DESIGN OF A TESTING MACHINE FOR MICRO-DEVICES Follow up to Clément Gabry’s master thesis on Structural Resistance of Silicon Membranes 1 12/10/2014CERN.

Slides:



Advertisements
Similar presentations
Machine Condition Monitoring
Advertisements

6-7 July 20051B. C. Bigelow - UM Physics Finite element analysis of DECam May 11 C1 corrector lens – gravity and thermal load cases Bruce C. Bigelow, Physics.
Industrial Electrical Engineering and Automation Actuators Linear movement and vibration.
Set-Block Design Issues August 12 th, Frederickson Skin and Spar MBU Background  Set blocks are used to verify the distance between the bed of.
2007 FIRST Robotics Conference Pneumatic Power Presented by: Raul Olivera, WildStang
Efforts By : Ankit Puri Project Supervisor : Fangpo He.
Flexures for Optics. Outline Brief overviews of micro flexures Focus on macro flexures in this tutorial Beam bending Symmetry -> precision Degree of freedom.
The Dynamics of Microscopic Filaments Christopher Lowe Marco Cosentino-Lagomarsini (AMOLF)
A change in the shape of a component carrying a load, will have the effect of increasing the stress, nearly always at a concave corner. The degree of concentration.
1 Grating Mount Requirements Weight:< 75 Lbs including grating (43.1 Lbs) Size:Fit within structural envelope. 1.5” for cell behind grating. Alignment:Adjust.
Precision Engineering used in EUVL 03/18/2003 ME250 Prof. Furman By:  Udayasri Jandhyala  Kanchan Joshi.
March 4, 2005 All rights reserved Torque – Angle in Slip Ring - Non-Contact Rotary Torque Sensor Installation Tips Foot mount torque sensor Driver Load.
Pore Detection in Small Diameter Bores The University of Michigan, Ann Arbor NSF Engineering Research Center for Reconfigurable Manufacturing Systems.
22-Nov-2004 © Renishaw plc Not to be reproduced without written permission from Renishaw Laser & Calibration Products Division Slide 1 Laser.
Mechatronics Linear Motors Advantages : Precise High forces Few parts video Disadvantages : Limited stroke Space occupancy Cost Complex to build/assemble.
MECHANICAL DESIGNS. What is mechanical design? All the mechanical hardware used in the machine is called mechanical design. Precision machines are essential.

Pneumatic Power FRC Conference 4/27/06
“Pinhole Measurement” Approach to K Measurements using Spontaneous Radiation November 14, 2005 J. Welch, R. Bionta, S. Reiche.
Target Specifications & History (to avoid reinventing a broken wheel!) 2 nd December 2009 Chris Booth The University of Sheffield.
Multidisciplinary Engineering Senior Design Project 6218 Soft Tissue “Tensile” Tester Preliminary Design Review 2/24/2006 Project Sponsor: Bausch & Lomb.
Stave Mechanical Studies
STABILIZATION FOR LHC INNER TRIPLETS S. Janssens, K. Artoos, M. Guinchard NOT for Distribution.

DELTA Quadrant Tuning Y. Levashov, E. Reese. 2 Tolerances for prototype quadrant tuning Magnet center deviations from a nominal center line < ± 50  m.
Bridge Modules BKK and BKR
DESIGN OF A TESTING MACHINE FOR MICRO-DEVICES Follow up to Clément Gabry’s master thesis on Structural Resistance of Silicon Membranes 1 12/10/2014CERN.
Pulleys Simple Machines.
SAM PDR1 SAM LGS Mechanical Design A. Montane, A. Tokovinin, H. Ochoa SAM LGS Preliminary Design Review September 2007, La Serena.
Understanding typical users for this instrument Graduate studentGraduate student –not an X-ray expert but wants to make a spatially resolved measurement;
Tomelleri S.r.l. ® Copyright 2007 © ASTRONOMY AND RESEARCH September 19th 2008 VST Meeting1.
EE 5323 – Nonlinear Systems, Spring 2012 MEMS Actuation Basics: Electrostatic Actuation Two basic actuator types: Out of Plane(parallel plate) In Plane.
DBQ support – motorization and performance upgrade Mateusz Sosin EN/MEF-SU.
What is MEMS Technology?. What is MEMS ? What is MEMS ? Micro Electro Mechanical Systems – micro scale dimensions (1mm = 1000 microns) – electrical and.
Engineering Division 1 M321/M331 Mirror Switchyard Design Review Tom Miller
GONIOMETER FOR TEST BEAM MEASUREMENTS Yury Gavrikov (PNPI, Gatchina, Russia) UA9 Collaboration meeting
Control systems KON-C2004 Mechatronics Basics Tapio Lantela, Nov 5th, 2015.
CLIC Module meeting, 22/08/2011 N. Chritin (EN/MME) Cradles design for CLIC module supporting system (EDMS )  General principle  Main inputs an.
LCFI Mechanical room LCFI facilities –Cold survey cryostat and LASS, currently being upgraded –Cold gas test rig –Glue robot All housed in Lab 9 –Temperature.
Engineering 1040: Mechanisms & Electric Circuits Fall 2011
URL: 12-1, Hisakata 2-chome, Tempaku-ku, Nagoya JAPAN (C)2001 Manufacturing Engineering Laboratory,
The MesoMill™ An Off-The-Shelf Small Milling Machine By Roger Cortesi MIT Precision Engineering Research Group.
1 03/21/2006 GLAST CU Beam Test Workshop Scanning Table.
STABILISATION AND PRECISION POINTING QUADRUPOLE MAGNETS IN THE COMPACT LINEAR COLLIDER S. Janssens, P. Fernandez Carmona, K. Artoos, C. Collette, M. Guinchard.
Beam intensity profile measurements with the RHIC (AGS) C-CNI polarimeters. Polarization profile measurements. Polarimeter target mechanisms upgrades.
VEA’s proposal of automated assembly system WP6 meeting, 16/01/14.
Jeff T. Collins Undulator Support/Mover System 20 October 2005 LCLSLCLSLCLSLCLS LCLS Undulator Support/Mover System.
Break Findings. Piston Cylinder Actuators Creates 1-directional motion, returning force is generated with a spring. To meet both resolution and max travel.
ROBOTICS 01PEEQW Basilio Bona DAUIN – Politecnico di Torino.
Hcal Geometry and Assembly Videoconference January 2008, 24th.
Biomechatronic Hand Seminar On
SPS movable table Joanna Swieszek, Kurt Artoos (EN-MME) 14/04/2016.
H. MAINAUD DURAND on behalf of the CLIC active pre-alignment team Status on CLIC pre-alignment studies.
Test on mirror support prototypes M. Lenti. News from MARCON Shipping at CERN of all the mirrors: end of 2010 – beginning of dummy segments ordered.
Page 1 GSI, Hydraulic Actuators for PANDA Target Spectrometer Jost Lühning, GSI Darmstadt Functional Specifications for moving the TS: Two synchronous.
SNS COLLEGE OF ENGINEERING
CMM Coordinate-Measuring Machine
Early Stage Researcher 1.1 Work Package 1
Maximal Permissible Error on the positioning: MPEE [µm] = L/1000
Platform for moving and positioning Target Spectrometer on the floor
By: Udayasri Jandhyala Kanchan Joshi 03/18/2003 ME250 Prof. Furman.
Stages for the SSW translation system for PACMAN
TBL quadrupole mover prototype development
MultiView 400™ Product Presentation Nanonics MultiView 400™
Compact and Low Consumption Magnet Design The DESY Experience
DESIGN OF CONSTRAINT LECTURE
NC and CNC machines and Control Programming
Dhaval Desai Nathan Kleinhans Holly Liske Laura Piechura Kellen Sheedy
IENG 475: Computer-Controlled Manufacturing Systems
Presentation transcript:

