28 June 2002Santa Cruz LC Retreat M. Breidenbach1 SD – Silicon Detector EM Calorimetry.

Slides:



Advertisements
Similar presentations
Jaap Velthuis, University of Bristol SPiDeR SPiDeR (Silicon Pixel Detector Research) at EUDET Telescope Sensor overview with lab results –TPAC –FORTIS.
Advertisements

Victoria04 R. Frey1 Silicon/Tungsten ECal Status and Progress Ray Frey University of Oregon Victoria ALCPG Workshop July 29, 2004 Overview Current R&D.
7 January 2005 MDI Workshop M. Breidenbach 1 SiD Electronic Concepts SLAC –D. Freytag –G. Haller –J. Deng –mb Oregon –J. Brau –R. Frey –D. Strom BNL –V.
10 Nov 2004Paul Dauncey1 MAPS for an ILC Si-W ECAL Paul Dauncey Imperial College London.
R Frey 9/15/20031 Si/W ECal Update Outline Progress on silicon and tungsten Progress on readout electronics EGS4 v Geant4 Ray Frey M. Breidenbach, D. Freytag,
7 June 2006 SLAC DOE Review M. Breidenbach 1 KPiX & EMCal SLAC –D. Freytag –G. Haller –R. Herbst –T. Nelson –mb Oregon –J. Brau –R. Frey –D. Strom BNL.
Design Considerations for a Si/W EM Cal. at a Linear Collider M. Breidenbach, D. Freytag, G. Haller, M. Huffer, J.J Russell Stanford Linear Accelerator.
Progress towards a Long Shaping-Time Readout for Silicon Strips Bruce Schumm SCIPP & UC Santa Cruz SLAC LC Workshop January 6-10, 2004.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
NIU Workshop R. Frey1 Reconstruction Issues for Silicon/Tungsten ECal R. Frey U. Oregon NIU Workshop, Nov 8, 2002.
GLAST LAT Readout Electronics Marcus ZieglerIEEE SCIPP The Silicon Tracker Readout Electronics of the Gamma-ray Large Area Space Telescope Marcus.
GLAST LAT Readout Electronics Marcus ZieglerIEEE SCIPP The Silicon Tracker Readout Electronics of the Gamma-ray Large Area Space Telescope Marcus.
14 July 2003 American Linear Collider Workshop M. Breidenbach 1 SD, an Introduction SD = Silicon Detector –Motivation –Simulation –Description –Status.
ICLC Paris R. Frey1 Silicon/Tungsten ECal for SiD – Status and Progress Ray Frey University of Oregon ICLC Paris, April 22, 2004 Overview (brief) Current.
Progress towards a Long Shaping-Time Readout for Silicon Strips Bruce Schumm SCIPP & UC Santa Cruz SLAC LCWS05 July 28-31, 2004.
27 th May 2004Daniel Bowerman1 Dan Bowerman Imperial College 27 th May 2004 Status of the Calice Electromagnetic Calorimeter.
LCWS2002 R. Frey1 Silicon/Tungsten ECal for the SD Detector M. Breidenbach, D. Freytag, G. Haller, M. Huffer, J.J Russell Stanford Linear Accelerator Center.
19 March 2005 LCWS 05 M. Breidenbach 1 SiD Electronic Concepts SLAC –D. Freytag –G. Haller –J. Deng –mb Oregon –J. Brau –R. Frey –D. Strom BNL –V. Radeka.
SiD EMCal Testbeam Prototype M. Breidenbach for the SiD EMCal and Electronics Subsystems.
Oct, 2000CMS Tracker Electronics1 APV25s1 STATUS Testing started beginning September 1 wafer cut, others left for probing 10 chips mounted on test boards.
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
Study of FPCCD Vertex Detector 12 Jul. th ACFA WS Y. Sugimoto KEK.
L.Royer– Calice DESY – July 2010 Laurent ROYER, Samuel MANEN, Pascal GAY LPC Clermont-Ferrand R&D LPC Clermont-Fd dedicated to the.
10 July 2001Snowmass 2001 M. Breidenbach1 This Detector Can’t Be Built without lots of work.
1 Alessandra Casale Università degli Studi di Genova INFN Sezione Genova FT-Cal Prototype Simulations.
SPiDeR  SPIDER DECAL SPIDER Digital calorimetry TPAC –Deep Pwell DECAL Future beam tests Wishlist J.J. Velthuis for the.
Roger Rusack – The University of Minnesota 1.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
The CMS Electromagnetic Calorimeter Roger Rusack The University of Minnesota On behalf of the CMS ECAL collaboration.
