Dewatering Equipment.

Slides:



Advertisements
Similar presentations
An Introduction To Marine Steam Propulsion Plant [Source: US Navy]
Advertisements

Fire Apparatus Pump Theory
2.3 Waste Management – Revised IBTS
Learning Objective 1 Describe the safety considerations taken when service testing a fire hose.
ADX 150 – Engine Repair ADX 170 – Climate Controls
Basic Refrigeration Cycle
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use various hose appliances and tools, prepare a test site for service.
Firefighting Foam.
NEAR MISS SAFETY REPORT TRAINING DIVISION. The purpose of this Near Miss Safety Report is not to place blame, fault or be used for any disciplinary action.
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
INVESTIGATION LESSON TOPIC 1.9 IDENTIFY IDENTIFY the need for principle of, and equipment required to investigate for fire, flooding and structural damage.
WASH Cluster – Groundwater Pumping GWP GWP1 1 Groundwater Pumping Session 1 Handpumps.
Augmenting Fire Standpipe Systems
DEWATERING PUMP.
Tie Rod Case Study.
3.4.6 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Compressors Knowledge of the processes involved in maintaining.
Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
Damage Control II Objectives DC Actions & Reports DC Actions & Reports Classes of Fires & Combating them Classes of Fires & Combating them Firefighting.
Proper Pump Installation Practices
Basics of Pump Vigyan Ashram, Pabal.
Introduction to Hydraulics ClassAct SRS enabled. In this presentation you will: identify the fundamental parts of a hydraulic system and safety issues.
Characteristics of Water
Bilge System.
Purpose of Standpipe and Hose Systems
Pump Installation Vigyan Ashram, Pabal.
Ship Design & Engineering
Damage Control Systems and Equipment Objectives A. Know the 4 classes of fire and the firefighting agents, equipment, and procedures to extinguish.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
Components of Centrifugal pumps
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
PLATFORM UTILITIES PAB 2073 Reference: PCSB/PMO document.
1402 Hybrid Firefighter II 6th Edition Chapter 15 — Fire Hose South Carolina Fire Academy.
Firemain S W O T E A M D G C N R L American LaFrance LT.311.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Investigator Casualty Guide Identifying & Assessing Damage “Looking Deeper” March 2013.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
Copyright  Progressive Business Publications Electrical Safety.
FLOODING OVERVIEW FLOWCHART
Unit 4: General Safety Practices
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
SUBJECT CODE NAME OF SUBJECT TOPIC :::::: FLUID POWER ENGINEERING CENTRIFUGAL PUMP Parul Institute of Engineering & Technology.
Firefighter III Module B Water Supply (4-19) (4-19)
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
Fire Fighting Systems Fi Fi Mains ●White System: This system has a lower output as far as volume goes. This main supplies 3x Eductor/Hydrants (500 gpm).
Weekly Checks Monday – VSP Room Tuesday – Pilothouse System Controls Wednesday – Starboard / Engine Room Thursday – Foam Room Friday – Port / Engine Room.
Raw Water System Flush By introducing fresh water into the cooling system, growth of sea life is reduced or eliminated keeping the raw water cooling pipes.
Red/Green Fire Fighting Systems Fi Fi Mains ●Red System: Port Side Fire Main supplies two Monitors. M7 (6000) gpm on centerline on the fwd Wheelhouse top.
Fire/General Service/Ballast Pumping Systems
Bilge Pumping Systems General Locations.
Machinery Cooling Water System Locations and Operations.
R ECIPROCATING P UMPS Prof. Shrikant M. Harle Dept of Civil Engg PRMCEAM, Badnera.
PUMPS. Types of pumps 1.Roto-dynamic pumps i.Centrifugal pump ii.Axial flow pump 2.Displacement pumps i.Reciprocating pump ii.Rotary pumps 3.Other types.
4.0 Pumps.
Friday – port side engine room weekly checks
General Safety Practices
HYDRAULICS & PNEUMATICS
REPORT IN AUX MAC PAQUIBOL, MARK ANGELO B. ME31-A1 ENGR. ALMOJUELA.
Flammable and Combustible Liquids
Fuel Supply System Service
Booster Hose Reel Location/Operations.
Pumps and Lift Stations
Firefighting equipment
Fire-Fighting Equipment
PUMPS AND DRIVERS NCCER
Essentials of Fire Fighting Maintenance and Testing Responsibilities
Presentation transcript:

Dewatering Equipment

Enabling Objectives: Identify the capabilities and uses of installed drainage Identify the capabilities and uses of portable dewatering equipment Rig and use a peri-jet eductor to dewater a flooded compartment. Note: All objectives are in accordance with NSTM 079 Vol. 2, NWP 3-20.31, COMNAVSURFPACINST 3541.4B, COMNAVSURFLANTINST 3541.1C, NSTM Chapter 555, NSTM 079 Vol. 3

Drainage and Flushing Systems Definition: Systems of piping onboard ships, with or without plumbing facilities, installed for removing waste and flooding water from within the hull.

