Operational and Technical Requirements Rob Connatser Chief Instrument Project Engineer www.europeanspallationsource.se November 2014.

Slides:



Advertisements
Similar presentations
ElectroMagnetic Compatibility in Cable Tray Systems
Advertisements

Cabling system components
Cable Management.
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
BS7671 Formula and Tips.
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
Types of Exposure Devices
EE4503 Electrical Systems Design
M.PEGORARO Grounding Workshop 24th Jan 08 DT GROUNDING & SHIELDING Presented by A. BENVENUTI.
NSS Requirements Review: Labs and Workshops Michelle Everett Lab Coordinator Scientific Activities Division November 12,
NSS Requirements Review: Utilities Michelle Everett Lab Coordinator Scientific Activities Division November 12, 2014.
LECC V. Bobillier1 Overview of LHCb Electronics installation aspects V. Bobillier; L. Roy; J. Christiansen CERN - LHCb.
Instrument Space Requirements Rob Connatser Chief Instrument Project Engineer November 2014.
Jo Beth Folger MMF Site and October 14, Conventional Facilities – MMF Presentation Outline Facility Design.
Electricity How is it made?.
Ministry of Electricity & Energy Egyptian Electricity Holding Company
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
HL-LHC Standards and Best Practices Workshop (11-13 June 2014)
Experimental Area Meeting V. Bobillier1 Good connection to earth (in many points) of every metallic parts to be installed in the cavern is very.
Reproduction interdite © ALMA EUROPEAN CONSORTIUM Reproduction forbidden Design, Manufacture, Transport and Integration in Chile of ALMA Antennas Page.
ESS | Power System | | Frithiof Jensen ESS Power System Ion Source, Front-end.
Tom Kader Chief Electrical Inspector Spaces About Electrical Equipment Sufficient access and working space shall be provided and maintained about.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
MINIMUM ACCEPTABLE LEVELS OF SAFETY & RELIABILITY
Electrical Installation 2
IEEE Wind Farm Collector System Grounding for Personal Safety Summary of Topics.
DMC Calibration Klaus NeumannProduct Manager. Page 2 DMC - Camera Head Production  Raw Die   Pan CCD   Certification - Burn In & Test Flight  
Integrated Grounding, Equipotential Bonding and Lightning Protection in Smart Grids and Smart Buildings – A Multi-Faced Approach Ladies and gentlemen,
IMPACTS OF INSTALLING THE REFERENCE MAGNET PLACEMENT IN B december 2014 Fulvio Boattini & Natacha Lopez Hernandez.
Reproduction interdite © ALMA EUROPEAN CONSORTIUM Reproduction forbidden Design, Manufacture, Transport and Integration in Chile of ALMA Antennas Page.
IFE Plant Structural Concepts Including Shielding and Optical Stability Requirements Thomas Kozub, Charles Gentile, Irving Zatz - PPPL.
Schedule and Work We are moving into a very intensive 4 months with a lot of work to be carried out Electrical services to the devices – after the South.
Magnetic Mitigation - Contents l Magnetic Mitigation General l West Wall Compressors l Rack Room 2 l Magnetic Shielding Yoke Jason Tarrant – Integration.
Typical Telecommunications Network
Etienne CARLIER, LBDS Audit, 28/01/2008 LBDS Environmental Aspects EMC, radiation, UPS… Etienne CARLIER AB/BT/EC.
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
CABLING SYSTEM PROTECTION. Screening/Shielding  1 In the Signamax Cabling System for the efficient screening of the telecommunications systems, the screen.
Plan for test station Marta Bajko For the Technical Review of FReSCa2 June 2015 Saclay Paris.
Contents Jason Tarrant STFC Aim of Presentation to show: l Problem of compressors located at south shield wall l Description of compressor layout and services.
Electrical Engineering for NSS - Status and Planning- Thomas Gahl Electrical Engineering Group Leader February 26, 2014.
CMTF GROUNDING FOR PIP-II K. Carlson PXIE Electrical Coordination Meeting December 19 th, 2013.
ESS Grounding System Concept Fundamentals and Requirements
Design considerations for the FCC electrical network architecture FCC week 2016, Rome, April 2016 Davide Bozzini - CERN/EN/EL With the contribution.
Developing Cabling Module Situation at August 2006 Vello Vanem.
EMC issues for cabling and racks layout design. (Belle II – Grounding) F.Arteche.
COOLING & VENTILATION PLANTS M. Nonis – CERN EN Department / CV Group Annual Meeting of the FCC study – Rome 14 th April 2016.
IEEE NPEC SC2 Equipment Qualification Electromagnetic Compatibility Compliance Type Test-Design Considerations- Installation and Mitigation Standard/Guidance.
Graz University of Technology May 11th – 12th Maribor, Slovenia
NONINCENDIVE INSTALLATIONS FOR CLASS I DIV 2 AREAS
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
St. George Infrastructure
UNIVERSAL CURRENT SENSORS
Leakage control in transmission pipelines
Solar Probe Plus FIELDS Main Electronics Package iPER EMC Feb 2, 2017
SR1 cleanroom extension
NORTH TRUNK SEWER REPLACEMENT PROJECT
Design of Electric Power Systems and Utilities
Conductors and Cables 2017 NEC
ANNEX E PRESENTER WINSTON THOMAS
Engineering Project Cable Management.
EET 323 – Electrical System Design Lecture 9: Grounding
Incompatibility between MV Switchgear conforming TO the international standards and their use in DNO’s substations M. Arens – Y Tits – Belgium – Session.
1-2 Grounding Principles and CF Infrastructure in Instruments Halls
Primary Spectrometer & Sample Environment
IKON 15 Talal Osman & Iain Sutton
STUB configuration Mats Pålsson
Rack Placement Chopper Workshop
North Carolina Department of Insurance Office of State Fire Marshal
State Electrical Division North Carolina Department of Insurance
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

