This article and any supplementary material should be cited as follows: Gerschutz MJ, Haynes ML, Nixon D, Colvin JM. Strength evaluation of prosthetic.

Slides:



Advertisements
Similar presentations
This article and any supplementary material should be cited as follows: Sanders JE, Severance MR, Swartzendruber DL, Allyn KJ, Ciol MA. Influence of prior.
Advertisements

This article and any supplementary material should be cited as follows: Cameron MH, Huisinga J. Objective and subjective measures reflect different aspects.
This article and any supplementary material should be cited as follows: Kannenberg A, Zacharias B, Pröbsting E. Benefits of microprocessor- controlled.
This article and any supplementary material should be cited as follows: Barton JE, Sorkin JD. Design and evaluation of prosthetic shoulder controller.
This article and any supplementary material should be cited as follows: Eicholtz MR, Caspall JJ, Dao PV, Sprigle S, Ferri A. Test method for empirically.
This article and any supplementary material should be cited as follows: Meier MR, Tucker KA, Hansen AH. Development of inexpensive prosthetic feet for.
This article and any supplementary material should be cited as follows: Smit G, Plettenburg DH, van der Helm FCT. Design and evaluation of two different.
This article and any supplementary material should be cited as follows: Wininger M, Crane B. Effect of interpolation on parameters extracted from seating.
This article and any supplementary material should be cited as follows: Larson RD, McCully KK, Larson DJ, Pryor WM, White LJ. Lower-limb performance disparities:
This article and any supplementary material should be cited as follows: Larson GE, Norman SB. Prospective prediction of functional difficulties among recently.
This article and any supplementary material should be cited as follows: Wang H, Tsai C, Jeannis H, Chung C, Kelleher A, Grindle GG, Cooper RA. Stability.
This article and any supplementary material should be cited as follows: Chien CS, Huang TY, Liao TY, Kuo TY, Lee TM. Design and development of solar power-assisted.
This article and any supplementary material should be cited as follows: Smit G, Bongers RM, Van der Sluis CK, Plettenburg DH. Efficiency of voluntary opening.
This article and any supplementary material should be cited as follows: Safari MR, Rowe P, Buis A. Examination of anticipated chemical shift and shape.
This article and any supplementary material should be cited as follows: Nilsson L, Durkin J. Assessment of learning powered mobility use— Applying grounded.
This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretest reliability and rater agreements.
This article and any supplementary material should be cited as follows: Tsai J, Rosenheck RA. Use of group treatment among case managers in Department.
This article and any supplementary material should be cited as follows: Wolf EJ, Everding VQ, Linberg AL, Schnall BL, Czerniecki JM, Gambel JM. Assessment.
This article and any supplementary material should be cited as follows: Webster JB, Hakimi KN, Williams RM, Turner AP, Norvell DC, Czerniecki JM. Prosthetic.
This article and any supplementary material should be cited as follows: Morgan P, Embry A, Perry L, Holthaus K, Gregory CM. Feasibility of lower- limb.
This article and any supplementary material should be cited as follows: Laciuga H, Rosenbek JC, Davenport PW, Sapienza CM. Functional outcomes associated.
This article and any supplementary material should be cited as follows: LePage JP, Lewis AA, Washington EL, Davis B, Glasgow A. Effects of structured vocational.
This article and any supplementary material should be cited as follows: Belter JT, Segil JL, Dollar AM, Weir RF. Mechanical design and performance specifications.
This article and any supplementary material should be cited as follows: Littman AJ, Koepsell TD, Forsberg CW, Haselkorn JK, Boyko EJ. Preventive services.
This article and any supplementary material should be cited as follows: Watson EC, Cosio D, Lin EH. Mixed-method approach to veteran satisfaction with.
This article and any supplementary material should be cited as follows: Garcia-Mendez Y, Pearlman JL, Cooper RA, Boninger ML. Dynamic stiffness and transmissibility.
This article and any supplementary material should be cited as follows: Collinger JL, Boninger ML, Bruns TM, Curley K, Wang W, Weber DJ. Functional priorities,
This article and any supplementary material should be cited as follows: Walter JS, Thomas D, Sayers S, Perez-Tamayo RA, Crish T, Singh S. Respiratory responses.
This article and any supplementary material should be cited as follows: Stinson JM, Collins RL, Maestas KL, Pacheco V, LeMaire A, Benge J. Dependency aspect.
This article and any supplementary material should be cited as follows: Sanders JE, Severance MR, Allyn KJ. Computer-socket manufacturing error: How much.
This article and any supplementary material should be cited as follows: Juhnke D, Beck JP, Jeyapalina S, Aschoff HH. Fifteen years of experience with Integral-Leg-Prosthesis:
This article and any supplementary material should be cited as follows: Kang YS, Park YG, Lee BM, Park HS. Biomechanical evaluation of wrist- driven flexor.
This article and any supplementary material should be cited as follows: Wu TM, Chen DZ. Biomechanical study of upper-limb exoskeleton for resistance training.
This article and any supplementary material should be cited as follows: Gerschutz MJ, Haynes ML, Nixon DM, Colvin JM. Tensile strength and impact resistance.
