Riverton City Steel Framed Structure We used AutoDesk Revit to model the structure. We also created approximate models of the salters to get an idea of.

Slides:



Advertisements
Similar presentations
Potential Solutions Goals for Design – What are we concerned about? –Primary Goal: Get the deck on successfully Stability during deck pour Stability during.
Advertisements

Steel Construction Manual
Structural Steel Construction
BEAMS (FLEXURE) BEAM- COLUMNS SHEAR / CONC. LOADS
Design of Seismic-Resistant Steel Building Structures
Beam Design Beam Design Civil Engineering and Architecture
Beams Stephen Krone, DSc, PE University of Toledo.
8621 Georgia Avenue Silver Spring, MD
Parts of typical slab formwork
Prof Awad S. Hanna Concrete Structures Concrete Structures.
CEE Capstone II Structural Engineering
Overview Waffle Slab.
Fraser Centre State College, PA Tyler Strange Structural Option Consultant: Dr. Thomas Boothby April 13, 2011 Tyler StrangeStructural Option Fraser Centre.
LRFD-Steel Design Dr. Ali Tayeh Second Semester
Carl Hubben – Structural Option Ae senior thesis Office Building-G EASTERN UNITED STATES.
Shear Design of Beams CE Steel Design Class By, Amit H. Varma.
Shear Design of Beams CE Steel Design Class By: Amit H. Varma.
CTC 422 Design of Steel Structures
Structural drawing Instructor: M.Yaqub
Buckling Critical Load Considerations
CON 4003, CVE 4073, CVE 5073 Construction Estimating Prof R. V. Locurcio, PE.
Milton S. Hershey Medical Center Biomedical Research Building Joshua Zolko, Structural Option.
Penn State Hershey Medical Center Children’s Hospital Hershey, Pennsylvania Matthew Vandersall Structural Option AE Senior Thesis Dr. Richard Behr.
What you need today Text Notebook Calculator (optional) 1/8” = 1’ print of foundation (basement) plan –With dimensions.
Slab Form Design.
Structural Steel Prof Awad S. Hanna.
Crocker West Building State College, Pa Eric M. FosterStructural OptionSpring 2009.
Daniel Bellay Lancaster County Bible Church Structural Option Lancaster County Bible Church.
LRFD- Steel Design Dr. Ali I. Tayeh First Semester Dr. Ali I. Tayeh First Semester.
STRUT & TIE MODELS (S-T-M)
Senior Thesis Structural Option Ryan Friis Spring Morgan St. Chicago, IL 111 Morgan St. Chicago, IL Ryan Friis Structural Option.
By Reza Esfandiari, SULI Program Mentor: Carsten Hast August 14, 2009.
Structural Steel Shapes
GARY NEWMAN STRUCTURES OPTION ADVISOR: DR. HANAGAN SENIOR THESIS PRESENTATION SPRING 2008.
CTC 422 Design of Steel Structures
CON 4003 Construction Estimating Prof R. V. Locurcio.
BRYAN DARRIN SENIOR THESIS PRESENTATION MILLENNIUM HALL DREXEL CAMPUS PHILADELPHIA, PA.
LRFD – Floor beam Unbraced top flange. Lateral Torsion Buckling  We have to check if there is plastic failure (yielding) or lateral-torsion buckling.
Duquesne University Forbes Expansion
SEAN BEVILLE STRUCTURAL OPTION ADVISOR: PROF. BOOTHBY APRIL 13, 2009 TEMECULA MEDICAL CENTER “STRUCTURAL SYSTEM OPTIMIZATION” THE DEPARTMENT OF ARCHITECTURAL.
Helios Plaza Houston, TX Advisor - Dr. Hanagan Kevin Zinsmeister Structural Option.
Traci Peterson Structural Option Senior Thesis Presentation The Del Monte Center at The North Shore The Pennsylvania State University Department of Architectural.
Ryan Pletz Structural Dr. Hanagan The Pennsylvania State University Department of Architectural Engineering Senior Thesis April 14, 2008.
DR. Nabil Dmaidi Structural Steel. DR. Nabil Dmaidi Type of Steel n Designated by the letter “A” followed by the American Society for Testing and Materials.
Brad Oliver – Structural Option Advisor – Professor Memari.
Justin Purcell Structural Option Advisor: Dr. Hanagan.
CON 4003 Construction Estimating Prof R. V. Locurcio.
Structural Curriculum for Construction Management and Architecture Students 1 Prepared by: Ajay Shanker, Ph.D., P.E. Associate Professor Rinker School.
James C. Renick School of Education PSU AE Senior Thesis 2006 Mick Leso - Structural North Carolina A&T State University - Greensboro.
Cover Plated Beams Used in renovation or restoration projects or to meet difficult depth limitations.
Structural Drafting Assembly Clearance Dimensions.
Beam Design Beams are designed to safely support the design loads.
PROBLEM # 2 SQUARE HSS Page # 4-52.
CESL Hotel Unique – Toronto Chris O’Brien Eric Fraser Scotia Mabury
Biobehavioral Health Building The Pennsylvania State University Daniel Bodde Structural Option Advisor – Heather Sustersic.
THE NORTHBROOK CORPORATE CENTER Redesign of the Lateral Load Resisting System.
General Comparison between AISC LRFD and ASD
Structural Systems Design for a Laramie Office Building
Structural Steel Construction
Airplane Hangar Design The design of a steel-framed airplane hangar Matthew Klein Edward F. Cross School of Engineering, Walla Walla University, College.
What Is Steel Bridge? National design competition 20’ Steel bridge
Structural drawing.
Arch205 building construction wall systems- Steel
CE Steel Design Class By, Amit H. Varma
DESIGN OF TRUSS ROOF Chapter 7
Concrete Structures DR. Nabil Dmaidi.
Find: The Lightest I Beam
Find: Fcr [lb/in2] Fcr E = 2.9 * 107 [lb/in2] fy = 36,000 [lb/in2]
EAT 415 :ADVANCED STEEL BUILDING DESIGN PLATE GIRDER
Mitre III Building McLean VA Debra Schroeder Structural Option.
Presentation transcript:

Riverton City Steel Framed Structure We used AutoDesk Revit to model the structure. We also created approximate models of the salters to get an idea of how they would look in the structure. Riverton City Public Works moved to a new location and requested the design for the relocation of a steel framed structure to store their snow-plow salters during the summer months. While the structure would be rebuilt as before, it was requested that (4) additional beams (referred to as salter beams) be added to support (4) 3.1 kip snow plow salters. Considering the additional weight of the salters, it was also required that the footings be re-designed to support the new loads and that the existing beams and columns be analyzed to verify that they could support the new weight. The purpose of the structure is to allow the snow plow trucks to back into the structure with the new steel beams in place and still be able to easily load the salters on the truck. After demands for the critical beams and columns were calculated by hand and verified by StruCalc, the footings for the new structure were designed. The square footing design can be seen in the detail below. The footings were also designed for the possibility that the snow plow truck drives over the top of the footing. We decided early on that we would choose a W8-shape beam to support the salters since this shape would fit nicely inside the flanges of the girder, making for easier construction. Our final recommendation for beam size is a W8X21. This beam’s capacity meets all of the demands, as seen in the table below. The shape of the salter beams was decided after consulting Michael Hunsaker at PDM Steel. Here we learned which shapes were most common and therefore cheapest. W-shapes proved to be the cheapest at $0.38 per pound, while HSS started around $0.50 per pound. Table 4, provided below, shows the overall cost of new materials and labor. By our estimates, the project may cost less than $2000. Limiting StatesDemandCapacity Yielding [kip-ft] Lateral Torsional Buckling [kip-ft] Shear [kip] Deflection [in]< MaterialSizeLength/VolumeQuantityTotal Cost ($) Weld for salter beam3/16"6" Weld for baseplate1/4"sufficient W8x21 15' Rebar#430" Concrete36"x36"x30"22.5 ft Anchor Bolts1/2"7" Labor Grand Total$ To connect the salter beams to the girders, Riverton City Public Works requested a weld connection. Since the salter beams fit nicely within the flanges of the girders, we have specified two 6” long web-to-web 3/16” fillet welds for each salter-girder connection. The demands were less than 3 kips and the weld provides a 50 kip capacity. If desired, welds only 2” long will still exceed the demands by 14 kips. Using AutoCAD, we created plans for the structure so that construction of the footings and the addition of the salter beams could go as smoothly as possible. To design the most cost-efficient structure, we needed to explore several options. Several options were easy to rule out due to cost of material, including using HSS pipes in place of W-shape for the salter beams. A second option was to flip the two bays so the original girders could also act as the salter beams. This would cut out the cost of the salter beams altogether and only require slightly larger footings. However, since the roofing was installed in one direction, the tin and channels were already designed to fit that direction. Changing this would call for new tin and channels, and could cost more than adding four beams to hold the salters. At the request of Riverton City Public Works, we considered seismic design. However, laterally bracing the structure would require cross bracing through the bays, which would render them useless or impractical (as seen below). Our official recommendation is that seismic design not be pursued. The demands on the existing columns and girders were recalculated and the capacities exceed the demands. No additional members are needed. The final steel framed structure is designed to support (4) snow plow salters, two in each bay. Each salter will be supported by two W8X21 beams, with a total of (4) beams. These added beams will fit snugly within the flanges of the existing W12X40 girders, which will allow each beam and girder to be welded web-to-web with two 6” long 3/16” fillet welds. Each footing has been designed to withstand a demand of 16.2 kips. The square footing dimensions are 3 ft 2 and 30 inches deep, to meet permafrost depth requirements.