Two-dimensional and wide dynamic range profile monitor using OTR/fluorescence screens for diagnosing beam halo of intense proton beam Y. Hashimoto, T.

Slides:



Advertisements
Similar presentations
Observation of beam halo with corona graph
Advertisements

Lens  The lens is the most important part of the camera  Lens captures light and focuses the light on the part of the camera that receives the image.
1© Manhattan Press (H.K.) Ltd. Final image at infinity Eye-ring Eye-ring 12.6 Refracting telescope.
Chapter 27 Optical Instruments.
SPHERICAL MIRRORS Free powerpoints at
Coronagraph for diagnosing beam halo
Nature of Light. Light Light can be modeled as a wave and a particle Transverse, electromagnetic wave Photons — particles of light.
1 Laser Beam Coherence Purpose: To determine the frequency separation between the axial modes of a He-Ne Laser All sources of light, including lasers,
Chapter 11 Review Mirrors & Lenses. What is an angle of incidence? 2 The angle between an incident ray and the normal of an optical device. Category:
7. Optical instruments 1) Cameras
7. Optical instruments 1) Cameras
Announcements Office hours: My office hours today 2 -3 pm
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
BSRT Optics Design BI Days 24 th November 2011 Aurélie Rabiller BE-BI-PM.
Beam Splitter. Studio camera on studio pedestal ENG Field Camera for tripod or shoulder.
T. Horn, SHMS Optics Update SHMS Optics Update Tanja Horn Hall C Users Meeting 31 January 2009.
Matching and Synchrotron Light Diagnostics F.Roncarolo, E.Bravin, S.Burger, A.Goldblatt, G.Trad.
S-95 Explain how a curved mirror, and a curved lens are different. Think in terms of image formation and in terms of what light photons do.
Ray Optics: Reflection and Refraction Rays Representation of the path that light follows Represent beams of light that are composed of millions.
Chapter 12 Optical Instruments Physics Beyond 2000.
Fundamental of Optical Engineering Lecture 3.  Aberration happens when the rays do not converge to a point where it should be. We may distinguish the.
A diffraction grating with 10,000 lines/cm will exhibit the first order maximum for light of wavelength 510 nm at what angle? (1 nm = 10-9 m) 0.51° 0.62°
Optics 2: REFRACTION & LENSES. REFRACTION Refraction: is the bending of waves because of the change of speed of a wave when it passes from one medium.
9/25/031 First Tests of an Optical Transition Radiation Detector for High-Intensity Proton Beams at FNAL September 25, 2003 Vic Scarpine.
Chapter 18-1 Mirrors. Plane Mirror a flat, smooth surface light is reflected by regular reflection rather than by diffuse reflection Light rays are reflected.
PHYS 1442 – Section 004 Lecture #22-23 MW April 14-16, 2014 Dr. Andrew Brandt 1 Cameras, Film, and Digital The Human Eye; Corrective Lenses Magnifying.
Recent Progress in X-ray Emittance Diagnostics at SPring-8 S. Takano, M. Masaki, and H. Sumitomo * JASRI/SPring-8, Hyogo, Japan SES, Hyogo, Japan *
Optical diagnostics for beam halo (I) Coronagraph (II) OTR halo monitor for J-PARC T. Mitsuhashi, KEK.
1 Light Chapters 36 – 39 2 Wave or Particle? Newton -- particles. In the early 19 th century, Young, Fresnel, and others -- wave. In 1860 Maxwell --
Eusoballoon optics test Baptiste Mot, Gilles Roudil, Camille Catalano, Peter von Ballmoos Test configuration Calibration of the light beam Exploration.
SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo.