Operational and Technical Requirements Rob Connatser Chief Instrument Project Engineer November 2014

Overview Environmental Electrical/EMF/Harmonics/Grounding/distances Mag field Vibration 2

Environmental Requirements Objectives and Principals Alignment of neutron optics and associated equipment is sensitive to extreme changes in temperature. During the installation phases, this equipment will be exposed to the building environment. For optimal performance and to minimize technical issues, technical equipment and electronics need to be in a well regulated environment. 3

Environmental Requirements 22 C with daily variation of +/-1 degree and seasonal of +/- 2 degrees (in D01, D03, E01, and E02). (i.e. Experiment halls and guide hall) The humidity in D01, D03, E01, and E02 shall be % RH. 4

EMC Requirements All power cables routed in the halls, in the gallery level 090 and in the culvert between E03 and D03 shall be low emitting concerning EMI. This can be done either by using shielded cables or use closed metallic cable trunks (no open “ladders“). All signal cables routed in the halls, in the gallery level 090 and in the culvert shall be installed in closed metallic cable trunks (no open “ladders“). Cables in all installations shall be grouped according to their EMC emittance and susceptibility. Each group shall be installed in a separate cable trunk. There shall be no HV power cable installed (for feeding the substations) in the halls, in the gallery level 090 and in the culvert. 5

EMC Requirements, continued To reduce impact on instrument system CF fixed installations shall not exceed domestic emission limits IEC , but shall also be tolerant to industrial levels, IEC All motors in the cranes and in the rolling doors shall be EM-shielded An exclusion zone of 10m from electrical transformers to labs and instrument equipment shall be met. Power quality delivered to the instruments shall meet EN

Grounding Requirements The cable ducting in gallery level 090 and in hall E01 shall comprise the connection of a power cable and a copper bar of X x Y mm (to be defined later, minimum is the cross section of the power cable conductors) from each instrument to its appropriate power substation. The reinforcement bars in the floor of the halls composing the mesh for the functional grounding shall be connected to each other with a low ohmic impedance of maximum 10 mOhms guaranteed over a period of 40 years preferably by welding. The reinforcement of the piling under the halls shall be connected to the floor reinforcement in the same way to improve the total ground connection. Ground potential for the instruments shall be made accessible by ground bars connecting directly to the floor reinforcement. They shall be installed: – Every 5m along the whole length of the gallery level 090. This may be limited to the area where the gallery is running under hall D01 or D03. – On each column of the wall between hall E01 and E02 7

Magnetic Field The North Sector will be defined as a non-magnetic zone. In a specified (at a later date) area, a significant portion of the floor will be reinforced with non- magnetic materials. No magnetic materials should be utilized within 4m of this instrument zone. The magnetic field strength present in this area shall be limited to a few Gauss. 8

Vibration Buildings D01, D03, E01, and E02 shall meet vibrational requirement of ISO Operating Theatre according to “Generic vibration criteria for vibration- sensitive equipment” DOI: /

10