Transmission System in India

Slides:



Advertisements
Similar presentations
Sistan & Balouchestan Electric Power Distribution Company
Advertisements

Amity University Rajasthan. Transmission Line Def. – A transmission line basically consists of 2 or more parallel conductors used to connect a source.
CHALLENGES IN DEVELOPMENT OF INDIAN POWER SYSTEM Mr. V. Ramakrishna Member (Power System), CEA.
PAKISTAN POWER SECTOR BACK-GROUND, PRESENT SITUATION & FUTURE PLANS.
Brief on HVDC 2015 Brief on HVDC 2015
Generation Peak Demand : 132 GW Growth Rate: 9 – 10 % (per annum) India - Present Power Scenario Total Installed Capacity – GW (As on )
Arrowhead  Weston Transmission Line Project Dave Van House Minnesota Power.
NORTHERN REGIONAL GRID SYSTEM CONTINGECY AND RESTORATION.
System Strength Discussion
Madras Chamber of Commerce & Industry & India Energy Forum Optimizing Transmission Sunil Varma Marri Head-Energy Practice Chennai 5 th September 2014.
Technical Advisory Committee December 6, 2010 Summary of the CREZ Reactive Study Warren Lasher Manager, Long-Term Planning and Policy.
Supergrid Modelling for the Indian Subcontinent Farhan Beg Global Energy Network Institute With Inputs from Mr. Peter Meissen and Mr. Paul Michael Dekker.
Plant Utility System (TKK-2210)
© ABB Group August 7, 2015 | Slide 1 Variable Shunt Reactors Optimize Transmission Systems Dr. Claes Bengtsson, Global Product Manager, Reactors. PowerGen.
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
System Operator Conference Simulator Drill Orientation 2014 System Operator Conferences Charlotte NC & Franklin TN SERC/SOS Facilitator Team.
The SEC Power Forum Wolfgang Braun CEO Energy Transmission Middle East, SIEMENS Session IV: Opportunities in Transmission & Distribution Related Industries.
BRIEF ON THE REPORT OF CIGRE WG B4-45 –
Year 2006 Report “Better” Managed and Controlled Transmission Grids using Advanced Technological Concepts Aty Edris EPRI Power Delivery & Markets
Review of progress and future work SQSS Sub Group 2 August 2006 DTI / OFGEM OFFSHORE TRANSMISSION EXPERTS GROUP.
TRANSMISSION SYSTEM KERALA K ASOKAN DIRECTOR INSTITUTE FOR SUSTAINABLE DEVELOPMENT AND ENERGY STUDIES (InSDES)
THE TRES AMIGAS SUPERSTATION Southwest Renewable Energy Conference Santa Fe, NMSeptember 16 th 2010 UNITING THE NATION’S ELECTRIC POWER GRID.
INDIAN POWER SECTOR. ADMINISTRATION AND MANAGEMENT As per Constitution of India, Electricity comes under concurrent list i.e. the development and management.
ELG4125 Transmission and Distribution Systems
Grid Integration of Renewable in India - Challenges and Policy Responses Sanjay Garg General Manager General Manager PGCIL/ Ministry of Power.
INDIAN POWER SECTOR. Presentation Contents: Power Sector Structure in India Transmission Planning Criteria RLDC ’ s Management System Restoration Procedures.
Performance Equations and Parameters of Transmission Lines
 POWERGID – PERSPECTIVE PLAN. POWERGRID – Introduction  POWERGRID, the Central Transmission Utility, is responsible for  Establishment and Operation.
Electricity Generating Authority of Thailand (EGAT) 1 STRUCTURE, STATUS AND CROSS BORDER POWER INTERCONNECTION 0F THAILAND b y Mr. Prutichai Chonglertvanichkul.
