MEMS in the Market – Design and Market Analysis MEMS in the Market – Design and Market Analysis Ryan Dempsey, Peter Shanahan, John Richardson, Rachel Weaver,

Slides:



Advertisements
Similar presentations
I have seen this happen !. You have exceeded your storage allocation.
Advertisements

Device Design and Fabrication Using lithography techniques, a Y-channel master was fabricated with SU8 photoresist. Master on Silicon With this master,
Design and Simulation of a MEMS Piezoelectric Micropump Alarbi Elhashmi, Salah Al-Zghoul, Advisor: Prof. Xingguo Xiong Department of Biomedical Engineering,
Microfluidic Glucose Sensor Senior Design Group 4 Kristen Jevsevar Jason McGill Sean Mercado Rebecca Tarrant Advisor: Dr. John Wikswo, Dr. David Cliffel.
Fall 2014, Prof. JB Lee Ion Sensitive FET (ISFET) - What and Why?
Drug Delivery & Tissue Engineering Laboratory
Figure 7 Design and Simulation of a MEMS Thermal Actuated Micropump Shiang-Yu Lin, Huaning Zhao, Advisor Prof. Xingguo Xiong Department of Biomedical Engineering,
Microfluidic Valve Innovation Jo Falls Porter, RET Fellow 2009 West Aurora High School RET Mentor: Dr. David T. Eddington, PhD NSF- RET Program Introduction.
MONOLITHIC 3-D MICROFLUIDIC DEVICE FOR CELL ASSAY WITH AN INTEGRATED COMBINATORIAL MIXER 陳睿鈞 Mike C. Liu, Dean Ho, Yu-Chong Tai Department of Bioengineering,
The use of materials patterned on a nano- and micro-metric scale in cellular engineering C.D.W. Wilkinson, M. Riehle, M. Wood, J. Gallagher, A.S.G. Curtis.
Zarelab Guide to Microfluidic Lithography Author: Eric Hall, 02/03/09.
Basic Silicone Chemistry (II)
Development of a Modular Peristaltic Microfluidic Pump and Valve System 3/13/2007 BME 273 Group 20: Adam Dyess, Jake Hughey, Michael Moustoukas, Matt Pfister.
Presentation Short Title
A Bandwidth Detection System to Monitor Single Cells Jerry J. Wilmink, Jonathon D. Wells, Advisor: Franz Baudenbacher Department of Biomedical Engineering.
Device Design: Stage 2 (Modified Microchannel Design) Device Objective –To test the viability of a two-level passive micro-fluidic device Modifications.
Microfluidics Technology Fair, October 3, 2006 Parallel Integrated Bioreactor Arrays for Bioprocess Development Harry Lee, Paolo Boccazzi, Rajeev Ram,
Microfluidic System for Automatic Cell Culture Chun-Wei Huang, Song-Bin Huang, Gwo-Bin Lee Department of Engineering Science, National Cheng Kung University,
BGU Physics Department: Going with the (Laminar) Flow
State-of-the-art probes Alan Bigelow Alternative sensing methods Real-time, single-cell analysis techniques.
Global Microfluidics Market Future Market Insights
Alex Makowski Michael Hwang Jenny Lu Dr. John Wikswo
 Idea: To characterize a simple model of the microvascular system using a microfluidic device  Potential Uses:  Simulate clot, stroke, plaque buildup.
Flow cell design for WGM optical biosensor Yongqiang Yang BE8280 spring 2015.
Prototyping Techniques: Soft Lithography
BIOMICROFLUIDICS May 12, 2003 Final Report Susan Beatty Stacy Cabrera Saba Choudhary Dan Janiak
Development of a Modular Microfluidic Peristaltic Pump and Valve System Jacob Hughey ¶, Matt Pfister ¶, Adam Dyess ¶, Michael Moustoukas ¶ Advisor: John.
BioSensors Yang Yang 9/28/2004. Outlines BioMEMS Enzyme-coated carbon nanotubes Microcantilever biosensor with environmentally responsive hydrogel Cantilever.
Minibioreactors -> Volumes below 100 ml Characterized by: -> area of application -> mass transfer -> mixing characteristics.
Instrumented NanoPhysiometer for High Throughput Drug Screening D. Michael Ackermann, Jon Payne, Hilary Samples, James Wells.
Device Design: Stage 2 (Modified Microchannel Design) Device Objective –To test the viability of a two-level passive micro-fluidic device Modifications.
Chip Lid Molding ENGR Pre Lab. Micro-fabrication  How can we produce devices on a very small scale ?  e.g. Device dimensions 10 nm – 400 µm.
Design Team 8: Fluorescent Detection using Optical Fibers with Cardiac Myocytes Team Members: Paul Clark Martin Garcia Chris Gorga John Ling III Giordano.
BME 273 Senior Design Project Group 25 “MEMs in the Market”
Group 3: Microfluidic System for Galvanotaxis Measurements Team Members: Arunan Skandarajah and Devin Henson Advisors: Dr. Janetopoulos, Dr. John Wikswo,
Water toxicity detection through perfusion and monitoring of living cells on a microfluidic chip Fang Li, Ph.D. Department of Mechanical Engineering New.
BME 273 Senior Design Project Group 25 “MEMs in the Market”
Optimization of T-Cell Trapping in a Microfluidic Device Group #19 Jeff Chamberlain Matt Houston Eric Kim.
Process Sequence: Pressure-Actuated Valve ENMA490 October 14, 2003.
BioMEMS: Microfluidics Optimization & Cell Culture Maintenance D. Michael Ackermann, John Payne, Hillary Samples, James Wells Group # 23 Advisor: Franz.
Fully-integrated microfluidic chips capable of performing DNA amplification from RNA virus, sample transportation, capillary electrophoresis separation,
FLUORESCENT DETECTION USING OPTICAL FIBERS WITH CARDIAC MYOCYTES DESIGN GROUP EIGHT FLUORESCENT DETECTION USING OPTICAL FIBERS WITH CARDIAC MYOCYTES Paul.
MRS Entrepreneurship Challenge: Lab-on-chip Sensor Technology Presented on December 6, 2005.
Harmful algal bloom (HAB)-on-a-chip: Development of a microfluidic platform to study algal chemotaxis Kelly O’Quinn Dr. Adam Melvin Cain Department of.
Instrumented NanoPhysiometer for High Throughput Drug Screening D. Michael Ackermann, Jon Payne, Hilary Samples, James Wells.
Optimization of T-Cell Trapping in a Microfluidic Device Group #19
C A microfluidic device was created in order to mix the contents of two reservoirs through a 200um-wide, 30mm-long diffusion channel. Flow Characterization.
MICROCHANNEL DESIGN ISSUES Susan Beatty Anne Samuel Kunal Thaker.
Microfluidic Glucose Sensor Senior Design Group 4
Integrated Microfluidic Systems for Automatic Glucose Sensing and Insulin Injection 1 Chao-June Huang, 2 Chih-Hao Wang, 3 Yi-Hsin Chen, 3 Tse-Chuan Chou.
Development of Microfluidic Glucose Sensors BME 273: Kristen Jevsevar, Jason McGill, Sean Mercado, Rebecca Tarrant Advisors: Jennifer Merritt, Dr. John.
Tracking and Probing Single, Diffusing Molecules in Droplets Mark Arsenault, Peker Milas, Ben Gamari, Richard Buckman, Lori Goldner Biophysics Group MiniSymposium.
Microfluidic Glucose Sensor Senior Design Group 4 Kristen Jevsevar Jason McGill Sean Mercado Rebecca Tarrant.
Lab-on-Chip Workshop March 25, 2016 Eric Johnston Soft Lithography Manager Quattrone Nanofabrication Facility.
Microfluidic generator of sub-10-micron hydrosomes Zhenghao Ding, Lunjun Liu, Gabriel C. Spalding* Physics Department, Illinois Wesleyan University Abstract.
Fluorescent Detection using Optical Fibers with Cardiac Myocytes Paul Clark Martin Garcia Chris Gorga John Ling III Giordano Lo Regio.
Microfluidics & The Field of Bioengineering
How small is nanotechnology? lessons outline Integrated Circuits and 45nm linewidths (2007 ETP – lesson day 1) What are MEMS? (lesson day 2) Common uses.
Figure 1: Potential sensor behavior; As the CO 2 levels drop in the chamber, the output voltage drops Figure 2: Response of circuit to CO 2 sensor input.
Lactate Sensor Design: Smart Gels for Diabetes Pre-screening
Kathryn Rose Verfaillie with Dr. Nivedita Gupta and Brian Zukas
Live Cell Imaging Chamber
BME 273 Senior Design Project Group 25
A Bandwidth Detection System to Monitor Single Cells
Molding PDMS Channels and an Embedded Detector Chamber
3-Valve Pumping Sequence 4-Valve Pumping Sequence
Determination of Intercellular Calcium Concentrations in Cardiac Myocytes Using Fluorescence and a Single Fiber Optic Method Paul Clark, Martin Garcia,
Applications and Acknowledgements
Determination of Intercellular Calcium Concentrations in Cardiac Myocytes Using Fluorescence and a Single Fiber Optic Method Paul Clark, Martin Garcia,
Presentation transcript:

MEMS in the Market – Design and Market Analysis MEMS in the Market – Design and Market Analysis Ryan Dempsey, Peter Shanahan, John Richardson, Rachel Weaver, Charles Bloom Advisors: Franz Baudenbacher, Ph.D. 1 ; Raghav Venkataraman; Paul King, Ph.D. 1 1 Department of Biomedical Engineering, Vanderbilt University, Nashville, TN Background BioMEMS Cell Culture Device Fabrication Release and Bind GLASS PDMS PDMS Casting and Curing PDMS SILICON Exposed and Developed Photoresist SILICON Spin Photoresist onto Silicon Wafer SILICON PHOTORESIST Device Testing Market Barriers The NPV of our project is $6,612,618 for the period between 2001 and Therefore, we should accept the project because it is profitable. Project Valuation Objectives Future Directions Market & Demand Cost Savings The market for our BioMEMS device includes companies involved in one of two related industries: (1) major drug manufacturing, and (2) drug delivery. Major pharmaceutical companies spend an average of $802 million and 10 to 15 years researching and developing a drug to come to the market The following is a list of our device’s primary design innovation factors that improve on the most current designs: Circular wells to allow user-friendly cell insertion and perfusion Dual-chambers to allow independent experiments on a single chip Disposable and low per-unit cost Unit cost of our device is approximately $3 per chip (beginning in 2008). The market potential for lab-on-chip (LOC) devices used in drug development and delivery is massive! United States Microfluidics/LOC revenue forecasts Current Method Establish screening goal of 100 active compounds. Order any 100,000 compounds. (Internal inventory or vendor.) Screen 100,000 compounds to identify active compounds. Expect 100 hits with present hit rate of (100,000 compounds) x (.001) = 100 hits CURRENT HTS COSTS FOR THIS ASSAY: (# of compounds screened) x (cost per compound) = 100,000 x $1.50 = $150,000 Total cost: $150,000 Number of Hits: 100 Order any 10,000 compounds. (Internal inventory or vendor.) Screen 10,000 compounds to identify active compounds. Our BioMEMS Device Establish screening goal of 100 active compounds. Expect 100 hits with present hit rate of (10,000 compounds) x (.01) = 100 hits ASSAY COSTS USING OUR DEVICE: (# of compounds screened) x (cost per compound) = 10,000 x $5.00 = $50,000 Total cost: $50,000 Number of Hits: 100 Total cost using current HTS method = $ 150,000 Total cost using our bioMEMS device = $ 50,000 TOTAL SAVINGS FOR ONE ASSAY = $ 100,000 The most significant barriers to market entry include: Interfacing concerns: nano- versus macro- Lack of silicon flexibility Replacing old systems with new technologies Lack of BioMEMS technological standard Government regulation (Class I device) Our