Pumping Apparatus Driver/Operator

Slides:



Advertisements
Similar presentations
Sprinkler Systems and Standpipe Operations
Advertisements

Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Fire Apparatus Pump Theory
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use various hose appliances and tools, prepare a test site for service.
Adapted From Cody Fire School Presentations Amsterdam Fire Regular Fire Training February 16, 2009.
CAFS On-Line Orientation
Tandem Pumping Video. INITIAL SIZE-UP When approaching the structure note the location of the FDC, Hydrant and Building Access.

Augmenting Fire Standpipe Systems
For The Driver Operator
Experiment 8 : Minor Losses
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
Driver Recert 2012 Topics Update on Fire Hose Friction Loss Coefficients Fire Flow Through Long LDH Supply Lines Rural Water Supply Flow Rates Booster.
LoneStar Fire Specialties
Pumping Apparatus Driver/Operator
CVFD Training – Water Supply SFFMA Training Objectives: –
HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE TRAINING FACILITY.
Fire Streams SFFMA Training Objectives: –
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
Pumping Apparatus Driver/Operator
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
Water Supply.
Pumping Apparatus Driver/Operator
Pumper Operations n Why do we need to be concerned about being good pump operators? n When we are good pump operators the personnel working the hand lines.
Pumping Apparatus Driver/Operator
Chapter 9 Water Supply.
NOTRE DAME FIRE SCHOOL 2004 FIRE PUMPS 101 CAPTAIN TROY KERCKHOVE SOUTH BEND FIRE.
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
C L A S #4 Driver Operator Refresher Training.
Task Force-7 Engine 14 Engine 13 Batt. 2
Intermediate SFFMA Objectives: – Hrs received.
Rapid Intervention Team & MAYDAY Procedures
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Water Supply.
Instructor Lee Lautzenheiser
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
HVAC523 Basic Subsystems.
CHAPTER 9 Copyright © 2007 Thomson Delmar Learning 9.1 Water Supply.
Pumping Apparatus Driver/Operator
Pumping Apparatus Driver/Operator
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
Water Supply Firefighter II.
Fire Service Pump Operator - 10 Water Supply.
Pumping Apparatus Driver/Operator — Lesson 1 Pumping Apparatus Driver/Operator Handbook, 2 nd Edition Chapter 1 — The Driver/Operator.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
Mahoney, Hannig, Fire Department Hydraulics, 2nd Ed. ©2009 by Pearson Education, Inc., Upper Saddle River, NJ Fire Department Hydraulics Chapter 8 Required.
TANKER OPERATIONS Long Laneway – 1 st arriving pumper P-1 FIRE BLDG House?= 38mm x2 + 65mm backup line Barn? = consider 2- 65mm right away Lay a Hi-Vol.
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
Firefighter III Module B Water Supply (4-19) (4-19)
Achieving Maximum Flows The Water Triangle.... The FIRE Tetrahedron.
Pumping Apparatus Driver/Operator — Lesson 1 Pumping Apparatus Driver/Operator Handbook, 2 nd Edition Chapter 1 — The Driver/Operator.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Fire Pump Theory Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
 All fire pumps are rated by drafting through 20 ft. of hose with 10 ft. of Lift  Theoretical Lift = 14.7 psi x 2.3 ft/psi = 33.8 ft.  Maximum practical.
Water Shuttle Operations
Snohomish County Training Officers 2013Q3. Drafting Need for drafting operations Set up and resource considerations Shuttle operations Jet Siphon Operations.
Relay Pumping Operations Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Fire Hose Nozzles & Flow Rates
Operating Fire Pumps Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
CENTIFUGAL PUMP OPERATION
Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine.
2013Q1.
Essentials of Fire Fighting
Pumping Apparatus Driver/Operator — Lesson 1
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

Pumping Apparatus Driver/Operator — Lesson 13 Pumping Apparatus Driver/Operator Handbook, 2nd Edition Chapter 13 — Relay Pumping Operations