Lecture 1 – Power Quality INTRODUCTION TO POWER QUALITY Power Quality phenomenon-Terms and definitions-Various Power events in power quality - causes for.
Alok Roy. UHV/EHV Level HV/MV Level LV Level The Concept of a power grid.
AFREPREN/FWD Cogen Centre Training Workshop on Cogeneration in Africa
DEVELOPMENT OF SOUTH ASIAN GRID. WHY SOUTH ASIAN GRID ? Optimal Utilization of Natural Resources Opportunity of Energy Trading Economy of Scale Advantage.
1 V.RAMAKRISHNA MEMBER (POWER SYSTEMS) CENTRAL ELECTRICITY AUTHORITY GROWTH OF POWER SYSTEM IN THE COUNTRY AND FUTURE PERSPECTIVE by 28 th APRIL, 2008.
OVERVIEW OF INDIAN POWER SECTOR AND PLAN FOR 12 th / 13 th PLAN.
1 TRANSMISSION SYSTEM OVERVIEW NETWORK OPERATING COMMITTEE April 17, 2007 New Mexico Transmission System Overview.
W E L C O M E Power Grid Corporation of India Limited.
Sanjay Garg General Manager PGCIL/ Ministry of Power
Sterlite Grid Limited Committed to the nation's mission to provide quality power for all.
Transmission Integration of Nuclear 1 Bantamsklip Site November 2009.
EVACUATION STRATEGIES FOR KARWAR ULTRA MEGA THERMAL POWER PROJECT SOUTHERN REGIONAL LOAD DESPATCH CENTRE.
SRLDC WELCOMES SHRI VISHNUVARDHAN REDDY DIRECTOR(F) KPC.
IMPACT OF ABT, NETWORK STRENGTHENING ON GRID OPERATION IN KARNATAKA SOUTHERN REGIONAL LOAD DESPATCH CENTRE POWER GRID CORPORATION OF INDIA LIMITED ADVANTAGE.
Operating the Indian Electricity Grid Challenges and Future Outlook R.P.Singh Chairman and Managing Director Power Grid Corporation of India Limited.
TRANSMISSION CONSTRAINTS KENNETH A. DONOHOO, P.E. Manager of System Planning, Technical Operations
Overall National Grid Development: Constraints & Options
1 AUDITORS. 2 SOUTHERN REGION WESTERN REGION EASTERN REGION NORTHERN REGION NORTH- EASTERN REGION INSTALLED CAPACITY NORTHERN :- 31,230 MW EASTERN :-
NORTHERN REGIONAL LOAD DISPATCH CENTER 1.Revision Of Ceiling Of UI Rates and slope. 2.Revision Of Schedule after a Transmission Constraint is over. 4.RLDC’s.
Southern Regional Power Committee Central Electricity Authority.
Voltage Control Brad Calhoun Consultant, Sr. Trainer Spring 2016.
1 Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors.
HVDC Transmission.
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
Sterlite Grid Limited Sterlite Grid Limited
Introduction to Electric Power System and A. C. Supply
1 3 Earths will be required by 2050.
HVDC LIGHT:- NEW TECHNOLOGY FOR A BETTER ENVIRONMENT
IG BASED WINDFARMS USING STATCOM
REGIONAL GRIDS IN INDIA – QUICK FACTS
IN ADDITION OF UI RATE CORROSPONDING TO FREQUENCY OF 49
SWAMI VIVEKANAND COLLEGE OF ENGINEERING,INDORE(M.P)
POWER SYSTEM PLANNING AND DESIGN. TITLE : DESIGN OF EHV TRANSMISSION LINES & BUNDELED CONDUCTORS IN EHV LINES. PREPARED BY : JOBIN ABRAHAM.
Transmission and Sub-Transmission Network India – Present and Future Rajesh Suri GE (T&D) India Ltd 8 November 2018.
POWER SYSTEM ANALYSIS INTRODUCTION.
Design of Electric Power Systems and Utilities
POWER GRID INTERCONNECTIONS IN CHINA
HVDC Transmission Systems:
CHAPTER – 41 A.C. TRANSMISSION AND DISTRIBUTION
HIGH VOLTAGE ENGINEERING Presented By P.Sindhu Asst.Prof EEE Dept
National Institute of Wind Energy(NIWE)
Presentation transcript:

Transmission System in India Development of 1200kV Transmission System in India V Ramakrishna, Central Electricity Authority Subir Sen, Power Grid Corpn. of India Ltd.

Presentation Flow Overview of Indian Power System Future demand-supply scenario Consideration for high capacity 1200kV transmission corridor development Broad 1200kV AC technical parameters 1200kV UHVAC Test Station Summary

Overview of Indian Power System

Indian Power System - Present Installed Capacity: 147GW Peak Demand : 109 GW Transmission Grid Comprises: 765kV Lines - 1600 ckt. km 400kV Lines - 76,000 ckt. km 220/132kV Lines - 115,000 ckt. km HVDC bipoles - 3 nos. HVDC back-to-back - 7 nos. FSC – 18 nos. TCSC – 6 nos. NER, ER, NR & WR operating as single grid of 100 GW SR Grid – 40 GW Inter-regional capacity : 18,700 MW

National Grid - At Present Eastern Region Western Region Southern Region Northern Region North-eastern Region 6330 MW 1260 MW 2990MW 3630 MW 1720 MW 2120 MW Inter-regional Capacity - 18,700MW (incl. 132kV links)

National Grid - Present Inter-regional capacity : 18,700MW National Grid - Present

Inter-regional Capacity - 38,700MW (incl. 132kV links) National Grid by 2012 Eastern Region Western Region Southern Region Northern Region North-eastern Region 12130 MW 2860 MW 6490 MW 3630 MW 2720 MW 4220 MW 6000 MW Inter-regional Capacity - 38,700MW (incl. 132kV links)

National Grid – A Continuing Process National Grid by 2012 Inter-regional capacity : 38,700 MW National Grid – A Continuing Process

Future Requirement

Growth of Installed Capacity/Demand

Energy Resource Map Hydro potential in NER and upper part of NR Coal reserves mainly in ER Ensure optimal utilisation of resources – strong National Grid is in place and capacity is being enhanced continuously

Likely Capacity addition in next 15 years Peak Demand : 450GW Inst. Capacity : 600GW Additional capacity addition of about 390GW would be required Load centre based, 90

Future Demand-Supply Scenario Region Installed Capacity (GW) Availability (GW) Peak Demand (GW) Surplus(+) /Deficit (-) GW Northern 145 110 140 (-) 30 Western 135 100 130 (- ) 30 Southern Eastern 105 80 40 (+) 40 North-eastern 60 10 (+) 50 Total 600 450  

Likely power transfer requirement between various regions in next 15 years North-eastern Region Northern Region 27 GW 15 GW 10,000MW 18 GW 12 GW 23 GW IC = 145 GW Despatch = 110 GW Demand = 140 GW Deficit = 30 GW Western Region IC = 135 GW Despatch = 100 GW Demand = 130 GW Southern Region Eastern Region IC = 106 GW Despatch = 80 GW Demand = 40 GW Surplus = 40 GW Deficit = 30,GW IC = 80 GW Despatch = 60 GW Demand = 10 GW Surplus = 50 GW 20 GW ALL INDIA IC = 600 GW Demand = 450 GW

Power Transfer Requirement by 2014-15 Jharkhand-8000MW 3,000MW 12,500MW NER NR ER IC = 74,000MW Demand = 56,500MW Deficit = -19,000MW 4,000MW IC = 6,300MW Demand = 3,000MW Surplus = 2,500MW 3,000MW 6,000MW IC = 63,000MW Demand = 23,000MW Surplus = 18,000MW 1,000MW 7,500MW 5,000MW 1,000MW Sterlite:2400MW 17,000MW Monet:900MW Jindal:1320MW Malaxmi:956MW Visa:500 MW KVK:560MW Lanco:693MW WR IC = 85,000MW Demand = 55,000MW Deficit = -6,000MW 4,000MW Orissa-7330MW 10,000MW 2,500MW 1,000MW 4,000MW 1,000MW 1,000MW Chattishgarh:8000MW Existing/Planned IC = 68,000MW Demand = 49,000MW Surplus = 6,000MW Being Planned SR A.P. : 12000MW Tamil Nadu : 7000MW

Transmission Development

Consideration for Future Transmission Development 1. Requirement of Bulk power transfer over Long Distances from resources rich area/region to load centers 2. ROW constraints, limited Transmission corridors available 3. High Short Circuit Levels 4. Variation and regulation in Power Flow

