Managed by UT-Battelle for the Department of Energy Weatherization Assistant: What’s New in Versions 8.4 and 8.5 Mark Ternes Mike Gettings Oak Ridge National.

Slides:



Advertisements
Similar presentations
O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY 1 Building Data Entry NEAT/MHEA Common Errors Oak Ridge National Laboratory Weatherization.
Advertisements

O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY 1 Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and Oak Ridge National.
Oregon Housing and Community Services Oregon State LIHEAP Weatherization Program NASCSP Annual Conference and DOE WAP State Managers Meeting September.
eQuest Quick Energy Simulation Tool
How to lower the energy use of your home David Parker Building Analyst/ Energy Auditor Parker Energy Solutions David Parker Building Analyst/ Energy Auditor.
SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
1 Proposed Revision to Energy Star New Homes Deemed Savings September 19, 2008.
Summary of Heat Loss Calculations Assessing overall heating requirements for building (E) Component U-ValueAreaHeat Loss Rate (W o C -1 ) Walls U walls.
Presentation to Barclay Owners November 21, 2013 Window Replacement Project Information Session.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM - December 2012eere.energy.gov Energy Audit Software WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Lecture 7: Building Modeling Questions Material prepared by GARD Analytics, Inc. and University of Illinois at Urbana-Champaign under contract to the National.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Home Depot Windows Autumn Glenn Phil Harris ME 340 – Winter 2009.
Understanding EPC Calculations Mark Sreeves and Lisa Dores.
The emphasis of the presentation should be on the status of the tasks and the accomplishments this semester. The organization should be similar to that.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
Adriana Galue Wolfgang Custom Finishes HOME ENERGY STATS Biggest energy consumers Space heating – 34% Appliances and lighting – 34% Refrigerator.
Earth’s Changing Environment Lecture 22 Energy Conservation in Heating and Cooling.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
BPA Pre-Pilot, Monmouth  14 homes with installed DHP, single zone, single compressor.  11 Monmouth, 2 Moses Lake, 1 Tacoma  Savings.
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
Washington State Low Income Weatherization Program Evaluation Calendar Year 2011 DRAFT Results Prepared by: Rick Kunkle July 2013.
1 Air Source Heat Pumps Potential Changes in the RTF’s Specifications & Savings Estimates and Their Impact on C&R Discount Program Credits.
SEEA Presentation to SEES March 2006 SEEA Presentation to SEES February 2006 SOUTHEAST ENERGY EFFICIENCY ALLIANCE.
PECULIARITIES ON VILNIUS MULTISTORIED HOUSING REFURBISHMENT FROM THE ENERGY EFFICIENCY ASPECT Prof. S.Raslanas, A.Gulbinas, L. Tupenaite Vilnius Gediminas.
1Managed by UT-Battelle for the Department of Energy Michael Blasnik M Blasnik & Associates Greg Dalhoff Dalhoff Associates, LLC David Carroll APPRISE.
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
Weatherization 201: Weatherization Works! Updated September 23, 2008.
CALRES Update Phase 1 Progress Report April 22, 2009 Bruce Wilcox Phil Niles Ken Nittler.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Weatherization Assistant Update (Version 8.3) Michael Gettings Oak Ridge National Laboratory.
1 | Program Name or Ancillary Texteere.energy.gov The Parker Ranch installation in Hawaii WEATHERIZATION ASSISTANCE PROGRAM Audits 201 Glen Salas SMS
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
HVAC and DHW System Conversion Cost and Energy Use Assumptions for Direct Use of Natural Gas Analysis September 28, 2010.
Attending the ICC Conference in Detroit this September or know someone who is?
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
Analysis of Weatherization Measures Options for Savings Methodology and Presentation of Costs from 6 th Plan Regional Technical Forum May 4 th, 2010.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
1 Energy Efficient Housing. 2 Why construct energy efficient structures? Bottom Line !!! Money It may save up to 60% of the cost to heat/cool the structure.
Review of the New England “Mini-Pilot” DHP Evaluation Why we ignore this study.
10. DENSITY  In addition to building design, there are other elements that can impact the passive potential of a site. Density, measured in Vancouver.
REM as a Compliance Tool Infiltration Trade-off REMRate vs. SEEM February 19th,
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Managed by UT-Battelle for the Department of Energy Weatherization Assistant: Ramp Up Support Mark Ternes Mike Gettings Oak Ridge National Laboratory 2009.
The National Energy Audit (NEAT) (Comparison of Popular Computer Audit Tools) Michael Gettings Oak Ridge National Laboratory.
1 | WEATHERIZATION ASSISTANCE PROGRAM – September 2012eere.energy.gov The Federal Perspective – Part 1 WEATHERIZATION ASSISTANCE PROGRAM – September 2012.
Executive Summary – In support of full Energyplus report 12/05/2013 Highlights Potential annual energy savings kWh Potential annual energy.
1 Mission Valley Power Energy Efficient Home Program and GSHP Deemed Savings Analysis September 30, 2008.
Week 6 The Energy Walk Through. Possible elements of a walk through Understand on-site information collection and listing of essential data for collection.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Week 7 Utility Data Analysis. Essential Elements Identify sources for obtaining utility data: paper form, electronically or from the internet Review utility.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY 1 Transitioning to Version 8 The Setup Library Oak Ridge National Laboratory Weatherization.
Direct Use of Natural Gas Status of Analysis Staff Analysis Today’s Agenda: Review of Major Analytical Input Assumptions Present Preliminary Results (Not.
1 How good are building simulation models? Comparing simulated and actual building energy consumption at the circuit level Brock Glasgo, PhD Student Engineering.
South Tyneside Homes The Decent Homes Programme January 2007.
1 Proposed Revision to Energy Star New Homes Deemed Savings September 19, 2008.
Washington State Weatherization Program Evaluation Julie Palakovich Weatherization Program Manager DOE National Weatherization Conference December 9, 2007.
Components and Families
Energy Efficient Mortgages
Compliance Software Tool Approval Technical Assistance Manual
Property Tax Levy – Taxes Payable 2019
Presentation transcript:

Managed by UT-Battelle for the Department of Energy Weatherization Assistant: What’s New in Versions 8.4 and 8.5 Mark Ternes Mike Gettings Oak Ridge National Laboratory 2009 National Weatherization Training Conference July 22, 2009

2Managed by UT-Battelle for the Department of Energy Purpose of This Presentation  Discuss MHEA field test and analyses results that led to important technical changes in Version 8.4 –MHEA field validation (overall performance) –BESTEST (UA values and space-heating load) –RESNET procedures (energy consumption) –True-up using the MHEA field validation homes (overall performance)  Summarize potential program impacts from use of the revised MHEA  Identify and discuss other changes that have been made in Version 8.4 and 8.5

3Managed by UT-Battelle for the Department of Energy MHEA Field Validation Study  Validation performed at DOE request before full implementation of MHEA  Validation report published November 2007 (ORNL/CON-501)  Findings (86 homes) –MHEA over predicted space-heating energy savings of weatherization measures by ~200% on average per home –MHEA achieved an average realization rate of ~35% (actual savings divided by predicted savings)

4Managed by UT-Battelle for the Department of Energy Home Energy Rating System (HERS) Building Energy Simulation Test (BESTEST)  Uses a basic single-family, site-built house that is simplistic enough to be modeled in MHEA  10 different test configurations of this basic house –Insulation and infiltration levels –Glazing properties and orientation –Shading –Internal loads

Comparison of UA Calculations ComponentBESTESTMHEA (final) Floor – R Floor – R Wall – R Wall – R Wall – R Ceiling – R Ceiling – R Ceiling – R Windows – DP, wood, argon Windows – SP, metal Doors Infiltration – 0.67 ACH Infiltration – 1.5 ACH

6Managed by UT-Battelle for the Department of Energy Conclusions Regarding MHEA’s UA Calculations  Some deviations from BESTEST occur: –NOT because MHEA calculations are wrong –But because MHEA accurately reflects mobile home construction or for other explainable reasons  MHEA accurately calculates the UA-values of mobile home envelope components

7Managed by UT-Battelle for the Department of Energy Space-Heating Load Analysis  MHEA UA-values made to equal BESTEST values to focus the analysis on the load calculation engine  BESTEST criteria are based on the results from three hourly simulation programs –DOE-2 –BLAST –SERI-RES  Loads calculated for a Denver climate  Space-cooling loads not examined

Comparison of Space-Heating Loads Test configuration Annual space-heating load (MBtu) BESTEST rangeMHEA L100A48.75 to L110A71.88 to L120A37.82 to L130A41.82 to L140A43.24 to L150A40.95 to L155A43.53 to L160A48.78 to L170A61.03 to L200A to

Comparison of Change in Loads Test configuration Change in annual space-heating load compared to a base case (MBtu) BESTEST rangeMHEA L100A L110A19.36 to L120A to L130A-27.5 to L140A to L150A to L155A-1.54 to L160A-3.72 to L170A7.12 to L200A56.39 to

