RI DEM/Office of Technical and Customer Assistance slide 1 Underground Storage Tank Management Regulations for Commercial Heating Oil Tanks RI Department.

Slides:



Advertisements
Similar presentations
Underground Storage Tanks at Duke Duke Medical Center –8 permitted USTs located on medical campus –Range in size from 2,000 gallons to 30,000 gallons Proper.
Advertisements

DISCLAIMER & INSTRUCTIONS to Class A/B Operators The slide presentation was developed to assist Class A/B Operators with providing Class C training. There.
CALIFORNIA ENVIRONMENTAL REPORTING SYSTEM TRAINING FOR BUSINESSES Contra Costa County Hazardous Materials Programs.
Installer Certification NMAC The effective date for certified installer requirements for performing UST system installations or repairs in New.
Storage Tank Committee Meeting April 23, 2003 Santa Fe, New Mexico New Mexico Environment Department Petroleum Storage Tank Bureau.
Rhode Island’s Underground Storage Tank Program
 The Federal Clean Water Act specifies the requirements for SPCC Plans  The Code of Federal Regulations 40 CFR 112 details requirements of the SPCC.
Our Vision – Healthier Kansans living in safe and sustainable environments.
ENVIRONMENTAL LAWS, REGULATIONS, PRACTICES, PUBLIC SAFETY ► CHAPTER 17 © 2009 South-Western, Cengage Learning.
Who Will Regulate my Food Business? John E. Rushing, Ph.D. Department of Food Science NCSU.
Petroleum Equipment Institute
Southwest District Storage Tanks Program presented by Leslie Pedigo Southwest District Storage Tanks Program presented by Leslie Pedigo.
ECE II Objective 2.01 Interpret licensing requirements for early childhood programs.
Nassau County Underground Oil Tank Requirements
Managing Environmental Issues with Hospital Expansion Projects Tank, Generator, and Boiler Installations from an Environmental Permitting Perspective Chris.
1 MASSACHUSETTS UNDERGROUND STORAGE TANK (UST) PROGRAM Baseline Compliance Assessment 1 MassDEP 8/2/2011.
ACCA Legislative Conference Underground Storage Tank Compliance
Licensing of Nuclear Power Plants in Pakistan
Assessing Your School An Environmental Investigation You have been hired by Eagle Environmental, Inc. to perform an Environmental Assessment of South Hunterdon.
SPILL PREVENTION CONTROL AND COUNTERMEASURE (SPCC) Title 40 CFR 112.
Solano County Department of Environmental Management Environmental Health Services Division Hazardous Materials.
OPERATOR, Tester & INSTALLER Licensing WWQRR, Chapter 17, Part L
Massachusetts Department of Environmental Protection Drinking Water Program.
MassDEP Stage I Vapor Recovery Program
MassDEP Underground Storage Tank Program Program Requirements for Third Party Inspectors Winter 2015 Workshops.
Release Reporting. Lesson #17 - Release Reporting How Do I Know If I Have a Leak in My UST System?
Georgia Environmental Protection Division Stage II Gasoline Vapor Recovery Decommissioning Workshop June 11, 2014 EPD Tradeport Training Room.
Matthew Udenenwu Waste Permits Division 2015 TCEQ Environmental Trade Fair.
Idaho Solid Waste Facility Record Keeping June 20, 2006 Idaho Department of Environmental Quality.
Also known as the Storage Tank Act of Which of the following tanks is not a regulated tank? a. An farm underground storage tank (UST) that contains.
U.S. Environmental Protection Agency Office of Emergency Management Regulation and Policy Development Division Proposed Amendments to the Spill Prevention,
Policy and Legal Framework on Soil Contamination Management in Thailand Workshop on Strengthening Contaminated Soil Monitoring in Vietnam, November.
APPLICATIONS OF WATER QUALITY REGULATIONS Module 22, part c – Applications.
March Why is MassDEP proposing new UST regulations? DFS’s regulation: standards for tanks construction, installation, O&M, decommissioning and.
MassDEP Underground Storage Tank Program Program Requirements for Owners and Operators Winter 2015 Workshops 1.
ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks.
Prepared for Middle Georgia State University – Macon Campus Prepared by Geotechnical and Environmental Consultants, Inc.
Commercial Project Reviews Information to assist with your project.
REPLACING, REMOVING, OR UPGRADING UNDERGROUND STORAGE TANKS (RUST) PROGRAM Janice Clemons, RUST Program Manager.
Workshop on Permanent Closure of Single-Walled USTs and Funding Opportunities For Closure and Cleanup.
Staying in Compliance Inventory Control Bill Greer GTEC.
BY: Winston G. Smith Environmental Engineer UST/PCB & OPA Enforcement & Compliance Section EPA Region 4.
Joe Stapinski Senior UST Inspector (317)
Overview of 3 rd Party Inspection Program for USTs.
CABLING SYSTEM WARRANTY REGISTRATION. PURPOSE OF CABLING REGISTRATION.
Outreach for the On-Call Hazardous Waste Site Investigation and Design Services Contract Caltrans D9 February 17, 2016.
| Excellence. Value. Get There!™ Aboveground Storage Tanks David L. Yaussy, Spilman Thomas & Battle, PLLC.
Release Reporting. How Do I Know If I Have a Leak in My UST System? 1. Unusual operating conditions; such as, erratic behavior of the dispensing pump.
Division of Waste Management Dexter R. Matthews, Director Mission: to prevent harmful releases of waste to the environment and clean up existing contamination.
Permit Process & Application Guide
EXCALIBUR GROUP, LLC Evolving Regulations for USTs in New York For New York State August 1, 2013.
1 Final Rulemaking - Chapter 245, Administration of the Storage Tank and Spill Prevention Program (Subchapters A-H) Environmental Quality Board Meeting.
Things Aren’t Always What They Seem A Stormwater Pollution Prevention / Good Housekeeping Case Study in Western New York.
UST Inspection Program
Advanced Environmental Management (AEM) Training Phase I
New Licensing and Renewal Requirements
Release Reporting Lesson 17 covers the subject of Release Reporting. You will learn how you know when you have a leak and what leaks require reporting.
Underground Storage Tanks New Federal 2015 Requirements
Petroleum Storage Tanks – Program Updates
July 13, 2016 Department of Environmental Quality Proposed Amendments to UST Rules 15A NCAC 02N and 02O Ruth Strauss.
New Install Proposed rule changes
September 8, 2016 Department of Environmental Quality Proposed Amendments to UST Rules 15A NCAC 02N and 02O Ruth Strauss.
GTEC 2017 Annual UST Management & Compliance Assistance Seminar
Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective – 1/11/2017.
Spill Prevention Control and Countermeasures
Solano County Department of Environmental Management Environmental Health Services Division Hazardous Materials.
COMPLIANCE VIOLATIONS FOUND DURING INSPECTIONS
Air and Water Management Association Regulatory Conference Symposium
Petroleum Storage Tanks – Program Updates
Annual Enforcement Report Overview
Presentation transcript:

RI DEM/Office of Technical and Customer Assistance slide 1 Underground Storage Tank Management Regulations for Commercial Heating Oil Tanks RI Department of Environmental Management

Disclaimer The purpose of this session is to provide you with a general overview of certain regulatory requirements. As such, the remarks offered by DEM representatives are merely intended as opinions, offered to assist you in understanding how the regulations may be applied in general. These opinions should not be taken as attempts to apply the regulations to specific factual scenarios. They are offered without familiarity with all of the facts presented by a given situation and, therefore, you should not act in sole reliance upon the opinions provided. Specific questions about the application of environmental regulations to individual cases should be directed to the Department’s Office of Technical & Customer Assistance, or to the Office of Waste Management, UST Section. Nothing said today should be taken as being binding upon the Department- neither the Department’s interpretation of applicable regulations, nor any policy which may have been developed through applying those regulations.

RI DEM/Office of Technical and Customer Assistance slide 3 What is a UST? l 10% or more of its volume (including piping) is underground l Holds petroleum product or hazardous material l Also includes holding tanks serving floor drains

RI DEM/Office of Technical and Customer Assistance slide 4 Why regulate USTs? l Small leaks of petroleum products or hazardous materials from USTs can contaminate large groundwater supplies l Leaks can also create health and fire hazards in nearby buildings

RI DEM/Office of Technical and Customer Assistance slide 5 Program Elements for Heating Oil USTs l UST Registration l Existing System Requirements –Spill Protection –Leak Detection –Abandonment Prohibition –Tank Closure l New/Replacement Tank Standards –New Installation Standards

RI DEM/Office of Technical and Customer Assistance slide 6 UST Registration l USTs storing fuel oil for heating commercial facilities must be registered with DEM - including schools l Commercial USTs storing motor fuel or hazardous materials must also be registered –includes waste oil USTs –includes holding tanks serving floor drains

RI DEM/Office of Technical and Customer Assistance slide 7 UST Registration (cont’d.) l Annual fee- $50 per tank (municipalities exempt); DEM issues annual certificate l Application provides information on tank system age, construction, contents and ownership

RI DEM/Office of Technical and Customer Assistance slide 8 Existing System Requirements- Spill Protection l Spill containment required on all registered USTs since January 1, 1993 –three gallon capacity –above-ground fills exempt