Pumping Apparatus Driver/Operator Learning Objectives 1. Distinguish among characteristics of units in a relay pumping operation. 2. Distinguish among characteristics of hose and pump appliances that may be used to assist with relay pumping operations. 3. List operational considerations for relay pumping. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Learning Objectives 4. List ways to increase the amount of flow through a relay. 5. List the four steps of a basic relay pumping operation. 6. Answer questions about the maximum distance relay method. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Learning Objectives 7. State the equation for calculating the number of pumpers needed to relay a given amount of water. 8. Calculate the number of pumpers needed to relay a given amount of water. 9. Describe the constant pressure relay method. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Learning Objectives 10. Select from a list advantages of using the constant pressure relay method. 11. List instances in which pressure may be modified in a constant pressure relay. 12. Explain how relay pressure is increased or decreased. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Learning Objectives 13. Operate in a constant pressure relay. 14. Select facts about putting a relay into operation. 15. Answer questions about operating and shutting down the relay. 16. Use a flowchart to troubleshoot relay pumping operations. Pumping Apparatus Driver/Operator

Units in a Relay Pumping Operation Source pumper Relay pumper Attack pumper Hose tenders Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Source Pumper Also called the supply pumper The pumper connected to the water supply at the beginning of the relay operation Should be the engine with the largest pumping capacity Pumps water to the next apparatus in line Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Relay Pumper Also referred to as the in-line pumper A pumper connected within the relay that Receives water from the source pumper or other relay pumper, Boosts the pressure, and then Supplies water to the next apparatus in the relay Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Attack Pumper An engine or other pumping apparatus located at the fire scene that will be receiving water from the relay and supplying attack lines and appliances as needed for fire suppression Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Hose Tenders May assist in the long hose lays associated with relay pumping operations May or may not be equipped with a fire pump that allows them to participate in the pumping operation once the hose is laid Usually carry a mile (1.6 m) or more of large diameter (4-inch [100 mm] or larger) hose Pumping Apparatus Driver/Operator

Units in a Relay Pumping Operation Pumping Apparatus Driver/Operator

Appliances that May Assist with Relay Pumping Operations Large diameter hose (LDH) — Ranges in size from 3½ to 12 inches (90 mm to 300 mm) Intake pressure relief valves Intended to enhance firefighter safety Reduce possibility of damage to pump and discharge hoselines caused by water hammer (Continued) Pumping Apparatus Driver/Operator

Appliances that May Assist with Relay Pumping Operations Intake pressure relief valves (cont.) Are of two types Supplied by the pump manufacturer and an integral part of the pump intake manifold Add-on device screwed onto the pump intake connection (Continued) Pumping Apparatus Driver/Operator

Appliances that May Assist with Relay Pumping Operations Intake pressure relief valves (cont.) Are sometimes preset to allow a predetermined amount of pressure into the fire pump; if the incoming pressure exceeds preset level, the valve dumps excess pressure/water until the water entering the pump is at the preset level (Continued) Pumping Apparatus Driver/Operator

Appliances that May Assist with Relay Pumping Operations Intake pressure relief valves (cont.) May be equipped with a manual shut-off valve (Continued) Pumping Apparatus Driver/Operator

Appliances that May Assist with Relay Pumping Operations Bleeder valves on intake pressure relief valve Allow air to be bled off as the incoming supply hose is charged May be located directly on the intake piping to the pump itself (Continued) Pumping Apparatus Driver/Operator

Appliances that May Assist with Relay Pumping Operations In-line relay valves Are placed in the relay line for incoming pumpers Allow late-arriving pumpers to hook up after the relay is operating and boost the pressure (and corresponding volume) without interrupting the relay operation (Continued) Pumping Apparatus Driver/Operator

Appliances that May Assist with Relay Pumping Operations In-line relay valves (cont.) (Continued) Pumping Apparatus Driver/Operator

Appliances that May Assist with Relay Pumping Operations Discharge manifold Is used if an LDH relay pumping operation is intended to support more than one attack pumper at the fire scene (Continued) Pumping Apparatus Driver/Operator

Appliances that May Assist with Relay Pumping Operations Discharge manifold (cont.) Is used to break down LDH into two or more hoselines that may then be connected to attack pumpers Pumping Apparatus Driver/Operator

Operational Considerations for Relay Pumping Amount of water required at the emergency scene In some cases, the relay must supply the total water necessary to complete the fire fighting operation. In other cases, the relay is used to supplement an inadequate municipal water supply system. (Continued) Pumping Apparatus Driver/Operator

