CVFD Training – Ventilation Practices

Slides:



Advertisements
Similar presentations
Fire Behaviour Ventilation. Aim To provide students with information to give them an understanding of the behaviour of fire.
Advertisements

Flashover Recognition and Survival
TRUCK COMPANY OPS Truck company operations are tasks that support the fire attack. Often called Support Functions The engine companies put the fire out.
Valley City State University | Facilities Services
Fire Safety. The Basics Smoke Alarms Escape Plans Practice Preparation Knowledge.
Chapter 4 Fire-Related Chemistry and Physics
Fire Triangle FuelHeat Fire! Oxygen 1 st Stage: Incipient 1 st stage No visible flame Little smoke Is not yet self-sustaining According to the National.
Basic Fire Attack Dallas Fire Rescue Explorers. Basic Fire Attack Overview of Fire Attack Overview of Fire Attack Rescue Activities Rescue Activities.
FVCC Fire Rescue Ventilation Part A Truck Company Operations Review of Ventilation Principles & Practices.
Chapter 11 Lesson Goal After completing this lesson, the student shall be able to identify reasons and needs for various types of ventilation within a.
Ventilation Objectives The student will: Understand the importance of ventilation. Be able to identify when and where to ventilate. Understand the dangers.
Fire safety is an important business. You need to take proper precaution in order to prevent a fire. Yes, fire may be inevitable but if prepared, you can.
Fire Suppression Techniques IFSTA Chapter 14
7/2/2015Dixon High School Fire Department1 The Recruit will also practice and master certain skills and will be tested on these skills. At the end of each.
CVFD Training – Ladder Practices SFFMA Training Objectives –
Instructor: Dan Braitsch
CVFD Training – Rescue Operations SFFMA Training Objectives: –
EGRESS AND FIRE PROTECTION
Fire Safety.
13 Search and Rescue. 2 Objectives (1 of 2) Define search and rescue. Describe the importance of scene size- up in search and rescue. Describe search.
TS 10–1 VENTILATION The systematic removal of heated air, smoke, and gases from a structure and replacement with cooler, cleaner air.
FVCC Fire Rescue Ventilation Part B. Types of Ventilation Horizontal Ventilation: Use of doors and windows to ventilate across the floor of a building.
1402 Hybrid Firefighter II 6th Edition Chapter 4 — Building Construction South Carolina Fire Academy.
14 Ventilation.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
14 Ventilation. 2 Objectives Define ventilation as it relates to fire suppression activities. List the effects of properly performed ventilation on fire.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
FIRE BEHAVIOR ILLINOIS OSFM FIREFIGHTER III. TERMS Heat Measurement –BTU Amount of heat required to raise the temperature of 1 pound of water 1 degree.
FIRE BEHAVIOR State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Lesson Goal After completing this lesson, the student shall be able to identify indicators of an incendiary fire and protect and preserve evidence after.
MODULE 6: PRIVATE DWELLING SIMULATIONS. OBJECTIVES Module 6 Overview Identify the unique construction factors of single-family dwellings. Recognize the.
MODULE 6: PRIVATE DWELLING SIMULATIONS. OBJECTIVES Module 6 Identify the unique construction factors of single-family dwellings. Recognize the basic problems.
1 © 2009 Delmar, Cengage Learning Special Concerns in Fire Fighting Chapter 6 Page 133.
FIRE PREVENTION. Fire Of the many hazards on site or at work, fires are the worst kind. They do a great deal of damage every year.  All fires, however.
Search & Rescue Ins and Outs Presented for use by Emory Arnold For.
Search and Rescue.
Structure Fire Ventilation Making firefighting easier.
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Harpeth Health Science Program Kelly Hutchison R.N. Fire can occur anywhere at anytime.
Tyson Burt Mathieu Gagnon
14 Ventilation. 2 Objectives (1 of 3) Define ventilation as it relates to fire suppression activities. List the effects of properly performed ventilation.
Part C: Class D Fires and Tactical Considerations.
2/3/2016Dixon High School Fire Department Rescue References IFSTA Essentials of Fire Fighting Fifth Edition IFSTA Essentials of Fire Fighting Fifth Edition.
1. 2  Dispatch information  Day of week  Time of day  Pre-incident survey  Observations  Building construction, layout  Bystanders.
Confined Spaces. Definition: Are large enough that an employee can bodily enter them Are not designed for continuous occupancy. Have limited or restricted.
Fireground Operations: Structure Fires Union County SOG 3.16.
13 Search and Rescue.
Flammable Liquids Directorate of Training and Education
Fire Ground Roles & Responsibilities On scene reports & Truck and seat assignments.
Compartment Fire Dynamics Ventilation Controlled Compartment Fires
Essentials of Fire Fighting 6 th Edition Firefighter I Chapter 13 — Tactical Ventilation.
MGT 401 Week 4 Quiz Check this A+ tutorial guideline at 1. Question : An area large enough.
Fire Behavior & Extinguisher Use.
Learning Objective 7 Describe the types of vertical ventilation.
Ventilation (Fire Fighter I)
Fire Suppression (Fire Fighter II)
Fire Extinguisher Training
Essentials of Fire Fighting Chapter 4 — Building Construction
CHAPTER 15 Ventilation: Tactical Priorities
FVCC Fire Rescue Fire Control.
Fire Safety/Extinguisher Use
NOVA MANUAL TRAINING TOWNHOUSE June 2009
14 Ventilation.
Essentials of Fire Fighting
Enclosure Fire Dynamics
Basics of Chemistry and Firefighting
Essentials of Fire Fighting, 5th Edition
Presentation transcript:

