Prepared By : Lama Asmah Amani Mashaqi Presented To: Dr. Reyad Abdel- Kareem Eng. Emad Al-Qasem Eng. Yaser Al-Jaedee Graduation Project An-Najah National.

Slides:



Advertisements
Similar presentations
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Advertisements

Outline CH1.Introduction CH2.Preliminary Design CH3.3D Model.
Graduation Project Thesis: Structural Analysis & Design of “Al-Mansour Mall”
2.2 STRUCTURAL ELEMENT BEAM
An-Najah National University
Chp12- Footings.
Lecture 9 - Flexure June 20, 2003 CVEN 444.
Structural System Overview
Lecture 33 - Design of Two-Way Floor Slab System
By the name of the god Graduation project presentation.
Abstract This project is a structural analysis and design of a residential building located in JENIEN City, The building is consisted of 7 floors. The.
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Chp.12 Cont. – Examples to design Footings
An-Najah National University Faculty of Engineering Civil Engineering Department Terra Santa School Structural Design and Analysis Prepared By: Bara Shawahna.
Reinforced Concrete Design II
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
Composite Beams and Columns
SHEAR IN BEAMS. SHEAR IN BEAMS Introduction Loads applied to beams produce bending moments, shearing forces, as shown, and in some cases torques. Beams.
Plain & Reinforced Concrete-1 CE-313
Al-Najah National University Engineering Faculty Civil Engineering Department Graduation Project: Analysis & Design of Warehouses in Jaba’-Jenin.
Reinforced Concrete Design
Prepared by: Ayman Naalweh Mustafa Mayyaleh Nidal Turkoman An-Najah National University Faculty of Engineering Civil Engineering Department Graduation.
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Structural Analysis and Design of
Supervisor: Dr. Mahmoud Dweikat.. Outline: 1. Introduction. 2. Static design 3. dynamic design 4. Conclusion.
Graduation Project Thesis  
Chapters Project title : Hirbawi Center A building lies in the east side of Tulkarm, this building consists of five stories of ( m 2 ) A building lies.
Prepared By: Mohammed wafiq omer Mahmoud hammad Abd Algani Sami Malath omair An-Najah National University Faculty of Engineering Civil Engineering Department.
Tulkarem Multipurpose Sport Hall Prepared by: Moatasem Ghanim Abdul-Rahman Alsaabneh Malek Salatneh Supervisor: Dr. Shaker Albitar.
AN-Najah National University Faculty of Engineering Civil Engineering Department Structural Design of a Hotel Building Prepared by: Mohammed Qawariq Faris.
Structural Design of Movenpick Hotel
◦ Ar-Rafedain building is 8 stories reinforced concrete building,located in Nablus city and used as commercial and residential building. ◦ The basement.
Graduation project: Jaba’a Institution Supervised by: Dr. Riyad Abdel-Karim Awad Dr.Sameer El Helw Dr.Sameer El Helw By :Fadi Hamaydi.
Supervisor : Dr. Monther Diab An-Najah National University Faculty of Engineering Civil Engineering Department GRADUATION PROJECT II 3D Analysis and Design.
An-Najah National University Faculty of Engineering Civil Engineering Department.
An-Najah National University Faculty of Engineering Civil Engineering Department Graduation Project Prepared by : 1- Areej Melhem 2- Jawad Ateyani 3-Rasha.
AN-NAJAH NATIONAL UNIVERSITY ENGINEERING COLLEGE Civil Engineering Department Graduation project " AFORI Residential Building Structural Design And Analysis"
Fordham Place Bronx, NY Aric Heffelfinger Structural Option Spring 2006.
Structural Curriculum for Construction Management and Architecture Students 1 Prepared by: Ajay Shanker, Ph.D., P.E. Associate Professor Rinker School.
BEAMS: Beams are structural members that can carry transverse loads which produce bending moments & shear force. Girders: Main load carrying members into.
Design of an integrated 5-Star Hotel
An-Najah Sport Center An-Najah National University
An-Najah National University Faculty of Engineering
AQQABA SECONDRY SCHOOL Structural Design.
Design of Beams for Flexure
جامعة النجاح الوطنية كلية الهندسة قسم هندسة البناء
Structural Design of Technology College in Hebron University
Outline: Introduction: a ) General description of project b) Materials
Integrated design Of Fuel Station
Supervied by : Eng. Ibrahim Mohammad Prepared by : Atheer Daraghmeh
Slender Columns and Two-way Slabs
Analysis and Design of Al-Affori hotel
Welcome to My Presentation
Analysis And Design Of Rawabi Girls’ School Graduation Project
An-Najah National University Faculty of Engineering
Analysis and Design of Multiple story building
  An-Najah National University Faculty of Engineering
Analysis and Redesign of Al – Tatbeqea Faculty
Outline CH1.Introduction CH2.Preliminary Design CH3.3D Model.
An-Najah National University
Supervisor: Dr. Mahmoud Dweikat.
AN-NAJAH NATIONAL UNIVRESITY
Analysis And Design Of AS-Shorooq Residential Building
An Najah National University Submitted to : Dr.Munther Diab .
An-Najah National University
Faculty of Engineering Civil Engineering Department
An-Najah National University
Al-Quds Open University -Nablus
بسم الله الرحمن الرحيم RaRami Abu Baker An- Najah National University
OUTLINES - location & Description. Material properties.
Presentation transcript:

Prepared By : Lama Asmah Amani Mashaqi Presented To: Dr. Reyad Abdel- Kareem Eng. Emad Al-Qasem Eng. Yaser Al-Jaedee Graduation Project An-Najah National University

An-Najah National University Faculty of Engineering

Introduction 1 Slab Beam design 2 Truss Design 3 Column Design 4 Footings and Stair’s Design 5 Three Dimensional Structural Analysis and Design : 6 This project consists of six basic chapters:-

1. General Description : *Geography: The building will be constructed in Hebron with a total area of (2758.6m 2 ). *Geology: the project is expected to be constructed on hard limestone soil with bearing capacity = 2.5 kg/cm². *Structural description: The building has approximately a uniform grid with spans which are constructed as one-way solid slab system. *Architecture description: The project is consisting of single symmetry area around the playground

Architecture plan

2. Materials: *Reinforced concrete: concrete compressive strength f c =28MPa Modulus of elasticity E c = 2.49*10 4 MPa *Steel: Yield stress in steel bars and stirrups=420MPa Minimum yield stress in steel members=344.7 MPa Minimum tensile stress in steel members=448.2 MPa

3. Design Code: The structures are designed using practice, codes and specifications that control the design process and variables. The following codes and standards are used in this study: *ACI : *ACI *IBC- AISC LRDF-2006

4. Loadings: 1. Non-Sway loads **Dead loads: **Live loads : 2. Sway Loads: **Wind loads: truss0.5 KN Concrete slab0.5 KN truss0.5 KN Concrete slab3 KN truss0.5 KN 5. Load combinations: Wu =envelop of all the load cases below: Wu= 1.4 D.L Wu= 1.2 D.L L.L Wu=1.2 D.L +1.6 W.L L.L Wu=0.9 D.L +1.6 W.L

6. Outline of Analysis and Design: Analysis and design is performed for 3 representative frames Interior, Exterior and Inclined The structural analysis needed to: 1. determine the external reactions at the supports 2.determaine the internal forces like moments, shear, and normal forces Theses internal member forces are used to design the cross section of elements.

 Slab design: One way solid slab (pre-casted). Slab thickness Flexure design (+M) Flexure design (- M) Shear design Interior slab30 cm4Ø14 1Ø10/100 mm Exterior slab30 cm4Ø14 1Ø10/100 mm Inclined Slab (the longest span 40 cm12Ø145Ø141Ø10/150 mm

 Beam design: Flexure design (+M) Flexure design (-M) Shear design Interior Beam14Ø25 3Ø251Ø10/150mm Exterior Beam15Ø253Ø251Ø10/250mm Inclined Beam13Ø253Ø251Ø10/200mm Tie Beam2Ø253Ø251Ø10/350mm

