GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

Auto–Addressable Systems
INTRUSION ALARM TECHNOLOGY
CL100D series DSP controlled Uninterruptible power supplies.
Eagle Trading & Agencies has been established from the ground up for selling, managing and implementing mid to large size projects in the field of fire.
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
CERTIFICATON EN Wireless Fire Detection.
In this presentation you will:
HX-40/40AM 3.0m high mount outdoor detector HX-40: standard model HX-40AM: HX-40 with active IR anti-masking model confidential.
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
Protecting life, environment and property… 1 AutroFlame Detectors ID: AFLAME_X33_1_intro
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
PYRO-X De-Ice control devices Technical presentation 2013.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
Cerberus ECO – enjoy protecting
PYROCON12 De-Ice controller User Operation Presentation 2013.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Ultima® X Series Gas Monitors
SmartLine Startup.
Alarmline Linear Heat Detection
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Iris Range : «Unconventional» conventional detectors.
Addressable Fire Alarms
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
RP-2000 Series Deluge & Agent Releasing Panels
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
Fire Detection Presentation
Benefit and advantages using Iris conventional detectors range.
Enea Detectors Range.
Smart transmitters.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
HP900 (ESP Protocol) Analogue Addressable Control Panels
KIDDE FIRE PROTECTION Vega Peer to Peer Networking.
Intelligent Detection Systems l integrity of system confirmed continuously l pre-alarm facility l high flexibility of system configuration l performance.
E VERY L IFE H AS A P URPOSE… FlameGard 5 MSIR Flame Detector.
Codan 5700 Series C-Band Transceiver Technical Overview.
CB200 Conventional Control Panels
The Detection Series to Envy.
Beath High School - Int 1 Physics1 Intermediate 1 Physics Electronics Glossary AND gate to device digital signals to inverter LDR to logic circuit logic.
2 December, 2015 New Conventional Fire Control Panel.
CB200 e Cabinet Extinguishant Control Panels Designed for cabinet extinguishant systems 2 zone extinguishant co-incidence operation Selectable discharge.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Europe & Africa More Than.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
FireClass Addressable FC501 Part 2 - Panel Use. FC501 Engineering 3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
Programmable Controllers - ECL/ECB
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC PUBLIC CO900H L06 - Developing Safety Applications Using the Guardmaster®
Fire Detection Equipment and Systems in Dubai
Morley – IAS Fire Systems
Digital Light Sources First introduced in 2001.
User Operation Presentation
C1300 advanced circular chart recorder
HX-40/40AM 3.0m high mount outdoor detector HX-40: standard model
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Session III Architecture of PLC
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
The FG series of explosive and toxic gas detectors and panels
PLC Hardware Components.
Learning Outcome 4 Understand the types, applications and limitations of wiring systems and associated equipment This presentation looks at emergency management.
Presentation transcript:

GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING 2.25.2007

Fire Detection Presentation Control Panels Intelligent Fire Alarm Control Panel

Intelligent Fire Alarm Control Panel GST200 At most 30 zones. Each zone has its own alarm and fault/disable LEDs and a label. Loop capacity of 235 intelligent devices Fire and fault relay output Built-in gas extinguishing control Optional fireman’s control panel Advanced user friendly programming software including “fuzzy logic” LPCB Certification

Intelligent Fire Alarm Control Panel GST500 Large Graphical LCD display Fire and fault relay output 60 zone indication and manual intervention panel Built-in gas extinguishing control Optional fireman’s control panel Advanced user friendly programming software including “fuzzy logic” GST500/2 two loops panel can connect up to 480 devices GST500/4 four loops panel can connect up to 750 devices

Intelligent Fire Alarm Control Panel GST5000 Large Graphical LCD Display Connecting up to 4840 addressable devices Zone indication and manual intervention control expandable to 254 zones and plant overrides Built-in gas extinguishing control Optional fireman’s control panel Advanced user friendly programming software including “fuzzy logic”

