Presentation to the IEEE Power and Energy Society, Phoenix Chapter Radisson Hotel Phoenix Airport Phoenix, Arizona, March 22, 2012 Carl L. Benner, PE Sr.

Slides:



Advertisements
Similar presentations
Westar Energy Smart Grid
Advertisements

Smart Motor Management
Zhongxing Telecom Pakistan (Pvt.) Ltd
Utility Needs and Smart Grid for Major Storm Events July 11, 2013 Edward Gray, PE Director – Transmission and Distribution Engineering.
Page 1 Outage Management Roy Hoffman 29 Jan 2001.
Site Safety Plans PFN ME 35B.
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Configuration management
Chapter 1 Introduction to the Programmable Logic Controllers.
Copyright © 2007 Ramez Elmasri and Shamkant B. Navathe Slide
Beckett Energy Systems
Customer Service.
1 Storm Center ® Online Outage Map Tim Prince, Emergency Operations Bob Williamson, GIS Support
Outage Reporting Hierarchy Background Data Capture Structure Next Steps.
Executional Architecture
1. Four LLs were published in February Transmission Relaying – Undesired Blocking 2.Lack of Separation for Critical Control Power Supply Leads.
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
1 Smart Grid Vision Electric Grid Modernization Steering Committee Grid Facing Technology Subcommittee January 14, 2013.
© Paradigm Publishing Inc Chapter 10 Information Systems.
Chapter 10 Delivering the System Shari L. Pfleeger Joann M. Atlee 4 th Edition.
Internal Control and Control Risk
DISPUTES & INVESTIGATIONS ECONOMICS FINANCIAL ADVISORY MANAGEMENT CONSULTING Early Lessons Learned from DOE-EPRI Framework Experience Melissa Chan MA DPU.
Introduction Build and impact metric data provided by the SGIG recipients convey the type and extent of technology deployment, as well as its effect on.
Announcements Be reading Chapters 9 and 10 HW 8 is due now.
Distributed Intelligence Provides Self-Healing for the Grid
Stray Current Investigations A Method of Troubleshooting Stray Current on Underground Residential Distribution (URD) Loops Stacey Mighty Malcolm Distribution.
RT3b – André Smit, Siemens USA
Peter Hofmann Chief Engineer-Distribution Engineering Consolidated Edison, New York PQView User Group Meeting New York, NY August 31 – September 02, 2010.
Distribution Automation Plans in AEP Texas. Overview AEP Texas is deploying smart meters to roughly 1,000,000 customers The meters utilize Landis + Gyr.
© ABB Group June 10, 2015 | Slide 1 1MRS A self healing power system for the accurate fault location and zone concept T&D Smart Grids Europe 2012.
Substations. Substations Chapter 4 Substations Major types of equipment found in most transmission and distribution substations with their purpose,
Chapter 7 SYSTEM PROTECTION
Power Distribution Harmonics Case Study of 285-3F Chiller Plant Michael W. Harmon Principle Engineer Savannah River Nuclear Solutions, LLC Savannah River.
Copyright © The Texas A&M University System. 1 Distribution Fault Anticipation (DFA) Technology John S. Bowers, PECarl L. Benner, PE Vice President.
Scheduled Versus Event Driven Testing of Distribution Protection IEDs Dr. Alexander Apostolov, Benton Vandiver, Will Knapek, OMICRON electronics.
1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013.
AFCI Reaction to Utility Events. CenterPoint Energy 35 KV Distribution Capacitor Bank – Switched through an automated system.
Applying the Distribution System in Grid Restoration/NERC CIP-014 Risk Assessment Srijib Mukherjee, Ph.D., P.E. UC Synergetic.
SDG&E Electric Reliability Reporting CPUC Workshops May 26-27, 2015.
Transformer Taking the ratio of the two equations
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
WELCOME TO SEMINAR ON SCADA WELCOME TO SEMINAR ON SCADA Presented by: ANIL KUMAR RAUT Adm No:33IE/2k.
Need for protection Power system must be kept in operation continuously without major breakdowns This can be achieved in two ways: 1.Implement a system.
Outage Communication – Improving the Flow of Information Presented at the EEI Transmission, Distribution, and Metering Conference Tucson, Arizona October.
1 Power Quality EKT 451 CHAPTER 8. 2 Introduction Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This.
Queensland University of Technology CRICOS No J Protection of distributed generation connected networks with coordination of overcurrent relays.
Utility Engineers, PC.  Generation  Transmission  Distribution.
Introduction  Utilities transmit electricity over power lines into home as an alternating current (AC) wave.  This is how power travels through wiring.
Bywater Reliability Update Gary Huntley Entergy New Orleans, Inc. Regional Manager Entergy New Orleans, Inc. July 28, 2010.
ECE 498HZ: Power Distribution System Analysis
Survey of Smart Grid concepts and demonstrations Smart substation Ari Nikander.
Loop-Sectionalizing Automation Scheme Colin Hawthorne 4/26/2016.
Dr. Vidya Vankayala Director, Grid Modernization (604) Richard Guo
Protection of Power Systems
ELECTRICAL INSTRUMENTS ( service and utilization )
Distribution Automation The utilization of IEDs (Intelligent Electronic Devices) and advanced communications to unlock the benefits of operational efficiency.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Power System Protective Relaying-Part One
Protection of Power Systems
CURRENT ® Smart Grid Overview July SMART GRID = ENHANCED FUNCTIONALITY Smart Grid delivers more than advanced metering infrastructures: -safe.
Texas Power Line-Caused Wildfire Mitigation Project
Utility Needs and Smart Grid for Major Storm Events
Predictive-Based Maintenance Strategy
Advanced Fuse-Saving Techniques
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Chapter 7 System Protection
Application of DFA Technology for Improved Reliability and Operations
Power System Protective Relaying-Part One
EE362G Smart Grids: Architecture
Presentation transcript:

Presentation to the IEEE Power and Energy Society, Phoenix Chapter Radisson Hotel Phoenix Airport Phoenix, Arizona, March 22, 2012 Carl L. Benner, PE Sr. Research Engineer Assistant Director, Power System Automation Laboratory Department of Electrical and Computer Engineering Texas A&M University College Station, TX (979) , Bringing Visibility to Power Distribution System Operations and Engineering

2 © 2012 The Texas A&M University System. All rights reserved. In The Dark A typical distribution feeder consists of thousands of components: wires, insulators, capacitors, transformers, …. We generally have no idea of their condition, until the fail. This puts utilities in a mostly reactionary posture: wait until something breaks and then fix it (with exceptions, such as inefficient periodic capacitor maintenance). In addition, some problems (e.g., flickering lights) can be difficult to diagnose, resulting in incorrect diagnoses or no cause found. DFA technology provides greater visibility, or awareness, of system events and conditions, enabling multiple operational improvements, including proactive condition- based maintenance, accurate diagnosis of problems, etc.

3 © 2012 The Texas A&M University System. All rights reserved. DFA Overview Distribution Fault Anticipation (DFA) technology is an advanced, multi-purpose monitoring and diagnostic system that alerts users to faults, incipient failures, and other events and conditions on distribution systems. DFA technology has several self-imposed constraints: –Standard CTs and PTs as inputs –Minimal setup – no requirement for system model –No requirement for distributed electronics –No requirement for distributed communications (sub only) –Provide intelligence, not just data Two DFA-related patents have been granted, and several other applications are in process.

4 © 2012 The Texas A&M University System. All rights reserved. DFA Hardware Installation Photos

5 © 2012 The Texas A&M University System. All rights reserved. DFA Overview (contd) DFA devices in substations use sensitive triggering to record waveforms, even for events causing only slight changes to electrical waveforms. The devices then process those waveforms using sophisticated algorithms, to create actionable intelligence. A centralized server retrieves this actionable intelligence from the DFA devices and makes it available via web interface or . DFA complements other smart grid technologies, by enabling proactive condition-based maintenance, improved diagnosis and response to events, forensic investigations, etc, by providing a level of operational awareness and visibility not available with other technologies.