Column, Footing Group Footing number (C1), (F1) D2,E2,F2,G2,H2 B4,B5,B6,B7,B8,B9,B10,B11,B12,B13,B14,B15,B16, B17,B18,B19,B20 D22,E22,F22,G22,H22 (C2),(F2) D1,E1,F1,G1,H1, A4,A5,A6,A7,A8,A9,A10,A11,A12,A13,A14,A15,A16, A17, A18 A19, A20 D23,E23,F23,G23,H23 (C3),(F3)I2,122 (C4),(F4)I1,I23 (C5),(F5)C2,B3,B21,C22 (C6),(F6)A2,B1,A22,B23 Table :Classification of the Columns and the Footings.  Columns and Footings Design:

 Column Design : In this project square columns are used. And these columns can carry axial load and moment. Short and long columns (un-braced). Dimension=70*70 cm columnFlexure designShear design Interior 2.25m (C1)10 Ø251Ø10/250 Interior 10m (C2)20Ø361Ø10/250 Exterior 2.25m (C3)10 Ø251Ø10/250 Exterior 10m (C4)20Ø301Ø10/250 Inclined 2.25m (C5)10 Ø251Ø10/250 Inclined 10m (C6)20Ø301Ø10/250

 Footings Design: Footings which used in this project can be classified into the following types :- Footing Name Areas(m)As(in each direction) Interior 2.25m (F1) 1.7*1.7*0.34Ø14 Interior 10m (F2) 2.2*2.2* 0.36Ø14 Exterior 2.25m (F3) 1.5,1.5,0.34Ø14 Exterior 10m (F4) 2,2,0.35Ø14 Inclined 2.25m (F5) 2.1,2.8,0.34Ø14 Inclined 10m (F6) 3,3.7,0.526Ø14 *Single footing : Squire footings---interior and exterior frame Rectangular footings ---inclined frame *Wall footing.

 Retaining wall: Dim (m)As main (mm 2 )As (mm 2 ) Wall3*0.31Ø16/250mm1Ø16/300mm Toe1*0.351Ø16/250mm1Ø12/300mm Heel0.5*0.351Ø16/250mm1Ø12/300mm *Wall footing Ø=30 γ =18 KN/m 2 Fc=28 MPa q all=250KN/m 2

Angle of inclination of stairs: è = tan -1 =  accepted (preferred range degree) h min = 0.25 m (table 9.5.a one end continues slab) SDL=3KN/m 2 LL=5 KN/m 2 Weight of stairs =1.81KN/m 2  Stair Design:

Stair’s Reinforcement With its footing

Control points in Truss Design: 1.Angle: its preferred to be <30 to drain water. *an angle of (Ø=26.6) was suitable. 2. Deflection :less than both of * (L.L ONLY) Accepted Δ L=L*1000/360 * (D.L+ L.L) Accepted Δ D + l=L*1000/240 CHAMBURING

3. Sections: Double symmetry sections. min weight. itemTubepipe Dead weight (KN) Table : Weight comparison of the truss using different types of double symmetry sections (tube and pipe)

 Design of members: * Compression members: If λ < 1.5 Inelastic region: F cr = ( Fy/Fe ) F y If λ > 1.5 Elastic region: F cr = *Fe Ø Pn = Ø*F cr *Ag * Tension members: Yeild: Ø t Pn= Fracture: Ø t Pn= * Zero force members: r min of section ≥L /300

 Weld connection: ØRn=0.75* Fw*0.707*a*L w The required length of weld = Table 3.4: Multipliers to determine the effective length of the weld (β) IF Lw/a<100β1 IF 100<Lw/a<300β= * Lw/a IF Lw/a>300β0.6

7. Three Dimensional Structural Analysis and Design Three dimensional analyses for the stadium have two objectives: 1.making the three dimensional model gives meaning to what is done previously in this project since the main concept of design and analysis of the frames is the tributary area in load distribution. 2. It is vital to trust the two dimensional work, and to have full, good and clear view about the design differences between them.

8. Checks for Three Dimensional Model: 1. Compatibility :

2.Equilibrium:

3. Stress strain relationship: