OXYTRONIC 600 CONTINOUS FLOW NITROX SYSTEM

Slides:



Advertisements
Similar presentations
QUARTERLY SCBA Practice Part 1
Advertisements

Next Home µox Compact troubleshooting guide Start the slide show then click Next.
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Next Home Visio2 troubleshooting guide Start the slide show then click Next.
USER MAINTENANCE.
The EZ-SAT.
Operating Functions.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
Operating Nitrox Systems 11 Presented by Nuvair. Operating Nitrox Systems2 Membrane systems produce nitrox efficiently Compressed air flows through the.
LogTag Training January 2015
Scott 4.5 Introductory SCBA.
1 FUEL SYSTEM SERVICE ENGINE CLEAN FUEL TOOL MODEL RX 777.
HYDRAULICS & PNEUMATICS
InnoSys Process Sequence. End Effector Components End Effector Prox Switch Load Cell Wire Conduit Crows Foot Nut Runner.
Module 6 : Flow control valves
Model 754 Portable Ventilator
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
Next Home EcoCompact troubleshooting guide Start the slide show then click Next.
Fire Research Pump Boss 400 Pressure Governor
Syringe Pumps. Topics  Diagrams  Principles of Operation  Applications  Safety  Operation  Preventive Maintenance  Common Failure Modes  Troubleshooting.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
MSA - ALTAIR 4X Gas Meter.
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
Installation and Initial Start Up by Martin Noska, Service Engineer, Aftersales & Service.
Installation and Initial Start Up Worldwide Manufacturer of PSA Generators by Laco Remias, Service Engineer, Aftersales & Service.
Presented by Jon Pannell
Bmd Crossvent 3.
The UTE Speed-O-Calibration Unit (SOC) is used to calibrate the locomotive speedometer. This presentation is an operations outline for Ultra-Tech model.
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
Actuators.
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
Parts of the Anesthetic Machine
Newport HT50 Ventilator Orientation & Training
Product Introduction.
VAT: Volt Ampere Tester
AccuMax Multi-Point Injection Mechanics
1 HVACR316 - Piping Piping Applications Brazing Piping Applications Brazing.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
Electro-Pneumatics Module 1
Paver System Five Control Box Overview Aug 2009 Control Box Overview Paver System Five.
Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
EZ Reach 40 Training & Procedure Manual. Unit Capacity One of the most important considerations when operating this machine is the Bucket Capacity of.
Settings & Adjustments. Settings & Adjustments.
MSA Five Star 4-Gas Monitor Air Monitoring Instrumentation.
Engineer Training Pneumatic System Overview. Engineer Training Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:  Y Pistons.
By: Elizabeth Campbell.  Fluorescence is a useful tool for chemists to determine what wavelength of light a compound emits.  A Fluorescence Spectrometer.
1 HVACR316 - Piping Piping Applications Brazing Piping Applications Brazing.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Parts of the Anesthetic Machine A&A Pages
HOT-LOADING SAFETY TRAINING FOR THE NEPTUNE BAE 146.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
Valves In Industry (Part 1)
Tool Removed During Cycle Fault #2 Conditions for Setting Tool cocked prox switch goes open during cycle AND force on load cell drops below 5 lbs. Active.
PRO OX ® -100 Kit PROGRAMMABLE DIGITAL OXYGEN MONITOR US & FOREIGN PATENTS ISSUED & PENDING STATE-OF-THE-ART TECHNOLOGY FOR PRECISE OXYGEN MONITORING MADE.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
MACHINE OPERATION.
Quick Start Guide for Flex Flow Pump
Gas Analysis for the Recreational and Technical Diver
Laser 3000™ Operating Instructions
Digital Chart Recorder Operation
Instructions: Adding refrigerant fluid to system
System 57 Gas Control System
Compressor Operating Instructions
Presentation transcript:

OXYTRONIC 600 CONTINOUS FLOW NITROX SYSTEM COLTRI SUB OXYTRONIC 600 CONTINOUS FLOW NITROX SYSTEM

COLTRI SUB SAFETY

WARNINGS OPERATORS OF THE OXYTRONIC 600 NEED TO BE CERTIFIED GAS BLENDERS READ THE MANUAL BEFORE USING THE SYSTEM THE OPERATOR MUST STAY IN VISUAL RANGE OF THE SYSTEM THE MAXIMUM OXYGEN PERCENTAGE IS 40% OXYTRONIC 600 MUST BE MAINTAINED BY AUTHORIZED AND TRAINED PERSONNEL

ADVANTAGES OF SYSTEM OXYTRONIC 600 HAS A MAXIMUM APPLICATION OF 600L PER MINUTE NO WASTAGE OF OXYGEN LOW PRESSURE BLENDING MINIMIZES THE NEGATIVE AFFECTS OF REAL GAS LAWS SIMPLE SWITCHING BETWEEN BLENDS NO O2 CLEAN EQUIPMENT REQUIRED NO WASTAGE OF REMAINING GASES IN USED TANKS BLENDS CAN BE USED IMMEDIATELY. NO NEED TO WAIT EXTREMELY ACCURATE BLENDS CAN BE ACHIEVED

FEATURES OVERVIEW ACCUTRONIC INTELLIGENT SENSOR MAXIMUM PERCENTAGE SAFETY LIMITER MIXING RANGE ALARM NO FLOW ALARM MECHANICAL GAS VALVE EASY TO READ DISPLAY

COLTRI SUB ASSEMBLY

ASSEMBLY INSTRUCTIONS MOUNT THE STAINLESS STEEL PLATE TO THE WALL HANG THE OXYTRONIC 600 ON THE 4 MOUNTING BOLTS SCREW TO WALL HANG ON BOLT

ASSEMBLY INSTRUCTIONS ENSURE THAT THERE IS A POWER POINT NEARBY PREFERABLY WITH CURRENT SUPPLIED FROM THE COMPRESSOR. CONNECT THE POWER SUPPLY JACK PLUG TO OXYTRONIC 600 JACK PLUG

ASSEMBLY INSTRUCTIONS CONNECT THE OXYGEN CLEAN HOSE TO THE QUICK CONNECTOR OF THE OXYTRONIC 600. PUSH HOSE FIRMLY UNTILL YOU FEEL THE PIPE LOCATE QUICK CONNECT

ASSEMBLY INSTRUCTIONS CONNECT THE OTHER END OF THE OXYGEN CLEAN HOSE TO THE OXYGEN REGULATOR AND ATTACH TO O2 BOTTLE ENSURE ALL CONNECTIONS ARE CLEANED WITH COMPATIBLE CLEANING MATERIALS BEFORE CONNECTION PUSH TO CONNECT

ASSEMBLY INSTRUCTIONS CONNECT THE CORRUGATED HOSE TO THE INLET OF THE COMPRESSOR AND THE OTHER END TO THE OUTLET OF THE OXYTRONIC 600 CLAMP BOTH ENDS TIGHTLY WITH SUPPLIED CLAMPS

ASSEMBLY INSTRUCTIONS THE OXYTRONIC 600 IS NOW ASSEMBLED

COLTRI SUB SET UP

SET-UP PROCEDURES WHEN OPERATING FOR THE FIRST TIME OR AFTER CHANGING SENSORS, YOU NEED TO PAIR THE QXYGEN SENSOR TO THE OXYTRONIC UNIT PLEASE NOTE WHEN PERFORMING THE INITIAL SET –UP AS DESCRIBED IN THE FOLLOWING PAGES ANY RESIDUAL OXYGEN THAT MAYBE IN THE UNIT FROM PREVIOUS OPERATION IS TO BE FLUSHED OUT OF THE SYSTEM SO ONLY NORMAL AIR IS PRESENT IN THE INTERNAL PARTS. THIS CAN BE DONE BY RUNNING THE COMPRESSOR FOR 1 MINUTE WITH ALL OXYGEN VALVES CLOSED

