Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.

Slides:



Advertisements
Similar presentations
PV String Monitoring Solution
Advertisements

سیستم آلارم دیجیتالی مجهز به ثبات خطا
Vehicle Tracking Remote Control & Monitoring System.
Supervisory Control & Data Acquisition DAQ Networking.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
Computing Machinery Chapter 10: Microcontrollers.
Multi Instruments Data Acquisition Software Evolution
Introduction of Holtek HT-46 series MCU
EUT 1040 Lecture 10: Programmable Logic Controllers.
STARLight PDR 3 Oct ‘01I.1 Miller STARLight Control Module Design Ryan Miller STARLight Electrical Engineer (734)
Remote Aquarium Monitor and Control System Christopher Bunk Joshua Hoiland.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Objectives: Sampling of analog signal. Act as analyzer and terminal for pc. Project supervised by: Michael Gandelsman Project performed by: Roman Paleria,
1 Project supervised by: Dr Michael Gandelsman Project performed by: Roman Paleria, Avi Yona 26/4/2004 Multi-channel Data Acquisition System Final_A Presentation.
The Technion Israeli Institute of Technology Intel Inc. A cooperation of:
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Dataloggers. Records voltage, current, or circuit closing Environmental variables must be converted to electronic signal.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
MIG II DIGITAL FEEDER PROTECTION
CALPORT 300 Three-Phase Portable Reference Standard
Chapter 6 Voltage Regulators - Part 2-.
USART Communication using the RS standard ETEC6416.
G650 Generator Protection & Control System
Computers in Surveying SVY2301 / E4006 Automated Surveying.
Geodetic Research Laboratory Department of Geodesy and Geomatics Engineering University of New Brunswick 22/02/02 Stefan.Duerauer DIPLOMA THESIS Prototype.
Viking Pump Flow Manager - Phase 2 Senior Design May
Arctic Control Introduction V 1.0. Arctic Control The Arctic Control is a device with integrated wireless communications for controlling medium-voltage.
Looking for a more powerful circuit monitor?
FG Wilson Access 4000 Control Panel
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
POWER PLANT USED IN TELECOM
Copyright 2001 ACS-Tech80 1 ACS-Tech 80, Inc. SPiiPlus Control Module Overview.
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
Need to enhance your network?
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
European Organization for Nuclear Research Geneva - Switzerland Ing. Robert van der Vlugt CERN/PH Alice Detector Control System PVSS2 General Purpose Interface.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
STYLITIS-50 Most advanced datalogger for wind energy assessment.
K.C.RAVINDRAN,GRAPES-3 EXPERIMENT,OOTY 1 Development of fast electronics for the GRAPES-3 experiment at Ooty K.C. RAVINDRAN On Behalf of GRAPES-3 Collaboration.
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
Power Probe The PSP Power Probe is a three phase data logger, quality of supply monitor, and remote terminal unit for demand-side- management. Historical.
Data Logging Solution for Digital Signal Processors Brian Newberry Nekton Research, Inc. James M. Conrad University of North.
Senior Design Project “ MP3 Player ” Brian P. Allen Zeeshan A. Khan Jerry T. Koshy.
STYLITIS-41 … is suitable for measurements in Meteorological, Wind/Hydro potential and other Environmental fields.
Aerospace Digital Communication Instrument Senior Design 1 Presentation.
INTRODUCTION TO FBD - Function Block Diagram by ( LOGO ) Revision 2.
Aerospace Digital Communication Instrument Senior Design Presentation.
Hardware Introduction – Standard vs Q.i
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
New product introduction:
World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Autoflame Training,
A commercially available digitization system Fotiou Andreas Andreas Fotiou.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
New digital readout of HFRAMDON neutron counters Proposal Version 2.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Lecture 10: Programmable Logic Controllers
A transformer is a complex protective object
FEEDER PROTECTION UNIT
SIO-RTD RTD MODULE.
Zigbee Networks Using Xbee Modules
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Vibration Monitoring System M14
Series 5300 Lithium Cell Formation System
EUT 1040 Lecture 10: Programmable Logic Controllers Unrestricted.
Simple, accurate tenant sub-metering
Presentation transcript:

Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically records non-zero values to internal nonvolatile memory for further data transfer to PC. Features Input Pulse frequency up to 20Hz with digital filtering for debouncing cancelation Isolated input for Reed Switch or Voltage Pulse Selectable Recording Period (beginning from 1s with 1s step) Nonvolatile memory for data storage: a)FRAM (2Mbit for records) b)microSD card optionally (up to 2Gbit) Interface with PC for remote data reading: a)Isolated RS-485 interface with selectable Baud Rate up to baud/s b)Optional GSM/GPRS communication (TCP/IP) Data archiving and visualization on the PC +5…12VDC power supply Package for DIN rail mounting Operating temperature range -25…+75 ℃

Data Logger connection to Meter and PC RS-485 Bus length up to 1 km Selectable baud rate up to baud/s Virtual COM port GSM/GPRS No wires, no distance limitation Onboard SIM card with connection to mobile Internet TCP/IP communication protocol

Block diagram of the Data Logger

Input Circuit Digital anti debouncing filtering algorithm is implemented in MCU program. Minimal pulse width is limited at 25ms, that allows pulse rate up to 20Hz. Pulse Input accepts Reed Switch and Voltage Pulses (up to 36V). See figures on the left for more info. Input Circuit protection against reverse polarity of the signal. IN+ IN- GND +5V Pulse MCU Pulse In +5V GND

Operation principles Recording Period is designated as T on the time diagram above. When this interval expires, non-zero value of the Pulse Counter with time stamp (seconds, minutes, hours, days, weekdays, months, years) are written to the nonvolatile memory. Then Pulse Counter is cleared to start counting pulses for the next recording period. Recording period selectable from 1s with 1s step. 20-bit Pulse Counter is used for counting pulses.

PC software. Setup and configuration. Configuration of the virtual COM port Setting and reading parameters Main window

Data visualization. Table and chart formats. Daily water consumption in March Data Logger records In March Data archiving on the PC

Data export to Excel Detailed data representation for short time interval The same data, but current value is added to the sum of previous values. The last value is equal to total water consumption for selected time interval.