6 © 2012 The Texas A&M University System. All rights reserved. Historical Background EPRI supported early DFA research at Texas A&M University, starting in The initial goal was to predict, or anticipate, future failures of line apparatus. Foundational Hypothesis: Line currents and voltages reflect feeder activity, and early-stage apparatus failures affect electrical waveforms in specific, predictable ways. Therefore, continuously monitoring these signals provides the opportunity to detect and diagnose impending failures and other feeder activity.

7 © 2012 The Texas A&M University System. All rights reserved. Historical Background (contd) Early project efforts collected massive amounts of substation waveform data, by connecting instrumentation, configured with sensitive triggering, to conventional CTs and PTs on 70 utility feeders for multiple years. This produced the largest database ever created of high-fidelity electrical waveforms corresponding to normal and abnormal events on distribution systems. Correlating utility-documented apparatus failures with recorded waveforms enabled researchers to identify waveform characteristics and subsequently develop detection algorithms. The research process serendipitously demonstrated that applying intelligent algorithms to high-fidelity waveforms can provide considerable value beyond the anticipation function originally envisioned.

8 © 2012 The Texas A&M University System. All rights reserved. Current Status of DFA Technology Today DFA hardware and analysis algorithms detect voltage and current signatures indicative of multiple types of incipient failures. The research process revealed that electrical waveforms reflect a broad range of feeder activity, not just incipient failures. Intelligent Algorithms (Analytics) Reliability Condition-Based Maintenance Asset Management Improved Safety Outage Management Forensics Improved Power Quality O&M Cost Reduction Fault Anticipation Diagnosis of Protection Problems Applying on-line signal processing and pattern- matching algorithms to electrical waveforms can provide situational awareness and actionable intelligence for dispatchers, analysts, and repair crews.

9 © 2012 The Texas A&M University System. All rights reserved. Failure Types Documented in DFA Database Voltage regulator failure LTC controller misoperation Repetitive overcurrent faults Lightning arrestor failures Switch and clamp failures Cable failures –Main substation cable –URD primary cables –URD secondary cables –Overhead secondary cables Tree/vegetation contacts –Contacts with primary –Contacts with secondary services Pole-top xfmr bushing failure Pole-top xfmr winding failure URD padmount xfmr failure Bus capacitor bushing failure Capacitor problems –Controller misoperations –Failed capacitor cans –Blown fuses –Switch restrike –Switch sticking –Switch burn-ups –Switch bounce –Pack failure Certain types of failures occur frequently and are well understood. Other types of failures occur infrequently and few incidents have been documented. The DFA system was designed to accommodate improved algorithms, as ongoing field experience provides additional data.

10 © 2012 The Texas A&M University System. All rights reserved. Evolution of DFA Algorithms (Example) Early Algorithm: Generic Arcing Detection Arcing (capacitor) Arcing (series) Arcing (shunt) Arcing (clamp) Arcing (line switch) Arcing (clamp w/ low load) Arcing (clamp w/ high load) Arcing (switch w/ low load) Arcing (switch w/ high load) TIME

11 © 2012 The Texas A&M University System. All rights reserved. System-Level DFA Data Processing Paradigm DFA technology currently employs a distributed-processing paradigm, in which individual DFA devices perform the number crunching and deliver pre-analyzed events to a central server. This model provides multiple advantages as compared to models in which all devices send waveform data to a central server for processing. –The central server does not have to retrieve waveforms of routine events (e.g., motors starting, normal capacitor operations). The user can decide which types of events are important and configure the system to retrieve waveforms only for specific types of events. –Event reports can be delivered without the time delay of waiting for waveform retrieval. This provides a particular advantage where communications are limited. –Distributed processing promotes scalability for system-wide deployment. Current system implementation makes it straightforward to update algorithms on DFA devices as algorithms continue to evolve.

