Clean Agent Fire Suppression Alternatives

Slides:



Advertisements
Similar presentations
Presentation On INERGEN
Advertisements

Inert Gas Purification Systems
KURSUS PENGENALAN KEPADA PERKHIDMATAN MEKANIKAL DALAM BANGUNAN
Designed for the UK climate come rain or shine.
CO2 CascadeComp_Studi Galileo  1 Semi-Hermetic Compressors for CO 2 Cascade Systems Hermann Renz Bitzer Kuehlmaschinenbau GmbH  Germany.
A new opportunity from 3M 3M™ Novec™ 1230 Fire Protection Fluid Sustainable technology for special hazards A new opportunity from 3M Today, I.
Installation of New CHP system at the Old Aberdeen Campus.
Halon Systems Ch. 5, pages HALogenated hydrocarbON not the same as halogen F, Cl, Br, I 1940’s ’s extremely effective.
© Siemens Industry, Inc Confidential / Drive Your Business Forward Ignite the Power of New Products and Partnerships Siemens Fire Partner Summit.
Viking TotalPac2 FireFlex Dual / 1230
Local Application Total Flooding System: (NFPA 12) A system consisting of a supply of carbon dioxide arranged to discharge into, and fill to the proper.
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
Stages of Fire Detections and Extinguishants From Ginge-Kerr Danmark A/s & BMTT Corporation S/B (www. ginge-kerr.com)
Total Flooding Systems
U N C L A S S I F I E D Operated by the Los Alamos National Security, LLC for the DOE/NNSA Alternative approach to fire suppression – Class A, B, & C fires.
The Greening of the Rooftop Module 2 Basic Principles of Green Design.
In today’s global business environment, the need for clean agent fire suppression has never been greater. Pem All.
WATER FOR FIRE PROTECTION (Chapter 26) Basic factors of fire – Rapid oxidation of combustible materials – A combination of oxygen, fuel, and heat is required.
Ozone is made of three oxygen atoms - O 3 Ozone. OZONE – A Greenhouse gas Greenhouse gas. Near ground it is a nasty pollution In the stratosphere it protects.
EnE 301: ENVIRONMENTAL ENGINEERING 3.0 Air Pollution and Control 3.1 Physical and Chemical Fundamentals 3.2 Major Air Pollutants and their Effects 3.3.
LNG Hazards.
3.2.2 Student Book © 2004 Propane Education & Research CouncilPage Performing DOT Cylinder Evacuation and Vapor Flaring Operations Before DOT cylinder.
Fire Suppression Systems Association PRESENTS:
WELCOME The Fixed Fire Suppression Systems. We carry out the supply installation & Annual required maintenance in regard to the fixed.
1. Questions How do resource use (energy+ water) and CO2 emissions compare in 9 cities across the U.S for 1 average swimming pool? Evaluation of potential.
Inert Gas Fire Extinguishants
Kidde Engineered Fire Suppression System 25 bar Equipment Hardware Engineered for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Investigating Wildfire Extinguishing Methods Helen Stritzel, Carmen Plowman, Juan Torres, Weiliang Sun, Grant Matthews.
CXS490 Chemical Extinguishing System Halocarbon Extinguishing System
Domestic Natural Gas Installations Marc Billington.
SINORIXTM CDT Product Presentation.
NEXT GENERATION Kidde Engineered Fire Suppression System Designed for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Novec 1230™ SYSTEM DESIGN 3M™ Novec 1230™ Fire Protection Fluid.
Respiratory Protection
© 2008 Delmar, Cengage Learning Portable Fire Extinguishers Chapter 11.
Argonite Fire Extinguishing System
Gas volume measurement Benedict Roth Spirometer Vitalograph Dry gas meter Wright respirometer (calibration inaccurate if used for continuous flow)
JE / RA 29/1/021 RAL Evaporative Cooling UK-V Meeting, RAL Wednesday 30th January Julia Easton Talk given by Richard Apsimon.
CXS490 Carbon Dioxide Systems
ALTERNATIVE AGENT UPDATE Louise C. Speitel Fire Safety Branch AAR-440 FAA W.J. Hughes Technical Center Atlantic City International Airport, NJ
3M™ Novec 1230™ Fire Protection Fluid
1 CXS490 - Characteristic of Fire. 2 Other Resources NFPA Standards (available through Seneca Libraries Link NFPA Handbook Manufacturer’s Technical Information.
To be effective an extinguisher: Must be readily accessible In working order Suitable for the hazard Large enough to control the size fire Must be readily.
Federal Aviation Administration Handheld Advisory Circular Update Louise Speitel Fire Safety Branch FAA Wm. J. Hughes Technical Center Atlantic City International.
Unit 4: General Safety Practices
In the 1970’s, scientists discovered the dangerous impact that CFC’s have in the Earth’s atmosphere. They were destroying the ozone layer which protects.
FIRE CONTROL State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
FIRE SERVICES AT DATA CENTRE
1 CXS490 - Pre-Engineered Fire Protection Systems Off-Road Vehicle Systems.
Kidde FM-200® Product Review
NOVEC Fire Suppression System
Toxics Use Reduction Institute Tools for Substitution How to find an alternative cleaning product that will work for you – both for performance and safety.
2012 Lik Kai Pacific Sense March PACIFIC SENSE Company Intro.
Pre-Shift Examination Scenario Continuous Miner Section What you will need to complete this exercise: Pencil and paper to take notes or perform calculations.
Volume and Moles. Avogadro’s Law  When the number of moles of gas is doubled (at constant temperature and pressure, the volume doubles.  The volume.
What volume will 1 mole of a gas occupy at STP? STP = 273K, 1.013x10 5 Pa One mole of any ideal gas occupies a volume of 22.4L at STP.
CGA Conference October, 2003 Update on G-4.4, Industrial Practices of Gaseous Oxygen Transmission and Distribution Piping System.
R.G.W. Cherry & Associates Limited #1 INTERNATIONAL AIRCRAFT SYSTEMS FIRE PROTECTION WORKING GROUP MEETING AN INTEGRATED FIRE PROTECTION SYSTEM.
Basic Refrigeration. Star Refrigeration Wednesday 12 September 2007.
Welcome to Fire Eater Conference on Fire Safety & Health :20 Active Gas Extinguishing Systems. Torbjørn Laursen.
Carbon Dioxide System Design
ODS & SGG Considerations for Changing a System
Presented by.
Pre-Engineered Novec 1230 & FM-200 March 1, 2012
General Safety Practices
“ Highlighting the risks and challenges presented by modern data-center cooling systems in fire detection and suppression applications. “ Dave Boyack Sales.
Some Facts about Welding Cable
Matt Bower DWQR Risk Assessment Training 2018
Portable Fire Extinguisher Overview
Presentation transcript:

Clean Agent Fire Suppression Alternatives April 19, 2017 Clean Agent Fire Suppression Alternatives IG55 Comparison Novec1230

Which System Is The Best ? April 19, 2017 Inert Gas? Synthetic? H20? Which System Is The Best ?

Fire Suppression Agent Comparison April 19, 2017 Inert IG55 Inergen IG541 Synthetic HFC227ea Novec1230 HFC125 Fire Suppression Agent Comparison

ENVIRONMENT Although these figures represent the agent itself, it does not take into account the GWP of the manufacturing of the cylinders OZONE DEPLETION FACTOR GLOBAL WARMING POTENTIAL ATMOSPHERIC LIFE TIME CO2 n.a. Inergen IG-55 Novec1230 1 0,014 years (5 days) FM-200 3500 33 years

Extinguishing Capability April 19, 2017 Extinguishing Capability A, B, C (E) DANGEROUS/Toxic How? - OXYGEN Reduction C02 – 50-% How? - HEAT Removal FM200 (7.9% - 8.5%) Novec123 (5.3% - 5.6%) 12% - 14% Inergen/IG55 NOT Suitable for occupied spaces Suitable for occupied spaces * not effective on ... class A deep seated fires chemicals containing their own supply of oxygen (cellulose nitrate) chemicals capable of auto-thermal decomposition Suitable for occupied spaces

Human Safety % NOAEL - No observable adverse effect level April 19, 2017 Human Safety % Design Concentration* NOAEL LOAEL Novec1230 4,2% - 5,9% 10% >10% FM-200® 6,4% - 9,0% 9% 10,5% Inergen® 34,2% - 41,2% 43% 52% IG-55 40,3% - 47,5% CO2 35% - 65% 5% n.a. NOAEL - No observable adverse effect level LOAEL - lowest-observed-adverse-effect-level

Fire Suppression Decision Factors April 19, 2017 Environment Budget Space Safety Fire Suppression Decision Factors

Distribution Pipe Pipe length and complexity of the pipe run FM-200® April 19, 2017 Distribution Pipe Pipe length and complexity of the pipe run Very Good Good Fair Poor FM-200® Novec™ 1230 CO2 Inergen® and IG55 Pipe length The length of the bar does not give absolute ratios, it is a general indication only. The width of the bar refers to the possible complexity of the pipe run (indication only).

Working Pressures FM-200® Navec1230™ CO2 Inergen® IG55* 20 25 40 60 80 April 19, 2017 Working Pressures FM-200® Navec1230™ CO2 Inergen® IG55* 20 25 40 60 80 100 120 Constant Flow * * 200/300 Bar Constant Flow Pipe pressure (bar) The installer must ensure the correct pressure rating for pipes and fittings acc. to the flow calculation result. * Pipe pressure downstream the pressure reducing unit. ** The final peak pressure in the pipe will result from the hydraulic flow calculation.

Cylinder Foot Print Comparison for a 200 m³ class A hazard April 19, 2017 Cylinder Foot Print Comparison for a 200 m³ class A hazard FM-200®: 7,9% = 0,63 kg/m³ 126 kg - 1 x 147 ltr. Novec™1230: 5,3% = 0,78 kg/m³ 156 kg - 1 x 180 ltr. Inergen®: 39,9% = 0,51 m³/m³ 102 m³ - 5 x 80 ltr. (300 bar) CO2: 50% = 1,30 kg/m³ 260 kg - 6 x 50 kg IG55/Inergen®: 39,9% = 0,51 m³/m³ 102 m³ - 7 x 80 ltr. (200 bar) 102 m³ - 5 x 80 ltr. (300 bar)

Installation Time & Complexity April 19, 2017 Installation Time & Complexity FM200/Novec1230 Co2 Inergen, IG55 Pipe Work Time of Installation and Complexity of installation FM200 and Novec1230 demand less space and less pipe work. Inert Gas cylinders can often be more complicated with larger foot prints and more pipe work

The Question? . Q :- So what is The Best Fire Suppression Agent? April 19, 2017 Nocec1230 FM200 Inert Gas Q :- So what is The Best Fire Suppression Agent? A :- Generally, there is no Best system! Many factors finally lead to the decision for a certain system .. .

Decision Factors Which fire class? Which system approval is required? April 19, 2017 What type of application Total Flooding Which fire class? Which system approval is required? Single hazard or multiple hazards Available space for Cylinders Special requirements from insurance Local application Health and safety Decision Factors