MP-3000 Motor Protection.

Slides:



Advertisements
Similar presentations
SIRIUS Motor Management
Advertisements

Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
NERC Lessons Learned Summary December NERC lessons learned published in December 2014 Three NERC lessons learned (LL) were published in December.
In this presentation you will:
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com.
SYMAP-BC SYMAP-BC.
Generator Management Relay
BSA Electricity Merit Badge Electricity Merit Badge AC Alternating Current.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
G GE Power Management MMII Intelligent MCC Controller.
Basic Electricity.
Chapter 8 Output Modules.
PLC Fundamentals Module 2: Hardware and Terminology.
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
MIG II DIGITAL FEEDER PROTECTION
SECTION 4 ELECTRIC MOTORS UNIT 19 MOTOR CONTROLS.
Chapter 7 SYSTEM PROTECTION
Section 4: Electric Motors
Motor Protection for this Millennium
G GE Power Management 369 Motor Management Relay.
Chapter 3 Manual Starters.
Workflow Based Tools Simplifying All Job Functions.
G650 Generator Protection & Control System
Looking for a more powerful circuit monitor?
Smart transmitters.
High Sensitivity Smoke Detection
Developments in the IntelliFIBER ™ Fiber Optic Fence Sensor
Electrical Distribution Training
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
VS mini J7 COMPACT INVERTER FOR GENERAL USE
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
3-Phase Submersible Motor Control
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Motor. What Does it Do? Monitors three phase motors for a number of current, temperature, estimated power and timing parameters. Provides motor protection.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
Introduction to Energy Management. Week/Lesson 12 Advanced Technology for Effective Facility Control.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
© 2015 Eaton. All Rights Reserved. Motor Protection & Communication for Critical Loads Darrell Ouellette Technology Application Specialist.
G GE Power Management 269Plus Motor Management Relay.
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. Insert Photo Here Bulletin 193/592 E1 Plus EtherNet/IP® Side Mount Module External Presentation.
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
HighPROTEC-2 MRA4-2 Directional Feeder Relay Sales presentation
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
HighPROTEC-2 MRMV4-2 Motor protection relay with voltage measurement Sales presentation 2015/08/10.
Protection and Relay Schemes
SGC-250 Synchronous Generator Controller
HighPROTEC-2 MRM4-2 Motor Protection Relay Sales presentation
HighPROTEC-2 MCDTV4-2 Transformer Protection with differential Sales presentation 2015/08/10.
HighPROTEC-2 MCA4-2 Directional Feeder Relay Sales presentation
FEEDER PROTECTION UNIT
MOTOR PROTECTION SYSTEM
MPU-16A / FPU-16 TEST UNIT TUTORIAL
Programmable Logic Controllers (PLCs) An Overview.
PowerValue 11/31 T Sales Presentation
Chapter 7 System Protection
HighPROTEC-2 MRDT4-2 Transformer Protection with differential Sales presentation 2015/08/10.
Agenda Introduction of Protective Relays
Presentation transcript:

MP-3000 Motor Protection

Motor Protection Award Winning Design! Protects three phase induction motors of any size and any voltage Patented motor thermal model -field proven in over 20,000 applications world wide Maintenance-free microprocessor based relay design Keeps your motor running safely Recognized to UL1053 Ground Fault Protection Standard MP-3000

Motor Considerations Motor Importance Motor Characteristics Horsepower rating Rated Voltage, speed, service factor, etc. Motor starting condition Motor Cost Connected Power System

Motor Failures Overload/overheating Electrical Short Circuits Phase to ground Faults Phase to phase faults Mechanical Failures Bearings Couplings

Abnormal Conditions Phase Unbalance Single Phase Stall or locked rotor Jam Loss of load Transition

MP3000 Catalog Numbers MP3000 Fixed case, 5 A MP3001 Drawout case, 5 A, no communications MP3002 Drawout case, 5 A, INCOM communications 1 Amp versions available MP3000 priced at $2250 vs. 269+ at $2837 Drawout option for MP3000 is $350 adder versus Multilin $1100 adder

MP3000 Value Packs MP3000 VPR: MP3000, URTD, RS-232 PONI and MPFO-5 MP3000 VPI: MP3000, URTD, IPONI and MPFO-5 Value Pack pricing competitive with 269+ MP3000-INCOM: MP3000 plus IPONI MP3000-RS232: MP3000 plus RS232 PONI

Motor Protection Accessories Universal RTD module (URTD) One style supports up to 11 RTD inputs Handles copper, nickel or platinum RTD’s Mounting on back of relay or separately Electrical or fiber optic communications to relay IQDCPS DC to AC power supply for DC control power applications IPONI for MP-3000’s MPFO-1 - 1 meter Fiber Optic Cable for URTD/MP3000 MPFO-5 - 5 meter Fiber Optic Cable for URTD /MP3000 MPFO-10 - 10 meter Fiber Optic Cable for URTD /MP3000

Ampgard Pricing MP3000 fixed case $3,400 Multilin 269plus $7,050 369 base $6,830 RTD $400 Metering $1,630 Back Spin $3,220 469 $11,480

MP-3000 Motor Relay Based on IQ 1000 II - the first microprocessor multifunction motor protection relay Development program to update the protection, hardware and user interface. Over 50 new features Drawout case option UNIVERSAL RTD MODULE Cutler-Hammer

Motor Protection MP-3000 URTD Protection Functions 49/51 Overload I2T 11 RTD’s Electrical or Fiber Optic Interface Motor Protection Functions 49/51 Overload I2T 49S/51 Locked Rotor 51R Jam/Stall 37 Loss of Load/Underload 46 Phase Loss/Unbalance 50 Phase Instantaneous OC 50G Ground Inst. OC 66 Starts per time period

