EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague1 A fast LED driver prototype for HCAL calibration EUDET annual meeting at Ecole Polytechnique, Palaisau.

Slides:



Advertisements
Similar presentations
Jiri Kvasnicka, EUDET meeting at DESY 1 Optical fibre calibration system Jiri Kvasnicka Outline Results from recent tests – LAB Test.
Advertisements

HH Dec 13Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1.
Optical Fiber Calibration System and Adaptive Power Supply Jiri Kvasnicka, Ivo Polak, Jaroslav Cvach Prague, Institute of Physics Gerald Eigen,
LED calibration systems for CALICE hadron calorimeter June 11, 2011TIPP 2011, Chicago1.
NIU Electronics' Group By Manuel I. Martin. NIU June 16, Long Term Goal Design a local DAQ system for the proposed DHC including the Front End electronics.
LED Current Source Design of the circuit to provide constant current supply to the LED Calibrate LED with reference to MIP signal value Expand the design.
LCWS2010, Beijing, 2010 MAR29 Ivo Polák, FZU, Prague1 LED notched fibre system at AHCAL Calibration system for SiPM Ivo Polák 1.Notched fibre.
Calice, UT ArlingtonJiri Kvasnicka, FZU, Prague1 LED notched fiber system Jiri Kvasnicka 1.Introduction 2.Test setup and fiber layout on HBU0.
Ivo Polák SiPM needs short optical pulses
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka, Ivo Polak Institute of Physics (FZU), Prague June 11, 2011TIPP 2011, Kvasnicka1 The.
Novel approach for calibration breakdown voltage of large area SiPM
ECFA, JUN10, 2008Ivo Polak, IPASCR, Prague1 Electronics part of AHCAL calibration system ECFA meeting at Warszawa.
Sep 13, 2007CALICE Collaboration Meeting Prague 1 Long term test of LED pulsing  Long LED system stability measurement  Aging of part of optical system.
External calibration system - QMB6 Distribution of light: Notched Fiber Calibration and Monitoring Board (CMB) 1-ch LED driver (QMB1) Calibration System.
DESY, DEC-2013Ivo Polák, FZU, Prague1 Activity on Adaptive power & Calibration at Prague Ivo Polák, on behalf of Prague’s group QMB1A update.
Tests of the fiber-based calibration system CALICE collaboration meeting Cambridge, UK 2012/9/18 Jaroslav Zalesak Institute of Physics, Prague  QMB1 LED.
Mathias Reinecke CALICE meeting Argonne EUDET module – Electronics Integration Contents -Next prototype : architecture -HCAL Base Unit (HBU)
Feb 20, 2009 CALICE meeting, Daegu, Korea QRL in Magnetic Field 1 QRLed Driver in Magnetic Field Jaroslav Zalesak Institute of Physics of the ASCR, Prague.
Iowa LED system for CMS HCAL By M. Miller Y. Onel University of Iowa, Iowa City, IA CMS Meeting, CERN December 1-8, 2001.
1 Applied Control Systems Technology. 2 Pin configuration Applied Control Systems.
Optical calibration system for EUDET AHCAL module Jaroslav Cvach IPASCR 1.Calibration system for SiPM photodetectors 2.QRLED driver photoelectron spectra.
AHCAL – Electromechanical Integration EUDET annual meeting – Paris Oct M. Reinecke.
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka Institute of Physics, Prague June 11, 2011TIPP 2011, Chicago1 Under.
LED calibration systems for CALICE hadron calorimeter
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
LCWA, ALCPG 2009 Albuquerque, NM Ivo Polák, FZU, Prague1 Calibration system of CALICE AHCAL detector Ivo Polák 1.Two calibration light distribution.
CALICE ANL, MAR18, 2008 Ivo Polak, IPASCR, Prague1 A fast LED driver prototype for HCAL calibration CALICE meeting at ANL, USA.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Munich, 18 Oct 2006J. Cvach, annual JRA31 JRA3 Institute of Physics ASCR Prague 1.ECAL, VFCAL (V. Vrba) 2.HCAL (J. Cvach) 3.Exchange in NA2 (travels 8.5.
1. DESY tests 2. Electronics developments 3. Optical developments 4. Outlook Casablanca J. Cvach, CALICE Coll. meeting.
ANL, MAR-2014Ivo Polák, FZU, Prague1 Activity on Compass 2 detector with Calibration at Prague Ivo Polák, on behalf of Prague’s group Compass.
HCAL – Integration Plans Mathias ReineckeHCAL – Main meeting Introduction 2.HCAL Base Unit (HBU) - Update 3.Testboards 4.Light Calibration System.
NVNA Applications Loren Betts Component Test Division.
Optical Part of the CMB for AHCAL-CALICE Jaroslav Zalesak Institute of Physics, Prague.
R&D for a 2nd generation AHCAL prototype LCWS 2007 – DESY Hamburg Mathias Reinecke on behalf of the AHCAL partners.
May - 20Ivo Polák, FZU, Prague1 LED notched fibre distributing system Calibration system for SiPM Ivo Polák, on behalf prague’s group
5 July 2010Ivo Polák, FZU, Prague LED notched fibre distributing system Calibration system for SiPM Ivo Polák, Ji ř í Kvasni č ka
oct - 6Ivo Polák, FZU, Prague1 Calibration system for SiPM and LED notched fibre distributing system Ivo Polák, on behalf prague’s group
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka, Ivo Polak, Institute of Physics, Prague June 11, 2011TIPP 2011, Kvasnicka1 The CALICE.
Service Learning Project SLICE Prototype Fabrication Experience Ability Switch Test Box.
Main HCAL, JUL1,2008Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers HCAL main meeting, DESY.
1 Overview of the HCAL LED monitoring PRR note CALO meeting Anatoli Konoplyannikov ABSTRACT In this note the design and integration of the LED.
Scintillator HCAL read-out and calibration Felix Sefkow TILC08 at Sendai, Japan March 4, 2008.
The 2 nd SCECAL module for the Fermilab beam test - tentative idea - S. Uozumi (Shinshu) Jun GLDCAL meeting Next beam test will be held likely.
Tile HCAL status Felix Sefkow CALICE Technical Board Review April 19, 2007.
ShinShu, 2012 Mar 6Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 with HBU2 test Ivo Polák, on behalf of Prague’s group
2011 Sept 14-16Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1.
Annual EUDET, OCT6,2008 Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers for AHCAL EUDET annual meeting, NIKHEF 1.Introduction 2.QRLed.
Hadron Calorimeter Felix Sefkow EUDET Extended Steering Meeting September 11, 2006.
1 9 December 2002A.P.Kashchuk (LNF/INFN), Frascati) New approach to CPC design.
AHCAL Integration. Status and Outlook Mathias Reinecke for the AHCAL developers CALICE week Lyon IPNL, Sept. 16th – 18th, 2009.
Guide Presented by Mr.M Cheenya V.Abhinav Kumar 11E31A0422 Asst.Professor K.Shiva Kumar 11E31A0423 K.Rajashekhar 11E31A0424 K.Chaithanya Sree 11E31A0428.
HCAL1 Status 2004 Oleg Gavrishchuk, JINR, Dubna 1. HCAL1 performance in 2004 General design High Voltage system LED monitoring 2. Stability in 2003 Led.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
DESY, 8 Dec 2005J. Cvach, prekick-off JRA3 JRA3 Institute of Physics ASCR Prague 1.ECAL, VFCAL (V. Vrba) 2.HCAL (J. Cvach) 3.Exchange in NA2 (travels 8.5.
LED notched fibre distributing system Calibration system for SiPM
JRA3 Institute of Physics ASCR Prague
LED notched fibre system short HBU0 party with QMB6
A fast LED driver prototype for HCAL calibration
Baby MIND Collaboration Meeting #2
New LED driver Preliminary tests
CALICE meeting 2007 – Prague
HCAL task status report
LED notched fibre system at AHCAL Calibration system for SiPM
HCAL Modules -First Ideas
Chapter 26 Optoelectric Devices.
CALICE meeting 2007 – Prague
Read Delay Simulations
Status of the EUDET Prototype
A fast LED driver prototype for HCAL calibration
Presentation transcript:

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague1 A fast LED driver prototype for HCAL calibration EUDET annual meeting at Ecole Polytechnique, Palaisau

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague2 Proposal for calibration system New LED driver with reduced crosstalk A tunable calibration light in the range 0 to 100MIP Simplification of the optical system: one LED -> one side emitting fibre, one row of scintillator tiles PIN photo diode, do we need them?

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague3 LED driver strategy for SiPM calibration At AHCAL prototype (uses SiPM), we used CMB, calibration system with UV-LED 400nm driven by very fast rectangular pulses (1ns rise/fall time). Steep Rectangular waveform satisfied the needs to vary pulse-width, BUT creates lots of harmonics  electromagnetic crosstalk! We have found fixed pulse-width to about 6ns, we can go to use narrow band ->smooth waveform ≈ less RF interference = Quasi Resonant LED driver (single pulse)

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague4 Quasi-Resonant LED driver LC circuit, heavily dumped Simulation ~ 5ns puls width (slightly depends on the amplitude) 33nH PCB inductance, no ferromagnetic core Prototyping Used my lovely single side copper foil PCB We need more work on components optimization

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague5 QR LED driver Simulation oscilloscope

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague6 Simulation at 1.5V amplitude XSC1 : Upper trace - sync pulse Lower trace – voltage at LED hot end XSC2: Lower trace LED current

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague7 Simulation at 3V XSC1 : Upper trace - sync pulse Lower trace – voltage at LED hot end XSC2: Lower trace LED current

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague8 Prototype of QR LED driver

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague9 LED current waveform (GRN) a=3

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague10 LED current waveform (GRN) a=2

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague11 LED current waveform (GRN) a=1

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague12 Last tests, more power on LED We see response of PIN photodiode at oscilloscope Amplitude up to 50 Ω

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague13 Response to low amplitude LED current (cyan) 10Ohm) PIN response (yellow) LED anode (violet)

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague14 Response to middle amplitude

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague15 Response to high amplitude 200mA current at LED

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague16 Response to high amplitude The Light from LED was optically blocked to PIN.

EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague17 Conclusion QR LED driver is very promising technique to reduce Electro-Magnetic-Interferences PCB of the two-channel QR LED driver is being designed now End of October - PCB will be assembled – ready for tests November – summary report to EUDET November – measurements of light transfer in side-emitting fibres