Operational Considerations for Relay Pumping Distance from emergency scene to water source A longer relay distance needs more hose. More hose means more friction loss. To increase amount of flow through relay, Increase size or number of hoselines, or Increase pump discharge pressure, or Increase number of pumpers in relay Pumping Apparatus Driver/Operator

Steps of a Basic Relay Pumping Operation 1 — The incident commander determines that it is necessary to use a relay to provide an adequate amount of water to the scene. 2 — The dispatch center is ordered to send a relay task force or strike team. (Continued) Pumping Apparatus Driver/Operator

Steps of a Basic Relay Pumping Operation 3 — Three to five pumpers, each with large capacity fire pumps and usually LDH, are dispatched to the scene. 4 — Pumpers set up the water supply independent of the companies already operating on the scene. Pumping Apparatus Driver/Operator

Maximum Distance Relay Method Involves flowing a predetermined volume of water for the maximum distance that it can be pumped through a particular hose lay By using Table 13.1 or 13.2 on page 402 of the manual, the driver/operator can determine the distance that a certain flow may be pumped through the type of hose carried on the apparatus. (Continued) Pumping Apparatus Driver/Operator

Maximum Distance Relay Method All fire department pumpers are rated to flow: 100% of their maximum volume at 150 psi (1 000 kPa) 70% of their maximum volume at 200 psi (1 350 kPa) 50% of their maximum volume at 250 psi (1 700 kPa) (Continued) Pumping Apparatus Driver/Operator

Maximum Distance Relay Method Using the figures in Tables 13.1 and 13.2, the number of pumpers needed to relay a given amount of water can be determined by using the following formula: Relay distance Given distance Note: Always round up to the nearest whole number. For example, if the answer is 3.2, you actually need 4 pumpers. + 1 = total number of pumpers needed Pumping Apparatus Driver/Operator

Constant Pressure Relay Method Provides the maximum flow available from a particular relay setup by using a constant pressure in the system Depends on a consistent flow being provided on the fireground Pumping Apparatus Driver/Operator

Advantages of a Constant Pressure Relay Method Speeds relay activation Requires no complicated calculations at the emergency scene Reduces radio traffic and confusion between pump operators (Continued) Pumping Apparatus Driver/Operator

Advantages of a Constant Pressure Relay Method The attack pumper driver/operator is able to govern fire lines easier. Operators in the relay only have to guide and adjust pressure to one constant figure. Pumping Apparatus Driver/Operator

When Pressure May be Modified in a Constant Pressure Relay Variations in relay pumper spacing Extreme elevation differences between source and fire Increases in needed fire flow Large diameter hose Pumping Apparatus Driver/Operator

Increasing the Relay Pressure in a Constant Pressure Relay The source pumper is adjusted until the desired pressure is reached. Each successive pumper is similarly adjusted. Pumping Apparatus Driver/Operator

Decreasing the Relay Pressure in a Constant Pressure Relay The attack pumper throttles down. The source pumper discharges its dump line back into the water supply source. The relay pumpers throttle down to the desired pressure, successively from the water source. Pumping Apparatus Driver/Operator