device increases cost savings by… Increasing the hit rate of discovered compounds Reducing # of ordered compounds for testing Reducing reagent cost Our device has great potential in the market Market share is anyone’s “game” Cell-scaled beads can correctly perfuse The future of our device’s design will be in bio-sensing. We can now pass our project on to future design groups to add bio-sensors to our design Corporate Environment The market is young and fragmented The top five companies account for approximately 48% of the total LOC market in Caliper, Cephoid, Agilent, Combimatrix, and Nanogen Inc. Initially, our forecast market share = 1% CompanyLOC Device Name(s)Market Share Public/Private Caliper Life Sciences LabChip17%Public CepheidSmartCycler; GeneXpert10%Private Agilent Technologies HPLC Chip; 2100 Bioanalyzer; 5100 Automated LOC 9%Public CombiMatrix Corp. CustomArray7%Public Nanogen, Inc.NanoChip5%Public 1.Technology Design and fabricate dual cell culture micro-electro-mechanical system (MEMS) device in order to allow for multiple experiments on single chip Design enclosure in order to allow gas permeability to simulate in-vivo environment Design the device to be capable of allowing both nutrient and drug perfusion via different pathways in order to provide drug testing capabilities Design device with pneumatic valves in order to prevent cellular relocation Device should hold pico-liter volumes and have channel diameters >30 microns Design device to be low cost and disposable 2.Business To create a business proposal in order to market our technology to venture capitalists Large scale bioreactor for experimenation Micro-sized BioMEMS device for experimentation Courtesy of Raghav Venkataraman Advantages over conventional Petri dish Higher cell-to-volume ratio MEMS devices can have on-chip sensors unlike Petri dishes Allows detection of cell metabolism changes more accurately due to more sensitive detectors for smaller concentration changes Advantages over conventional bioreactors Conventional bioreactors require large amounts of physical laboratory space which MEMS devices do not Substantially lower cost Reduced experimentation setup time Reduced sensing time of metabolic activity from smaller volumes Spin SU-8 photoresist onto silicon wafer Pre-Bake SU-8 Expose using mask below with UV light “Post-Exposure” bake Develop SU-8 photoresist Hard Bake Cast and cure PDMS on master Remove PDMS device from master Bind upper pneumatic PDMS layer to lower cell culture PDMS layer using bake Punch insertion holes for fluidics channels in PDMS device Seal entire PDMS device to glass slide using plasma oxidation AutoCad drawings of actual masks used for fabrication with the device on left and pneumatic valves on right. Biological MicroElectroMechanical Systems (BioMEMS) MEMS devices are micro-sized devices used in a wide variety of applications from automobiles to cell culturing in order to provide sensor and cultures at a reduced size Bio-MEMS devices are designed to use very small volumes which translates to significantly fewer supplies for experimentation The significantly fewer supplies and the low cost of actual devices has potential to substantially cut costs Micro-beads A diluted solution of beads was mixed using water The solution was then drawn into a syringe The syringe was connected to plastic tubing lines which were then connected to the device inlet ports Following this the bead solution was run through the device in order to check for structural integrity and to assure that none of the fluidic lines were sealed to the underlying glass slide Image of beads flowing through device taken through Zeiss microscope and digital camera Device Dimensions Integration of multiple sensors to the cell culture area for rigorous analysis of cell metabolism and reaction to drug Oxygen sensor pH sensor CO2 sensor Lactate sensor Glucose sensor Schematic above shows future direction of device. Courtesy of Dr. Baudenbacher Cell culture = 600 x 600 um Perfusion channels Maximum = 200 microns Minimum = 100 microns Current drug development costs Markets for microfluidic devices