GUIDE TO OUR BUILDING (C1) - FUNCTIONALITY AND SAFETY Dr. Christian Stadler

Slides:



Advertisements
Similar presentations
COSHH ASSESSMENT TRAINING Essential Elements of a COSHH Form.
Advertisements

Liquid Nitrogen and Cryogenics Training Program
Chemical Storage. Objectives Separating incompatible materials Special hazards Flammable storage cabinets Corrosives cabinets Special versus general.
Chemistry safety Part 2.
Compressed Gas Safety for Laboratories
Housekeeping & Office Safety ©Consultnet Ltd.
General Safety Rules Chemistry 11.
When to put out a fire When to exit How to use a fire extinguisher Developed by Division of Occupational Safety and Health (DOSH) October, 2009 USING A.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Safe Use and Operation of Vacuum Lines
Molecular Materials Research Center Beckman Institute California Institute of Technology.
Copyright  Progressive Business Publications Blue Ridge Safety Association Safety Presentations Compressed Gasses.
Sputter Stand Safety Specifics Electrical Hazards High Voltage : Electrical power is required for the high voltage supply, gauging, system controller and.
 Violations of the following regulations WILL result in a loss of lab points.
A best practice guide to...
The Life Safety Surveyor Facility Tour
Zettl Group Safety Talk ~Fume Hoods~ 09/28/06 Takashi Ikuno.
Lab Inspections State Fire Marshal’s Office. Applicable Codes 1999 BOCA Business Occupancy 1999 BOCA Fire Prevention Code 2000 NFPA 101, Life Safety Code.
Fire Marshal’s Office Department of Environmental Safety LABORATORY FIRE SAFETY LABORATORY. FIRE SAFETY.
Laboratory Safety Advice to Students on Safety in the Geography Science Laboratories Safety and Security Handbook UNIVERSITY OF CAMBRIDGE DEPARTMENT OF.
Lab Safety Tips Environmental Health, Safety, & Risk Management Stephen F. Austin State University.
Chemical Fume Hood  A type of local ventilation device that is designed to limit the user's exposure to hazardous or noxious fumes, vapors or dusts.
Safety Awareness in Metro Science Labs. Students should never be in the lab unsupervised. If the teacher needs to leave the lab you should stop working.
Chemical Laboratory Safety Additional Information.
Proud program sponsor United States Fire Administration SMART PARENTS, SAFE KIDS HOME FIRE SAFETY.
 Safety at Home  Millions of people each year are seriously injured in their own homes  Most can be prevented.
1 Medical Equipment Safety Orientation to Laboratory Safety.
By: Clàudia Pellicer, Víctor Sánchez and Ana Lucía Londoño.
What you will learn in this session 1.The characteristics of fire, smoke and toxic fumes 2.Fire hazards involved in the working environment 3.Significant.
1 EETD SAFETY TOPICS FEBRUARY 28, 2013 Laboratory Area Housekeeping Awareness.
SITE SAFETY HAZARDS AND PROCEDURES. ELECTRICAL HAZARDS  Electricity is a serious workplace hazard.  Employees can be exposed to dangers such as : 
Safety Unit II.
Fire Prevention for Construction. Four classes of fires  A, B, C, and D 1a.
LABORATORY DESIGN AND SAFETY EQUIPMENT. 1. LABORATORY DESIGN a. Egress b. Traffic Patterns c. Floor Surfaces d. Master Controls e. Automated Detection.
OPERATE CALL POINT CLOSE DOORS DO NOT RUN FOLLOW THE EXIT SIGNS GO TO YOUR ASSEMBLY POINT IN THE EVENT OF FIRE.
Practical General chemistry Dr.Gharam Ibrahim. A -Lecturer Dr. Gharam Ibrahim; Office: third floor,chemistry department B -Instructors in the Laboratory:
CHEMISTRY SAFETY NOTES
FIRE PREVENTION. Fire Of the many hazards on site or at work, fires are the worst kind. They do a great deal of damage every year.  All fires, however.
Mr. Villa Fall Semester.  Carelessness  Insufficient knowledge  Taking unnecessary risks  Being in too great a hurry.
Add name of trust / organisation in box 1 and name of trainer in box 2. Delete THIS box.
Instructor:Mr. Wayne Wood McGill University Environmental Safety Office Chancellor Day Hall, room 615 Telephone:
Managing Hazardous Chemical Waste. What is Hazardous Waste EPA Definition: A material is a hazardous waste if due to its quantity, concentration, physical,
Housekeeping.
Health & Safety Risk Management
Lab Safety and Emergency Procedures. The Number One Rule In All Emergency Situations Don’t Panic, Move Quickly and Quietly.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Laboratory Procedures Chemical Management Emergency Laboratory Equipment m.inmagine.com CH5, CH6, CH10.
Safety In The Laboratory
What you will learn in this session 1.The characteristics of fire, smoke and toxic fumes 2.Fire hazards involved in the working environment 3.Significant.
 There are 70,000 fires each year in Canada  Preventing fires will lessen the chance of injury or death  Knowing what to do in case of fire can save.
Flammable Liquids Directorate of Training and Education
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
The Laboratory. Safety Rules Always…   Follow the teacher’s instructions   Push in chairs and keep walkways clear during experiments   Wear safety.
NTNU NanoLab Chemical Introduction Course By Trine Ø. Hjertås
Preventing Workplace Fires
GENERAL SAFETY PROCEEDURES & PRACTICES
What you will learn in this session
Laboratory: Health and Safety Specific Information's
(Modified from University Of South Carolina)
USING A FIRE EXTINGUISHER
Fume Hoods.
Fire Safety Presentation at
Essentials of Laboratory Safety
Essentials of Laboratory Safety
SAFETY IN THE LABORATORY
Safety Training Molecular Materials Research Center Beckman Institute
SAFETY DHO Chapter 12.
Laboratory Safety Symbols and Rules
Don’t be a Mad Scientist in the Lab
OPERATE CALL POINT CLOSE DOORS DO NOT RUN FOLLOW THE EXIT SIGNS GO TO YOUR ASSEMBLY POINT IN THE EVENT OF FIRE.
Presentation transcript:

GUIDE TO OUR BUILDING (C1) - FUNCTIONALITY AND SAFETY Dr. Christian Stadler

Getting in… Getting in (and getting out)

Online vs. offline

Getting in, without getting in trouble Always carry your transponder with you. Some doors will lock automatically behind you! Staircase doors will lock at 7 pm! Update your transponder every morning when you enter the building. It becomes inactive after less than two days of not updating it! Be aware of the different locking modes! They are explained in the information sheet you got when receiving your transponder. Contact Markus Braun (room ) in case of having trouble with doors, and, particularly, in case of loss of your transponder.

Getting out! No transponder needed! Just follow the signs!

Where to meet

Fire! (Please take care…) Escape ways, fire extinguishers, phone numbers, etc. Fire alarm Emergency stop for flammable gases 112 (emergency call) and/or (service center)

Fire! Avoiding contamination… Close open doors in the corridors!

Fire! Stopping flammable gases… Usually located at the end of a corridor, close to the stairway. Affects the whole floor!

Fire! Just another emergency stop Emergency stop for electricity and for flammable gases. Watch the room number! (Some ‘rooms’ actually are corridors)

Fire! Only run or try to fight it? Use an appropriate fire extinguisher! But please don’t risk your life. Powder D CO 2 foam ABC

Other legal(!) things in the corridors… streetwear lab coat only bottles

What else is new? Lights are switched off automatically in the late evening (at 9 pm?). Automatic lighting in the stairways and the basement (and even some automatic doors for easier transportation). Several rooms‘ temperature is controlled electronically.

Do not… …store any flammable materials in the corridors (not even in the lockers)! …park bicycles inside the building! …block doors open! …use the elevator in case of fire! …use multi-outlet power strips without previous permission by Mr. Brunner!

Laboratories: everything‘s changed! Dynamic ventilation system according to daytime and usage of fume hoods (with variable air volume flow and supportive flow technology). Automatic sashes and horizontally moveable access openings. Safer vacuum installations. Nitrogen, compressed air and cooling water everywhere. Lots of safety cabinets for flammable liquids. Workplaces at the windows with decent lighting and pretty much space.

Fume hoods, from bottom to top Handles and switches for all outlets inside the fume hood Safety cabinets for flammable liquids (maximum size is 10 l!)

Fume hoods, do not… …open more than one horizontal window! …block the supportive air stream with large objects or dozens of bottles! …use the fume hood for storage purposes! …use multi-outlet power strips! …leave your experiments unattended for a longer period of time!

Fume hoods: Controls green: fully operative; orange: low air flow mute alarm light open/close sash maximum air flow reduced air flow (night mode)

Ventilation: day vs. night acoustic alarm green: day mode, air volume okay (active from 7 am to 8 pm, can also be activated manually for 2 hours) air volume too low night mode, reduced air volume (active from 8 pm to 7 am) Please keep doors and windows closed! Otherwise the dynamic ventilation system can‘t operate properly and thus, fume hoods might not retain hazardous substances anymore. With NO warning!

Fume hood vs. ventilated cabin any kind of experimentsvery restricted usability (low air flow)

Vacuum installation increased safety, temperature controlled, ready for use controls (on/off for both pumps, acoustic alarm, mute alarm)

Electricity in the lab green: emergency power supply (no UPS!)fuses and residual-current device (“FI”) Check your installation before turning on again your devices! usually reserved for refrigerators and freezers

Night room and solvent distillation Fume hoods and cabins are equipped with argon fire extinction systems. Get out in case of alarm! All joints and tubings must be controlled daily! Heating mantles should be replaced by Heat-On attachments. Usage of AQUAcontroller is mandatory! What is missing here? A floor drain! 

Supply: transport routes The corridors on the ground floor MUST NOT be used for any transport of chemicals or any other materials! Use the basement floor for these transports! The doors there open automatically! Use appropriate containers and carts! Block the elevator when transporting hazardous materials or compressed-gas cylinders

Supply: How to block the elevator sensor for transponder 1.Activate sensor and call elevator. (Door opens.) 2.Load elevator and choose destination. 3.Activate sensor again. (Door closes and elevator starts moving.) 4.Take the staircase and activate sensor on the destination floor. (Door opens.) 5.Unload elevator and activate sensor again. (Elevator gets unblocked.)

Solvent supply and storage Ex zone !!! Use the exhaustion!Keep doors closed!Only 75 kg per base!

Gas supply You will never run out of Argon without warning! Alarm! (hydrogen leaking)

Waste disposal The rooms DON‘T have a fire extinguishing system! DON’T store flammable solvents outside cabins, fume hoods or cabinets, in order to avoid explosive atmosphere! Solid lab waste has to be disposed into the metallic dustbin! With the lid CLOSED! (Therefore, only small blue barrels can be used.)

Please don‘t forget… …to close the taps of the lab washer after each use. …to control all cooling water outlets before leaving the lab for a longer period of time. (It’s a good idea to unplug both cooling water connectors when cooling is not required. But never ever unplug only one of them! And always check if the tap is closed!) …to store safely all flammable liquids before leaving the lab. …that in our business even the smallest mistake can cause terrible damages or injuries. Our building has already seen fire and inundations. The next time it might destroy your working place. Please take care!