School of Chemistry and Biochemistry

Slides:



Advertisements
Similar presentations
Chemical Sensors for Autonomous and Lagrangian Platforms Ken Johnson, Monterey Bay Aquarium Research Institute.
Advertisements

Micro Photometers & Spectral Sensors for the NeSSI Platform John Coates Coates Consulting IFPAC 2006 NeSSI Update.
Dr. Thaweesak Tirawatnapong Chula Medical Research Center (Chula MRC)
E VERY L IFE H AS A P URPOSE… Chemgard TM Infrared Gas Monitor.
Simple, Fast and Accurate Solvent-free Method for Produced Water Process Monitoring.
Analytical Chemistry.
I n t e g r i t y - S e r v i c e - E x c e l l e n c e Headquarters U.S. Air Force 1 Direct Sampling Ion Trap Mass Spectrometry Rob R. Smith Oak Ridge.
Caffeine as a Surrogate for Cocaine in an HPLC Forensic Experiment Ray A. Gross Jr, Indravadan Shah and Muhamed Jasarevic Department of Physical Sciences.
Flame photometry.
Diffusion. Solutions SolventSolvent – liquid SoluteSolute - solid that is dissolved SolutionSolution – liquid with dissolved substances SolubleSoluble.
University of Missouri DETECTION AND SURVEILLANCE Sheila Grant Department of Biological Engineering UMC.
Standard Addition Used with difficult matrices such as blood Difficult to get an accurate comparison of the amount of analyte in sample vs. amount of analyte.
Development of an Automated, Pyridine Free Method for Aerosol Cyanide Compounds and Hydrogen Cyanide. An Alternative to NIOSH LeRoy Dobson, Chemist.
Integration of miniaturized complex diagnostic tests : from the macro sample to the test reading Nanoforum 2005 Nanotechnology in BioDiagnostics and Analytics.
Design of Health Technologies lecture 12 John Canny 10/17/05.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Partitioning of Volatile Organic Carbon Compoundss.
Real-Time Detection of Biological Pathogens in Urban Environments Laura Barry Hung Phan Gloria See Introduction to Biosensors Presentation 2 - 4/5/2011.
Ch. 30 Capillary Electrophoresis, Capillary Electrochromatography
Distributed Microsystems Laboratory ENose Toolbox: Application to Array Optimization including Electronic Measurement and Noise Effects for Composite Polymer.
Partitioning of VOCs: Why do we care? ä Determines how best to treat a site ä vapor extraction ä pump and treat ä remove contaminated soil ä Determines.
Detection of Copper in Wastewater Seth Holm Chem4101 December 2009.
Automated Chemical and Biological Sensing in Sensor Networks MicroLabs.
Tabu Search-Based Synthesis of Dynamically Reconfigurable Digital Microfluidic Biochips Elena Maftei, Paul Pop, Jan Madsen Technical University of Denmark.
MPS/DMR Materials for sensors New materials and chemical processes are the starting point for advances and innovation in critical sensor systems. Sensors.
ATWARM Advanced Technologies for Water Resource Management Marie Curie Initial Training Network Next Generation Autonomous Analytical Platforms for Remote.
Flocculants for Water Treatment Date: May ???,2011 Speaker :Speaker A 、 Speaker B 、 Speaker C.
Laser Induced breakdown spectroscopy in Water for elemental analysis.
Florida Operations Level Hazardous Materials Training Unit 5.5 MISSION SPECIFIC: Air Monitoring and Sampling.
Development of a new microfluidic analysis system on silicon with different nanostructures as sensitive elements Mihaela Miu, Irina Kleps, Florea Craciunoiu,
Programmable Microfluidics Using Soft Lithography J.P. Urbanski Advisor: Todd Thorsen Hatsopoulos Microfluidics Lab, MIT January 25/2006.
AUTOANALYZER T. Elsarnagawy 22/12/ Elsarnagawy, MASH
INTRODUCTION TO ANALYTICAL CHEMISTRY ERT 207 ANALYTICAL CHEMISTRY SEMESTER 1, ACADEMIC SESSION 2015/16.
Flow cell design for WGM optical biosensor Yongqiang Yang BE8280 spring 2015.
Standard Addition Used with difficult matrices such as blood Difficult to get an accurate comparison of the amount of analyte in sample vs. amount of analyte.
What is Analytical Chemistry?
Minority Access To Research Careers. By, Nicholas G. Beltran Mentor: Dr. Antonio S. Lara Department of Chemistry and.
Field Analytical Methods. Considerations for Field Analytical Methods Which parameters are anticipated to occur at the site? What media will be analyzed?
Ammonia Measurement Techniques Ji-Qin (Jee-Chin) Ni, Ph.D. Dept. of Agricultural and Biological Engineering Purdue University October 21, 2008 Albuquerque,
Nucleic Acid Purification : Its Principle and Miniaturization MEC seminar Apr. 13 Ji Youn Lee.
Minibioreactors -> Volumes below 100 ml Characterized by: -> area of application -> mass transfer -> mixing characteristics.
Nanofluidic Microsystems for Advanced Biosample Preparation Ying-Chih Wang 1, Jianping Fu, Yong-Ak Song and Jongyoon Han 2,3 1 Department.
1 ERT 207 Analytical Chemistry ERT 207 ANALYTICAL CHEMISTRY ALINA RAHAYU MOHAMED School of Bioprocess Engineering University Malaysia Perlis 02600, Kangar.
Lecture 1 – What is Analytical Chemistry? & What is the Analytical Method?
© 2006 MSA VaporLab™ 700 Gas Analyzer. © 2006 MSA Product Description  Rack mount, turn-key gas analyzer  Analyzes a complex matrix for trace quantities.
By- Bhavya, Harsh, Harshvardhan, Namrata, Ronit and Vidhatri
Water toxicity detection through perfusion and monitoring of living cells on a microfluidic chip Fang Li, Ph.D. Department of Mechanical Engineering New.
What is analytical chemistry? Analytical chemistry is what analytical chemists do. Analytical chemistry is a measurement science consisting of a set of.
TOWARDS A TEST METHOD FOR HYDROGEN SENSOR PERFORMANCE NATHAN D. MARSH AND THOMAS G. CLEARY Fire Research Division, National Institute of Standards and.
Jenna Simandl, Civil Engineering, University of Alabama Cuong Diep, Chemical Engineering, University of Cincinnati Sidney Stacy, Biomedical Engineering,
Lab-on-a-Chip The Ideal Technology for Bio-chemical Analysis
Use of Molecular Signatures for in situ Detection of Organisms and Genes They Express The Next Generation of in situ Biological and Chemical Sensors in.
Chapter 1: The Nature of Analytical Chemistry
Chemical Solutions Preparations General Biochemistry Laboratory BIOC 201 Rami M. Mosaoa.
Metal Nanoparticle Hydrogen Sensor
1 Placement-Aware Architectural Synthesis of Digital Microfluidic Biochips using ILP Elena Maftei Institute of Informatics and Mathematical Modelling Technical.
Fundamentals of Analytical Chemistry Eighth Edition.
Energy measuring Instruments
Analytical Chemistry.
University of Leicester
PORTABLE HIGH-SPEED GAS CHROMATOGRAPH
Mr. Quinn & Ms. Tom March 17, 2014 Aim: Why do the factors we have studied affect rate of reaction? Do Now: What effect do the factors.
A non-amplification molecular probe approach John Gerdes, Ph. D.
Unit 5: Solutions ppm and ppb.
Environmental Toxicology
Molding PDMS Channels and an Embedded Detector Chamber
Biochemistry Biology Review L – Properties of Water Discuss the special properties of water that contribute to Earth's suitability as an environment.
Unit 5: Solutions ppm and ppb.
Philippe Dekleva and Scott Noblitt MicroChemica, LLC Fort Collins, CO
CasE13a Schematic of the development of antibiotic resistance and how it can spread to humans.
Presentation transcript:

School of Chemistry and Biochemistry DETECTION OF TOXIC AGENTS IN WATER SYSTEMS J. (ART) JANATA School of Chemistry and Biochemistry Georgia Institute of Technology E-mail: jiri.janata@chemistry.gatech.edu Phone: 404 256 0186 OUTLINE • OVERVIEW OF SENSORS/SYSTEMS - BASICS • CHARACTERISTICS OF THE APPLICATION • CONCLUSIONS Workshop: “NEW TECHNOLOGIES”, Newark, June 27-28,2002 THIS PRESENTATION OUTLINES THE PROPERTIES OF SENSORS THAT ARE RELEVANT TO THE TASK OF PROTECTING DRINKING WATER SUPPLIES AGAINST INTENTIONAL OR UNINTENTIONAL CONTAMINATION.

SENSORS ARE DIFFERENT THAN SENSING SYSTEMS • SENSORS ACQUIRE INFORMATION CONTINUOUSLY • SENSING SYSTEMS (ASSAYS) ARE DISCONTINUOUS, CONTAIN DISCRETE STEPS THERE IS A FUNDAMENTAL DIFFERENCE BETWEEN SENSORS AND SENSING SYSTEMS (ASSAYS). THE FORMER ACQUIRE INFORMATION CONTINUOUSLY WHILE THE LATTER DO IT DISCRETELY, IN SERIES OF STEPS. THE TWO APPROACHES ARE COMPLEMENTARY. THE CHOICE OF ONE OVER THE OTHER IS ALWAYS DICTATED BY THE APPLICATION.

THE SIGNAL IN CHEMICAL SENSORS ARISES FROM THE INTERACTION OF THE ANALYTE WITH THE SELECTIVE LAYER. THIS INTERACTION CAN OCCUR EITHER IN THE BULK OF THE LAYER OR AT ITS SURFACE. INVARIABLY, IT NEEDS TO BE AMPLIFIED. THERE ARE FOUR GROUPS OF AMPLIFICATION MECHANISMS USED IN CHEMICAL SENSORS

SENSOR BASICS RESPONSE CONCENTRATION SATURATION DYNAMIC RANGE SENSITIVITY INTERFERENCES RESPONSE CONCENTRATION DETECTION LIMIT THE RESPONSE CURVE OF THE SENSOR HAS COMMON IMPORTANT CHARACTERISTICS. THE RANGE OF CNCENTRATIONS IN WHICH THE SENSOR RESPONDS IS CALLED DYNAMIC RANGE. IT IS BOUND ON ITS UPPER END BY THE SATURATION LIMIT AND ON ITS LOWER END BY THE DETECTION LIMIT. INCREASING AMOUNT OF INTERFERING COMPOUNDS SHIFTS THE DETECTION LIMIT TO HIGHER CONCENTRATIONS THUS REDUCING THE DYNAMIC RANGE. SENSITIVITY IS THE SLOPE OF THE RESPONSE CURVE IN THE DYNAMIC RANGE.

t tdel t63% RESPONSE TIME > minutes for bulk GENERAL LIMITATIONS OF CONTINUOUS OPERATION • BASELINE STABILITY • LOSS OF SENSITIVITY • POWER CONSUMPTION t63% TIME RESPONSE 63% tdel RESPONSE TIME IS ANOTHER FIGURE OF MERIT THAT DESCRIBES THE DYNAMIC CHARACTERISTICS OF THE SENSOR. FOR EXPONENTIALLY RESPONDING SENSORS IT IS THE TIME WHEN THE SIGNAL REACHES THE 63%OF ITS MAXIMUM VALUE. FOR NON-EXPONENTIAL SENSORS IT CAN BE CHOSEN ARBITRARILY AS E.G. 95% OR 99% OF THE MAXIMUM VALUE. > minutes for bulk < seconds for surface t

BIOSENSING SYSTEM (ASSAY) SAMPLE REAGENT ADDITION INCUBATION MEASUREMENT INTRODUCTION DISCRETE STEPS SENSING SYSTEMS OPERATE IN SEQUENCE OF STEPS. THE ANALYTICAL INFORMATIONIS ACQUIRED WITH CERTAIN INFORMATION ACQUISITION FREQUENCY. IN SLOWLY CHANGING SAMPLES SENSING SYSTEMS MAY BE PREFERABLE BECAUSE THEY ALLOW FOR INTERMITTENT CALIBRATION TO BE PERFORMED. MOST “BIOSENSORS” DISCUSSED IN THE LITERATURE ARE IN REALITY “BIOSENSING SYSTEMS”. EVALUATION READOUT INFORMATION CALIBRATION POINT TIME

Revolutionary Advance in Laboratory Technology Solution: Lab-on-a-Chip Technology Revolutionary Advance in Laboratory Technology Miniaturization, Integration, Automation The Lab-on-a-Chip accomplishes life sciences data acquisition using a novel paradigm of integration: miniature, automated data is generated by processing a large portion of the protocol on the same device, rather than shuttling test tubes or multiwell plates from one single function device to the next.

An integrated microfluidic device Nanoliter internal volumes, channel cross-sections in the 10 to 100 µm range (needed for fast diffusion times) Electrokinetic movement of liquids and samples (allows for control at many wells) PHOTOGRAPH OF A TYPICAL MICROFLUIDIC BIOSENSING SYSTEM (Courtesy of Caliper Inc.). NOTE THAT THE VOLUME OF THE LIQUID HANDLED BY THIS CHIP IS IN NANOLITERS

Personal Laboratory Workstation PHOTOGHRAPH OF CALIPER BYOSENSING SYSTEM (Courtesy of Caliper Inc.) http://www.chem.agilent.com/cag/products/intro_g.htm

The Microfluidic Toolbox 1 Separations: DNA, RNA, Proteins 2 Enzyme Activity Assays 3 Joule Heating on a Chip 4 PCR on a Chip 5 Solid Phase Reagent Storage 6 Cell and Bead Assays 7 Viscometer 8 Sample Preparation AN EXAMPLE OF TYPES OF BIOASSAYS PERFOMED BY THE CALIPER SYSTEM

FLOW INJECTION ANALYSIS IS ANOTHER SENSING SYSTEM ARRANGEMENT FLOW INJECTION ANALYSIS IS ANOTHER SENSING SYSTEM ARRANGEMENT. IT OPERATES WITH MICROLITER SAMPLES. PRACTICALLY ALL WET-ANALYTICAL PROCEDURES HAVE BEEN PERFORMED IN THE FIA FORMAT. IT IS FULLY MODULAR.