Intelligent Combination Heat/Photoelectric Smoke Detector Electrically addressable Integration of photoelectric detection and fixed temperature and rate of rise detection by combining smoke sensor and heat sensor Built-in microprocessor stores 14 history data Removable innovative sensing chamber, easy maintenance; Fault self-diagnosis CE Certification

Intelligent Photoelectric Smoke Detector Aesthetically pleasing low profile design 8 bit intelligent processor with A/D converter Fire algorithms analysis to minimize false alarm High reliability, stability and coherence of the sensor Removable optical chamber for easy cleaning Maintenance LPCB , UL and CE Certification

Intelligent Digital Optical Smoke Detector NEW Advanced digital communication Electrically addressable LED’s for 360°degree vision Sensor fault self diagnosis Drift compensation Incorporated with the latest fire identification technology Self diagnosis and history log EN54 compliance

Intelligent Rate of Rise and Fixed Temperature Heat Detector Fixed temperature response is adjustable via hand held programmer between 54℃ and 80℃ 8 bit intelligent processor with A/D converter Stable and reliable performance Monitoring area: 30m2 for space height not higher than 8m LPCB and CE Certification

Intelligent Digital Heat Detector NEW Built in 8 bit microprocessor Electrically addressable LED’s for 360°degree vision Sensor fault self diagnosis Fixed temperature and rate of rise selectable EN54 compliance

Intelligent Ultraviolet Flame Detector Sensitive Ultraviolet sensor that detects the UV rays produced by a flame Not effected by sunlight Dust/corrosion/humidity resistant Standard calibration set to detect a 3cm flame at 6m Effective range 12m Stable and reliable performance

Intelligent Reflective Beam Detector I-9105R Range 8-100m, 3 selectable levels of sensitivity adjustable Combination of the emitting and receiving part makes mounting easy and optical pathway accurate Built-in microprocessor enables intelligent judgment of fire alarm and fault Self-diagnosis and automatic compensation Simple to control and operate by integrating LON works protocol SMT processing technology CE Certification

Intelligent Manual Call Point Electronically addressed Alarming by pressing, reset by a special key Non-breaking re-settable glass Providing independent normally open output contact Plug-in structure In compliance with latest EN standards

Addressable Input Module Working mode can be set to normally open, normally closed Electronically addressed The built-in microprocessor processes messages intelligently. Insulation technology for input signal, good anti-interference ability. Plug-in structure LPCB Certification

Addressable Single I/O Module Electronically addressed Insulation technology for input signal, good anti-interference ability The built-in microprocessor processes messages intelligently. Cable checking . LPCB Certification

Addressable Double I/O Module Providing two pairs of input and output contact signals. Occupying two consecutive Cable checking . Plug-in structure

Addressable Single I/O Module C-9503 C-9503 can isolate the shorted circuit from the whole system to ensure normal operation of other parts and locate the isolated part. The isolator is applicable to all kinds of loop fire alarm systems.

GST852RP LCD Repeater Panel Back lit LCD display all fire information Local sounder mute and scroll alarms buttons Two part plug-in construction with base mounted termination allows easy installation and connection Repeater can be plugged in to base at time of commissioning

Conventional Fire Alarm Control Panel GST101/102/104/108/116 1/2/4/8/16 zone conventional multi-wire fire alarm control panel Day/Night mode selectable Output delay Active connects up to 15 fire detectors Repeater is available for GST108 Resistor EOL enables multiple alarm reporting from the same zone Standby battery available CE Certification

CONVENTIONAL FIRE ALARM SYSTEM GST108 P-9907 TERMINAL RESISTOR TERMINAL RESISTOR

Conventional Fire detection wiring Resistance End of Line Note call points must be wired before detectors Active end of Line with Diode Base NOTE Call Points can be wired anywhere on circuit.

INTELLIGENT FIRE ALARM SYSTEM GST200

Fire Detection Presentation Thanks for listening