MP-3000 Features Microprocessor Technology Advanced protection algorithms Self diagnostics Simple to use - On-line Help Feature True RMS Current Sensing Meets UL1053 Ground Fault Protection Standard Loss of voltage ride through time of 30 cycles

Intel-I-TripTM Intelligent Motor Overload Protection with adaptive Characteristics Builds custom protection curve for each motor to insure accurate motor protection Uses standard information from the motor manufacture - full load amps, locked rotor current, stall time and service factor Accurate positive and negative sequence current measurements Patented, field proven motor thermal model used in over ten thousand applications world-wide Adaptive overload trip characteristics with RTD input based on measured motor temperatures

MP-3000 Processor Model

I = I1 (positive sequence) + k * I2 (negative sequence) Rotor I2t Protection I I1 I2 I = I1 (positive sequence) + k * I2 (negative sequence) (Overload protection includes additional heating effect of negative sequence current)

MP3000 I1 and I2 Measurements

MP 3000 New Features Protection operational while in program mode Long Acceleration time with Zero speed switch input Enhanced RTD monitoring and diagnostics Motor load shedding feature for external load control User configurable inputs and outputs for greater application flexibility Optional Quick Release draw out case New Armed / Disarmed Function to ensure that false tripping will not occur on installation and commissioning Trip or alarm option on relay failure detection Emergency Override resets thermal bucket and timers to permit motor starting

MP-3000 Communications Requires optional IPONI or RS232 PONI Can Daisy Chain up to 1000 devices on INCOM LAN. Configure set points & set real time clock . Backward compatible with IQ1000 II. Alarm status available over INCOM. Event logging with date and time stamp New feature - motor starting curve data, average current vs time, over INCOM. Begin 100 ms after start declaration End 5 cycles after run transition or trip Data points per time based on locked rotor time. Sends both recorded curve and calculated thermal trip curve for margin comparison IQ1000 supports singly command resets that is not a good idea.

STARTING CURRENT PROFILE MP3000 Overload Trip Curve Locked Rotor Motor Acceleration Curve

Application: Reduced Voltage Starters TRANSITION CURRENT SETTING Amps On Off MOTOR CURRENT TRANSITION RELAY Smooth transition from reduced voltage to full voltage based on motor starting current, time or a combination of time and/or current Prolonged autotransformer/reactor life by quicker removal Incomplete sequence verifies proper transition

Motors with RTDs Separate Universal RTD Module -- Reduces installed cost by mounting module near motor Fiber optic connector -- Eliminates need of Copper Wire Connection to MP-3000 (or connect both for redundancy) One catalog number for all RTDs -- Simplifies Inventory & Ordering Adjusts Overcurrent Algorithm -- Reduces Nuisance Trips Extra RTD input -- Increases Temperature Monitoring Capability Stand-alone Capability -- Lowers Cost of Monitoring Temperature of Motors, Transformers, Other Equipment Relay will check coherency of URTD data - e.g. rate of temperature change. Alarming and diagnostics - will use URTD diagnostic data. Fail-safe behavior on communications loss

MP3000 MMI Four interface operating modes Setting mode for changing settings Monitor mode for readout of operating conditions History mode for motor operation history Log mode for detail records of trip, alarm and start operations

Monitor Mode Current-displays motor currents RTD-displays motor, bearing and load temperatures Motor-displays motor run and start data Before 32 different items in one large page. Now a page of 9 items 11 items and 5 items

History Mode Motor Statistics Number of trip events Number of alarm events Permanent history Time and date that event occurred, or time and date counting began, is available The time/date start-point can be reset for the whole page Pressing RESET while in history mode will reset the time date stamp and the value of the statistic. In other modes this would bring you up one menu level,… is this dangerous. Should we make any history like run time or op count so that you can’t reset it? Also a line is provided to reset the entire page’s date time stamps and values.

Log Mode Log book- records 100 events with date and time stamping Event- detailed record of 20 trip & alarm events with date and time stamping Start- detailed record of the last 4 starts with date and time stamping Once twenty events have been recorded the oldest event will be displaced to make room for a new event.

Log Event Alarms and trips type of trip or alarm date and time of event is recorded phase and ground currents at time of trip % of I2T capability at time of trip phase unbalance at time of trip Highest RTD temp in each of 4 groups Up to 20 events stored

Log Start Event Date and time of event is recorded Highest phase and ground current during start Highest phase unbalance during start The average current at the time of transition The time taken from start to current transition The time taken from start to actual transition

Program Mode Motor Page RTD Page Trip Page Alarm Page Start Page Discrete Input Pages Alarm and Auxiliary Relay Output Pages Analog Output Page System Page Test Page Reset Page Program mode entered and exited only by pressing program button. Extra security in that entering program mode is logged for later retrieval. Notice that page button is now the mode button and up and down movement is not supported is this a problem?

System Page Output relays individually configurable as mode 1 or mode 2 (fail-safe mode) Real Time Clock setting. 24 or 12 hour time format ; M/D/Yr or D/M/Yr date format. Select MP-3000 mode or IQ1000 II emulation mode for IMPACC. New feature - Armed / Disarmed Function Requested for hot-plug-in replacements. Unique feature to ensure that false tripping will not occur By making at least one output mode 2 the user can be notified on total instrument failure.

More Pages Test Page Ability to toggle any one of 4 outputs individually Force Analog output to 4, 12, or 20 ma Read the state of both discrete inputs Reset Page History pages can be reset in groups Permanent History can not be reset

MP-3000 Motor Protection Hardware Connections

MP-3000 Motor Protection Trip Characteristics

Motor Current Profile

I2t & Instantaneous

Underload & Jam

Trip Characteristics without RTDs

Trip Characteristics with RTDs

MP-3000 Motor Protection PowerNet Screens Relay Settings