Putting a Relay into Operation A relay pumping operation always begins with the source pumper, which should be the largest capacity pumper. If the relay is being supplied from draft, the source pumper will have to develop a higher net pump discharge pressure than the other pumpers in the relay. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation Once the water supply has been established, the source pumper opens an uncapped discharge or allows water to waste through a dump line until the first relay pumper is ready for water. Failure to keep water moving through the pump could result in a loss of prime, thus delaying the operation. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation The relay pumper should be waiting for water with the dump line or discharge open and the pump out of gear. When both the source pumper and the relay pumper are ready, the discharge supplying the hoseline on the source pumper is opened while the valve on the dump line is closed in a coordinated action. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation The discharge to the supply line must be opened slowly to prevent a sudden discharge into the empty hoseline that could cause the pump to lose prime if pumping from draft. The water then begins to move from the source pumper to the relay pumper. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation As the water fills the line, the air will be forced through the pump and out the open dump line of the relay pumper. When water comes out of the dump line, the pump on the relay pumper can be engaged. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation If the waiting period for receiving water from the source pumper or other relay pumper is only going to be a few minutes, the pump on the waiting pumper may be engaged before receiving the water. Another option is to start the relay, or fill the hoselines, with water from the apparatus water tank. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation It is most desirable to maintain an intake pressure of 20 to 30 psi (150 kPa to 200 kPa). If the relay pumper is receiving an intake pressure greater than 50 psi (350 kPa), the valve to the dump line on the relay pumper must be adjusted to limit the residual to the 50 psi (350 kPa) maximum. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation The pump discharge pressure increases as the throttle setting on the relay pumper is increased; therefore, the valve to the dump line will have to be gated down to maintain the 50 psi (350 kPa) residual pressure. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation Once the pump discharge pressure on the relay pumper has reached the desired pressure with water being discharged, this portion of the relay has been established and no further adjustments should be necessary. When the next relay pumper is ready for water, the same procedure will be followed. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation When water reaches the attack pumper, the operator should bleed out the air from the supply line by opening the bleeder valve on the intake being used. The intake valve on the attack pumper can then be opened and a water supply established through the relay. (Continued) Pumping Apparatus Driver/Operator

Putting a Relay into Operation There is a need for dump line on the attack pumper as well. When one of the attack lines is shut down, an alert operator can open the dump line to allow water to flow, thus preventing a dangerous pressure buildup in the relay. Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Operating the Relay Once the relay is in operation and the water is moving, all pump operators set their automatic pressure control devices to an appropriate level. If equipped with newest and most sensitive governors, the attack pumper should be set in the “pressure” mode while all others in the relay should be set in the “RPM” mode. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Operating the Relay If the pumper is equipped with an intake relief valve, it should be put in service by taking off any caps on the outlet or by opening any valve associated with it. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Operating the Relay If the valve is readily adjustable, it should be set to discharge at 10 psi (70 kPa) above the static pressure of the water system it is attached to or 10 psi (70 kPa) above the discharge pressure of the previous pumper in the relay. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Operating the Relay At no time should the relief valve be set for a higher amount than the safe working pressure of the hose. If the attack pumper is equipped with a readily adjustable intake relief valve, set it between 50 to 75 psi (350 kPa to 525 kPa) to establish a stable operating condition for the attack pumper. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Operating the Relay Small variations in pressure are not significant and no attempt should be made to maintain exact pressures. As long as the intake pressure does not drop below 10 psi (70 kPa) or increase above 100 psi (700 kPa), no action should be required. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Operating the Relay Radios must be used cautiously at a relay operation. Too much radio traffic when setting up a relay can interfere with fireground communications and impede efforts to establish the water supply. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Operating the Relay When pumpers are within site of each other, hand signals can be used. Where additional radio frequencies are available, one channel should be dedicated to coordination of the water supply operation. Pumping Apparatus Driver/Operator

Shutting Down the Relay Shut down from the fire scene first. Starting with the attack pumper and coordinating with the other pumpers in the relay, slowly decrease the throttle, open the dump line, and take the pump out of gear. Drain hose and ready for reloading. Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Summary In areas not served by municipal or other pressurized water supply systems, fire departments must provide water for fire fighting in some other way. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Summary In some cases, water can be supplied by water tenders. In other cases, especially where large structures are at risk, fire departments may choose to supply water through relay pumping operations from the nearest adequate water source. (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Summary As with any other critical operation, fire departments that expect to use relay pumping should periodically reinforce these tactics with realistic training exercises that include all other nearby entities that may be needed in relay pumping operations during actual emergencies. Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Discussion Questions 1. What is a source pumper? 2. What is a relay pumper? 3. What is an attack pumper? 4. What are hose tenders? (Continued) Pumping Apparatus Driver/Operator

Pumping Apparatus Driver/Operator Discussion Questions 5. How can you increase the amount of flow through a relay? 6. List the four steps of a basic relay pumping operation. 7. What is the equation for calculating the number of pumpers needed to relay a given amount of water? 8. What are some of the advantages of the constant pressure relay method? Pumping Apparatus Driver/Operator