June 1-5, Santa Fe N. M. Vertex Ultra-fast Silicon Detectors June 3, 2015 Abe Seiden UC Santa Cruz.
EUDET JRA3 ECAL and FEE C. de La Taille (LAL-Orsay) EUDET status meeting DESY 10 sep 2006.
March 2004 CALOR 2004, Perugia, Italy Super-dense W-Si Calorimeter for the Forward Spectrometer Upgrade of PHENIX at RHIC (*) on behalf of the PHENIX Forward.
Beam Tests of 3D Vertically Interconnected Prototypes Matthew Jones (Purdue University) Grzegorz Deptuch, Scott Holm, Ryan Rivera, Lorenzo Uplegger (FNAL)
DAQ for 4-th DC S.Popescu. Introduction We have to define DAQ chapter of the DOD for the following detectors –Vertex detector –TPC –Calorimeter –Muon.
Thin Silicon R&D for LC applications D. Bortoletto Purdue University Status report Hybrid Pixel Detectors for LC.
SiD R&D tasks for the LOI - Subsystem R&D tasks - Summary of SiD R&D - Prioritization of R&D tasks -> Document for DoE/NSF ~Feb 2009 (Mainly based on Marty’s.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
Silicon Detector Tracking ALCPG Workshop Cornell July 15, 2003 John Jaros.
26 Apr 2009Paul Dauncey1 Digital ECAL: Lecture 2 Paul Dauncey Imperial College London.
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
Rutherford Appleton Laboratory Particle Physics Department G. Villani CALICE MAPS Siena October th Topical Seminar on Innovative Particle and.
LHCb Vertex Detector and Beetle Chip
R Frey LCWS071 A Silicon-Tungsten ECal with Integrated Electronics for the ILC -- status Currently optimized for the SiD concept Baseline configuration:
D. M. Lee, LANL 1 07/10/07 Forward Vertex Detector Overview Technical Design Overview Design status.
Custom mechanical sensor support (left and below) allows up to six sensors to be stacked at precise positions relative to each other in beam The e+e- international.
EMCal Sensor Status (* M. Breidenbach*,
July 7, 2008SLAC Annual Program ReviewPage 1 Silicon Tracking / Silicon Readout R&D Richard Partridge SLAC / Brown.
1 19 th January 2009 M. Mager - L. Musa Charge Readout Chip Development & System Level Considerations.
Silicon/Tungsten ECal for the SD Detector – Status and Progress R. Frey U. Oregon UT Arlington, Jan 10, 2003.
5 May 2006Paul Dauncey1 The ILC, CALICE and the ECAL Paul Dauncey Imperial College London.
18 Sep 2008Paul Dauncey 1 DECAL: Motivation Hence, number of charged particles is an intrinsically better measure than the energy deposited Clearest with.
Front-end Electronic for the CALICE ECAL Physic Prototype Christophe de La Taille Julien Fleury Gisèle Martin-Chassard Front-end Electronic for the CALICE.
A Forward Calorimeter (FoCal) as upgrade for the ALICE experiment at CERN S. Muhuri a, M. Reicher b and T. Tsuji c a Variable Energy Cyclotron Centre,
Durham TB R. Frey1 ECal R&D in N. America -- Test Beam Readiness/Plans Silicon-tungsten SLAC, Oregon, Brookhaven (SOB) Scintillator tiles – tungsten U.
16 August 2005 SiD Snowmass 05 M. Breidenbach 1 SiD Expectations from the Design Study –Motivation –What We Need! –Technical efforts –Status.
FCAL R&D towards a prototype of very compact calorimeter
Jean-Francois Genat LPNHE Universite Pierre et Marie Curie CNRS/IN2P3
A SiW EM Calorimeter for the Silicon Detector
Panagiotis Kokkas Univ. of Ioannina
Linear Collider Detector
Lars Reuen, 7th Conference on Position Sensitive Devices, Liverpool
SiD Electronic Concepts
A Silicon-Tungsten ECal for the SiD Concept
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Vertex Detector Overview Prototypes R&D Plans Summary.
SiD Tracker Concepts M. Breidenbach
Why silicon detectors? Main characteristics of silicon detectors:
Presentation transcript:

28 June 2002Santa Cruz LC Retreat M. Breidenbach1 SD – Silicon Detector EM Calorimetry

28 June 2002Santa Cruz LC Retreat M. Breidenbach2 SD (Silicon Detector) Conceived as a high performance detector for NLC Reasonably uncompromised performance But Constrained & Rational cost We accept the notion that excellent energy flow calorimetry is required, and explore optimization of a Tungsten-Silicon EMCal…

28 June 2002Santa Cruz LC Retreat M. Breidenbach3 Silicon Detector EM Calorimetry

28 June 2002Santa Cruz LC Retreat M. Breidenbach4 Scale of EMCal & Vertex Detector

28 June 2002Santa Cruz LC Retreat M. Breidenbach5 Silicon Tungsten EMCal Figure of merit something like BR 2 /  where  is the rms sum of Moliere radius of the calorimeter and the pixel size. –Maintain the great Moliere radius of tungsten (9 mm) by minimizing the gaps between ~2.5 mm tungsten plates. Dilution is (1+Rgap/Rw) –Could a layer of silicon/support/readout etc fit in a 2.5 mm gap? Even less?? 1.5 mm goal?? Requires aggressive electronic-mechanical integration!

28 June 2002Santa Cruz LC Retreat M. Breidenbach6 EMCal, continued Diode pixels between 5 – 10 mm square on largest hexagon fitting in largest available wafer. (6” available now – 300 mm when??) Consider  tracking as well as E flow in picking pixel dimension. Develop readout electronics of preamplification through digitization, zero suppression and IO on bump bonded chip. Upgrade would be full integration of readout on detector wafer. (R&D opportunity!) Optimize shaping time for small diode capacitance. Probably too long for significant bunch localization within train. But some detector element needs good time resolution!!!

28 June 2002Santa Cruz LC Retreat M. Breidenbach7 Channel Counts [Forget Them!!] We are used to pixel counts in CCD’s … –3x10 8 last time, 1x10 9 this time, no problem Silicon Strip Tracker ~5x10 6 strips (channels??) EMCal ~5x10 7 pixels (channels??) Don’t even think about multiplying channels by O($10)…… Must solve the cluster technology challenges.

28 June 2002Santa Cruz LC Retreat M. Breidenbach8 Structure

28 June 2002Santa Cruz LC Retreat M. Breidenbach9 Pixels on 6” Wafer

28 June 2002Santa Cruz LC Retreat M. Breidenbach10 Zoom to Readout Chip

28 June 2002Santa Cruz LC Retreat M. Breidenbach11 Gross System Architecture Silicon Diode Array Readout Chip Network Interconnect

28 June 2002Santa Cruz LC Retreat M. Breidenbach12 Cross Section

28 June 2002Santa Cruz LC Retreat M. Breidenbach13 Signal Collection from m 2 board

28 June 2002Santa Cruz LC Retreat M. Breidenbach14 Preamplifier Architecture Charge amplifier and shaper followed by two amplifiers with gains G1,G2 and sample & holds. Comparator logic to select appropriate range Mux and 12 bit ADC

28 June 2002Santa Cruz LC Retreat M. Breidenbach15 Noise and Muons Assume 300  (  possible) effective e - collection at 80 e - / . signal ~ e -. Assuming diode capacitance of 0.3 pf/mm 2, and amplifier noise of 20e - /pf+200e - – noise ~400 e -. S/N ~60, plenty good! Pick S/N of 7 (Figure) for minimum performance.

28 June 2002Santa Cruz LC Retreat M. Breidenbach16 Plausible Resolution Criteria Spread the 0.6% muon  into several bins, with enough range for MIP counting to a few. Preliminary Monte Carlo indicates peak ionizing track density from a high energy shower to be 2200 µ equivalent. (5 x 10 7 e - = 8 pC.) Do not degrade resolution of calorimeter! Energy resolution of a sampling calorimeter with 2/3 X 0 plates will not exceed 12%/√E. Say this peak should be spread over 5 bins, and take no credit for multiple sampling. Relaxation of these requirements now being studied with EGS.

28 June 2002Santa Cruz LC Retreat M. Breidenbach17 Required Resolution High Res Bin Width=1000 e -, Emax=37 GeV,Mips=170 Low Res Bin Width=13200 e -,Emax=512 GeV,Mips=2325

28 June 2002Santa Cruz LC Retreat M. Breidenbach18 Technical Issues Assuming integrator full scale voltage of around 1 V, feedback (and calibration) capacitors need to be ~10 pF. This is large for an integrated capacitor, but doable with substantial real estate. Plus is that this makes the bump bond pitch easy!

28 June 2002Santa Cruz LC Retreat M. Breidenbach19 Thermal Management Cooling is a fundamental problem: GLAST system is ~2 mW/channel. Assume 1000 pixels/wafer and power pulsing duty factor for NLC of (10 Hz), for 2 mW average power. Assume fixed temperature heat sink (water cooling) at outer edge of an octant, and conduction through a thick (6 oz) copper ground plane in the G10 motherboard. ΔT~1 0 C. This is fine, but it sure doesn’t work without power pulsing!!! Holding the power down while maintaining the noise/resolution is a serious engineering challenge.

28 June 2002Santa Cruz LC Retreat M. Breidenbach20 Plans We (Oregon and SLAC) plan to develop this design in more detail and build prototype wafers and chips. Test detectors in 5 Tesla field. If successful, develop board level chip. Build 1 wafer wide by about 25 X 0 deep calorimeter for test beam.