Power Flow Pattern Variation in generation High hydro in monsoon and summer In winter only during peak hours Power flow variations due to commercial/operational reasons Variation in load demand Daily basis (peak and off-peak) Seasonal variations Due to above, each transmission corridor has varied power flow pattern ranging from high to low loading, results into wide variation in voltages

Present Technologies & its Limitations 400 kV Twin Moose - upto 600-700MW 400 kV Quad Moose - Upto 1200-1500MW 765 kV Line - upto 2000/3000 MW Sipat – Seoni first 765 kV line operated at rated voltage HVDC bipole - + 500 kV upto 2000-2500MW

Need 1. Development of hybrid transmission system for maintaining critical parameters as well as regulations of power flow 2. Increase in MW flow per metre of ROW 3. Controlling high Short Circuit Levels

Transmission System through Narrow Area Eastern Region/ Western Region/ Southern Region North-eastern Region 50 GW Requirement of Power Flow between NER & ER/WR/NR: 50 GW Required Transmission Capacity : 57.5 GW (15% redundancy) Existing & planned Capacity : 9.5 GW Additional Trans. Capacity to be planned : 48 GW Options : 1. +800kV HVDC : 8nos. 2. +800kV HVDC : 5nos.; 765kV EHVAC : 6nos. 3. +800kV HVDC : 4nos.; 1200kV UHVAC : 2nos. Selection of Next Level Transmission Voltage i.e. 1200kV UHVAC in view of : Loading lines upto Thermal Capacity(10000 MW) compared to SIL(6000 MW) Saving Right of Way

Transmission System through Narrow Area

1200kV AC Transmission System – Considerations In Chhattisgarh State, projects with total capacity of about 35,000 MW have been planned to be commissioned progressively in the next 4-5 years. Power from these projects is to be transferred to bulk load centres in the Western and Northern Regions. To facilitate exchange of such quantum of power, strengthening of East-West and East-North transmission corridors in WR is required. Further, it has been observed that growth of interconnection at 400kV/765kV level would result into increase in short circuit level at various EHV substations beyond the limit (40kA)

1200kV AC Transmission System – A Case Study Considering quantum of power transfer on long-term as well as to address high short circuit level, a high capacity 1200kV transmission corridor i.e, Raipur-Wardha and Wardha- Aurangabad is proposed Projects are being developed in a phased manner with less power transfer requirement initially, it is proposed that this high capacity East-West transmission corridor shall be operated initially at 400kV level. Accordingly, with suitable design 1200kV S/c line is initially proposed to be operated as a 400kV (quad) D/c line so that system redundancy can be maintained. Subsequently, with the increase in power transfer requirement through this corridor, line shall be operated at 1200kV level

Proposed 1200kV AC Transmission Corridor

Line Parameters Line parameters of 1200kV/765kV/400kV Transmission System   1200 kV 765kV 400kV Nominal Voltage (kV) 1150 765 400 Highest voltage(kV) 1200 800 420 Resistance (pu/km) 4.338 x10-7 1.951x10-6 1.862x10-5 Reactance (pu/km) 1.772 x10-5 4.475x10-5 2.075x10-4 Susceptance (pu/km) 6.447 x10-2 2.4x10-2 5.55x10-3 Surge Impedance Loading (MW) 6030 2315 515 Base kV :1200kV/765kV/400kV; Base MVA :100 MVA

Large Variation of Reactive MVAR Reactance of 1200kV AC line is 1/3rd of 765kV system Susceptance (charging capacitance) is 2½ times more of 765kV line Wide difference in the electrical parameters shall lead to the problems of reactive power (VAR) balance Huge Reactive Power Generation by 1200kV line about 6 MVAR/km These uncompensated lines shall generate huge capacitive charging reactive power for which static reactive compensation devices like shunt reactor, bus reactor of adequate size is to be provided

1200kV Wardha – Aurangabad line reactive power characteristic

Reactive Power Management of 1200kV Lines Maintaining constant/optimum level of power flow on the 1200kV AC system under different operating conditions To control power through 1200kV AC system a layered system of 1200kV AC transmission corridor along with 800kV, 6000MW HVDC system shall be developed Control and regulation mechanisms Exchange of power between 1200kV AC system and lower level network (765kV/400kV) through HVDC back-to back links at strategic locations Control of power flow on the 800kV HVDC bipole lines Dynamic Reactive Power Management through Series and Shunt Compensation

