studies EirGrid Customer Conference Jonathan O’Sullivan October 2009.
Optimal Power Flow- Basic Requirements For Real Life Their Problems And Solutions.
Transmission Voltage Management Ross Owen Oncor Electric Delivery.
Oncor Transmission Service Provider Kenneth A. Donohoo Director – System Planning, Distribution and Transmission Oncor Electric Delivery Co LLC
MULTI-MICROGRIDS AS A SMART STRUCTURE Carlos Moreira Ciência 2010 –
(c) IRD 2002 Power System Restoration (Black Start) Black Start Panel Session IEEE PES Summer Meeting Chicago, Illinois July 23, 2002 M. M. Adibi IRD Corp.,
Distribution System Analysis for Smart Grid
Agenda TSOG 8th November
IG BASED WINDFARMS USING STATCOM
Control Schemes for Distribution Grids with Mass Distributed Generation AUTHOR: UMAIR SHAHZAD.
Subteam 1a Competitive Solicitations Framework Working Group Meeting
Planning Tools Overview
POWER SYSTEM ANALYSIS INTRODUCTION.
EU-IPA12/CS02 Development of the Renewable Energy Sector
University of Ljubljana, Faculty of Electrical Engineering - Slovenia
Sami Repo Tampere University of Technology FINLAND
Review of Distribution Network Protection
Planning Tools Overview
Jakov Chavez Vega Kalle Valtavirta
Presentation transcript:

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Controllability of DG helps managing Distribution Grids J. A. Peças Lopes

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Exploiting DG to improve system operation DG has been considered as non controllable and non dispatchable, since all the energy production has priority to be absorbed by the network; The increase in DG foreseen for the next years will require a different approach regarding the way how DG units will be operated: –Concepts of controllability should be developed and exploited: Participation in reactive power control; Interruptability; Delivery of ancillary services (primary and secondary reserves, according to the conversion technology and primary energy sources); Participation in system restoration strategies; –Development of concepts related with control of clusters of DG and virtual power stations;

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Main characteristics of DG units and controlability concepts Three main types of energy conversion systems can be found among DG units: –Conventional synchronous machines (cogeneration, CHP, mini-hydro); –Asynchronous generators (wind power, mini-hydro); –AC/DC/AC electronic conversion systems used together with synchronous or induction machines (micro-turbines, fuel cells, wind generators). Classification (according to primary energy source and conversion system used): –Non- controllable (Ex: Wind park with asynchronous stall generators); –Partially controllable (Ex: Wind park with synchronous variable speed gen. and AC/DC/AC converters); –Controllable (Ex: Mini-hydro or Cogeneration plant with synchronous units).

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation DG units used to optimise the distribution system operation DG can be used to optimise the operation strategy of distribution networks. The Problem can be formulated an optimisation problem: Min (active power losses) Subj. to: Vmax < V i < Vmin S ij max < S ij Qgmax i < Qg i < Qgmin i taking into account the type of generator Qimpor max < Qimpor Transformer tap limits are kept Control variables: Qg, capacitor banks and transformer taps The need to use a motor of optimisation (Evolutionary Particle Swarm Optimisation – EPSO)

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Some results of the participation of DG in Voltage VAR control Test System: 60 kV distribution network with a large penetration of DG (mini-hydro and wind generation). Activate control on reactive power generated in the DG Units. Activate control on reactive power generated in the DG Units.

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Some results of the participation of DG in Voltage VAR control Changes in active Losses –Peak load scenario –A clear reduction on actives losses was obtained

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Some results of the participation of DG in Voltage VAR control Results concerning voltage in network busses

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Dynamic Impacts Dynamic behaviour impacts need to be addressed using adequate DG modelling and DG equivalent representation: –Considering disturbances resulting from DG operation; –Considering disturbances in distribution networks; –Considering disturbances in the transmission system

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Dynamic behavior analysis Scenario: Week peak with maximum dispersed generation Disturbance: Outage of Power Plant H: 7,346MVA, production of 6,692+j3,03 MVA, injection of 2,678+j1,081 MVA (tg  = 0,404) Voltage profile: 60kV bus at the substation

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Dynamic behavior analysis 15 kV bus of the feeder where the power plant was connected 15 kV bus of the feeder where the power plant was not connected

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Dynamic behavior analysis (Impact in the other generators)

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Relay coordination Under voltage relay coordination is needed; Energy conversion systems need to able to withstand low voltages during short-circuits up-stream. Frequency changesChanges in contractual inter-area power flows

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Impacts on Operation Load flows become bi-directional; Voltage profiles have different patterns; Losses change as a function of the production and load levels; Congestion in system branches is a function of the production and load levels; Short-circuit levels increase; Power quality may be affected; Voltage transients will appear as a result of connection disconnection of generators; Risk of islanding operation; Reliability may be reduced; System dynamic behavior may be largely affected; Protections coordination is needed;

Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Conclusions The future: –DG units should be more actively used to help in the management of the distribution grid; –New DMS tools need to be developed: Topology processor with capabilities of identification of energised areas; Voltage and reactive power control; Load and current forecasting; Load flow including new generator models and load allocation algorithms to allow load flow to run; Optimum network reconfiguration; State estimation (considering that some DG units will not be monitored and new pseudo-measures need to be defined); –Cluster control strategies should be implemented, involving the development of local dispatch centres; –Development of DMS training simulators for distribution grids with large amounts of DG (steady state and dynamic behaviour).