Hiroyasu Tajima Stanford Linear Accelerator Center Nov 3–8, 2002 VERTEX2002, Kailua-Kona, Hawaii Gamma-ray Polarimetry ~ Astrophysics Application ~

Slides:



Advertisements
Similar presentations
Advanced GAmma Tracking Array
Advertisements

Evolving X-ray Polarimetry towards high energy and solar science Sergio Fabiani Università degli Studi di Roma “Tor Vergata” INAF / IAPS I A P S Istituto.
1 T. Mizuno et al. August 23, 2014 HEAPA Symposium on Future T. Mizuno (Hiroshima Univ.) on behalf of the SGD team and Polarization team.
IEEE_2007Nov.ppt Tsunefumi Mizuno 1 High Sensitivity Balloon-Borne Hard X-Ray/Soft Gamma-Ray Polarimeter PoGOLite November 2 nd, 2007 IEEE Nuclear Science.
Detection of Gamma-Rays and Energetic Particles
Space Applications of Geant4 Polarized Processes F.Longo + G.Depaola * + University of Ferrara and INFN (Italia) * National University of Córdoba (Argentina)
Astro-E2 and Japanese future space programs for high energy astrophysics Astro-E2 NeXT XEUS Small satellite programs Tadayasu Dotani (ISAS)
A Silicon Disk Tracker in forward direction for STAR News since November 2000 Physics Capabilities capabilities Requirements / Potential Technologies Possible.
1 July 8, 2008SLAC Annual Program ReviewPage Detector R&D at KIPAC Hiro Tajima Kavli Institute for Particle Astrophysics and Cosmology 1.
China’s Future Missions in Space High Energy Astrophysics Shuang Nan Zhang 张双南 Tsinghua University and Institute of High Energy Physics, Chinese Academy.
RESMDD'02 pCT: Hartmut F.-W. Sadrozinski, SCIPP INITIAL STUDIES on PROTON COMPUTED TOMOGRAPHY USING SILICON STRIP DETECTORS L. Johnson, B. Keeney, G. Ross,
Striplet option of Super Belle Silicon Vertex Detector Talk at Joint Super B factory workshop, Honolulu 20 April 2005 T.Tsuboyama.
Sept. 18, 2008SLUO 2008 Annual Meeting Detector R&D at KIPAC Hiro Tajima Kavli InStitute of Particle Astrophysics and Cosmology.
Simulations with MEGAlib Jau-Shian Liang Department of Physics, NTHU / SSL, UCB 2007/05/15.
Science Specification Table 12 keV keV for neutral particles 40.5 cm 2 image plane Electronic Noise 3 keV FWHM Proton Dead Layer
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
The 6th International Workshop on Radiation Imaging Detectors, July 2004, Glasgow Digital X-ray portable scanner based on monolithic semi-insulating.
Silicon Sensor with Readout ASICs for EXAFS Spectroscopy Gianluigi De Geronimo, Paul O’Connor Microelectronics Group, Instrumentation Division, Brookhaven.
X-Ray Polarimetry with Micro Pattern Gas Detectors Nuclear Science Symposium – November 2001 R.Bellazzini - INFN Pisa X-Ray Polarimetry with a Micro.
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
R&T télescope APC1INFIERI meeting – 15 juillet 2014 DSSD detectors development for a space Compton telescope P. Laurent, Y. Dolgorouky, M. Khalil,
Introduction to gamma-ray astronomy GLAST-Large Area Telescope Introduction to GLAST Science New way of studying astrophysics Schedule of GLAST project.
Chevron / Zigzag Pad Designs for Gas Trackers
Hard X and Gamma-ray Polarization: the ultimate dimension (ESA Cosmic Vision ) or the Compton Scattering polarimetery challenges Ezio Caroli,
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193,
Impact parameter resolution study for ILC detector Tomoaki Fujikawa (Tohoku university) ACFA Workshop in Taipei Nov
We report the result of a beam test on a prototype of Astronomical hard X-ray/soft gamma-ray Polarimeter, PoGO (Polarized Gamma-ray Observer). PoGO is.
Instrumental Development in Japan for Future Missions 1.Si strip detectors(GLAST) 2.Supermirror technology 3.New hard-X/  detectors 4.TES calorimeters.
Status report on the Asian Solid State Tracking R&D March 31, 2003 M. Iwasaki University of Tokyo.
Hard X-ray Polarimeter for Small Satellite Design, Feasibility Study, and Ground Experiments K. Hayashida (Osaka University), T. Mihara (RIKEN), S. Gunji,
Development of CCDs for the SXI We have developed 2 different types of CCDs for the SXI in parallel.. *Advantage =>They are successfully employed for current.
Electron Detection for Compton Polarimetry Michael McDonald Outline -Compton Effect -Polarimetry -Detectors -Diamond Results.
Thin Silicon R&D for LC applications D. Bortoletto Purdue University Status report Hybrid Pixel Detectors for LC.
GLAST Large Area Telescope (LAT) Overview Peter F. Michelson Instrument Principal Investigator Stanford University William E.
Observational techniques meeting #15
G. Bertuccio “Challenges in the Design of Front-End Electronics for Semiconductor Radiation Detectors ” 14 th International Workshop on Room Temperature.
Monte Carlo Simulation Study of In-orbit Background for the Soft Gamma-ray Detector onboard ASTRO-H Mizuno T., Hiragi K., Fukazawa Y., Umeki Y. (Hiroshima.
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
Radiation hardness of Monolithic Active Pixel Sensors (MAPS)
MeV Gamma Ray Nuclear Astrophysics Yesterday: Science and Observations
Jonathan BouchetBerkeley School on Collective Dynamics 1 Performance of the Silicon Strip Detector of the STAR Experiment Jonathan Bouchet Subatech STAR.
Event Analysis for the Gamma-ray Large Area Space Telescope Robin Morris, RIACS Johann Cohen-Tanugi SLAC.
Tracking Background GRETINA Software Working Group Meeting September 21-22, 2012, NSCL MSU I-Yang Lee Lawrence Berkeley National Laboratory.
Electron tracking Compton camera NASA/WMAP Science Team  -PIC We report on an improvement on data acquisition for a Time Projection Chamber (TPC) based.
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
WG3 – STRIP R&D ITS - COMSATS P. Riedler, G. Contin, A. Rivetti – WG3 conveners.
Peterson xBSM Optics, Beam Size Calibration1 xBSM Beam Size Calibration Dan Peterson CesrTA general meeting introduction to the optics.
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
Progress with GaAs Pixel Detectors K.M.Smith University of Glasgow Acknowledgements: RD8 & RD19 (CERN Detector R.&D. collaboration) XIMAGE (Aixtron, I.M.C.,
Villa Olmo, Como October 2001F.Giordano1 SiTRD R & D The Silicon-TRD: Beam Test Results M.Brigida a, C.Favuzzi a, P.Fusco a, F.Gargano a, N.Giglietto.
ICT 1 SINTEF Edge-On Sensor with Active Edge Fabricated by 3D-Technology T. E. Hansen 1), N. Ahmed 1), A. Ferber 2) 1) SINTEF MiNaLab 2) SINTEF Optical.
Hiroyasu Tajima Stanford Linear Accelerator Center Kavli Institute for Particle Astrophysics and Cosmology October 26, 2006 GLAST lunch Particle Acceleration.
RD program on hybrids & Interconnects Background & motivation At sLHC the luminosity will increase by a factor 10 The physics requirement on the tracker.
The digital TPC: the ultimate resolution P. Colas GridPix: integrated Timepix chips with a Micromegas mesh.
Zhanshan Wang Institute of Precision Optical Engineering (IPOE) School of Physics Science and Engineering Tongji University, Shanghai , China Soft.
FCAL Krakow meeting, 6. May LumiCal concept including the tracker R. Ingbir, P.Růžička, V. Vrba.
Hiroyasu Tajima Stanford Linear Accelerator Center May 5, 2005 SLAC GLAST lunch talk Development of Next Generation Compton Gamma-ray Telescope.
CEA DSM Irfu IDeF-X HD Imaging Detector Front-end for X-ray with High Dynamic range Alicja Michalowska, CEA-IRFU 1 Journées VLSI June 2010.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
MOHAMAD KHALIL APC LABORATORY PARIS 17/06/2013 DSSD and SSD Simulation with Silvaco.
Progress with GaAs Pixel Detectors
WPOL Wide field camera with POLarimetry
E > 100 keV activities at DTU Space ½ MeV Telescope Design
Detector R&D in KAPAC Outline Compton Camera SOI detector
Status of CCD Vertex Detector R&D for GLC
Why silicon detectors? Main characteristics of silicon detectors:
Presentation transcript:

Hiroyasu Tajima Stanford Linear Accelerator Center Nov 3–8, 2002 VERTEX2002, Kailua-Kona, Hawaii Gamma-ray Polarimetry ~ Astrophysics Application ~

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Outline Introduction. Concepts. Key features (requirements.) Instrument description.  Silicon Strip Detector System. Double-sided SSD. Low noise front-end VLSI. Results.  Noise performance.  Energy resolution. Conclusions and future prospects.

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Polarization in Astrophysics Gamma-ray is excellent probe to study particle acceleration mechanism in BHs and pulsars. Polarization is important parameter to understand gamma-ray production mechanism.  Inverse Compton Scattering. Polarization depends on scattering angle. Geometrical information.  Synchrotron Radiation. Polarization is perpendicular to magnetic field direction.

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Soft Gamma-ray (X-ray) Imaging Coded mask Compton telescope X-ray mirror Well-type Phoswich

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Polarization Measurement Photoelectric absorption Compton Scattering  Polarization depends on scattering angle, photon energy. e EE EE E’  Polarization vector

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Polarimetry with Micro Pattern Gas Detectors R. Bellazzini, INFN Pisa

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Analyzing Power 5.9 keV unpolarized5.4 keV polarized Analyzing power = (C max  C max )/(C max  C max ) ~ 50% C max C min

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Multiple Compton Technique Proposed by T. Kamae et al  E1E1 E3E3 E2E2 11 22

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Key Features (Requirements) High energy resolution: ~ 1 keV (FWHM).  High angular resolution: ~ 1 o (FWHM).  High background rejection. Constraints from Compton kinematics Polarimetry. Large Field-of-View: > 2 sr. Wide energy band: 0.05–20 MeV. Low weight.  No heavy calorimeter. ~ 120 e – (RMS)

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Angular Resolution Doppler broadening will limit ultimate angular resolution.

