Presentation is loading. Please wait.

Presentation is loading. Please wait.

HH - 2011 Dec 13Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1.

Similar presentations


Presentation on theme: "HH - 2011 Dec 13Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1."— Presentation transcript:

1 HH - 2011 Dec 13Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group polaki@fzu.cz 1.QMB1 specifications 2.QMB1 with Trigger distribution 3.First test with HBU2 4.Notched fibre, semiautomatic machine 5.Resume

2 HH - 2011 Dec 13Ivo Polák, FZU, Prague2 QMB1 Quasi resonant Main Board –Modular system, 1 LED per board –Operation mode: DAQ + CANbus control stand-alone mode –LVDS Trigger distribution system –Variable amplitude, zero to maximum (~1Amp) smooth –Pulse width fixed to ~ 5ns (UV or blue LED) –Voltages and temperature monitoring –Size of PCB: width 30mm, depth 140mm

3 HH - 2011 Dec 13Ivo Polák, FZU, Prague3 Principal schema Larger inductor than the older QMB6

4 HH - 2011 Dec 13Ivo Polák, FZU, Prague4 TRIGGER (T-calib) LVDS distribution to QMB1 Trigger from DAQ master slave Terminated 120ohm RX TX LVDS Up to 6 + 6 slaves modules

5 HH - 2011 Dec 13Ivo Polák, FZU, Prague5 Signal distribution at 30 x 140 mm^2 Two flat cables, Twisted pair for Trigger

6 HH - 2011 Dec 13Ivo Polák, FZU, Prague6 Frame with 5 (and 1 spare) QMB1

7 HH - 2011 Dec 13Ivo Polák, FZU, Prague7 3D draw of QMB1 LED fibre PWR 15V and CANbus T-calib LVDS flat cable

8 HH - 2011 Dec 13Ivo Polák, FZU, Prague8 Real single LED board QMB1 Power 15V 60mA High level of LED peaks, 1.7A in pulse Delay can be easily trimmed within 9ns LED pulse width is shorter than expected 2ns, seen with current probe Tested now in stand- alone mode

9 HH - 2011 Dec 13Ivo Polák, FZU, Prague9 PIN-PD response to QMB1 flash PIN-PD only, no preamp 5ns/div Upper: PIN-PD w preamp 10ns/div Lower: PIN-PD w preamp 50ns/div Maximal LED amplitude, LED airgap to PIN-PD

10 HH - 2011 Dec 13Ivo Polák, FZU, Prague10 DESY test setup in December 2012 HBU2 DIF, PWR, CAL QMB1 T-calib from DAQ CANbus SPIROC2 PWR 15V combiner Notched fibres Single layer frame

11 HH - 2011 Dec 13Ivo Polák, FZU, Prague11 DESY test setup in December Notched fibre (routed in paralel with blue line) Only 11 points were illuminated properly

12 HH - 2011 Dec 13Ivo Polák, FZU, Prague12 Quick Friday’s QMB1 test with HBU2 Some config troubles occurred Generally, system is working easily, run in stand-alone mode Pulse position at different LEDs can be easy tuned within 1ns Near future plans (tomorrow) –Hold scan –Better notched fibre to install –Single p.e. peak spectra Next year plan (February) –More channels equipped with scintillators –Xtalk and light spread study System is working!, but Big spread due to combination of factors: Bad fibre, hold scan did not matched Distribution will be better, do not worry!

13 HH - 2011 Dec 13Ivo Polák, FZU, Prague13 Notched fibres external company Safibra preparing the setup (semiautomat) to produce precise notches in the fibres We assume to have fibres made by new technology in 1.Q 2012, we assume less spread of the light at taps (<15% ). prototype fibres showed some systematic error (decay) in distribution of light, two test methodes  two results: flat and with decay. Under investigation now. illuminated by Green laser 24 notches

14 HH - 2011 Dec 13Ivo Polák, FZU, Prague14 Notched fibres Semi-automatic tool Frame with x-y stepper motors Drill machine used as milling cutter to groove the notch Alu/PCB Template with moving scint tile PCB with 3mm holes Scintilator tile w SiPM Now in operational debugging & sw development stage

15 HH - 2011 Dec 13Ivo Polák, FZU, Prague15 work at autumn of 2011 QMB1 (1-chanel LED driver): –Done 6 pcs of QMB1 in hand Tune QRLed driver to 405nm LED Trigger distribution (LVDS) proved Trigger delay can be tuned by C trimmer (~10ns) A few bugs in circuitry found Still short 3ns pulse –To be done: finishing and debugging of fw – CANbus and monitoring Set of notched fibers, semiautomatic machine in tuning procedure –Set: 3*fibre with 24 notches, creating a line of 72 notches. –3 sets of fibres will be delivered in 1.Q-2012

16 HH - 2011 Dec 13Ivo Polák, FZU, Prague16 Resume QMB1 is in basic operational stage –It is working, no major troubles occurred –First 6 boards (version 1) we have in hand –More work on fw to be done Upgrade of QMB1(v2.0) is foreseen in mid of 2012 Notched fibre semiautomatic machine is hw ready, its sw is under development

17 HH - 2011 Dec 13Ivo Polák, FZU, Prague17 Distribution of light: Notched Fiber Light is emitted from the notches The notch is a special scratch to the fiber, which reflects the light to the opposite direction The size of the notch varies from the beginning to the end of the fiber to maintain homogeneity of the light, which comes from notches First notchMiddle notchEnd position notch Emission from the fiber (side view) Iluminated by Green laser 24 notches

18 HH - 2011 Dec 13Ivo Polák, FZU, Prague18 Mechanical layout of QMB1 Outer line: 30 (29) x 140 mm*2 4 mounting holes for M2.5 screw LED


Download ppt "HH - 2011 Dec 13Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1."

Similar presentations


Ads by Google