June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 1 The IEEE1394 Test Board Results Measurements with a Vector Network Analyzer (VNA) type HP 8753D.

Slides:



Advertisements
Similar presentations
Fixture Measurements Doug Rytting.
Advertisements

A Wireless Local Area Network (WLAN) is a network that interconnects devices using radio waves. Wireless networking technologies allow devices to communicate.
PML Semiconductor Electronics Division, NIST
Doc.: IEEE /0346 Submission March 04 Niels van Erven, 3ComSlide 1 Proposal how to measure RF sensitivity for WPP Niels van Erven 3Com.
Measuring High-Frequency Networks and Components using Vector Network Analyzers Giovanni D’Amore Welcome to “Measuring High-Frequency Networks and Components.
Jiaru Shi(Department of Engineering Physics, Tsinghua University) Hao Zha (CERN) CLIC Workshop 2014 CLIC choke mode structure and X-band activities.
AB 11 22 33 44 55 66 77 88 99 10  20  19  18  17  16  15  14  13  12  11  21  22  23  24  25  26  27  28.
Prof. David R. Jackson Dept. of ECE Notes 16 ECE Microwave Engineering Fall 2011 S -Parameter Measurements 1.
Coaxial Measurements – Common Mistakes & Simple Solutions Sathya Padmanabhan Rocky Teresa Maury Microwave Corp. For electronic copy of presentation go.
Agenda l Overview of RF Design Process l Case study: RF Front-end : Low-noise amplifier (LNA) : Duplexer : Power amplifier l Measurement for Design : Passive.
EEE194RF_L12a1 Low Freq Common-Emitter BJT Model Model is the hybrid-  BJT model where r BE = r , r BC = r , and r CE = r o.
ELEC Lecture 91 ELEC 412 RF & Microwave Engineering Fall 2004 Lecture 9.
Introduction (or Why Make Transmission Line Measurements?) A transmission line (or cable) transfers electrical energy from one point to another. Time delay.
Learning Outcomes  Know the basic components of a network  Know data transmission methods, including types of signals, modulation, demodulation, and.
Harbin Institute of Technology (Weihai) 1 Chapter 2 Channel Measurement and simulation  2.1 Introduction  Experimental and simulation techniques  The.
What is a Computer Network? Two or more computers which are connected together.
TRF Noise Floor Related Question Prepared by Bill Wu.
2.4GHz Single Balanced Mixer Andrew Bacon Jacqueline Griffin John Stone.
Coaxial cables measurement Identification method of damaged cables or bad connectors mounting Stéphane Rey – BE/RF – September.
Exercise. Try this A 100-Ω transmission line is connected to a load consisting of a 100-Ω resistor in series with a 10pF capacitor with 100Mhz signal.
Single Ended Measuring Modes of ELQ 30A To learn more click on the selected topic! ELEKTR NIKA Receiving Modes Impulse Noise Measurement Spectrum Analyzer.
Network Analyzer Error Models and Calibration Methods by Doug Rytting
F. Caspers, S. Federmann, E. Mahner SPSU meeting, 27 th October 2009.
Introduction to 85108A Pulsed Network Analyzers Pengcheng Jia Dec 13, 2001.
Doc.: IEEE d_Intra-Device_Propagation_Measuremets Submission March 2015 Slide 1 Project: IEEE P Working Group for Wireless Personal.
Using Transmission Lines III – class 7 Purpose – Consider finite transition time edges and GTL. Acknowledgements: Intel Bus Boot Camp: Michael Leddige.
First results from PADI-2 Mircea Ciobanu CBM Collaboration Meeting March 10 –13, 2009 GSI-Darmstadt FEE1.
RFI Mitigation for Electronic and Natural SKA Environment Philip Kibet Prof HC Reader Stellenbosch University SKA Postgraduate Bursary and Postdoctoral.
Bench measurements of the PS fast wire scanner Jean-Luc Nougaret, Olav Berrig and Hugo Day with special thanks to Benoit Salvant and William Andreazza.
Network Analyzers From Small Signal To Large Signal Measurements
The 2008 SPS electron cloud transmission experiment: first results F. Caspers, E. Mahner, T.Kroyer Acknowledgements to B. Henrist, J.M. Jimenez, J.M. Laurent,
University of Kansas 2004 ITTC Summer Lecture Series Network Analyzer Operation John Paden.
System Calibration Fernando Rodriguez-Morales August 7 th, 2007.
Single Balanced Mixer Design ECE 6361
Hamburg European Linear Collider Workshop ECFA LC2013 Krzysztof Krzysik XFEL AMTF Cavity and Module RF Measurement Procedures.
Antenna and Microwave Laboratory Babol Noshirvani University of Technology Antenna and Microwave Laboratory Babol Noshirvani University.
CLIC workshop 2015 EXTRACTION KICKER STRIPLINE MEASUREMENTS C. Belver-Aguilar (IFIC) On behalf of: A. Faus-Golfe (IFIC), F. Toral (CIEMAT), M.J. Barnes.
Bryan, G8DKK. What’s in a Name? You might expect “antenna analysers” to measure antenna pattern as well as VSWR In general - they don’t! They measure.
Calibration of vector network analyzer R&S ZVL. 1.Analyzer is set to pre-defined state (PRESET) 2.Requested central frequency is set (CENTER). 3.Requested.
Introduction to Networks v5.1 Chapter 4: Network Access.
Prof. David R. Jackson Dept. of ECE Notes 15 ECE Microwave Engineering Fall 2015 S-Parameter Measurements 1.
LER workshop 2014 Update on the Extraction Kicker for CLIC DRs: Calibration Tests C. Belver-Aguilar (IFIC) On behalf of: A. Faus-Golfe (IFIC), F. Toral.
Experimental Evaluation of Co-existent LTE-U and Wi-Fi on ORBIT Problem DefinitionExperimental Procedure Results Observation WINLAB Conclusion Samuel
TECHNOLOGICAL EDUCATIONAL INSTITUTE OF CENTRAL MACEDONIA DEPARMENT OF INFORMATICS & COMMUNICATIONS Master of Science in Communication.
Embedded RF Applications/Systems
INDUSTRIAL SEMINAR ON RDSO : TELECOMMUNICATION DEPARTMENT MADE BY: MAMTA CHAUDHARY
The ARFTG/NIST Measurement Comparison Program Kate A. Remley and Robert M. Judish NIST John W. Cable and Yeou-Song (Brian) Lee ARFTG Standards Committee.
4 August An Interlaboratory Comparison of 3.5 mm Coaxial 2-Port Vector Network Analyzer Measurements 4 August 2008 Li Pi Su, Dexter Shelton, George.
Single Ended Measuring Modes of ELQ 30A+
ELEC 401 MICROWAVE ELECTRONICS Microwave Networks - Parameters
BRAZIL ANDERSON RICARDO JUSTO DE ARAÚJO (speaker) RODRIGO CLEBER DA SILVA SÉRGIO KUROKAWA JUNE 2015 Improving the Performance of the Lumped Parameters.
Data transmission characterization with underwater copper link
SUBMITTED BY DINEEJ A 28 S3 EC
Digitizers in CCR for transverse wide-band pick-ups
Internet of Things workshop
XFEL cavities and cryomodules measurements at AMTF
pocketVNA What is a Vector Network Analyzer?
Accelerator Instrumentation and Technology for High Energy Physics
Group Members: ADIL KHAN MEHMAL JAVED
General Network Analyzer
Group Members: ADIL KHAN MEHMAL JAVED
Microwave Engineering
Can we make a wire-measurement, without using matching boxes ?
Beam Position Measurements in TTF Cavities
Ten Steps for Performing TDR (Low Pass Step)
RF Hybrids Jeffrey E Brown Georgia Transmission Corporation
Microwave absorbing material test for ferrite of CAEP
e-cloud Measurements by TE Wave Reflectometry on PEP-II
Phase reference RF work
Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs) Submission Title: [Channel characterization proposed for Body Area Network]
Presentation transcript:

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 1 The IEEE1394 Test Board Results Measurements with a Vector Network Analyzer (VNA) type HP 8753D

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 2 Purpose: To evaluate performance of the new IEEE1394b connectors and cables.

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 3 S 11 Measurements Calibrated with the Open, Short, Load kit at the Cal point.

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 4 S 11 Time Domain Reflection Low Pass, Pulse Mode, Real Part

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 5 S 11 Time Domain Reflection Low Pass, Step Mode, Real Part

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 6 Frequency Domain

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 7 S 21 Measurements Calibrated with the thru method and hybrids connected together.

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 8 Frequency Domain Freq. Domain response of the two cards with connecting cable after calibration of the hybrids directly connected

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 9 Time Domain Transmission, Low Pass, Pulse Mode, Real Part

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 10 Time Domain Transmission, Low Pass, Step Mode, Real Part

June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 11 Conclusions Measurements of parameters in the frequency domain and evaluations in the time domain show that for the required application, this structure should fit the purposes, and in particular, attenuation and rise time degradation are within specifications. Acknowledgment: a particular thank to Tom Kroyer for his help on calibrating and setting-up the VNA.