FIELD-DEPLOYABLE SYSTEM FOR Cr(VI) ANALYSIS Sample Size: < 500 microliters 50 microliters analyzed < 2 minutes per sample total volume of waste 1.5 milliliters per sample 10 ppb to 5 ppm range EXAMPLE OF FIA ANALYSIS FOR Cr(VI) IN ENVIRONMENTAL SAMPLES PERFORMED IN “SEQUENTIAL FLOW ANALYSIS MODE”

CHARACTERISTICS OF DETECTION IN WATER SYSTEMS • LARGE SAMPLE VOLUME • DILUTION • LONG TIME CONSTANT • WATER AS A MEDIUM • HYDROLYSIS • BIOLOGICAL AGENTS • LIMITED ACCESIBILITY OF WATER TOWERS • EASY ACCESS TO RESERVOIRS THE CHOICE OF THE DIRECT SENSORS OR SENSING SYSTEMS IS DICTATED BY THE CHARACTERISTICS OF THE APPLICATION. FOR WATER ANALYSISSENSING SYSTEMS WOULD BE A BETTER CHOICE BECAUSE OF THE LARGE AVAILABLE SAMPLE VOLUMES, REQUIREMENT OF LONG TERM STABILITY OF THE BASELINE, USUALLY AVAILABLE SPACE. WATER AS THE ANALYTICAL MEDIUM IS A PREREQUISITE FOR MOST BIOASSAYS.

TOXICITIES OF LETHAL GASES HERE IS AN EXAMPLE HOW THE POTENCY OF A TOXIC COMPOUND CHANGES WITH THE MODE OF ITS DEPLOYMENT. THIS EXAMPLE IS TAKEN FROM THE APPLICATION OF TOXIC GASES.

TOXICITY OF VARIOUS COMPOUNDS IS EXPRESSED ON LOG SCALE, RELATIVE TO CHLORINE WHICH IS TAKEN AS ONE

IF THE TOXIC GAS IS APPLIED FROM THE TOP ITS TOXICITY MUST BE MULTIPLIED BY ITS RELATIVE DENSITY WITH RESPECT TO AIR. THAT YIELDS ITS “POTENCY” FOR THIS FORM OF DEPLYOMENT

THE SAME GROUP OF COMPOUNDS RELEASED FROM THE “BOTTOM UP” HAVE A POTENCY DETERMINED BY THEIR VOLATILITY

HARMFUL AGENTS DETECTION • INORGANIC POISONS: HEAVY METALS; CYANIDE... • INFECTIOUS BACTERIAL/VIRAL AGENTS • TOXINS: AFLATOXINS, RICINE, ANTHRAX,... • RADIONUCLIDES: Cs-137; Sr-90; Tc-99m; Np-237,... HARMFUL AGENTS TO WORRY ABOUT WITH RESPECT TO THE WATER SUPPLY DETECTION • ASSAYS • RADIATION DETECTORS

IMPORTANT DIFFERENCES BETWEEN DETECTION OF THREAT AGENTS IN AIR AND IN WATER GAS WATER REQUIRED RESPONSE TIME SHORT LONG BIOAGENTS DIFFICULT EASY DISTRIBUTION PATTERNS COMPLEX PREDICTABLE REMEDIAL ACTION COMPLEX SIMPLE MODES OF ATTACK MANY FEW AVAILABLE SPACE LIMITED AMPLE IMPACT LIMITED LARGE IN THIS VUGRAPH IMPORTANT DIFFERENCES BETWEEN DETECTION IN WATER IND IN AIR ARE OUTLINED

CONCLUSIONS (PROTECTION OF WATER SYSTEMS) PROTECTION OF CLOSED SPACES OR WATER SUPPLIES HAS TO BE DESIGNED WITH SPECIFIC CHARACTERISTICS OF EACH SIUATION IN MIND. THIS CONCLUSION HAS BEEN REACHED AT THE NSF-SPONSORED WORKSHOP HELD IN JANUARY 2002. NSF Workshop: “New Challenges in Chemical and Biosensing”, January 9-10, 2002 http://www.chemistry.gatech.edu/sensingforum-02/