Principle Drainage Systems: Main drainage Secondary drainage Plumbing and deck drains

Main drainage Serves all main machinery spaces Note: On some ships, it may extend forward and aft of the machinery compartment. Drains machinery space bilges Drains floodable voids Drains fuel tanks ballasted with sea water

Main drainage (cont.) Pumps Steam driven reciprocating (older ships) Turbine or motor driven centrifugal Eductors (jet pumps)

Secondary drainage Drains spaces forward and aft of the main machinery spaces The secondary drainage system is an independent system with it’s own pumps and eductors

Secondary drainage (cont.) Pumps Electrical motor driven centrifugal Eductors (jet pumps) Portable electric submersible pumps

Plumbing and deck drains Provided to drain compartments within the ship by gravity. Gravity drainage piping is installed most extensively in compartments above the waterline

Weather deck drains Flooding danger exists with gravity type drains. Such piping usually pierces the skin of the ship and passes through the watertight decks. As a damaged ship lists to one side or settles more deeply, water will flow back through drainage piping.

Overboard discharge connection Allows for discharge of liquids through the hull of the ship Located on the damage control deck and as close to the damage control deck as possible Located on both port and starboard sides, and through the hull of each main transverse subdivision Made flush with the outer hull surface

Overboard discharge connection (cont.) Size and type: Inboard end has a 4 inch female swivel hose connection attached to a 4 inch male-2 1/2 inch female swivel hose adapter coupling A 2 1/2 inch hose cap is attached to the adapter

Drainage of magazines All magazines having sprinkler systems have drainage capability Magazines located above and adjacent to the weather deck, drain through a check valve installed in the bulkhead to the weather deck

Drainage of magazines (cont.) For magazines not located adjacent to the weather deck, overboard drainage is provided through deck drains in the magazine with independent drain piping having a check valve at the shell

Drainage of magazines (cont.) Magazines which cannot be drained overboard by gravity are drained by portable pumps, either through overhead access or a drain pipe installed through the bulkhead to an adjacent handling room, access, or passage. The drain pipe is installed in the bulkhead at a point close to the deck and fitted with a hose valve

Portable dewatering equipment

P-100 The P-100 pump unit is an air cooled, diesel driven, single cylinder, 10 horsepower, portable pump. It’s designed for fire fighting and dewatering The pump is designed to provide 100 GPM at 83 PSI while lifting 20 feet. In high lift operations, it will deliver 71 GPM at 62 PSI while lifting 44 feet

P-100 equipment 3 inch suction hose Foot valve and strainer Wye gate 1 1/2 inch fire hose Vari nozzle Exhaust hose 1 1/2 inch Vita motivator

Portable electrical submersible pump Either a 3 phase AC or a DC motor directly connected to a small, high speed, water cooled centrifugal pump Designed to dewater compartments not served by installed drainage systems Designed to pump cool fresh water / sea water DFM, JP-5, heavy oil, and Navy distillate can be pumped safely. Refer to owners manual for pumping / cool down times

Sub pump capacities 200 GPM at 50 foot static head Maximum suction lift of 20 feet Pumps may be used in tandem to reduce the risk of pump damage and to increase suction lift Energize lowest pump first

Sub pump safety precautions Operator must wear 7500 volt gloves when energizing pump. Use the double braided nylon rope to raise and lower the pump. NEVER use the electical cord!! The pump can be operated safely with personnel in the space. 3 things must happen for electric shock to occur: Motor must ground out, ground wire must be severed, personnel must physically touch the pump

Sub pump safety precautions (cont.) Keep discharge hose free of kinks and sharp bends that will restrict flow. Back pressure will rupture motor seals. Always use strainer and keep it clear of debris. Keep suction lift and discharge head as low as possible. Keep the suction end of the pump in water while the pump is operating.

Portable eductors Used for dewatering operations which involve petroleum products or any type of fuel

2 types of eductors Peri jet 1 1/2 x 2 1/2 single jet (s-type) Both are actuated through a fire hose by firemain pressure or from the discharge a P-100 pump.

Eductors (cont.) Rule of thumb: The amount of water you put into it is what you’ll pump out of the space. Example Water inlet to eductor is 100 GPM Water removed from space is 100 GPM Total discharge is 200 GPM

Review and summary Types of drainage Overboard discharge connections Main drainage Secondary drainage Plumbing and deck drains Overboard discharge connections Drainage of magazines

Review and summary (cont.) Emergency drainage equipment Portable P-100 pump Portable electric submersible pump Portable eductors Peri jet S-type

THE END!!!