05/05/2004Cyrille Thomas DIAMOND Storage Ring Optical and X-ray Diagnostics.
Measurement of small beam size by SR interferometer By Prof. Dr.Toshiyuki MITSUHASHI KEK.
Laser-Based Finger Tracking System Suitable for MOEMS Integration Stéphane Perrin, Alvaro Cassinelli and Masatoshi Ishikawa Ishikawa Hashimoto Laboratory.
Notes 2-5 OPTICAL TOOLS. Cameras: How do they work? Light from object travels through one or more convex lenses Lens focuses light Puts an image on film.
Multi-colour sctintillator-based ion beam profiler James Green, Oliver Ettlinger, David Neely (CLF / STFC) 2 nd Ion diagnostic workshop June 7-8 th.
“Performance of BTVs during the CNGS commissioning” E. Bravin AB/BI NBI th International workshop on Neutrino Beams and Instrumentation 4-9 September.
SPATIAL RESOLUTION OF NON- INVASIVE BEAM PROFILE MONITORBASED ON OPTICAL DIFFRACTION RADIATION A.P. Potylitsyn Tomsk Polytechnic University, , pr.
The Nature of Light. Light Can Act Like Waves or In 1801 Thomas Young an English scientist did an experiment. –Double slit experiment Passed a beam of.
ELECTRON MOVING AT CONSTANT VELOCITY
Design of Coronagraph for the observation of beam halo at LHC Toshiyuki Mitsuhashi (KEK), Enrico Bravin, Rhodri Jones, Federico Loncarolo Hermann Schmickler,
G. Ferioli, R. Jung - LHC-BI Review Workshop November 19&20 LHC Screen Profile Monitors G. Ferioli, R. Jung Introduction BTV LHC layout Monitor set-up.
Matching monitors for SPS and LHC E. Bravin 31 March 2011.
Thin Lenses A lens is an optical device consisting of two refracting surfaces The simplest lens has two spherical surfaces close enough together that we.
Beam Halo Monitoring using Optical Diagnostics Hao Zhang University of Maryland/University of Liverpool/Cockcroft Institute.
NON-INTERCEPTING DIAGNOSTIC FOR HIGH BRIGHTNESS ELECTRON BEAMS USING OPTICAL DIFFRACTION RADIATION INTERFERENCE (ODRI) A. Cianchi #1,2, M. Castellano 3,
PSB H- injection concept J.Borburgh, C.Bracco, C.Carli, B.Goddard, M.Hourican, B.Mikulec, W.Weterings,
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
Pushing the space charge limit in the CERN LHC injectors H. Bartosik for the CERN space charge team with contributions from S. Gilardoni, A. Huschauer,
Refraction of light pg. 77.
Copyright © 2009 Pearson Education, Inc. Chapter 35-Diffraction.
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Principle and method for angular domain fluorescent imaging. (a) Angular domain.
ODR Diagnostics for Hadron Colliders Tanaji Sen APC.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
Coronagraph for beam halo observation for the HL LHC
Installation new BTV HiRadMat from 2017
Chapter 34 Geometric Optics © 2016 Pearson Education Inc.
Emittance measurements for LI2FE electron beams
Collimation Concept for Beam Halo Losses in SIS 100
7. Optical instruments 1) Cameras
Summary of experience with Tevatron synchrotron light diagnostics
Telescopes.
OTR based measurements for ELI-NP Gamma Beam Source
High resolution profile measurements
Proton Beam Diagnostics
Beam size diagnostics using diffraction radiation
Hall C Users Meeting 31 January 2009
7. Optical instruments 1) Cameras
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Two-dimensional and wide dynamic range profile monitor using OTR/fluorescence screens for diagnosing beam halo of intense proton beam Y. Hashimoto, T. Toyama, T. Mitsuhashi and M. Tejima KEK