SET-UP PROCEDURES BEGIN WITH ALL SWITCHES AND VALVES IN THE OFF/CLOSED POSITION ENSURE THE THE OXYGEN GAS VALVES ARE CLOSED AND THE OXYGEN REGULATOR VALVE IS FULLY UNSCREWED ANTI-COLCKWISE

SET-UP PROCEDURES CHECK POWER SWITCH IS IN THE OFF POSITION

SET-UP PROCEDURES WITH ALL SWITCHES AND VALVES CLOSED PRESS AND HOLD THE “ON/OFF” AND “PR” BUTTONS SIMULTANEOUSLY WITH BOTH BUTTONS HELD DOWN TURN THE POWER SWITCH TO THE ON POSITION CONTINUE TO HOLD DOWN THE TWO BUTTONS FOR 15 SECONDS OR UNTILL UNIT BEEPS TWICE

SET-UP PROCEDURES THE LCD SCREEN DISPLAY WILL NOW BEGIN TO RUN THROUGH A SERIES OF DIAGNOSTIC CHECKS AND SYMBOLS IF THE SET UP HAS BEEN PERFORMED CORRECTLY THE DISPLAY WILL SHOW THE CURRENT OXYGEN PERCENTAGE 20.9% THE CELL HAS NOW BEEN PAIRED WITH THE UNIT

CHECKING ELECTRO VALVE REPEAT TEST FREQUENTLY TO ENSURE VALVES ARE WORKING CORRECTLY

CHECKING ELECTRO VALVE SWITCH ON COMPRESSOR ENSURE MECHANICAL VALVE IS CLOSED ENSURE OXYGEN FLOW NEEDLE VALVE IS CLOSED OPEN O2 REGULATOR SET INTERMEDIATE PRESSURE ON O2 VALVE TO 5 BAR (SEE PAGE 32) TURN ON “ON/OFF” SWITCH RED LIGHT WILL COME ON PRESS “ON/OFF” BUTTON (GREEN FLOW LIGHT WILL COME ON)

CHECKING ELECTRO VALVE OPEN MECHANICAL GAS VALVE OPEN OXYGEN FLOW NEEDLE VALVE, O2% WILL SLOWLY INCREASE GAS WILL FLOW FROM THE OXYTRONIC 600 AND YOU WILL HEAR INTAKE NOISE OF GAS TURN “ON/OFF” SWITCH TO OFF, YOU WILL HEAR THE ELECTRO VALVE CLOSE AND OXYGEN WILL STOP FLOWING, O2 PERCENTAGE WILL DROP TO 21%

DO NOT USE HIGHER PERCENTAGES THAN 40% SETTING MAXIMUM O2% DO NOT USE HIGHER PERCENTAGES THAN 40%

SETTING MAXIMUM O2% THE OXYTRONIC 600 ALLOWS THE USER TO SET A RANGE ALARM PERCENTAGE SLIGHTLY ABOVE THE DESIRED OXYGEN FILL PERCENTAGE. WHEN THIS SETTING IS REACHED THE ELECTRO VALVE WILL AUTOMATICLY CLOSE AND STOP THE FLOW OF OXYGEN UNTILL THE PERCENTAGE DROPS 1% BELOW THE ALARM SETTING. AT WHICH POINT THE VALVE WILL RE OPEN. ALTERNATIVELY THIS ALARM MAY ALSO BE USED TO PROTECT AGAINST EXCEEDING THE MAXIMUM ALLOWABLE OXYGEN PERCENTAGE OF 40%

SETTING MAXIMUM O2% TURN ON UNIT WITH ON/OFF SWITCH. RED LIGHT WILL COME ON PRESS “ON/OFF” BUTTON FOR A FEW SECONDS UNTILL LCD READS ON AND PROCEEDS TO RUN THROUGH START UP DIAGNOSTIC. GREEN LIGHT WILL COME ON. PRESS AND HOLD “PR” BUTTON FOR 5 SECONDS. THE LCD DISPLAY WILL SHOW “PR” FOLLOWED BY “AL2” AND FINALY THE ALARM PERCENTAGE SETTING