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Source Localization

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 With 10X Better Resolution…

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Semiconductor Multiple-Compton Telescope photo- absorption Compton Scattering pair- creation Si Detector CdTe Detector Si CdTe Doppler broadening is much smaller in Si.

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Collaboration Hiroyasu Tajima, T. Kamae Stanford Linear Accelerator Center T. Takahashi, K. Nakazawa Institute of Space and Astronautical Science Y. Fukazawa Hiroshima University M. Nomachi Osaka University

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Performance Si is essential for wide energy band. 25cm 80 layers 80 layers of 0.5 mm thick Si and CdTe Takahashi (ISAS) Si CdTe

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Compton Kinematics Background suppression EGS4.4 MC

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Polarization Sensitivity EGS4.4 MC 100% polarized, 100 keV |cos  | < 0.6 Analyzing power ~ 75%

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Recent Development of CdTe Detector Tremendous amount of progress has been made.  Highly uniform, fully active sensors can be produced. 122 keV FWHM 1.35 keV 5 o C Bias 800V (16 kV/cm) 57 Co No Tail Takahashi et al NIM A 436 (see e.g. Takahashi et al. IEEE 2002, June and review by Takahashi & Watanabe IEEE 2001,48,4) -25 ℃

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 CdTe Gamma-ray Imager 5cm Pixel 1.2x1.2mm pixels Pixel 0.2x0.2mm pixels CdTe Pixel 0.67x0.67mm pixels 2dim ASIC (100pixel) 2mm bump bonding ISAS/MHI Patent Applying Takahashi (ISAS)

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Si Strip Detector System Why Double-sided Si Strip Detector?  No self-trigger for CCD.  Hybrid-pixel detector increases non-active material.  Monolithic-pixel detector cannot be produced in large volume. System configuration. V Double-sided Si Strip Detector Front-end VLSI VA32TA RC chip R

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Double-sided Si Strip Detector 2.56cm x 2.56 cm  ~1/2 length of full size sensor. 300 µm thick, 400 µm pitch, 100 µm gap. Strip capacitance: ~ 5.5 pF (measured.) Junction side Ohmic side

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 VA32TA: Low Noise Front-end VLSI Low noise  Front-end MOSFET geometry optimized for small capacitance load in 1.2 µm process. Internal DAC (4-bit trim DAC, bias). Fabricated in AMS 0.35 µm process  Radiation hard to 20 MRad. SEU (single event upset) tolerant. Ideas ASA

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Prototype System AC configuration DC configuration VA32TA Singled-sided SSD RC chip

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Noise Analysis Amplifier noise: capacitance load. Shot noise: leakage current. Thermal noise: detector bias resistance. 120 e – (RMS)

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Noise Performance Summary Config.Temp.  peak Noise (FWHM) MeasuredExpected AC 20 o C 2 µs1.7 keV1.6 keV 4 µs1.7 keV1.6 keV 0 o C 2 µs1.6 keV1.4 keV 4 µs1.4 keV1.1 keV DC0 o C 2 µs1.2 keV1.1 keV 4 µs1.0 keV0.9 keV

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, Am Spectrum DC configuration, 0 o C

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, Am Fit

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, Co Spectrum Compton edge DC configuration, 0 o C

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, Co Fit

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Energy Resolution Summary Config.Temp.  peak Resolution (FWHM) 60 keV122 keV AC 20 o C 2 µs1.9 keV2.1 keV 4 µs2.1 keV2.3 keV 0 o C 2 µs1.8 keV1.9 keV 4 µs1.7 keV1.8 keV DC0 o C 2 µs1.6 keV 4 µs1.3 keV

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Conclusions and Future Prospects Energy resolution measured using prototypes.  1.3 o C for 60 and 122 keV X-rays.  Noise sources are well understood. Imaging test with stacked DSSD prototypes.  Polarization measurements. Further improvements are required for larger full- sized sensors.  Optimization of front-end MOSFET in 0.35 µm process.  Reduction of detector capacitance. Sensor thickness: 300 µm  400 µm.  Pitch adapter.

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Sensitivity Gap… Sensitivity (MeV/cm 2 /s) No approved mission to cover 0.1–20 MeV energy band.  Sensitivity is mostly limited by BG. COMPTEL EGRET Astro-E2 GLAST INTEGRAL EXIST OSSE Next generation Compton telescope

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Liquid Xenon TPC LXeGRIT collaboration

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002 Germanium Compton Telescope

Gamma-ray Polarimetry, H. Tajima, Vertex 2002, Kailua-Kona, Hawaii, Nov. 8, 2002