CVFD Training – Ventilation Practices SFFMA Training Objectives: 8-01.01 – 8-01.04

Life Safety Reasons for Fireground Ventilation Increases firefighter safety by reducing interior temperature, increasing visibility Reduces chance of firefighters receiving steam burns when water applied (Continued) Firefighter I

Life Safety Reasons for Fireground Ventilation Reduces likelihood of sudden, hazardous changes in fire behavior Simplifies, expedites search and rescue operations by removing smoke, gases that endanger trapped/unconscious occupants Firefighter I

Fire Attack and Extinguishment Reasons for Fireground Ventilation Permits firefighters to more rapidly locate fire, proceed with extinguishment When ventilation opening made in upper portion of building, chimney effect occurs (Continued) Firefighter I

Fire Attack and Extinguishment Reasons for Fireground Ventilation Firefighter I

Fire Spread Control Reasons for Fireground Ventilation Effective ventilation Reduces rate of smoke layer development Can reverse process of smoke layer development Reduces rate at which fire will spread over area (Continued) Firefighter I

Fire Spread Control Reasons for Fireground Ventilation Even with proper ventilation, if fire not extinguished soon after ventilation completed, increased supply of fresh air will feed fire Ventilation should occur only after hoseline crews ready to move in, attack (Continued) Firefighter I

Fire Spread Control Reasons for Fireground Ventilation Firefighter I

Reduction of Flashover Potential Reasons for Fireground Ventilation Transition between growth, fully developed As unventilated interior fire burns and flames, smoke, and gases extend, heat radiates back down until combustibles heated to ignition temperatures Once ignition temperatures reached, contents will ignite (Continued) Firefighter I

Reduction of Flashover Potential Reasons for Fireground Ventilation Ventilation helps prevent flashover from occurring Opening single door or window may not remove enough smoke, heat to prevent flashover (Continued) Firefighter I

Reduction of Flashover Potential Reasons for Fireground Ventilation If fire producing significant amount of smoke and heat but limited by available oxygen, ventilating room may cause rapid ignition of hot fire gases in upper layer, initiating flashover Firefighter I

Reduction of Backdraft Potential Reasons for Fireground Ventilation When fire confined in compartment and does not break window or burn through to outside, will reduce oxygen level until flaming combustion no longer possible If air supply introduced, backdraft occurs (Continued) Firefighter I

Reduction of Backdraft Potential Reasons for Fireground Ventilation To prevent backdraft conditions, carefully controlled ventilation must be provided Vertical ventilation often safest for this Signs of potential backdraft Firefighter I

DISCUSSION QUESTION Do you know of any examples of fires in which backdraft occurred? Firefighter I

Property Conservation Reasons for Fireground Ventilation Rapid extinguishment reduces water, heat, smoke damage Timely, effective ventilation helps extinguish interior fires faster Smoke may be removed from buildings by natural or mechanical means (Continued) Firefighter I

Property Conservation Reasons for Fireground Ventilation When smoke, gases, heat removed from burning building, fire can be confined If sufficient personnel, effective salvage operations can be initiated outside immediate fire area during fire control operations Firefighter I

