9 March 2004 GIFTS Blackbody Subsystem Critical Design Review Blackbody Controller 9 March 2004 Scott Ellington 608 263-6771.

Slides:



Advertisements
Similar presentations
SAAB SPACE 1 The M2 ASIC A mixed analogue/digital ASIC for acquisition and control in data handling systems Olle Martinsson AMICSA, October 2-3, 2006.
Advertisements

Daikin Altherma™ Troubling Shooting
Manchester 09/sept/2008A.Falou & P.Cornebise {LAL-Orsay}1 CALICE Meeting/ Manchester Sept 2008 SLAB Integration & Thermal Measurements.
Energy in Thermal Processes
Applications Team Sensing Products
CHE/ME 109 Heat Transfer in Electronics LECTURE 10 – SPECIFIC TRANSIENT CONDUCTION MODELS.
Overview of Temperature Measurement ME 115 Figures are from “Practical Guidelines for Temperature Measurement” unless otherwise notedwww.omega.com.
© 2012 Pearson Education. Upper Saddle River, NJ, All rights reserved. Electronic Devices, 9th edition Thomas L. Floyd Electronic Devices Ninth.
Resistance. This is a measure of a materials opposition to the flow of current through it. Unit: Ohms ( Ω )
9 March 2004 GIFTS Blackbody Subsystem Critical Design Review Blackbody Mechanical Design Doug Adler 9 March 2004.
David MacNair POWER SUPPLY 3/30/20061 Ethernet Power Supply Controller.
9 March 2004 GIFTS Blackbody Subsystem Critical Design Review Temperature Uncertainty Budget and Calibration Fred Best 9 March 2004.
EUSO BALLOON Battery Power Pack (PWP) RIKEN/UAH Héctor Prieto, Katsuhiko Tsuno, Marco Casolino.
Electric (conduction) current I I According to general agreement its direction is chosen to coincide with the direction in which positive.
STEREO IMPACT SEP Critical Design Review 2002-Nov-20 TvR IMPACT/SEP Thermal Design John Hawk, GSFC (301)
1 Thermal Investigation for Accurate Temperature Measurement Team TCTJ Truc Le Cedric Toguem Jonathan Newman.
20a - 1 NASA’s Goddard Space Flight Center Attitude Control System (ACS) Eric Holmes, Code 591 Joe Garrick, Code 595 Jim Simpson, Code 596 NASA/GSFC August.
AMS02 TIM CAB Project Status JSC, January 2007 Prepared by H. Cuesta / G. Muñoz.
St Columba’s High School Electricity and Electronics Op-amps.
THEMIS Instrument PDR 1 UCB, October 15-16, 2003 IDPU Mechanical / Thermal Preliminary Design Review Heath Bersch University of California - Berkeley.
An evaluation of HotSpot-3.0 block-based temperature model
GLAST LAT ProjectDelta PDR/Baseline Review July 29-August 1, 2002 Section 7.3 AntiCoincidnce Detector Technical Status 1 GLAST Large Area Telescope: AntiCoincidence.
9 March 2004 GIFTS Blackbody Subsystem Critical Design Review Action Items From PDR Fred Best 9 March 2004.
THEMIS Instrument CDR 1 UCB, April 19-20, 2004 Boom Electronics Board (BEB) Engineering Peer Review Apr. 20, 2004 Hilary Richard.
1 LECTURE 3. Contents 3.Measurement methods 3.1.Deflection, difference, and null methods 3.2.Interchange method and substitution method 3.3.Compensation.
One-Dimensional Steady-State Conduction
For Official Use Only; Information herein NOT Approved for Export; Contains Proprietary Protected Information; NOT for Public Release 1 WIPER PDR Stanford,
Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL
GLAST LAT ProjectCAL Peer Design Review, Mar 17-18, 2003 P. Prat CNRS/IN2P3-LLR Ecole Polytechnique GLAST Large Area Telescope Calorimeter Subsystem Gamma-ray.
1 1.6 Op-Amp Basics Basic Op-Amp Op-amp equivalent circuit Practical (R i = high, R o = small)Ideal (R i =∞, R o = 0)