SETTING MAXIMUM O2% TO ADJUST THIS SETTING PRESS “CAL” BUTTON, DIGITS WILL START TO FLASH USE “PR” BUTTON TO ADJUST SETTING AND “CAL” BUTTON TO SELECT DIGIT TO CHANGE WHEN THE DESIRED VALUE IS SET PRESS “ON/OFF” BUTTON, LCD WILL SHOW “END” TO INDICATE SETTING HAS BEEN SAVED NOTE, THIS SETTING REMAINS SAVED EVEN IF THE UNIT IS SWITCHED OFF

MEASUREMENT OF SENSOR DURING THE MIXING PROCESS A “REP” WARNING APPEARS ON THE LCD SCREEN WHEN THE OXYGEN SENSOR NEARS THE END OF ITS LIFE SPAN AND THE OPPERATOR IS ALERTED WITH THE FOLLOWING SIGNALS

MEASUREMENT OF SENSOR WHEN THE SENSOR IS 18% EXHAUSTED “REP” APPEARS EVERY 5 SECONDS. THIS IS ALARM 1 WHEN THE SENSOR IS 25% EXHAUSTED “REP” APPEARS EVERY 2 SECONDS. THIS IS ALARM 2 WHEN SENSOR IS 30% EXHAUSTED “REP” APPEARS PERMANENTLY. WHEN THIS WARNING IS SHOWN THE SENSOR MUST BE REPLACED AND THE NEW SENSOR START UP PROCEDURE CARRIED OUT

COLTRI SUB OPERATION

OPERATING PROCEDURES THIS PROCEDURE ASSUMES YOU HAVE ALREADY READ THE OPERATIONS MANUAL SUPPLIED WITH THE OXYTRONIC 600 AND ARE A CERTIFIED GAS BLENDER

OPERATING PROCEDURES START YOUR COMPRESSOR IN THE NORMAL MANNER CLOSE ALL THE OXYTRONIC GAS VALVES AND LEAVE OXYTRONIC 600 TURNED OFF AFTER COMPRESSOR HAS RUN FOR 1-2 MINIUTES CALIBRATE COMPRESSOR OUTPUT O2 ANALYZER TO AIR FLOW 20.9%

OPERATING PROCEDURES TURNING ON OXYTRONIC 600 TURN “ON/OFF” SWITCH TO ON RED LIGHT WILL COME ON PRESS “ON/OFF” BUTTON FOR A FEW SECONDS UNTILL LCD READS “ON” GREEN LIGHT COMES ON AND PROCEEDS TO RUN THROUGH START UP DIAGNOSTICS. PRESS AND HOLD “CAL” BUTTON FOR A FEW SECONDS. DISPLAY WILL BRIEFLY SHOW SENSOR VOLTAGE AND THEN SHOW O2 VALUE CALIBRATED TO AIR FLOW OF 20.9 % - 21%

SETTING INTERMEDIATE PRESSURE ON OXYGEN CYLINDER REGULATOR OPERATING PROCEDURES SETTING INTERMEDIATE PRESSURE ON OXYGEN CYLINDER REGULATOR BACK OFF REGULATOR “T” BAR ANTI CLOCKWISE OPEN O2 TANK VALVE UNTIL GAUGE ON RIGHT READS REMAINING GAS IN O2 TANK SLOWLY ROTATE INTERMEDIATE GAS REGULATOR “T” BAR CLOCKWISE UNTIL INTERMEDIATE PRESSURE GAS GAUGE READS 5 BAR DO NOT EXCEED 5 BAR. THIS CAN CAUSE DAMAGE TO THE O2 ELECTRONIC VALVE REMAINING GAS 5 BAR