In The J-PARC, 1.We want to see beam profile of proton beam (like in the electron machine). 2.We want to see halo profile. 3.What is effect of beam collimator?

~ 122m Location of the monitorBeam collimator J-PARC 3-50 beam transportline

Optical design for OTR profile monitor in beam transportline between 3.5GeV Rapid Cycle Synchrotron and 50GeV main ring The beam size of proton beam is 5cm! *2 dimensional charge distribution *3 dimensional charge distribution Tomographyc observation *2 dimensional halo distribution Light source is OTR and fluorescence screen 5cm

OTR screen for beam core observation! Beam halo Beam core Beam halo observation by screen with hole

Beam halo Beam core screen with hole OTR from beam halo only! Beam halo observation by screen with hole

Fluorescence screen for observation of beam halo in outside Beam halo observation by screen with hole Beam core

Target assembly

2.5×10 10 photons/10 13 protons Intensity : Emitted photon number in a light band (  2 -  1 )  = 4.2  = 32 at 30GeV OTR : 3GeV Proton Beam (Low γ )

Angular distribution of OTR from 3.5GeV Al foil target and proton beam PS 12GeV RCS 3GeV Peak is in 350mrad!

Imaging device few mrad lens OTR screen 45º Large field depth by large object Typical OTR profile monitor at electron machine

Imaging device 50 mrad OTR screen 45º Large field depth by large object Toyoda, Mitsuhashi 2009 for slow extraction line at J-PARC 6000mm 300mm

Large field depth by large object 500mrad 500mm 45degree set up of target will impossible! Too long field depth!

500mrad 500mm beam Foil target must be normal to the beam!

Proton beam Offner relay system Spherical 1 st mirror D=600mm R=500mm Spherical 2ed mirror D=200mm R=250mm 500 mrad D=300mm 2枚

Application of Offner relay system to reflective input optics for the Streak camera (2002)

Design of Offner relay system Object size: 50mm General aperture 300mm

First mirror Spherical concave 300mm in diameter f=500mm Second mirror Spherical convex 200mm in diameter f=250mm Third mirror Spherical concave 300mm in diameter f=500mm

Grid chart test Clear region +/-45mm in vertical +/-100mm in horizontal

Direct observation of beam image by reduction system Design of reduction system How to reduce image filed (100mm x 100mm) into CCD aria (10mm x 10mm)? Magnification of Offner system is 1:1, so image field is 10cmx10cm. A reduction system having magnification factor less than 0.1 will necessary.

We cannot realize large reduction ratio with simple configurations. Often focus point is in the lens ! We must design long backfocus. Apply a retro-focus design Configuration of retro-focus f H2H2 H1H1 f

Lens material: B270 (a kind of white crown glass) Acceptance 300mrad Large reduction optics system with retro- focus design Long working distance is necessary for observing image in vacuum chamber

Large reduction ratio is impossible!

Aperture of next optics

Proton beam diffuser screen

Diffuser screen Angular opening of OTR is shacking by PSF of diffuser

Diffuser screen Lens aperture

Alumina fluorescence screen +OTR screen

Alumina fluorescence screen +OTR screen Offner relay optical system

Alumina fluorescence screen +OTR screen Offner relay optical system Diffuser screen

Alumina fluorescence screen +OTR screen Offner relay optical system Diffuser screen Image intensifier+ CID camera

Beam core image (OTR)

Beam core image (OTR) and beam halo (FL)

For the scaling of different images, 1. Gain ratio G R of image intensifier G R =G 1000 /G SET G 1000 : Gain at MCP1000V G SET : Gain at each observation 2. Ratio between fluorescence and OTR in the same region

Adding vertical fluorescence screen

OTR fluorescence Movable fluorescence Screen for beam halo observation Beam Profile (Projection ) Titanium foil target for beam core observation fluorescence Four fluorescence screen are set in vertical and horizontal arrangement in front of OTR screen

Observation of effect of beam collimator for beam halo

Superimposed image of beam core (OTR), one image of beam halo near by core (OTR) and Beam halo in far from core (fluorescence)

Difference in order of to Collimator offCollimator on

Collimator OFF Collimator ON Horizontal collimator

Collimator OFF Collimator ON Vertical collimator

A Simultaneous observation of beam core with OTR and fluorescence screen

OTR Fluorescence 1ms (1/10) About 200nsec )

OTR Fluorescence Choose exposure time 1ms (1/10) About 200nsec ) Change the exposure time of I.I. Gate to get a nice contrast between beam core and halo

100  Painting 50  Painting 60mm 54mm Horizontal vertical

Tomographic observation By using high speed gated camera Observe sliced images (minimum temporal width 3nsec) along longitudinal axis. About 100nsec

Thank you very much for your attention!