Applications of CCD Array Spectrometers in Undergraduate Education at EIU Jonathan Blitz and Daniel Sheeran Department of Chemistry.

Slides:



Advertisements
Similar presentations
Atomic Absorption Spectrometer
Advertisements

Spectrophotometric Determination of Iron Using 1,10-Phenanthroline
Raman Spectroscopy A) Introduction IR Raman
An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
Atomic spectroscopy  It’s a class of spectroscopic method in which the species examined in the spectrometer are in the form of atoms.
Flame Test Lab.
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
MEETING 4 ANALYSIS QUALITATIVE CATION. Scale of Qualitative Analysis a. Macro analysis: 0,5-1 gram sample per 20 mL solution b. Semimicro analysis : 0,05.
Atomic Emission Spectroscopy
Soot Particle Aerosol Mass Spectrometer: Development, Validation, and Initial Application T. B. Onasch,A. Trimborn,E. C. Fortner,J. T. Jayne,G. L. Kok,L.
E nergy D ispersive X -ray Fluorescence Spectrometer E nergy D ispersive X -ray Fluorescence Spectrometer EDX-720 Training.
CALCIUM IMAGING Beata M. Wolska, Ph.D.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Spectroscopy Chapter 7.
Lecture 19 Spectrophotometry- III. Light Source Sample Monochromator (filter, wavelength selector) Detector Spectrometer Data Processing.
Lecture 5 An Introduction to Spectroscopy Electromagnetic radiation, electromagnetic wave Emission, absorption, fluorescence.
Introduction to Spectrophotometry
Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Introduction to Instrumental Analysis - Spectrophotometry
Determination of Concentration Using Spectrophotometry
Origin of an Atomic Absorption Peak E2E2 E1E1  E = h Frequency Intensity Energy Transition Absorption Spectrum 1.
Atomic Emission Spectrometry
Flame Photometry Flame atomic emission spectrometry
Atomic Absorption Spectroscopy
Atomic Absorption Spectrometry
Flame Photometry The principles.
Spectroscop1c Analysis Part 6 – Spectroscopic Analysis using Fluorescence and Atomic Absorption Spectrophotometry Chulalongkorn University, Bangkok, Thailand.
Lab 12 Atomic spectra and atomic structure
SPECTROPHOTOMETRY. Determines concentration of a substance in solution by Measures light absorbed by solution at a specific wavelength by using spectrophotometer.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Fluorometric Analysis
Undergraduate Research: Developing “green” experiments for chemistry laboratory course Blain Mamiya, Ph.D., Professor of Chemistry, Independence Community.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 19 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Dr Gihan Gawish King Saud University Riyadh Saudi Arabia 1.
Introduction to Spectrophotometry
EDTA Titration Lab Prep
CHEM 213 Instrumental Analysis Lab Lecture – Fluorescence and Calculations.
SPECTROPHOTOMETRY. Principle : there is interaction between the light and sample particle, spectrophotometer is employed to measure the amount of light.
Spectrophotometry Do you want a footer?.
Area Study 1 Unit  Spectroscopy – energy is used. Energy can be absorbed or emitted. When atoms or molecules absorb energy, can move to higher.
CLS 332 CLINICAL INSTRUMENTAL ANALYSIS. A VISIBLE ABSORPTION SPECTROMETER.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Determination of Concentration Using Spectrophotometry
SPECTROPHOTOMETRY PRACTICAL 213 PHC INSTUMENTAL ANALYSIS.
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
Periodic Table Properties and reactions of group 2 –Ionisation energy –Flame colours (includes group 1) –Reactions with oxygen, water and chlorine –Solubility.
SCANNING LIDAR FLUOROSENSOR FOR REMOTE DIAGNOSTIC OF SURFACES Luisa Caneve F. Colao, R. Fantoni, L. Fiorani, A. Palucci ENEA - UTAPRAD Technical Unit Development.
Measuring Concentration
Testing Positive Ions.
Atomic Absorption Spectrometer
Introduction to Spectrophotometry
Atomic Emission Spectra and Flame Test Lab
Lab1 A VISIBLE ABSORPTION SPECTROMETER
Flame Emission Spectrometry
Introduction to Spectrophotometry
Estimation of analyte concentration on the basis of light absorption
Spectroscopy Chapter 7.
Introduction to Spectrophotometry
Ultraviolet/Visible (UV-Vis) Spectroscopy of Potassium Permanganate
آزمایشگاه فارماکولوژی و سم شناسی
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Spectrophotometry For high school Chemistry, AP Chemistry,
Flame Test Lab.
Spectrophotometer.
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
Flame Test Virtual Lab Make-up Lab.
Clinical instrumental analysis
Presentation transcript:

Applications of CCD Array Spectrometers in Undergraduate Education at EIU Jonathan Blitz and Daniel Sheeran Department of Chemistry

The traditional educational spectrophotometer Single beam Single channel

Multichannel Spectrometer

Spectrophotometry – the mundane Output from Spec-20: Absorbance = Entire spectrum shows λ max and choice of analysis wavelength 2 spectrometers for lab of 24 students is sufficient

The multichannel spectrometer is easily configured for emission spectrometry using a fiber optic probe for light input. This has been used as a portable fluorescence emission spectrometer.

Fluorescence A typical luminescence spectrometerOur luminescence spectrometer Handheld UV Source Multichannel Spectrometer Emission MonochromatorMulitchannel Detector

Fluorescence Emission Spectrum

Absorbance and Fluorescence Emission Spectra of Quinine in Water

Fluorescence Emission Spectra

The multichannel spectrometer has also been used as a detector for qualitative analysis in a traditional flame test …

Fiber Optic Collection of Na Flame Emission Spectrum

Qualitative Analysis “Group IV” Cations: Na +, K +, Ca 2+, Mg 2+, NH 4 + Visual Flame Test: Na: persistent yellow K : transient red or lavender Ca: unreliable, transient red Na masks K when both are present (Co blue filter) False + and false – for Ca common with visual flame test

Qualitative Analysis Spectrometer Flame Test: Na and K easily detected and distinguished Ca not detected, chemical test only

Qualitative Analysis Spectrometer Flame Test Student Results: Na > 95% correct on 1 st try K > 95% correct on 1 st try Ca > 98% correct on 1 st try Fewer false +, fewer false – No blue filter for visual observation of K

Quantitative Analysis Emission intensity is transient and variable Use another alkali as an internal standard Sample introduction with a nichrome wire does not provide adequate quantitative results Aspirate a sample using a continuous sprayer into the air intake of a Bunsen burner for improved sample introduction

Compressed Air Spectrometer Fiber optic

K unknown = ppmMeasured = ppm Student results not that good, but calibrations are OK Detection limits using spray: ppm for all alkalis Detection limits much lower using nichrome wire

Conclusions A multichannel spectrometer is useful for teaching spectrophotometry Using a fiber optic probe the spectrometer was configured for the following tasks: As a fluorescence emission spectrometer For qualitative analysis of alkalis For quantitative analysis of alkalis using an internal standard calibration