Thermal Subsystem Peer Review Objective: To maintain all components of the space craft within their specific temperature range.
A Method for Correcting for Telescope Spectral Transmission in the Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) John D. Elwell, Deron.
STEREO IMPACT Critical Design Review 2002 November 20,21,22 Acuña1 MAGNETOMETER (MAG) M. H. Acuña NASA/GSFC Laboratory for Extraterrestrial Physics.
SDR 7 Jun Associated Electronics Package (AEP) Curtis Ingraham.
Solar Probe Plus A NASA Mission to Touch the Sun March 2015 Instrument Suite Name Presenter's Name.
Radioactive source and cosmic-ray test for the MWPC Davide Pinci on behalf of the Frascati-Roma1 MWPC group.
1 BROOKHAVEN SCIENCE ASSOCIATES Power Supply Status George Ganetis Power Supply Status ASAC Review October 22-23, 2009.
EUSO BALLOON Battery Power Pack (PWP) RIKEN/UAH Héctor Prieto, Katsuhiko Tsuno, Marco Casolino 1.
1 Four-Wire RTD measurement: Error Analysis/ Experimental Results.
3 He Fridge SPIRE WE Review Dec. 6-7, IFSI 1 3 He Sorption Fridge “Cooler” WE Preliminary Design Presented by: L. Rodriguez / CEA/SAp. Subsystem.
109-IDPU-Chassis-Donakowski 1 30 Sep – 01 Oct 2009DRAFT RBSP EFW ICDR 109-IDPU-Chassis-Donakowski IDPU Chassis Mechanical Design and Development Bill Donakowski.
C osmic R Ay T elescope for the E ffects of R adiation CRaTER Thermal Analysis Huade Tan 6/27/05.
Thermal Analysis Assumptions: Body Temperature (Environment) is 37˚C Heat distribution on outside of device will be modeled via FEA Heat transfer method.
RBSP Radiation Belt Storm Probes RBSP Radiation Belt Storm Probes RBSP/EFW CDR /30-10/1 535 IDPU Chassis Bill Donakowski Mechanical Engineer UCB/SSL.
1 With the deflection method, the result of the measurement is entirely determined by the readout of the measurement device. The difference method indicates.
Spacecraft Level Testing and Verification Part 3 1.
Overview of the ESS Linac Cryogenic Distribution System
C osmic R Ay T elescope for the E ffects of R adiation CRaTER Pre-Ship Review (I-PSR) Thermal Analysis Christine Cottingham LM/GSFC 545 Hume Peabody GSFC.
C osmic R Ay T elescope for the E ffects of R adiation 27 June 2005 Digital Engineering Digital Sub-System Bob Goeke.
3. Signal conditioning Sensors are very rarely directly connected to the registering instruments, as the signal may be too weak, incompatible or noisy.
Rose Navarro HMI Lead Thermal Engineer
Status of the DSP/ASPOC EM
1.6 Op-Amp Basics Basic Op-Amp Practical (Ri = high , Ro = small)
Electronic Devices Ninth Edition Floyd Chapter 17.
Calorimeter Mu2e Development electronics Front-end Review
Bill Donakowski Mechanical Engineer UCB/SSL
CRaTER Pre-Environmental Review (I-PER) Engineering Requirements/Design Updates Bob Goeke September 10-11, 2007.
GLAST Large Area Telescope:
UNIT-5 Design of CMOS Op Amps.
Switching DC Power Supplies
A.M.Villavan Sai Lalith Rohit K.Anudeep
Thermal Control In spacecraft design, the Thermal Control System (TCS) has the function to keep all the spacecraft parts within acceptable temperature.
ECE Engineering Design Thermal Considerations
LAT Requirements Verification in TVAC
Image Stabilization System (ISS)
Overview of Temperature Measurement ME 115
Thermocouple formation on PC Boards Content by Ian Williams and Thomas Kuehl Precision Amplifiers Applications Engineering Texas Instruments Incorporated.
CRaTER Pre-Environmental Review (I-PER) Engineering Requirements/Design Updates Bob Goeke September 10-11, 2008.
JOSH STAMPS ROBIN HEGEDUS
Command and Data Handling
Presentation transcript:

9 March 2004 GIFTS Blackbody Subsystem Critical Design Review Blackbody Controller 9 March 2004 Scott Ellington

9 March 2004 Slide 2 Blackbody Controller Performance Requirements and Design Overview Changes since PDR Controller Operation Electronics Error Budget Power Budget Supporting Analysis Part Selection Engineering Model Test Results Controller Verification Plan Calibration Overview

9 March 2004 Slide 3 Subsystem Block Diagram

9 March 2004 Slide 4 Key Electronics Requirements Blackbody Temperature Measurement -Hot Blackbody Range 0 to +40˚C -Ambient Blackbody Range -40 to 0˚C -Long-term accuracy ±0.03˚C (Electronics only) -Measurement Update Rate 2.7 Hz Blackbody Temperature Control -Constant Temperature and Constant Power Modes -HBB Control Temperature Range 0 to +40˚C -ABB Control Temperature Range -40 to 0˚C -Set Point Resolution ≤ 0.2˚C -Set Point Drift ≤ 0.005˚C, for a Controller board temperature change of 1°C Electronics Power 1.2 W, maximum

9 March 2004 Slide 5 Changes Since PDR Control of both blackbodies Maximum total power increases from 3.0 to 5.2 W Redundant heater drivers deleted, dual heaters retained Add low power “Reset” mode Default operation for both blackbodies is constant temperature Add autoranging of temperature measurement ranges Change ±15V supplies to ±12V Add primary overtemperature protection Increase measurement update rate from 2.0 to 2.7 Hz Command and data interface modified as necessary Blackbody thermal environment is colder Increase electronics power from 1.0 to 1.2 W Change controller operating temperature range to -55 to +50°C. (Accuracy guaranteed -40 to +30°C only)

9 March 2004 Slide 6 Blackbody Controller Operation

9 March 2004 Slide 7 Operational Commands Blackbody Modes -Constant Temperature -Constant Power Set Points Control Thermistor Select Temperature Measurement Range –Range Select –Autorange On/Off Reset Mode

9 March 2004 Slide 8 Electronics Error Budget Summary

9 March 2004 Slide 9 Power Budget Summary Worst-case for cold side of orbit

9 March 2004 Slide 10 Model Transient Response 0.14 W Blackbody Power Step Time (sec) Temperature Error

9 March 2004 Slide 11 Model Orbital Response Blackbody Power Temperature Error Time (Hours)

9 March 2004 Slide 12 Measurement Ranges and Self-Calibration Thermistor Voltage (V) ADC Output Self-Calibration Point

9 March 2004 Slide 13 Self-Calibration Example Self-Calibration Point CAL A CAL B NANA NBNB ADC Output Thermistor Voltage (V) VAVA VBVB

9 March 2004 Slide 14 Self-Calibration N A = Value at self-calibration point A N B = Value at self-calibration point B V A = Voltage at self-calibration point A (known) V B = Voltage at self-calibration point B (known) K 1 = Gain constant K 2 = Offset constant N = Value at measurement of unknown temperature V = Thermistor voltage at unknown temperature T = Blackbody Temperature Self-calibration corrects for drift of gain and offset in electronics Residual error depends mainly on stability of precision resistors

9 March 2004 Slide 15 Controller Parts Selection Summary

9 March 2004 Slide 16 Non-Standard Parts

9 March 2004 Slide 17 Radiation and Shielding Total mission radiation dose assumed to be 100K Rad, including X2 safety factor RH108A (Op Amp) requires additional shielding to 20K Rad 7872RPFS (ADC) and HS (Mpx) performance improves with additional shielding 110 mils (2.8mm) of additional aluminum shielding is provided for these parts

9 March 2004 Slide 18 Neglected radiation, assumed conduction only to edges at 50°C Modeled board as single layer with equivalent lateral conductivity based on copper and polyimide layer thicknesses Heat flux into board assumed uniform over each component’s area Total power dissipation is 1.2W Components shown total 0.81W, remaining 0.39W evenly distributed over remaining board surface Heat to left edge is 0.43W, heat to right edge 0.77W Maximum temperature is 54°C Temperature results PWB Thermal Analysis Board layout Wedgelock

9 March 2004 Slide 19 Parts Derating Summary Note: Maximum PWB temperature 55°C

9 March 2004 Slide 20 Engineering Model Test Set-up

9 March 2004 Slide 21 Engineering Model Test Results Tested at +25° C only –Data Interface –Resistance Measurement –Temperature Control Preliminary results meet specifications

9 March 2004 Slide 22 Engineering Model 1 Photograph

9 March 2004 Slide 23 Flight Unit Acceptance Test Plan

9 March 2004 Slide 24 Electrical Test Outline

9 March 2004 Slide 25 Flight Test Set-up

9 March 2004 Slide 26 Testing Issues SDL Bus Simulator built with commercial components may not allow testing of Blackbody Controller over entire temperature range. –SDL Bus Simulator required for all electrical tests –SDL Bus Simulator and Blackbody Controller must be installed on the common motherboard in close proximity –Temperature Tests of Blackbody Controller require SDL Bus Simulator to operate over the same temperature range Motherboard does not allow direct measurement of Blackbody Controller power supply currents.

9 March 2004 Slide 27 Calibration Overview Direct Temperature Calibration Only No Temperature to Resistance or Data to Resistance Calibration –Would require extremely precise resistance references –Intermediate calibration allows accumulation of errors –Interchangeability is not an issue Acceptance Test Resistance Measurements –Verify measurement ranges –Linearity