12 © 2012 The Texas A&M University System. All rights reserved. On-Line Signal Processing and Pattern Recognition Algorithms (Performed by DFA device in Substation) Line recloser* tripped 8% of phase-A load twice, but reclosed and did not cause outage Breaker lockout caused by fault-induced conductor slap Inputs: Substation CT and PT Waveforms *DFA algorithms analyze high-fidelity substation waveforms, to report hydraulic reclosers, switched line capacitors, apparatus failures, etc, without requiring communications to those devices. Algorithm OutputsDFA Algorithms Data Processing by Individual DFA Devices Failing hot-line clamp on phase B* Failed 1200 kVAR line capacitor* (phase B inoperable)

13 © 2012 The Texas A&M University System. All rights reserved. Division of Responsibilities between DFA Devices and Central Master Station Performed by DFA Devices at Substations Devices to Master Algorithm Outputs Selected Waveforms Interval Data Real-time Waveforms (on demand) Master to Devices Configurable Settings Central DFA Master Station - Format Web Reports - Provide Web Interface - Generate Waveform Plots - Format Reports - Send Reports Comm Link

14 © 2012 The Texas A&M University System. All rights reserved. System-Level DFA Data Processing Paradigm: An Illustrative Example Assume a particular feeder has a failing hotline clamp. A typical failure of this type may have the following characteristics: –It causes waveform variations the DFA system can detect and identify. –It produces these variations intermittently, typically for periods of a few minutes at a time, interrupted by quiescent periods often lasting for hours or days. –As measured from the substation, it causes variations on the order of a few primary RMS amperes and almost no primary RMS volts. (This illustrates the need for sensitive triggering.) –Over a period of days to weeks, it produce dozens, hundreds, or even thousands of individual events. The DFA device records each waveform anomaly, classifies it as a failing clamp, and labels the cluster of events as a failing clamp. The master station retrieves from the device the single report of failing clamp, and reports this via website and/or .

15 © 2012 The Texas A&M University System. All rights reserved. Sample DFA Report (via ) Incident: Remote fault occurred. Line recloser should have sectionalized feeder, but breaker tripped and locked out feeder. Utility noted apparent miscoordination, prompting need for investigation. DFA response: Minutes later, DFA ed a report indicating the feeder lockout was caused by fault-induced conductor-slap, not miscoordination. Location: The DFA report also provided fault-current estimate, enabling location of span that slapped and caused lockout. Special note: Police office had reported pole fire at site of conductor slap, but utility responder found no fire. Officer apparently had seen shower of sparks from slapping conductors.

16 © 2012 The Texas A&M University System. All rights reserved. Example: Fault-Induced Conductor Slap (FICS) and Predictable Feeder Lockouts 11/12/2007 Close Call As a result of a downstream fault, upstream wires swung together, resulting in fault-induced conductor slap (FICS). This caused a second fault and necessitated a trip by the substation breaker. Breaker reclosed twice and held, enabling feeder to sectionalize properly. DFA uses such episodes to warn of FICS susceptibility and provide information to locate slap. 12/02/2007 Breaker Lockout (43 minutes) FICS occurred in the same span as the 11/12/2007 episode. This episode caused the substation breaker to lock out. DFA uses such episodes to provide renewed warning of FICS susceptibility, including location. 11/13/2009 Breaker Lockout (36 minutes) 11/18/2009 Close Call 12/25/2011 Breaker Lockout (13 minutes)

17 © 2012 The Texas A&M University System. All rights reserved. Discussion of FICS Detection When FICS occurs, faults that should be cleared by sectionalizing devices instead create more widespread disruptions, including feeder lockouts. FICS typically occurs in an overhead span with unusual construction. DFA research has documented that utilities experiencing FICS mistakenly may believe they have a problem with protection coordination. Having limited information to guide investigations of these presumed protection problems, those investigations often result in no cause found. DFA reports FICS and provides guidance to find the offending span. DFA research demonstrates that spans susceptible to FICS experience it repeatedly. Intervals between episodes may be months or years, however, making it unlikely that personnel will recognize the connection between episodes. FICS impacts SAIDI and SAIFI, because each FICS episode tends to interrupt numerous customers for a significant period of time. DFA alerts the utility to FICS the first time it detects it electrically. Subsequent FICS interruptions that would have occurred without the DFAs alert constitute outages anticipated and averted.