Considerations Affecting Ventilation Is there need at this time? Where is ventilation needed? What type should be used? Do fire, structural conditions allow for safe roof operations? Are Vent Group personnel trained, equipped to ventilate building? Firefighter I

Life Safety Hazards First consideration is safety of firefighters and building occupants Life hazards in burning building generally lower if occupants awake If occupants asleep, a number of possibilities must be considered (Continued) Firefighter I

DISCUSSION QUESTION What are some ways to determine if there are occupants still inside the building? Firefighter I

Life Safety Hazards Depending on fire conditions, ventilation may be needed before search and rescue begins Hazards from accumulation of smoke, gases in building Firefighter I

Visible Smoke Conditions Smoke accompanies most ordinary forms of combustion Density of smoke increases with amount of suspended particles Smoke conditions vary according to how burning has progressed Firefighter I

The Building Involved In addition to location of fire within building, building’s age, type, design must be considered Other factors include number and size of wall openings, type of roof construction, etc. (Continued) Firefighter I

The Building Involved If results of preincident planning have been documented and are available to officers on fireground, may provide valuable information affecting ventilation (Continued) Firefighter I

The Building Involved High-rise buildings have extra considerations Firefighter I

Basements and Windowless Buildings Without effective ventilation, access into basement is difficult because firefighters must descend through worst heat, smoke to get to seat Several features impede attempts at natural ventilation (Continued) Firefighter I

Basements and Windowless Buildings Many buildings have windowless wall areas In some cases, creating openings needed may delay operation considerably Ventilating considerations (Continued) Firefighter I

Basements and Windowless Buildings Firefighter I

Location and Extent of Fire First-arriving units must determine size, extent of fire as well as location Severity, extent of fire depend on number of factors (Continued) Firefighter I

Location and Extent of Fire Phase to which fire has progressed is a primary consideration in selecting ventilation procedures Ways that vertical fire extension occurs Firefighter I

Selecting Place to Ventilate Ideal situation one with as much information as possible about fire, building, occupancy Many factors have bearing on where to ventilate (Continued) Firefighter I

Selecting Place to Ventilate Many considerations before ventilating building Firefighter I

Horizontal Ventilation Venting of heat, smoke, and gases through horizontal openings Certain structures lend themselves to this application (Continued) Firefighter I

Horizontal Ventilation Many aspects of vertical ventilation apply to horizontal ventilation; different procedure must be followed Besides direct flame contact, horizontal extension can occur in several ways Firefighter I

Horizontal Ventilation Considerations — Weather Must always be considered Wind has most potential influence; can aid or hinder horizontal ventilation Wind direction Setting up natural horizontal ventilation Firefighter I

DISCUSSION QUESTION What are some other weather conditions that should be considered before performing horizontal ventilation? Firefighter I

Horizontal Ventilation Considerations — Exposures Internal — Include building occupants, any uninvolved rooms/portions of building External (Continued) Firefighter I

Horizontal Ventilation Considerations — Exposures Because horizontal ventilation does not release heat and smoke directly above fire Routing necessary Routes may be same needed for evacuation Effects on rescue, exit must be considered (Continued) Firefighter I

Horizontal Ventilation Considerations — Exposures Because heat, smoke, fire can be discharged below highest point of building Also danger that rising gases will ignite portions of building above exit point Rising gases may be drawn into windows/ attic vents above exit point (Continued) Firefighter I

Horizontal Ventilation Considerations — Exposures Because heat, smoke, fire can be discharged below highest point of building (cont.) They may ignite eaves of building/adjacent structures Unless for rescue, building should NOT be ventilated until charged hoselines in place at entry point Charged hoselines should be ready at intermediate point where fire might spread (Continued) Firefighter I

Daylight Basement Ventilation Considerations Daylight basements Occur in homes built on slopes Finished basements with large exterior windows, possibly exterior door(s) Easier to ventilate than conventional Opening door, breaking windows, etc. provides adequate ventilation Firefighter I

Precautions Against Upsetting Horizontal Ventilation Opening a door/window on windward side of building prior to ventilation exit opening on leeward size may pressurize building, intensify fire, cause fire spread (Continued) Firefighter I

Precautions Against Upsetting Horizontal Ventilation Take advantage of air currents If established currents blocked, positive effects may be reduced/eliminated Firefighter I

Advantages of Forced Ventilation Supplements, enhances natural ventilation Ensures more control of air flow Speeds removal of contaminants Reduces smoke damage Promotes good public relations Firefighter I