SYNCHRONOUS GENERATORS

Slides:



Advertisements
Similar presentations
3. Slip and Rotor frequency of IM
Advertisements

5. PERFORMANCE CHARATERISTICS OF IM
ENERGY CONVERSION ONE (Course 25741)
Synchronous Machines (AC Generators)
ENERGY CONVERSION ONE (Course 25741)
ENERGY CONVERSION ONE (Course 25741) CHAPTER SIX ……SYNCHRONOUS MOTORS.
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
Power System Fundamentals
Chapter 4 Synchronous Generators
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
DC Motors KL3073.
EE20A - Electromechanical Energy Conversion Induction Machine
Synchronous Machines.
ENERGY CONVERSION ONE (Course 25741) CHAPTER FIVE SYNCHRONOUS GENERATOR- CAPBILITY CURVE.
Synchronous Machine The stator is similar in construction that of a induction motor The rotor can be Salient or Non-Salient (cylindrical rotor) Field excitation.
AC Machine.
Transformers.
Transformers.
Synchronous Generator
DC motors.
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 17 AC Machines.
EQUIVALENT CIRCUIT AND POWER EQUATION OF SYNCHRONOUS MOTOR
Synchronous Motors When a synchronous machine is used as a motor, it is not self-starting. If the rotor field poles are excited by the field current and.
ENERGY CONVERSION ONE (Course 25741) CHAPTER NINE ….continued DC MOTORS AND GENERATORS.
16.11s June 2006 L s Notes for Lecture 4 Analysis of Induction Machines June 15, 2006 J.L. Kirtley Jr.
Department of Electrical and Computer Engineering
Induction Motors.
ENERGY CONVERSION ONE (Course 25741) CHAPTER SIX (& S.G. parallel op. with Pow. Sys. of chapter 5) SYNCHRONOUS MOTORS.
Synchronous Induction
ENERGY CONVERSION ONE (Course 25741) CHAPTER SIX …. Synchronous Motor Starting.
5.1 INTRODUCTION TO POLYPHASE SYNCHRONOUS MACHINES
ENERGY CONVERSION ONE (Course 25741)
Lecture 32Electro Mechanical System1 Assignment 9 Page 373 Problems 16-13, 16-16, and Due Date: Tuesday 19 th April, 2011 Quiz No.5 Next Week Quiz.
Fundamentals of Electromagnetics and Electromechanics
Lecture 32Electro Mechanical System1 Synchronous Reactance  The value of X S can be determined by measurements of the open-circuit and short-circuit tests.
Fundamental of Electrical Engineering
Induction Machine The machines are called induction machines because of the rotor voltage which produces the rotor current and the rotor magnetic field.
AC Machines Fundamentals. Introduction Synchronous machines: Motors and generators whose magnetic field is supplied by a separate dc power supply. Induction.
EET 221 Synchronous Machines Rafiqi.
Chapter 6 Synchronous Motors
Chapter 31 Lecture 33: Alternating Current Circuits: II HW 11 (problems): 30.58, 30.65, 30.76, 31.12, 31.26, 31.46, 31.56, Due Friday, Dec 11. Final.
Magnetic field due to an electric current
Induction Motors. Introduction  Three-phase induction motors are the most common and frequently encountered machines in industry -simple design, rugged,
ELEC 3105 Basic EM and Power Engineering Rotating DC Motor PART 2 Electrical.
BASIC ELECTRICAL TECHNOLOGY DET 211/3
SMJE 2103 Synchronous Generator. Scope of discussion 1)Construction 2)Rotation speed 3)Generated voltage 4)Equivalent circuit 5)Power and Torque 6)Testing.
EEE223 Energy Conversion II Md. Asif Uddin Khan Lecturer, EEE BRAC University 1.
Parul Institute Of Technology Name Of Subject:-Electrical Machines Name Of Faculty:-(1) Suresh Sahoo (2) Yogendra Tiwari E&C 3 rd Sem. Prepaid By :- Sr.No.NameEnrolment.
Synchronous Generator
TERMINAL CHARCATERISTIC of a SHUNT DC MOTOR
Lecture 31Electro Mechanical System1 Field Excitation The dc field excitation of a large synchronous generator is an important part of its overall design.
EEE223 Energy Conversion II Md. Asif Uddin Khan Lecturer, EEE BRAC University.
Lesson 12a: Three Phase Induction Motors
Hafizism february 2007 EMT462 Electrical System Technology LECTURE V mohd hafiz ismail level II jejawi.
SYNCHRONOUS GENERATOR
Voltage Regulation.
Under load-simple calculations
ECEN 460 Power System Operation and Control
Module G1 Electric Power Generation and Machine Controls
Principle of Operation
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 17 AC Machines.
Transformers. Transformer An A.C. device used to change high voltage low current A.C. into low voltage high current A.C. and vice-versa without changing.
Advanced Power Systems
Electrical Machines-II
Energy Conversion and Transport George G. Karady & Keith Holbert
EE216 Electrical Engineering
Energy Conversion and Transport George G. Karady & Keith Holbert
Principle of Operation
EET 306 Synchronous Machines
Electrical Machines (EELE 3351)
Presentation transcript:

SYNCHRONOUS GENERATORS SUBMITTED BY: Ms. JASPREET KAUR ASST. PROFESSOR-EEE

SYNCHRONOUS GENERATORS Phasor Diagram of Equivalent Circuit Voltages in Syn. Gen. are ac & expressed in phasor which have both magnitude and angle, therefore need to be presented in 2 dimensional plot. KVL relation of one phase can be plotted in terms of phasor voltages through this 2 dimensional plot named phasor diagram which show the relationship between different voltages and currents

SYNCHRONOUS GENERATORS Phasor Diagram of Equivalent Circuit Figure below show the phasor diagram when supplying a load at unity power factor EA differs from Vφ by resistive & inductive voltage drops, all referenced to Vφ which arbitrarily assumed at an angle of 0◦

SYNCHRONOUS GENERATORS Phasor Diagram of Equivalent Circuit Phasor diagram when generators operating at lagging & leading power factors

SYNCHRONOUS GENERATORS Phasor Diagram of Equivalent Circuit Note: at specific phase voltage & armature current, a larger internal voltage EA required for lagging loads than for leading loads Therefore a larger field current required with lagging loads to get same terminal voltage EA=Kφω Alternatively for a given IF and load current , Vφ is lower for lagging loads & higher for leading loads In real synchronous machines, XS normally much larger than RA & often neglected in qualitative study

SYNCHRONOUS GENERATORS Power and Torque A synchronous generator is a synchronous machine used as generator converts mechanical energy to 3 phase electrical energy Source of mechanical energy is prime mover (a diesel engine , a steam turbine, …) Any source employed should have an almost constant speed regardless of load If it were not constant, the power system frequency would wander

SYNCHRONOUS GENERATORS Power and Torque Not all mechanical power going to a synchronous generator becomes electrical power the difference between input & output power represent losses, Power flow Diagram

SYNCHRONOUS GENERATORS Power and Torque input mechanical power is shaft power in generator Pin=Тprime-mover ωm (Тprime-mover ≡ Tapp in text book) Pconv=Tgenerated ωm = 3EA IA cos γ (γ angle between EA and IA) (Tgenerated ≡Tind in text book) Difference between Pin and Pconv in generator represents mechanical, core, and stray losses of machine

SYNCHRONOUS GENERATORS Power and Torque Real elect. output power of syn. Gen. in line quantities: Pout=√3 VT IL cosθ in phase quantities: Pout=3 Vφ IA cosθ reactive power output: Qout=√3 VT IL sinθ Qout=√3 Vφ IA sinθ ignoring armature resistance RA (XS>>RA), a useful relation can be derive to approximate output power of Gen.

SYNCHRONOUS GENERATORS Power and Torque Generator Equivalent circuit for Δ connection

SYNCHRONOUS GENERATORS Power and Torque To derive that useful equation, when stator resistance ignored, phasor diagram employed

SYNCHRONOUS GENERATORS Power and Torque The vertical segment bc is EA sinδ or XS IA cosθ  IA cosθ = EA sinδ / XS Substituting this in equation of Pout  P = 3Vφ EA sinδ / XS since resistances assumed zero, losses not included in this equation (& it is both Pconv ,Pout) Above equation shows power produced by a Syn. Gen. depends on angle δ (between Vφ,EA), the torque angle Maximum power that Gen. can supply occurs when δ=90◦. At this angle sinδ=1  Pmax=3Vφ EA / XS (1)