OPERATING PROCEDURES DOUBLE CHECK OXYTRONIC NEEDLE VALVE IS FULLY CLOSED OPEN BALL VALVE BY MOVING HANDLE DOWN INLINE WITH VALVE BODY VERY SLOWLY OPEN NEEDLE VALVE UNTILL DESIRED O2 % IS REQUIRED. WHEN THE REQUIRED O2% READING IS REACHED AND STABILIZED ON THE COMPRESSOR IN LINE O2 ANALYZER YOU MAY PROCEED TO FILL CYLINDERS

OPERATING PROCEDURES CONSTANTLY MONITOR THE PERCENTAGE REQUIRED IF THE MAXIMUM O2 % RANGE ALARM SETTING IS REACHED THE RED LIGHT WILL COME ON THE ELECTRO VALVE WILL AUTOMATICLY CLOSE AND STOP THE FLOW OF OXYGEN UNTILL THE PERCENTAGE DROPS BY 1% BELOW THE ALARM SETTING, AT WHICH POINT IT WILL RE OPEN IF THE ELECTRO VALVE IS OPENING AND CLOSING THE O2 FLOW NEEDS TO BE REDUCED WITH THE NEEDLE VALVE

OPERATING PROCEDURES TURNING OFF OXYTRONIC 600 ONCE ALL TANKS ARE COMPLETED, THE USER MUST FOLLOW THESE STEPS IN ORDER CLOSE CYLINDER VALVES AND FILL COCKS CLOSE O2 TANK VALVE AND BACK OFF OXYGEN REGULATOR “T” BAR ALLOW COMPRESSOR TO RUN UNTILL INLINE COMPRESSOR ANALYZER READS 21%

OPERATING PROCEDURES TURNING OFF OXYTRONIC 600 WHEN LCD DISPLAY READS 21% CLOSE BALL VALVE CLOSE NEEDLE VALVE SWITCH OFF UNIT BY PRESSING “ON/OFF” BUTTON SWITCH OFF UNIT WITH “ON/OFF” SWITCH

OPERATING PROCEDURES NOTE IF A POWER FAILURE OCCURS, THE COMPRESSOR MUST BE RESTARTED BEFORE THE O2 CAN BE BLED FROM THE SYSTEM DUE TO THE NO FLOW SAFETY SYSTEM

ANOMALIES IN GAS BLENDING OPERATING PROCEDURES ANOMALIES IN GAS BLENDING DUE TO THE MECHANISM OF COMPRESSION O2 PERCENTAGE VALUE AT COMPRESSOR OUTPUT WILL BE SLIGHTLY LOWER THAN INPUT PERCENTAGE EXAMPLE:- A SETTING OF 36.5% ON THE OXYTRONIC WILL PRODUCE AN OUTPUT O2% OF APPROXIMATELY 36% THIS DIFFERENCE WILL VARY WITH DIFFERENT COMPRESSORS AND IS REPEATABLE ONCE ESTABLISHED

ANOMALIES IN GAS BLENDING OPERATING PROCEDURES ANOMALIES IN GAS BLENDING DUE TO RELATIVE HUMIDITY, THE ACTUAL ATMOSPHERIC O2 PERCENTAGE MAY NOT BE 20.9% PLEASE REFER TO COMPENSATION CHART IN INSTRUCTION MANUAL FOR MORE INFORMATION

COLTRI SUB SOFTWARE

BLENDING SOFTWARE THE OXYTRONIC 600 COMES SUPPLIED WITH A CD WHICH INCLUDES WITH AN EASY TO USE EXCEL FORMAT BLENDING CALCULATOR PLEASE LOOK AT THE FILE CALLED NITROX SOFTWARE.xls

e-mail: info@aerotecnicacoltriasiapacific.com COLTRI SUB This PowerPoint presentation, remains the property of COLTRI ASIA PACIFIC 94/3 Moo 3 Khaohinsorn Phanomsarakarm Chachoengsao THAILAND 24120 Tel.+66 38 855 103-5 – Fax: +66 38 855 106 e-mail: info@aerotecnicacoltriasiapacific.com internet: www.aerotecnicacoltriasiapacific.com It is prohibited to copy this presentation even partially. COLTRI ASIA PACIFIC has the right to modify this presentation without notification to customers.