RI DEM/Office of Technical and Customer Assistance slide 9 Existing System Requirements- Leak Detection l Leak detection is not specifically required for USTs holding heating oil for on-site consumptive use l DEM recommends periodic tightness testing, and other inventory controls, as good management practices –DEM licenses testers and approves test methods l All releases must be reported immediately to DEM, the local water supplier (if sensitive area), and the local fire authority

RI DEM/Office of Technical and Customer Assistance slide 10 Existing System Requirements- Abandonment Prohibition l Abandonment means the relinquishment or termination of possession, ownership or control of USTs, by vacating or by disposition, without meeting the closure requirements...; or the action of taking a UST or UST system out of operation for a period of greater than 180 consecutive days without the prior permission of the Director... l No UST may be abandoned- there are no exceptions l Extensions may be granted on a case-by-case basis (temporary closure)

RI DEM/Office of Technical and Customer Assistance slide 11 Existing System Requirements- Tank Closure l Closure of commercial tanks must be pre-approved by DEM –$75 application fee l DEM conducts inspection of excavation –must schedule closure inspection l Residues must be managed appropriately –must be transported off-site by permitted hazardous waste transporter l Tank must be cut/cleaned per Fire Marshal’s regulations l Closure Assessment only required for motor fuel USTs l Closures-in-place only approved under special conditions

RI DEM/Office of Technical and Customer Assistance slide 12 New Installation Standards l Application must be submitted to DEM l Must be approved before installation l New UST facilities may not be constructed in wellhead protection areas (replacement tanks are allowed) l Substantial modifications of UST systems must also be pre-approved l USTs serving floor drains have special requirements

RI DEM/Office of Technical and Customer Assistance slide 13 New Installation Standards (cont’d.) l Tanks must be double-walled, steel tanks must have corrosion protection l Piping must be double-walled, with containment sump l UL or ULC listed, National Codes of Practice l Entire system precision tested upon installation l Spill containment and overfill protection required

RI DEM/Office of Technical and Customer Assistance slide 14 General Approval Process l Submit scope of work to DEM thirty (30) days in advance l Written approval from DEM required prior to commencement of work ( including product piping replacement ) l Notify DEM 48 hours prior to installation l Written verification of completion within fifteen (15) days

RI DEM/Office of Technical and Customer Assistance slide 15 Installation Paperwork l completed registration application l detailed site plan (plans for new facilities require PE stamp) including location of: –all tanks and piping –dispensing units –groundwater monitoring wells –water table elevation –public water supply wells or reservoirs within 400’ –facilities served by private wells within 200’ –proposed and existing buildings and associated structures –boundaries of the facility –north arrow

RI DEM/Office of Technical and Customer Assistance slide 16 Installation Paperwork (cont’d.) l Cross-sectional view of the tank –depth of excavation –bedding thickness –backfill depth –supports and anchorage used –dimensions and thickness of traffic pad l Equipment list and written description –tank(s) –piping –leak monitoring systems –spill/overfill protection methods –corrosion protection methods –operation and maintenance requirements for any of the above

RI DEM/Office of Technical and Customer Assistance slide 17 UST Professional Certification l Individuals who conduct precision tests must now be licensed by DEM l Installers must be licensed by RI Dept. of Labor/Division of Professional Regulation, and certified by applicable equipment manufacturers l DEM encourages voluntary efforts by UST installers, removers, and corrosion protection experts to obtain certification from a non-profit testing agency- the International Fire Code Institute –we hope to make this certification mandatory

Self-Audit Checklist  Are all your USTs registered?  check DEM registration database  make sure registration fees are paid in full  Make sure required documentation is submitted  spill containment installation notices  Plan for replacement  remove/replace (old) tanks  evaluate new storage technology- UST vs AST  Gasoline or generator fuel USTs? Leak detection, 1998 upgrade requirements, and others apply

RI DEM/Office of Technical and Customer Assistance slide 19 l What about above-ground storage tanks? –ASTs are regulated by DEM –Installations are approved by local authorities l What about the 1998 upgrade requirements? –These only apply to motor fuel USTs, and fuel oil distribution USTs. l What about financial responsibility? –This is only required for motor fuel USTs, and fuel oil distribution USTs. Questions and Answers

RI DEM/Office of Technical and Customer Assistance slide 20 Any questions? Call us at OTCA (6822) Tom Epstein- ext fax UST Program Eric Beck- ext fax

RI DEM/Office of Technical and Customer Assistance slide 21 or visit the Office of Technical & Customer Assistance at our new home- l 235 Promenade Street Providence, RI l first door on left from the Beach Street entrance