10Managed by UT-Battelle for the Department of Energy Conclusions Regarding MHEA’s Space- Heating Load Calculations  MHEA passes the BESTEST criteria for each of the 10 test configurations, usually falling near the midpoint of BESTEST’s allowable range  MHEA accurately calculates the space- heating load of a mobile home  MHEA’s loads essentially track BLAST and are about 3-9 MBtu higher than DOE-2

11Managed by UT-Battelle for the Department of Energy RESNET Procedures  Tests space-heating energy consumption calculations for various heating systems using the BESTEST base case test configuration  Compares energy consumption of one heating system to another –90% AFUE furnace to a 78% AFUE unit –9.85 HSPF heat pump to a 6.8 HSPF unit –Electric resistance furnace to a 6.8 HSPF heat pump  RESNET results are based on the results of six hourly simulation programs –Two DOE-2.1 tools –Two DOE-2.2 tools –Micropas version 6.5 –TRNSYS version 15

12Managed by UT-Battelle for the Department of Energy Results and Conclusions Regarding MHEA’s Space-Heating Energy Consumption Calculations  MHEA accurately calculates the space- heating energy consumptions of the tested systems Heating system comparison Change in space-heating energy consumption (%) RESNET rangeMHEA 78% to 90% AFUE gas furnace-13.3% to -11.6%-13.3% 6.8 to 9.85 HSPF heat pump-29.0% to -16.7%-18.3% 6.8 HSPF HP to electric furnace41.8% to 80.8%52.3%

13Managed by UT-Battelle for the Department of Energy So  MHEA found to accurately calculate: –UA-values –Space-heating loads (essentially equivalent to BLAST or DOE-2) –Space-heating energy consumptions  But re-analysis using the MHEA field validation mobile homes showed that: –MHEA still over predicted savings by 168% –MHEA still achieved a realization rate of only 37%

14Managed by UT-Battelle for the Department of Energy Modifications to True-Up MHEA Predictions to Field Validation Results  Modeling of field validation homes in MHEA –Turned off programmable thermostat measure (12% of the homes) –Floor insulation levels of 0 in. changed to 0.5 in. (14% of the homes)  Engineering modifications to MHEA –Changed MHEA’s internal load assumptions to be more consistent with HERS and NEAT –Reduced MHEA’s infiltration loads by ~25% –Added an R-value of 1 to the ceiling, floor, and walls  Applied a 0.6 correction factor to MHEA’s energy savings calculations

16Managed by UT-Battelle for the Department of Energy Results from True-Up Modifications  MHEA’s over prediction of energy savings reduced to just 28%  MHEA’s realization rate increased to 78%  Use of MHEA’s optional billing adjustment feature can further improve MHEA’s accuracy on individual homes –Over prediction of energy savings reduced to 16% –Realization rate increased to 87%

21Managed by UT-Battelle for the Department of Energy Simulation of Program Impacts from Use of the Revised MHEA  Compared recommendations from the revised MHEA (Version 8.4) to the original (Version 8.3) –Frequency that measures are recommended –Average investment levels per home  18 mobile homes in Ohio –13 heated by natural gas –5 electrically heated  Columbus weather (5723 HDD)  State-supplied fuel and installation costs  Included health & safety and repair items

22Managed by UT-Battelle for the Department of Energy Program Impact Results and Conclusions  Use of the revised MHEA does NOT eliminate the recommendation of insulation measures –Roof: from 72% of the homes to 61% –Floor: from 89% of the homes to 61% –Wall: 17% for both versions of MHEA –Storm windows: 83% of the homes to 39%  Average investment levels remained high –Average investment per home dropped from $2832 to $2193 –Recommended investment level changed less than $130 in 39% of the homes

23Managed by UT-Battelle for the Department of Energy MHEA Steering Committee Comments  MHEA is now more accurate –Estimated energy savings and SIRs are more reasonable  The changes made in the revised MHEA move the recommendations in the right direction –Measures with questionable economics – like storm windows or insulating a roof with a decent amount of insulation in it – are less likely to be recommended  Recommend issuing the revised MHEA once remaining programming issues are resolved

24Managed by UT-Battelle for the Department of Energy Conclusions  MHEA’s basic engineering calculations were found to be accurate  Several adjustments had to be introduced into MHEA to make its energy estimates agree with measured field data  Recommendations appear to be reasonable  Program impacts compared to Version 8.3 appear to be reasonable and as expected  Final report published December 2008 (ORNL/CON-506)  Version 8.4 of the Weatherization Assistant with the revised MHEA was released November 14, 2008