18 © 2012 The Texas A&M University System. All rights reserved. Discussion of Recurrent Fault Detection Recurrent faults occur when incipient failures cause flashovers that momentary interruptions by sectionalizing reclosers temporarily heal. The fault recurs each time environmental or other conditions become conducive to flashover. A single incipient failure may cause many such episodes. DFA research has documented multiple causes for recurrent faults, including vegetation, cracked bushings, a death-grip bird, and an overlong jumper. Left uncorrected, recurrent faults typically evolve, eventually causing sustained outages and possibly other damage. DFA research indicates that customers often do not report momentary interruptions. For example, over a six-week period, a failing bushing flashed over five times, each time causing a momentary interruption for 900 customers. No customers complained until a sixth flashover caused a sustained outage. DFA analyzes each fault as it occurs. It also examines its historical records and alerts the utility when it detects multiple episodes of what appear to be the same fault, even if multi-day or multi-week intervals separate the episodes. DFA enables location of these incipient failures before they cause outages. One utility routinely uses a procedure it developed for finding recurrent faults, and has averted multiple sustained outages, thereby improving SAIDI and SAIFI.

19 © 2012 The Texas A&M University System. All rights reserved. Step 1: Learn of recurrent fault from DFA DFA reported two identical faults, 18 days apart. This circuit has 139 miles of exposure, making location of this incipient failure challenging. Step 2: Compare DFA info to system model at each line recloser (illustrated here for recloser R) Protection –DFA:Reported operation of 1ø recloser –Model:R is bank of 1ø hydraulic reclosers Momentary Load Interruption –DFA: Estimated 19-21% load interruption –Model:23% of load is beyond R Reclosing Interval –DFA: Reported 2-second open interval –Model:Reclosers at R have 2-second open Conclusion: Failure is downstream of recloser R (reduces search area by 74%). Sub R Circuit NS 344 (139 circuit miles) Detailed Example Recurrent Faults and Proactive Maintenance

20 © 2012 The Texas A&M University System. All rights reserved. Comparing DFA information with the feeder model identified which recloser was operating, indicating fault was downstream of that recloser. Once we focus downstream of the particular recloser, comparing the DFA fault-current estimate of 510A with the feeder model targeted area outlined in oval (~1% of total circuit miles). R Enlarged View of Line Downstream of R Sub NS 344 (139 circuit miles) R Detailed Example (contd) Recurrent Faults and Proactive Maintenance

21 © 2012 The Texas A&M University System. All rights reserved. Sub NS 344 (139 circuit miles) R Enlarged View of Oval Integrating DFA information with system model put failure inside oval area, encompassing 4 spans on either side of a tee (1% of circuit). Searching that area identified a arrestor that was flashing over. Replacing arrestor averted further interruptions and future outage to 53 customers. Detailed Example (contd) Recurrent Faults and Proactive Maintenance

22 © 2012 The Texas A&M University System. All rights reserved. Example Misdiagnosed Trouble T=0 hours: 16 customers with lights out Blown tap fuse, but no obvious system failure. New fuse holds. Close ticket. T=36 hours: Flickering lights in same area Crew hears buzzing transformer. Replace transformer. No buzzing. Close ticket. T=38 hours: Lights flickering again Now what do I do?

23 © 2012 The Texas A&M University System. All rights reserved. For three weeks, the DFA system had been reporting a failing clamp on this phase of this circuit. Without DFA, this single failure cost the utility four customer complaints, four truck rolls, and two unnecessary transformer change-outs. Equipping a dispatcher with this information would enable one trip and one clamp replacement. Example Misdiagnosed Trouble