DESIGN OF A TESTING MACHINE FOR MICRO-DEVICES Follow up to Clément Gabry’s master thesis on Structural Resistance of Silicon Membranes 1 12/10/2014CERN PH-DT-EO

Measurement devices displacement measurement load measurement optical table 12/10/2014CERN PH-DT-EO 2

12/10/2014CERN PH-DT-EO 3

CSEM Machine PI linear stage 17 mm travel ~ 1 um accuracy Load cell 2N range, 0.1mN accuracy 20N range, 1mN accuracy 12/10/2014CERN PH-DT-EO 4

New Machine Linear measurement travel range : > 1 mm resolution/incremental motion: 0.1 um Load cell ~ 1-25 N range 0.5 mN accuracy 12/10/2014CERN PH-DT-EO 5

Displacement type of test : apply displacement, measure load. type of devices linear actuator linear stage 12/10/2014CERN PH-DT-EO 6

Linear actuator 12/10/2014CERN PH-DT-EO 7 Advantages Simple geometry Allows an on-axis motion at all times Have good enough specifics Easy to mount Easy to replace Reasonable prices Price ~ 3’000 CHF

Linear Actuator Drawbacks More compliance in fixing method Compliance in mounting device Alignment problem (angular) Smaller travel ranges 50 N might introduce bending forces None linear encoder : backlash 12/10/2014CERN PH-DT-EO 8

Linear Actuator Solutions Hole “Meplas” BUT Feasible? Loses precision? 12/10/2014CERN PH-DT-EO 9

Linear Actuator Solutions external device Feasible Compliance Small alignment error 12/10/2014CERN PH-DT-EO 10

Piezo actuators very good precision good temperature ranges easy to mount and use price ranges affordable BUT travel range NOT enough (10s of microns) 12/10/2014CERN PH-DT-EO 11 Price ~ 2-4’000 CHF

Micro positioning stages some avoid the alignment problem very easy to mount stiffness BUT load just not enough 12/10/2014CERN PH-DT-EO 12 Price ~ 15’000 CHF

Piezo scanning stages Very good precision Possible to mount them on axis BUT Travel range too small (38 um) 12/10/2014CERN PH-DT-EO 13 Price ~ 9’000 CHF

Nano positioning stages Very good precision Easy to mount, or re-use Stiffness and “high loads” Long travel ranges BUT Out-of-axis loading problem 12/10/2014CERN PH-DT-EO 14 Price ~ 10’000 CHF

Nano positioning stage How to deal with the out of axis load? external device compliance adds weight to the load 12/10/2014CERN PH-DT-EO 15

Load Cells Positioning of the load cell on the actuator side non alignment problem again on the support : easy to fix easy to align easily changeable 12/10/2014CERN PH-DT-EO 16

Load Cells Type of load cell “donut type” avoids alignment problems Easy to fix stiffer than others 12/10/2014CERN PH-DT-EO 17

Optical Tables Gives a high flexibility in positioning Not too expensive (so far) Probably better than rails 12/10/2014CERN PH-DT-EO 18

Next step Modeling and analysis of errors influence of the notch-load non alignment influence of the out of axis load influence of the importance of symmetry influence of temperature on (optical) table and devices 12/10/2014CERN PH-DT-EO 19