This article and any supplementary material should be cited as follows: Hind J, Divyak E, Zielinski J, Taylor A, Hartman M, Gangnon R, Robbins J. Comparison.
This article and any supplementary material should be cited as follows: Barfield JP, Malone LA. Perceived exercise benefits and barriers among power wheelchair.
This article and any supplementary material should be cited as follows: Komolafe O, Wood S, Caldwell R, Hansen A, Fatone S. Methods for characterization.
This article and any supplementary material should be cited as follows: Guidali M, Keller U, Klamroth-Marganska V, Nef T, Riener R. Estimating the patient’s.
This article and any supplementary material should be cited as follows: Velozo CA, Woodbury ML. Translating measurement findings into rehabilitation practice:
This article and any supplementary material should be cited as follows: Ferguson-Pell M, Ferguson-Pell G, Mohammadi F, Call E. Applying ISO Standard.
This article and any supplementary material should be cited as follows: Gebrosky B, Pearlman J, Cooper RA, Cooper R, Kelleher A. Evaluation of lightweight.
This article and any supplementary material should be cited as follows: Chard KM, Ricksecker EG, Healy ET, Karlin BE, Resick PA. Dissemination and experience.
This article and any supplementary material should be cited as follows: Mahajan HP, Spaeth DM, Dicianno BE, Brown K, Cooper RA. Preliminary evaluation.
This article and any supplementary material should be cited as follows: Fatone S, Dillon M, Stine R, Tillges R. Coronal plane socket stability during gait.
This article and any supplementary material should be cited as follows: Alcaide-Aguirre RE, Morgenroth DC, Ferris DP. Motor control and learning with lower-limb.
This article and any supplementary material should be cited as follows: Fu J, Jones M, Jan Y. Development of intelligent model for personalized guidance.
This article and any supplementary material should be cited as follows: Ishikawa S, Stevens SL, Kang M, Morgan DW. Reliability of daily step activity monitoring.
This article and any supplementary material should be cited as follows: Ganz DA, Almeida S, Roth CP, Reuben DB, Wenger NS. Can structured data fields accurately.
This article and any supplementary material should be cited as follows: Hansen A, Nickel E, Medvec J, Brielmaier S, Pike A, Weber M. Effects of a flat.
This article and any supplementary material should be cited as follows: Sinitski EH, Lemaire ED, Baddour N. Evaluation of motion platform embedded with.
This article and any supplementary material should be cited as follows: Hafner BJ, Sanders JE. Considerations for development of sensing and monitoring.
This article and any supplementary material should be cited as follows: Redfield MT, Cagle JC, Hafner BJ, Sanders JE. Classifying prosthetic use via accelerometry.
This article and any supplementary material should be cited as follows: Lee WC, Wong WY, Kung E, Leung AK. Effectiveness of adjustable dorsiflexion night.
This article and any supplementary material should be cited as follows: Koester HH, Simpson RC. Method for enhancing text entry rate with single-switch.
This article and any supplementary material should be cited as follows: Berning K, Cohick S, Johnson R, Miller LA, Sensinger JW. Comparison of body-powered.
This article and any supplementary material should be cited as follows: Hebert JS, Lewicke J. Case report of modified Box and Blocks test with motion capture.
This article and any supplementary material should be cited as follows: Troche MS, Rosenbek JC, Okun MS, Sapienza CM. Detraining outcomes with expiratory.
This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of- the-art.
This article and any supplementary material should be cited as follows: Ficanha EM, Rastgaar M, Kaufman KR. Ankle mechanics during sidestep cutting implicates.
This article and any supplementary material should be cited as follows: Tsai J, Rosenheck RA. Homeless and nonhomeless VA service users likely eligible.
This article and any supplementary material should be cited as follows: Ghoseiri K, Safari MR. Prevalence of heat and perspiration discomfort inside prostheses:
This article and any supplementary material should be cited as follows: Sensinger JW, Lipsey J, Thomas A, Turner K. Design and evaluation of voluntary.
This article and any supplementary material should be cited as follows: Sloan DM, Bovin MJ, Schnurr PP. Review of group treatment of PTSD. J Rehabil Res.
This article and any supplementary material should be cited as follows: Senra H, Vieira CR, Nicholls EG, Leal I. Depression and experience of vision loss.
This article and any supplementary material should be cited as follows: Smit G, Plettenburg DH. Comparison of mechanical properties of silicone and PVC.
This article and any supplementary material should be cited as follows: Souza AE, Pearlman JL, Cooper R, Kelleher A, Gebrosky B, Cooper RA. Evaluation.
This article and any supplementary material should be cited as follows: Kahle JT, Highsmith MJ. Transfemoral sockets with vacuum-assisted suspension comparison.
This article and any supplementary material should be cited as follows: Johnson WB, Fatone S, Gard SA. Modeling effects of sagittal-plane hip joint stiffness.
This article and any supplementary material should be cited as follows: Major MJ, Johnson WB, Gard SA. Interrater reliability of mechanical tests for functional.
This article and any supplementary material should be cited as follows: Boone DA, Kobayashi T, Chou TG, Arabian AK, Coleman KL, Orendurff MS, Zhang M.
Presentation transcript:

This article and any supplementary material should be cited as follows: Gerschutz MJ, Haynes ML, Nixon D, Colvin JM. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets. J Rehabil Res Dev. 2012;49(3):405–26. Slideshow Project DOI: /JRRD JSP Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets Maria J. Gerschutz, PhD; Michael L. Haynes, MS; Derek Nixon, BS; James M. Colvin, MS

This article and any supplementary material should be cited as follows: Gerschutz MJ, Haynes ML, Nixon D, Colvin JM. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets. J Rehabil Res Dev. 2012;49(3):405–26. Slideshow Project DOI: /JRRD JSP Aim – Assess static failure loads for check sockets (CSs), copolymer sockets (CPs), and definitive laminated sockets (DLs). – Compare facilities, fabrication material and methods, and socket thickness. Relevance – While International Organization for Standardization (ISO) standards exist for most lower-limb prosthetic components, they do not include prosthetic sockets.

This article and any supplementary material should be cited as follows: Gerschutz MJ, Haynes ML, Nixon D, Colvin JM. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets. J Rehabil Res Dev. 2012;49(3):405–26. Slideshow Project DOI: /JRRD JSP Methods We used modified ISO to measure static failure loads of prosthetic sockets. – Compared them with criteria set by this standard for other components. Static socket testing configuration.

This article and any supplementary material should be cited as follows: Gerschutz MJ, Haynes ML, Nixon D, Colvin JM. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets. J Rehabil Res Dev. 2012;49(3):405–26. Slideshow Project DOI: /JRRD JSP Results CS Static Strength – Influenced by thickness, material choice, fabrication method. CP Static Strength – Depended on thickness, fabrication method. DL Static Strength – Influenced by material choice, fabrication method. Ductile loading criterion: – Most CSs and all CPs failed in a ductile mode. Brittle loading criterion: – Most DLs failed in a brittle mode.

This article and any supplementary material should be cited as follows: Gerschutz MJ, Haynes ML, Nixon D, Colvin JM. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets. J Rehabil Res Dev. 2012;49(3):405–26. Slideshow Project DOI: /JRRD JSP Conclusions Our results provide: – Foundation for understanding quality of prosthetic sockets. – Insight into possible routes for improving current care delivered to patients. – Comparative basis for future technology.