Kara Hoffman Mark Oreglia. A promising bolometric material: platinum high Z = large dE/dx temperature-resistivity function very steep at 20K should.

Slides:



Advertisements
Similar presentations
Semiconductor detectors
Advertisements

Radiation damage in silicon sensors
Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
Kara Hoffman Mark Oreglia Students: David Billmire Steve Olmschenk.
Development of high rate RPCs Lei Xia Argonne National Laboratory.
Design Studies and Sensor Test for the Beam Calorimeter of the ILC Detector E. Kuznetsova DESY Zeuthen.
Diamond Manufacturers for ATLAS Upgrades March 26, 20121R. Kass Brief Overview: Next Upgrade (IBL): Diamond Beam Monitor (DBM) News from two diamond manufacturers.
Characterization of primed state of CVD diamond by light and alpha particles C. Manfredotti Experimental Physics Department University of Torino INFN-
Solid State Detectors- 4 T. Bowcock 2 Schedule 1Position Sensors 2Principles of Operation of Solid State Detectors 3Techniques for High Performance Operation.
For the RD42 Collaboration
Investigation of the properties of diamond radiation detectors
Test of Pixel Sensors for the CMS experiment Amitava Roy Purdue University.
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Kara Hoffman The University of Chicago Enrico Fermi Institute and the MuCool Collaboration May 14, 2004 A brief history and first results.
TOF at 10ps with SiGe BJT Amplifiers
FREE CARRIER ABSORPTION TECHNIQUES - MICROWAVE & IR –
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
Semiconductor detectors An introduction to semiconductor detector physics as applied to particle physics.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Fast Timing with Diamond Detectors Lianne Scruton.
Current Status of Diamond Sensors R&D in Minsk Group FCAL Collaboration Institute of Nuclear Physics PAN February 12-13, 2006, Krakow, Poland.
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
Kara Hoffman The University of Chicago Enrico Fermi Institute.
22 December 20143rd FCAL Hardware WG Meeting 1 BeamCal sensors overview Sergej Schuwalow, DESY Hamburg.
22 October 2009FCAL workshop, Geneve1 Polarization effects in the radiation damaged scCVD Diamond detectors Sergej Schuwalow, DESY Zeuthen On behalf of.
Laser Stripping and H 0 monitor systems 10/18/2011B.Cheymol, E. Bravin, U. Raich, F. Roncarolo BE/BI1.
CVD diamond detector as a beam monitor for a high intensity and high luminosity accelerator Kodai Matsuoka (Kyoto Univ.) for T2K muon monitor group.
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
SILICON DETECTORS PART I Characteristics on semiconductors.
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
Ionization Detectors Basic operation
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Analysis of Edge and Surface TCTs for Irradiated 3D Silicon Strip Detectors Graeme Stewart a, R. Bates a, C. Corral b, M. Fantoba b, G. Kramberger c, G.
Novel Semi-Transparent Optical Position Sensors for high-precision alignment monitoring applications Sandra Horvat, F.Bauer, V.Danielyan, H.Kroha Max-Planck-Institute.
Radiation Detectors In particular, Silicon Microstrip Detectors by Dr. Darrel Smith.
1 Nicolo Cartiglia, INFN, Torino - RD50 - Santander, 2015 Timing performance of LGAD-UFSD 1.New results from the last CNM LGAD runs 2.A proposal for LGAD.
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
Radiation hardness of Monolithic Active Pixel Sensors (MAPS)
9 th “Trento” Workshop on Advanced Silicon Radiation Detectors Genova, February 26-28, 2014 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica.
1 Nick Sinev, ALCPG March 2011, Eugene, Oregon Investigation into Vertex Detector Resolution N. B. Sinev University of Oregon, Eugene.
T. Lari – INFN Milan Status of ATLAS Pixel Test beam simulation Status of the validation studies with test-beam data of the Geant4 simulation and Pixel.
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
Claudio Piemonte Firenze, oct RESMDD 04 Simulation, design, and manufacturing tests of single-type column 3D silicon detectors Claudio Piemonte.
CNS CVD Diamond S. Michimasa. Properties of diamond Extreme mechanical hardness and extreme high thermal conductivity Broad optical transparency in region.
Philip Bambade, Pierre Barillon, Frédéric Bogard, Selma Conforti, Patrick Cornebise, Shan Liu, Illia Khvastunov Journée PHIL
Comparison of the AC and DC coupled pixels sensors read out with FE-I4 electronics Gianluigi Casse*, Marko Milovanovic, Paul Dervan, Ilya Tsurin 22/06/20161.
RD05 Florence CVD Diamond Radiation Sensors For Application In Very High Radiation Environments 7 th International Conference on Large Scale Applications.
RD42 Status Report W. Trischuk for the RD42 Collaboration LHCC Meeting – June 12, 2013 Development of CVD Diamond Tracking Detectors for Experiments at.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
Computed Tomography Data Acquisition
Results achieved so far to improve the RPC rate capability
Charge collection studies with irradiated CMOS detectors
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
Investigation of diamond sensors for calorimetry
Explicitly Radiation Hard Fast Gas Cerenkov Calorimeter
大強度
Radiation Damage in Silicon
HVCMOS Detectors – Overview
Simulation of signal in irradiated silicon detectors
Scintillator tile- SiPM systems R&D
Testbeam Results for GaAs and Radiation-hard Si Sensors
Semiconductor Detectors
Enhanced Lateral Drift (ELAD) sensors
Status of CCD Vertex Detector R&D for GLC
A Gedankenexperiment in Beam Profiling Kara Hoffman Mark Oreglia.
Radiation hard sensors for ILC forward calorimeter
Presentation transcript:

Kara Hoffman Mark Oreglia

A promising bolometric material: platinum high Z = large dE/dx temperature-resistivity function very steep at 20K should be more sensitive than the nickel and graphite prototypes previously tested in electron beams at Argonne Platinum TCR curve

K  beam radius Specific application: the linac test facility GEANT3 simulation Corresponding % resistivity change in bolometer strip

Bolometry summary Advantages: doesn’t disturb the beam relatively inexpensive robust Drawbacks: must be applied to absorber window for heat sinking – could be an issue mechanically/safetywise and cannot be removed or replaced small signal, particularly for more diffuse beams metal strips provide challenge in large electromagnetic noise environment large thermal time constants

Diamond is prized for more than just its sparkle (high refractive index)… low leakage I very fast readout no p-n junction needed low capacitance rad hard, strong no cooling hard insensitive to  ’s >220nm Makes a great particle detector! The RD42 collaboration (CERN) has been developing diamond (primarily) as a microvertex detector.

diamond substrate ~300  m E (>1 V/  m) sputtered metal strips/pixels (titanium coated with gold) solid electrode Ionizing radiation (36 e-h pairs per m per mip) Anatomy of a diamond substrate microstrip detector… Essentially a very compact solid-state ionization chamber.

Polycrystalline CVD Diamond growth side substrate side induced charge: dx= distance e-holes drift apart  = carrier mobility,  = carrier lifetime Charge collection efficiency effected by: grain boundaries in grain defects

Can we read out both sides of the detector? E. Milani University of Rome Naïve answer is yes, however, holes are generally less mobile than electrons. Charge collection efficiency could be much lower. Efficiency may not be an issue in a high intensity beam. Diamond has been successfully implemented as a pixel detector, but that complicates DAQ. Could flip polarity and alternate coordinates, if necessary.

Radiation “Hardness” RD42 RD42 irradiation studies our linac GEANT3 Protons in Diamond RD42 has irradiated diamond to proton fluences of and they still function

Charge threshold above which 90% of events fall Annealing “Pumping” passivates traps, actually improving charge collection efficiency up to a fluence of Collected charge (e-) RD42 Initially, smaller signals become larger and response becomes more uniform.

Electronics We have a 1 GHz bandwidth Tektronix oscilloscope with 400 ps rise time, 10 GS/s sample rate. Good enough? Power supply/amplifier: must maintain bias voltage while reading out a potentially large signal. High bandwidth: Fast electronics are desirable to exploit the excellent timing characteristics. Wide dynamic range: Large variation in intensities to be measured German nuclear scientists have developed such an amplifier DBA-II (Diamond Broadband Amplifier) – It can be done. Electronics is not a showstopper. Level of complexity depends on timing resolution desired.

A (Destructive) Test Open Questions Can we simultaneously read 2 coordinates from the same detector? How will they perform with such a large instantaneous particle flux? Will the response be linear or is there some saturation point? What kind of time resolution can we achieve? Quantify “ rad-hard ”. No one has irradiated them to a fluence where they had no signal. Place a small (1sq. cm) diamond detector with a single electrode on each side in a proton beam. Place a small (1sq. cm) diamond detector with a single electrode on each side in a proton beam. Monitor both electrodes and compare signal strength for electrons and holes. Monitor both electrodes and compare signal strength for electrons and holes. Continue until signal completely disappears. Continue until signal completely disappears. Remetalize electrodes and repeat process to determine whether the diamond is toast or the electrodes simply vaporized. Remetalize electrodes and repeat process to determine whether the diamond is toast or the electrodes simply vaporized.

Potential advantages/payoffs sensitive (2 coordinate?) measurement relatively huge signal fast (subnanosecond ~40ps) response might allow temporal beam profiling, in addition to current and position measurements free standing-accessible low Z- no beam loss (<0.1%) could be implemented quickly RD42 has already developed a vendor (DeBeers) could have broader applications: for other beams – single particle efficiency, high bandwidth make it suitable for transfer lines, etc. measuring Lab G “ death rays ” and other RF cavities

Now back to the linac test facility… Ed Black and I have sketched a robotic arm to sweep the diamond sensor through the beam Allows us to pull sensor out of the beam, thus increasing sensor life by minimizing radiation exposure. A single sensor can be used to sample the beam at several different radii, thus minimizing cost while still allowing us to make a full 3 measurement.

Diamond quality: cut, clarity = COST! Size of single crystals Density of traps Purity Polishing Uniformity of thickness and response Industrial diamond is manufactured primary for heat sinking or optics. For HEP, the figure of merit is charge collection distance. Price range: Electronics grade (P1 diamond, and others) ~$100/cm2 Tracking grade (DeBeers only) >>$1000/cm2 We don’t need single particle efficiency to see a beam. “Crappy” diamond will probably work.

Needs?$ ComponentSupplierCost 2 CVD diamond wafers: 5x5 cm each DeBeers Industrial (via U. of Toronto) Waiting for a quote from W. Trischuk 8 mm x 8 mm diamond square P1 Diamond$150 - cost goes down with volume Metal lead sputtering Rutgers U.<$300 data acquisition electronics U. Chicago- We probably don’t need this quality.

I am negotiating with RD42 to borrow/purchase a 1 sq. cm piece of “tracking grade” diamond, and I’m purchasing some electronics grade diamond for destructive test. I believe we can “beam test” (or nuke rather) some samples on a short time scale. If “electronics grade” stuff works, it could be “disposable”. This talk probably no longer belongs in an absorber review.

Extra slide: comparison of physical properties of polycrystalline and single crystal diamond