24 © 2012 The Texas A&M University System. All rights reserved. Discussion of Switch/Clamp Failures As the jaws of hotline clamps and switches begin to fail, they produce unique arcing signatures, often detectable from substation CT/PT waveforms. The incipient-failure signature tends to occur for minutes at a time, interspersed with quiescent intervals lasting multiple days. A failing device may exhibit hundreds or even thousands of distinct arcing episodes. The DFA system uses intelligent reporting to provide current status of the incipient failure, without overwhelming personnel with alarms. DFA reports incipient failures of both clamps and switches, and it distinguishes between the two types with a high degree of confidence (80%/20%). DFA estimates the load past the failing device, enabling the utility to assess whether the failure likely involves a mainline device serving hundreds of customers, versus a device serving a small number of customers. Locating failing mainline devices would have high importance and should be relatively straightforward, because few such devices exist on a given feeder. DFA enables the utility to know the nature of the trouble, when a customer calls to report outage or flicker. This provides for better diagnosis, fewer unnecessary equipment change-outs, increased crew efficiency, and decreased no cause found incidents requiring call-backs.

25 © 2012 The Texas A&M University System. All rights reserved. A secondary (120/240V) underground cable arced for an extended period and then caused an outage. The DFA device at the substation detected the secondary arcing, as reflected to the primary, dozens of times over a 44-minute period. Reflecting 60A of measured primary current to the transformer secondary yields 60A x 60:1 turns ratio = 3600A of secondary current. Typical bursts of current lasted several hundred milliseconds. Repeated 3600A bursts of secondary current failed to blow the secondary fuse. The feeders 300+ amps of normal load current renders the fault current invisible to conventional monitoring. Detection requires sensitive triggering, such as used by the DFA system. Example Secondary (120/240V) Buried-Cable Arcing

26 © 2012 The Texas A&M University System. All rights reserved. Discussion of Secondary Buried-Cable Arcing This recent case is the second example of secondary buried- cable arcing documented by the DFA research program. The past case involved recurring secondary-arcing episodes. Some episodes arced for a few hundred milliseconds, but then self-extinguished for days. Others episodes tripped a CSP transformers breaker. Each time the breaker tripped, customers called and the utility had to dispatch a crew. When the crew reset the CSP breaker, it held, restoring normal service, so trouble tickets were closed with no cause found. This happened multiple times over a three-month period. Waveforms from the previous and current cases are being analyzed, to determine the degree to which they have similar, unique characteristics that could serve as the basis for implementing cause-specific reporting. Cause-specific reporting makes plausible the idea that, in the future, the DFA may be able to advise the nature of the trouble, when a customer calls to report outage or flicker. This would enable better diagnosis, increase crew efficiency, and decrease the number of no cause found incidents requiring subsequent call-backs.

27 © 2012 The Texas A&M University System. All rights reserved. Examples: Other Anomalies Case 1: Line burned down past line recloser and auto- sectionalizer. DFA helped determine which device failed. Case 2: In multiple cases, utility has used DFA to determine whether questionable reclosers were functioning properly, without removing them for offline testing. Case 3: DFA report is helping ongoing investigation to diagnose why a self-healing circuit did not respond properly. Case 4: On multiple occasions, DFA has helped a utility identify that a recloser stopped mid-sequence, failing to reclose or lock out, creating hazard for a crew that assumes that an open recloser is locked out.

28 © 2012 The Texas A&M University System. All rights reserved. Summary DFAs fundamental premise is that electrical waveforms reflect feeder activity, and that analysis of these waveforms by sophisticated on-line algorithms can improve the utilitys awareness, and therefore operation, of the system. Scope of DFA capabilities and value has expanded greatly beyond original focus on just anticipating failures. Utilities can use DFA website to learn of impending failures, misoperating equipment, protection-system anomalies, etc, and thereby make decisions and take corrective action. Current and anticipated efforts will examine integrating DFA information with other utility information systems and ing alerts to utilities. DFAs implementation anticipates and provides for future enhancements, as new waveform signatures are identified and algorithms are implemented.

Presentation to the IEEE Power and Energy Society, Phoenix Chapter Radisson Hotel Phoenix Airport Phoenix, Arizona, March 22, 2012 Carl L. Benner, PE Sr. Research Engineer Assistant Director, Power System Automation Laboratory Department of Electrical and Computer Engineering Texas A&M University College Station, TX (979) , Bringing Visibility to Power Distribution System Operations and Engineering