Maintaining Uniform power flow through 1200kV System Layered high capacity transmission network with control & regulation features 800kV HVDC 765kV EHVAC System 400kV EHVAC System ~ 220kV/132kV SYSTEM 500kV HVDC 1200kV UHVAC System

Increase in Short Circuit Level Indian system is designed for max. short circuit level – 40kA After 30 years of operation, it is expected that fault level at various S/s shall increase beyond its limit in next 4-5 years Most of these s/s are either major pooling stations or high capacity trans. Interconnections with major generation complex/substations Development of 1200kV transmission corridors shall facilitate in controlling high short circuit level, although other mitigating measures are also being taken

Broad Parameters

Other 1200kV Parameters Based on the preliminary studies, broad parameters determined as under : Sl No. Description/Parameters Unit Value 1 System Nominal Operating parameters (i) Phase – Phase kV 1150 (ii) Frequency Hz 50 (iii) Number of phases Nos 3 2 System Maximum Voltage (Ph-Ph) 1200 System Insulation Levels Full wave impulse withstand voltage (1.2/50 microsec.) 2400 Switching impulse withstand voltage (250/2500 micro sec.) dry and wet 1800 One minute power frequency dry and wet withstand voltage (rms)

Other 1200kV Parameters …contd Sl No. Description/Parameters Unit Value 4 Short Circuit Level kA 50 5 Corona extinction voltage kV 762 6 Max. radio interference voltage for frequency between 0.5 MHz and 2 MHz at 762 kV rms for 1200kV system Micro V 1000 7 Creepage Distance mm/kV 25 i.e. (Total 30000 for 1200kV system). 8 Bus Bars/Equipment Interconnections (i) Tubular Bus/Connections Twin Al. 4” IPS tubes with 450mm/550mm spacing. (ii) Height m 18.00 (iii) Strung Bus/Equipment Connections Conductor Bundle Octa Bundle Bersimis with 450 mm sub conductor spacing

Other 1200kV Parameters …contd Sl No. Description/Parameters Unit Value 9 Clearances (i) Minimum Phase to Phase Clearance m 12.30 (ii) Minimum Phase to Earth Clearance 8.30 (iii) Sectional clearances 10.5 (iv) Phase to Phase distance (Pie Structure) 27.00 10 System neutral earthing - Effectively earthed

Field Studies on 1200kV AC System POWERGRID has undertaken various studies and tests to determine the configuration of its 1200kV transmission lines, like corona cage studies air gap insulation studies tests for voltage distribution on the insulator string long term studies on test line for measurement of AN, RIV & voltage gradient measurement at ground level

1200kV Test Station

Establishment of 1200 kV AC Test Station To develop 1200kV technology indigenously, POWERGRID in collaboration with manufacturers establishing a 1200kV AC Test Station at Bina This endeavour shall benefit the Indian Power sector and manufacturers for Optimisation of transmission cost Ease in O&M

1200KV UHVAC Test Station A 3 phase 1200kV Test Lines (S/C & D/C) of about 1 km length are being constructed. Salient features: Variable Phase to Phase Spacings Variable Ground Clearance Upto 12 sub-conductor bundle Variable Bundle diameter A 1200kV 3-phase test bay is being constructed to charge these Test Lines

1200KV UHVAC Test Station Test station shall be fully equipped with testing instrument for field testing Extensive developmental tests shall be conducted on the test line as well as on s/s equipments installed in the Test Bay jointly by Utilities, Manufacturer & Research Institute

Summary

Summary To meet growing power transfer requirement and environmental friendly development, 1200kV AC system along with 800kV, 6000MW HVDC system has been planned in the Indian Power System Reactive power management for 1200kV AC system is an important aspect which require detail analysis for suitable static and dynamic reactive compensation Results of some of preliminary studies discussed More studies and field tests are under process to finalise all the critical electrical parameters Establishment of a 1200kV AC Test Station at Bina is under progress

Thank You