FYS4250Fysisk institutt - Rikshospitalet. pH-measurement.

Slides:



Advertisements
Similar presentations
Fysisk institutt - Rikshospitalet 1. 2 Ultrasound waves Ultrasound > 20 kHz, normally 1-15 MHz i medicine When a wave is sent in one direction, it will.
Advertisements

I2 Medical imaging.
Fysisk institutt - Rikshospitalet 1 Source: Courtesy of Warner Bros Science or black magic? Chap.12 (3) Medical imaging systems: MRI.
Guillaume Lemaître François Rameau 1 Medical Imaging Techniques François Rameau Guillaume Lemaître 17th February 2009.
إعداد : أ. بلسم فهد صوفي 1 Ultrasound in Medicine Ch.3 Ultrasound pictures of the body.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
FYS4250Fysisk institutt - Rikshospitalet. Image: Grimnes, Høgetveit. Biomedical Engineering Education & Advanced Bioengineering Learning: Interdisciplinary.
Restricted © Siemens AG 2013 All rights reserved.siemens.co.uk/education Topic 15: A peep inside Siemens Education.
إعداد : أ. بلسم فهد صوفي،،،المصدر:محاضرات د.حنان 1 Ultrasound in Medicine Ch.4 Ultrasound pictures of the body.
Fysisk institutt - Rikshospitalet 1. 2 Overview Gamma camera Positron emission technology (PET) Computer tomography (CT) Proton therapy Electrical impedance.
L 35 — Modern Physics [2] X-rays How lasers work –Medical applications of lasers –Applications of high power lasers Medical imaging techniques –CAT scans.
Imaging Studies in Orthopaedics
Nuclear Medicine Spring 2009 FINAL. 2 NM Team Nuclear medicine MD Nuclear medicine MD Physicist Physicist Pharmacist Pharmacist Technologist Technologist.
3D Augmented Reality for MRI-Guided Surgery Using Integral Videography Autostereoscopic Image Overlay Hongen Liao, Takashi Inomata, Ichiro Sakuma and Takeyoshi.
Theoretical Foundations of Multimedia Chapter 3 Virtual Reality Devices Non interactive Slow image update rate Simple image Nonengaging content and presentation.
Computed Tomography. Introduced in 70’s Principle: Internal structures of an object can be reconstructed from multiple projections of the object.
Ultrasound Imaging Atam Dhawan.
Magnetic Resonance Imaging
tomos = slice, graphein = to write
CT scanning (f) Candidates should be able to show an understanding of the principles of CT scanning. (g) Candidates should be able to show an understanding.
Ultrasound Spring 2009 Student Final. Ultrasound AKA: 1)Diagnostic Medical Sonography 2)Sonography3) 4) Vascular Sonography 5)Echocardiography.
THE ULTRASOUND IMAGE: GENERATION AND DISPLAY
대구가톨릭대학병원 영상의학과 이 영 환 M M R R Basic Physics. MR Signal T1-, T2-weighted TR, TE MR Signal T1-, T2-weighted TR, TE.
Chemistry and Imaging. Body Chemistry In order to be an effective health care professional, an individual must have an understanding of basic chemistry.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
Basic Principles of Computed Tomography Dr. Kazuhiko HAMAMOTO Dept. of Infor. Media Tech. Tokai University.
Positron Emission Tomography
HIGH-INTENSITY FOCUSED ULTRASOUND By: Sahil Bilung and John Lee.
Medical Physics Physics 421 Course Description: Medical Physics is a course with two main parts:  Physics of the body  Physics of Diagnostic and Therapeutic.
Medical Imaging Technology
MEDICAL IMAGING.
3/13/2009IB Physics HL 21 Ultrasound Medical Imaging Physics – IB Objectives I.2.7Describe the principles of the generation and the detection of ultrasound.
Doppler echocardiography & Magnetic Resonance Imaging.
Ultrasound Spring 2013 Week 7 RT 255 C. Ultrasound AKA: 1)Diagnostic Medical Sonography 2)Sonography3)Ultrasonography 4)Vascular Sonography 5)Echocardiography.
Resident Categorical Course
L 36 Modern Physics [2] How lasers work Medical applications of lasers Applications of high power lasers Medical imaging techniques CAT scans MRI’s.
Diagnostic Testing  Diagnostic tests provide information about the structure and function of organs, tissues, and cells.  Medical imaging produces images.
FYS4250Fysisk institutt - Rikshospitalet....and slicky tricks to prepare you for the exam...
Lecturer name: DR ALBADR Chairman of radiology department Lecture Date: 2011 Introduction to 365 rad.
Using Radiation in Medicine. There are 3 main uses of radiation in medicine: Treatment Diagnosis Sterilization.
Introduction to Engineering and Technology Concepts Unit Five Chapter Two – Medical Technologies.
 X-Rays  Nuclear Medicine  Medical Ultrasound  Magnetic Resonance Imaging.
Display of Motion & Doppler Ultrasound
Sarah Gillies Ultrasound Sarah Gillies
Twenty Questions Subject: Diagnosis & Treatment Twenty Questions
1 INTRODUCTION TO THE PHYSICS OF DIAGNOSTIC IMAGING Outline of Course Brief History Common Terminology Imaging Modalities.
A neuroimaging technique (like a CT scan) that uses magnetic fields and radio waves to vibrate atoms in the brain’s neurons to produce and image of the.
The production of X-Rays X-Rays are produced whenever charged particles are slowed down or stopped. X-rays are generated via interactions of the accelerated.
Take Up.  Arthroscopes are a surgical tool that allow surgeons to literally see within a patient’s joints without having to surgically open the patient.
Medical Imaging How can we peer into body without cutting it open?
Echolocation III Ultrasound pictures. WHAT IS AN ULTRASOUND? Ultrasound uses energy in the form of sound waves that are of a higher frequency than the.
Methodology in the Biological Level of Analysis Learning Objectives: 1.Discuss how and why particular research methods are used at the biological level.
 This depends on a property of nuclei called spin.  Gyroscope: Principle: As long as its disc remains spinning rapidly the direction of the spin axis.
Ultrasound Learning Objectives: Describe the properties of ultrasound;
Copyright © F.A. Davis Company Chapter 5 Musculoskeletal Diagnostic Techniques.
Diagnostic Testing Martha Pyron MD N Hwy 183, Ste. 150 Austin, Texas, (512)
 Ultrasound waves are longitudinal with high frequencies ( ≈ > 20,000 Hz, though medical Ultrasound is between 1 to 15 MHz.)  When an ultrasound reaches.
Medical Physics.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
Medical Imaging. X-ray Radiography 2-D projection image created from difference in x-ray absorption rates between tissues 2-D projection image created.
Medical Resonance Imaging MRI. First medical images: X-rays Discovered in 1895 Images of bones What part of the body is this?
BY: Avantika tiwari B-tech (ece) B-1 Batch. X-ray computed tomography, also computed tomography (CT scan) or computed axial tomography (CAT scan), is.
Chap.12 (3) Medical imaging
Medical Imaging.
Medical Imaging Technologies
Medical Imaging Imagining Modalities.
Basic Principles of Computed Tomography
Computers and Technology in Health Care
Presentation transcript:

FYS4250Fysisk institutt - Rikshospitalet

pH-measurement

pCO 2 (Severinghaus) electrode

pO 2 (Clark) electrode

Fluorescent dye sensor

pH-sensitive dyes

Pulsoxymetry light absorption

Spectrophotometer

Flame emission/absorption

Fluorometer

Impedance- detector for cells

X-ray tube

Fotonspectrum X- ray tubes

X-ray system

Modulation transfer function (MTF)

Geometrical resolution

Resolution

Fysisk institutt - Rikshospitalet Non-invasive surgery Kilde: NIRS, Chiba, Japan Heavy ion therapy (Proton-terapi)

Scintillation- detector

FYS4250Fysisk institutt - Rikshospitalet

FYS4250Fysisk institutt - Rikshospitalet

X Basic principle of CT -Reconstruction of 2 dimensional image- Simple Backprojection Projection Data Blur x y x y curvilinear integral of absorption coefficient regarding Y object X-ray tube X-ray detector array Data Acquisition field Reconstruction field X X Y

Back- projection (1)

Back- projection (2)

MRI Source: Biomed resources

Precession og relaxation

Ref:

Larmour frequency The energy difference between the two alignment states depends on the nucleus  E = 2  z B o  E  h  /2    known as Larmor frequency = MHz / Tesla for proton  /2  = MHz / Tesla for proton Ref: James Voyvodic

MRI scanner

Larmorequation: ω=γB Relationship between parallell / antiparallell protones : N n /N e = e hν/kT =1+4  represents net magnetization at room temperature and 1 Tesla Important MRI equations

T 1 recording

T 2 recording

3D picture construction ω = γB

Ultrasound piezo crystal Kilde: Alejandro Frangi

Ultrasound (US), A-mode (amplitude)

Time motion US, M-mode

M-mode Ultrasound (motion)

B-mode

B-mode (Brightness) Same as A-mode, but twodimensional graphical display where brightness indicates the amplitude to reflected sound Most modern US-systems is realtime 2D or 3D. Multiple crystals or mobile crystals Up to 100 images per second

4 different probe- principles

Sources of error (1)

Sources of error (2)

Sources of error (3,4,5)

Ultrasound advantages Muscles and soft tissue are suitable for US-imaging, especially transitions between solid substances and liquid filled areas. Real time images = fast diagnosis. Can also be used for biopsy-guiding Shows the organ structure No well-known side effects, not unpleasant for the patient Small scanners compared to other image modalities Inexpensive compared to other image modalities Spatial resolution is better at high-frequency US than most of the other modalities

Ultrasound disadvantages Unable to penetrate bone tissue Poor performance where gas is present Limited operating range, dependent on the frequency High requrements for the operator, can be difficult to interpret Difficult to track back a scanned volume, as soon as the pictures are aquired no exact anchor-pile is available to navigate in the volume

Pacemaker (Asynchronous)

Demand pacemaker (Synchronous)

Atrial-synchronous pacemaker

Physiologically controlled pacemaker

Apparatus

Set-up

Hemodialysis

Kidney stone crusher

Electrosurgery

Minimal invasive surgery

Laparoscopy, advantages Less stress for the patient, short convalescence Less visible scars The procedure might be quicker Less probability for infections Less spill of blood = Less risk of need of blood transfusion

Laparoscopy, disadvantages Poor overview, more exhausting Not intuitive motions, must be transformed from a screen No control outside the visible field Instrument-collision Difficult to stop bleedings Must be able to convert to open surgery Limitations in degrees of freedom complicates surgery

Advantages focused ultrasound High accuracy (diameter of a few cells) Destroyed tissue will be re-absorbed of the body Rapid heating of the tissue will destroy the tumor Non-invasiv or minimal invasive No blood loss Repeatable Rapid convalescence Image: Trans-rectal probe (EDAP)

Disadvantages focused ultrasound Capacity problems with large tumors New and not established procedure Needs direct acoustic access to tumor The tumor must be well defined The surgeon will not have direct vision of the tissue with the tumor Possible side effects of high energetic ultrasound is not clarified (10 4 of the energy of imaging ultrasound) Require normally MR-monitoring to verify necrosis

Slicky tricks 1.When preparing for your exam, don’t get lost in details. Start with the main topics and be sure you understand them before you start to drill down in the substance 2.During the exam: Keep talking 3.If you have nothing more to say, try to direct the attention slightly to a related topic you prefer 4.All amplifiers (more or less), in this course have the same demands: High input impedance, high CMRR, protection to the organism, high gain, easy to calibrate and good frequency characteristics within the physiological spectrum 5.The main goal of this course is to obtain a breadth of outlook in this complicated field, don’t forget that. A typical question could be to compare different image modalities across all chapters. 6.If (on a direct question) you don’t know the answer, try to talk around the question while closely observing the response from both the examinator and sensor. Very often, it is possible to discuss yourself towards the answer. 7.Don’t exaggerate the consequence when you’re in, this is no execution! Take your time, breath calmly and think before you speek and we will have a nice, peaceful conversation