The DUCTZ Experience. A Brief Overview of how DUCTZ Cleans a Heating and Cooling System.

Slides:



Advertisements
Similar presentations
The cleaning procedures for Operating Suites are broken into 2 groups.
Advertisements

Heating, Ventilation, and Air-Conditioning (HVAC) Systems
October Module 5: Cleaning Activities and Checking Your Work Overview Interior cleaning techniques. Exterior cleaning techniques. How to check.
General Safety Overview and Information
BSA Health System, May 2009 Next Slide Previous Slide BSA HEALTH SYSTEM Infection Control during Construction, Renovation, Repairs, and Maintenance All.
Heating, Ventilating, and Air-Conditioning
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
Chapter 13, Section 4. Safety First: Preparing Trash for Recycling Wear heavy, latex utility gloves. Do not reach into the trash to pull out an object.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
Cutting and Threading Steel Pipe
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
ATLIER FRANCOIS (COMPRESSOR). MAINTENANCE AND CHECKS DAILY CHECKS DAILY CHECKS INSPECT AND NOTE THE OIL LEVEL AND ALL THE PRESSURE AND TEMPERATURE LEVELS(FILLL.
The DUCTZ (of the Upper Bay Region) Experience
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
BASICS OF HVAC Ivy Tech Community College. Definitions – Page 862 HVAC systems are made up of the mechanical equipment such as the furnace, air conditioner,
SETUP Chapter 6 Lead Abatement for Workers Course.
WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM Overview Introduction to the Weatherization Assistance Program Communication Skills House as.
A Bad Atmosphere Can be deadly Requires a respirator.
If you use your computer more than a few hours per day, we suggest you not to turn off your computer at the end of the day. Instead turn off only the.
ThermexWELD Exothermic Welding Training Guide
Overview The top seal mechanism consists of a foil unwinding and feeding mechanism and a cutting and welding mechanism. It is designed to cut out and weld.
Basic Cleaning Procedures Sr. Muthulakshmi - Housekeeper.
Sanding Waste Management. Sanding Waste Environmental & Health Concerns Hazardous waste Hazardous waste May contain heavy metals May contain heavy metals.
Chapter 4: Air Leakage Control: Materials and Techniques
STEAM HEATING.
AIR CONDITIONING (COOLING)
Accessories Planned Maintenance. Types l Humidifiers l Air Cleaners l Heat Recovery Ventilators l Condensate Pumps.
DST H.O.M.E. Home Ownership Maintenance and Education Property Maintenance: Protect Your Property Value.
4/11/09Sustainable Bulding Advisor1 Vince Cord Poly-Tech Environmental Inc.
Winter Camp Awareness Tents and Terrain The Objective: To Provide you with information in selecting the proper tent for snow camping and how to construct.
Tempest Blower SECTION: Tools and Equipment ISSUED: REVISED: ##-####
October Module 6: Cleaning Activities and Checking Your Work Overview What is effective cleanup? Interior cleaning techniques. Exterior cleaning.
TRENTON Casing Filler Presentation
Trade Skills Duct Sealing. 2 In houses with forced-air heating and cooling systems, ducts are used to distribute conditioned air throughout the.
9/30/ Module 4 Clean-up and Check Your Work.
CLM Maintenance. Covers : 1 - Side cover, 2 - Back cover, 3 Top cover, 4 - Lamp door, 5 - Side cover input and communication side, 6 - HEPA dust filter,
Clearance Testing and Procedures. Remediation Goals Eliminate contamination Eliminate source Thorough cleanup.
Engine Performance BASIC MAINTENANCE AND LIGHT REPAIR.
Inspections. Structural Evaluation Look for any movement, check alignment, bowing, cracks, separation Basement wall/foundation Check floors & ceiling.
HEALTHCARE SYSTEM Infection Control during Construction, Renovation, Repairs, and Maintenance All workers engaged in the construction, renovation, repair,
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
Creating a Clean and Hygienic Foodservice Operation
Clean the coils underneath the refrigerator to ensure that the compressor fan can pass fresh air. Unplug the machine, pull out the vent plate that covers.
1 Second Layer of Poly At this point all poly EXCEPT critical barriers can be removed. Some specs require leaving the last layer of poly up until final.
Technician’s Guide & Workbook for Duct Diagnostics and Repair.
How to maintain your home’s air conditioner
Parts Cleaning Equipment
BASIC GAS METAL ARC WELDING
洗手及 负压技术 余 波
GENERAL SAFETY PROCEEDURES & PRACTICES
Heating Ventilating and Air Conditioning
How To Replace YOUR Car Battery
Furnace Cleaning and Some Tips for Repairs
Tips to Remember When Dealing with Furnace Cleaning
Click anywhere to get started…
GLOVE BAGGING & PLASTICIZING
EPA Lead Certification Requirements
Stanley Steemer Air Duct Cleaning
TRENTON Casing Filler Presentation
The Improvement of ALARA for the Steam Generator Maintenance
Compressed Air Safety.
Disaster Site Worker Safety
Disaster Site Worker Safety
The DUCTZ Experience 1.
The DUCTZ Experience 1.
Atlantic Duct Cleaning
Machine Shop safety.
Presentation transcript:

The DUCTZ Experience

A Brief Overview of how DUCTZ Cleans a Heating and Cooling System

System Inspection Always begin with an inspectionCheck all trunk lines and branch lines Inspect the inside of the unit, the blower and the coil as well

5. Clean Blower and Coil 1. Create Access 2. Clean registers 3. Use Negative Air Pressure 4. Clean Every Inch of Ductwork 6. Seal Access Holes

Location Preparation Technicians bring a door mat, and will use shoe covers, and drop cloths to protect your flooring. Corner Guards are put into place to protect walls and stairways Any valuable to breakable items are relocated from the work areas

Access holes are cut into the supply and return sides of the system so that the HEPA filtered negative air collection unit may be connected. These access holes are 8” to 12” in diameter. Smaller access holes are cut into strategic parts of the ductwork so that mechanical brushes and air tools may be inserted into the ductwork. These access holes are 1” to 2.5” in diameter. Creating Access Holes

Clean Registers and Diffusers Registers and diffusers should be removed (if possible) HEPA vacuum loose debris off registers and diffusers Heavy debris should be washed off registers outside of the home

During cleaning, the entire HVAC system is placed under continuous negative pressure (vacuum) to prevent the spread of contaminants. Continuous negative pressure allows very fine particles to be removed from the system as they become airborne, ensuring that these particles are not released into the living space when the system is turned on after cleaning. This negative pressure also serves to extract the loosened contaminants, which are collected and removed from the home. Collection of Contaminants

Properly cleaning HVAC systems requires removing the sources of contamination. Source removal begins with use of one or more agitation devices designed to loosen contaminants from the surfaces within the heating and air-conditioning system. Examples of agitation devices include brushes, air whips, and compressed air nozzles or “skipper balls.” Agitation can also be achieved through hand-brushing or contact vacuuming. Breaking Loose the Contaminants

Mechanical Brushing System Most aggressive method to agitate dirt and debris Driven by power drillsPrimarily used on metal ductwork

Air Wash System and Tools After mechanical brushing is complete, the Viper Rod system uses compressed air to mechanically agitate all surfaces of the ductwork, dislodging remaining debris.

Clean the Air Handler, Blower Remove the panel and use a HEPA filtered vacuum to remove debris from inside the unit. If debris on the blower is light and loose, use HEPA filtered vacuum to remove it. Remove blower, if necessary, and clean outside of the home using a power washer.

Clean the Coil Use a HEPA filtered vacuum to contact vacuum debris off of the coil If debris is light and loose, use HEPA filtered vacuum to remove debris If necessary, use wet cleaning methods to remove debris from coil

If you do not clean the inside of the unit, the blower and the coil, it doesn’t matter how clean you make the ductwork. Full system cleanliness is not achieved until all components of the system are cleaned. Important to Know

Seal Access Points Large holes are sealed with sheet metal patches, zip screws and foil tape Small holes are patched with caps that are specifically made for these accesses All access holes are sealed air tight to ensure system efficiency

Thank You! Contact DUCTZ of the Upper Bay Region for a free in home assessment and estimate Thank You! Contact DUCTZ of the Upper Bay Region for a free in home assessment and estimate