SYNCHRONOUS GENERATORS Power and Torque Maximum power in last equation called “static stability limit” of Gen. Real or practical Gen. never get close to this limit Full load torque angles of 15 to 20◦ are typical angle of real machines If Vφ assumed constant, real power output directly proportional to IA cosθ and EA sinδ These are useful for plotting phasor diagram of Syn. Gen. as load changes

SYNCHRONOUS GENERATORS Power and Torque From chapter 4, torque developed in a Gen. can be expressed as: Тind= k BR X BS Tind=k BR X Bnet Magnitude of torque in this equation is: Тind=kBRBnet Sinδ δ: angle between rotor and net magnetic fields Since BR produces voltage EA, and Bnet produces voltage Vφ, angle δ between EA and Vφ is same as angle between BR and Bnet

SYNCHRONOUS GENERATORS Power and Torque Alternative expression for this torque in syn. Gen. is derived (employing Pconv= Tind ωm) and Equation (1): Tind=3Vφ EA sinδ/(ωm XS) (2) This equation gives torque in terms of circuit parameters, while the equation in last chapter expressed it in terms of magnetic quantities

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS Equivalent circuit of synchronous generator contains 3 quantities that must be determined to describe behavior of a real Syn. Gen. 1- relation between field current & flux (IF & EA) 2- Synchronous reactance 3- Armature resistance To determine these parameters, the first step is to do open-circuit test 1- Generator is turned at rated speed, and terminals disconnected from loads, field current set to zero 2- Field current gradually increased in steps, and terminal voltage measured at each step along the way

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS Leave terminals open IA=0, Vφ= EA and thus construct a plot of EA or VT versus IF This plot is open circuit characteristic (OCC) of Gen. With this characteristic, internal generated voltage of Gen. for any given IF can be determined typical characteristic shown 

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS Note : in this characteristic, as If increases first curve is almost perfectly linear until some saturation observed at high field current Unsaturated iron in frame of synchronous machine has a reluctance several thousand times lower than air-gap reluctance  at first all mmf is across air gap and resulting flux increase is linear When iron saturate reluctance of iron increase profoundly and flux increases more slowly with a similar increase in mmf Linear section of OCC called air-gap line

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS Second step is to perform a short circuit test 1- adjust field current to zero 2- short circuit terminals of generator through a set of ammeter 3- armature current IA or line current IL measured as IF increased 4- such a plot named short circuit characteristic (SCC) It is a straight line

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS It is a straight line, since employing the equivalent circuit developed in this section: IA= EA/(RA+jXS) Phasor diagram shown: Flux density vectors shown:

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS Bnet is very small since almost BR and BS cancels The machine is unsaturated and SCC is linear The magnitude of current: IA= EA / √[RA ^2+jXS ^2] internal Impedance of machine ZS=√RA^2+XS^2=EA/IA Since XS>>RA above relation reduces: XS≈ EA/IA =Vφ,OC/ IA (3) if EA and IA known for given situation, synchronous reactance XS can be found

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS Approximate method for determining synchronous reactance XS : 1- measure internal voltage EA open circuit test at the specific field current (OCC) 2- measure short circuit current flow IA,SC at the same field current (SCC) 3- Find XS using the approximate equation (3)

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS Concern: the EA is determined from OCC where machine is partially saturated for large field currents While IA is determined form SCC , where machine is unsaturated at all field currents Therefore at high field currents (that core is saturated in OC) EA measured from OCC at a specific If ≠ EA measured at same If under short-circuit conditions This makes resulting value of XS only approximate

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS However, answer found by this method is accurate up to the saturation point So, unsaturated synchronous reactance XS,u can be found at any If in linear portion of OCC Approximate Xs varies with degree of saturation of OCC, so it should be calculated at approximate load on machine Plot of approximate XS as function of If shown 

SYNCHRONOUS GENERATORS MEASUREMENT of MODEL PARAMETERS It is important to know winding resistance as well as synchronous reactance Resistance can be approximated by applying dc voltage to winding while machine is stationary & measuring the resultant current flow use of dc voltage means reactance of windings will be zero in measurement However, this is not perfect since ac resistance is larger than dc resistance due to skin effect Measured value of resistance can be inserted in impedance equation to improve determination of synchronous reactance, however this doesn’t help since the error due to saturation has much larger effect in Xs